• Title/Summary/Keyword: Pressure transducer

Search Result 329, Processing Time 0.029 seconds

Mass Flow Rate Measurement of Pulsating Flow in a Twin-Scroll Turbocharger (트윈스크롤 터보과급기에서 맥동유동의 질량유량 측정)

  • Chung, Jin-Eun;Jeon, Se-Hun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.20 no.12
    • /
    • pp.723-729
    • /
    • 2019
  • Turbochargers are an effective device to reduce the fuel consumption. In this study, the mass flow rate of pulsating flow in the twin-scroll turbocharger for the gasoline engine of passenger vehicles was measured. Pulsating flow was achieved using a pulse generator and the mass flow rate of the unsteady pulsating flow was analyzed by comparing it with those of the steady flow. The pulse generator consisted of a rotating upper plate and a fixed lower plate. To measure the mass flow rate of unsteady flow, the orifice flow meter equipped with the difference pressure transducer was used. To analyze the low speed performance of the turbocharger, the measurement was carried out in the speed of turbocharger from 60,000rpm to 100,000rpm. The mass flow parameters of the unsteady pulsating flow showed a large difference compared to those of the steady flow. Those of the unsteady flow showed the hysteresis loop surrounding the mass flow parameters of the steady flow and the maximum variation of the mass flow parameters were 5.0 times those of the steady flow. This phenomenon is the result of the filling and emptying the turbine volute space due to pulsating flow.

Flow characteristics analysis and test in the Pelton turbine for pico hydro power using surplus water (잉여 유출수를 이용한 소수력발전용 수차의 유동특성 해석 및 시험)

  • Jeong, Seon Yong;Lee, Kye Bock
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.17 no.4
    • /
    • pp.325-331
    • /
    • 2016
  • Computational fluid numerical analysis using the commercial code CFX was performed to develop a Pelton turbine for a pico hydro power generator using the circulating water of a cooling tower in a large building. The performance of the Pelton turbine was examined for different design factors, such as the bucket shape, in which the Pelton wheel was connected in an appropriate manner to the pipe section, and the number of buckets in order to find the optimal design of Pelton turbine for a pico hydro power using surplus water. A benchmark test was carried out on the manufactured small scale Pelton turbine to validate the design method of the Pelton turbine by numerical analysis. The results obtained by comparing the flow characteristics and power output measured using the ultrasonic flowmeter, the pressure transducer and the oscilloscope with the numerical results confirmed the validity of the analytical design method. The possibility of developing Pelton turbines for kW class pico hydro power generators using surplus water with an average circulation velocity of 1.2 m/s for the chosen bucket shape and number of buckets in a 30 m high building was confirmed.

Effect of Ethanol Extract of Diospyros Kaki Thunberg on the Motility of Isolated Rabbit Duodenum (감나무의 Ethanol 추출액(抽出液)이 척출가토(剔出家兎) 장관운동(腸管運動)에 미치는 영향(影響))

  • Lee, Young-Bae;Shin, Hong-Kee;Kim, Kee-Soon
    • The Korean Journal of Physiology
    • /
    • v.11 no.1
    • /
    • pp.27-32
    • /
    • 1977
  • Diospyros Kaki Thunberg is the species of persimmon tree that grows in Korea. Although its fresh or dried fruits are often served as a desert, it has little been known if persimmon tree has any specific pharmacological action. The leaves and branches of persimmon tree has long been used as folk remedies for palsy and frostbite in the southern part of Korea and it is also in use for the treatment of hiccup and nocturnal enuresis in chinese herbal medicine. Recently it was reported that an intravenous administration of Diospyros Kaki Thunberg ethanol extract (KTEE) into the animals lowered arterial blood pressure. Lee concluded from his study on the mechanism of depressor action of KTEE that at least a part of depressor response he observed was caused by acetylcholine-like action of KTEE. On the other hand little study has been made on the effect of KTEE on the motility of isolated animal intestines. Therefore the present study was undertaken to investigate effect of KTEE and the mechanism of its action on the motility of isolated rabbit duodenum. Ethanol extract of Diospyros Kaki Thunberg was prepared by boiling 1 kg of dried branches of persimmon tree in 1 liter of ethanol and the motility of isolated rabbit duodenum was recorded on physiograph by means of force transducer connected with Magnus apparatus. Doses of KTEE used were $5{\times}10^{-4}gm/ml,\;1{\times}10^{-3}gm/ml,\;and\;2{\times}10^{-3}gm/ml$. And the isolated duodenum was separately pretreated with acetylcholine $(5{\times}10^{-7}gm/ml)$, pilocarpine $(2.5{\times}10^{-6}gm/ml)$, histamine $(5{\times}10^{-6}gm/ml)$ and barium chloride $(2.5{\times}10^{-5}gm/ml)$ in order to find out interactions of these drugs with KTEE. The results obtained are as follows: 1. At doses of $5{\times}10^{-4}gm/ml,\;1{\times}10^{-3}gm/ml$ KTEE reduced contractions of isolated duodenum, while tonus as well as contaction of duodenum were depressed with $2{\times}10^{-3}gm/ml$ of KTEE. 2. Since the inhibitory effect of KTEE on the intestinal motility was not blocked by pretreatment with acetylcholine, pilocarpine, and barium chloride, it was strongly suggested that the inhibitory action of KTEE on intestinal motility is mainly Caused by its antihistamine effect. 3. It is also concluded that the principal substance of KTEE responsible for inhibition of intestinal motility may also have a vasodilating activity and would not be an acetylcholine-like substance in case it is same substance as that cause depressor responses.

  • PDF

Vasorelaxing Mechanism of Crude Saponin of Korea Red Ginseng in the Resistance-sized Mesenteric Artery of Rat

  • Kim, Shin-Hye;Park, Hyung-Seo;Lee, Mee-Young;Oh, Young-Sun;Kim, Se-Hoon
    • Journal of Ginseng Research
    • /
    • v.26 no.1
    • /
    • pp.1-5
    • /
    • 2002
  • It has been well known that Korea red ginseng has an antihypertensive effect. The antihypertensive effect may be due to its ability to change the peripheral resistance. Change of vascular tone in the resistance-sized artery contribute to the peripheral resistance, thereby regulate the blood pressure. Therefore, we investigated to clarify the vasorelaxing mechanism induced by crude saponin of Korea red ginseng in the resistance-sized mesenteric artery of rats. The resistance-sized mesenteric artery was isolated and cut into a ring. The ring segment was immersed in HEPES-buffered solution and its isometric tension was measured using myograph force-displacement transducer. Crude saponin of ginseng relaxed the mesenmetric arterial rings precontracted with norepinephrine (3$\mu$M) in dose-dependent manner (0.01 mg/㎖ -1 mg/㎖. The relaxation by crude saponin was smaller in endothelium-intact preparation than that in endothelium-denuded preparation. The contraction induced by A23187 or phorbol 12,13-dibutyrate was not affected by crude saponin of ginseng. The vasorelaxing effect of crude saponin of ginseng was significantly attenuated by the increase of the extracellular K$\^$+/ concentration. Crude saponin-induced vasorelaxation was not affected by tetraethylammonium (1 mM), glybenclamide (10$\mu$M), and 4-aminopyridine (0.1 mM) in these preparations. Ba$\^$2+/(10$\mu$M ∼100$\mu$M) markedly reduced the crude saponin-induced vasorelakation dose-dependently. From the above results, we suggest that crude saponin of ginseng may stimulate K$\^$+/ efflux and hyperpolarize the membrane, thereby cause the vasorelaxation in the resistance-sized mesenteric artery of rats.

A Study on Vibration & Noise Reduction of Fast Back Feeding Device for Manufacturing Process (제조공정용 Fast Back 이송장치 진동·소음 저감에 관한 연구)

  • Han, Doo-Hee;Lee, Seung-Hun;Son, Yung-Deug
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.20 no.8
    • /
    • pp.642-648
    • /
    • 2019
  • This paper presents a fast back-type transfer device for snack food processing that uses the inertia of transferred material. A conventional conveying system is a drive system that uses a belt conveyor and mechanical crank, which generate noise and vibration and cause environmental pollution. Vibration and noise are reduced in the proposed fast back feeding device by using a counterweight. The crank drive unit was replaced with a linear servomotor, and an equilibrium device was designed to balance the force due to acceleration. This makes it is possible to adjust the forward and backward speed and acceleration through PLC control. A vibration damper device offsets the vibration force of the periodic shock form. The main cause of the vibration was identified through vibration analysis, and reduction measures were established. We verified the effectiveness of the vibration by making a prototype and performing about 10 vibration tests. Because no mechanical transducer is needed, energy loss, noise, and vibration do not occur, and the operating speed is not limited.

M-mode Ultrasound Assessment of Diaphragmatic Excursions in Chronic Obstructive Pulmonary Disease : Relation to Pulmonary Function Test and Mouth Pressure (만성폐쇄성 폐질환 환자에서 M-mode 초음파로 측정한 횡격막 운동)

  • Lim, Sung-Chul;Jang, Il-Gweon;Park, Hyeong-Kwan;Hwang, Jun-Hwa;Kang, Yu-Ho;Kim, Young-Chul;Park, Kyung-Ok
    • Tuberculosis and Respiratory Diseases
    • /
    • v.45 no.4
    • /
    • pp.736-745
    • /
    • 1998
  • Background: Respiratory muscle interaction is further profoundly affected by a number of pathologic conditions. Hyperinflation may be particularly severe in chronic obstructive pulmonary disease(COPD) patients, in whom the functional residual capacity(FRC) often exceeds predicted total lung capacity(TLC). Hyperinflation reduces the diaphragmatic effectiveness as a pressure generator and reduces diaphragmatic contribution to chest wall motion. Ultrasonography has recently been shown to be a sensitive and reproducible method of assessing diaphragmatic excursion. This study was performed to evaluate how differences of diaphragmatic excursion measured by ultrasonography associate with normal subjects and COPD patients. Methods: We measured diaphragmatic excursions with ultrasonography on 28 healthy subjects(l6 medical students, 12 age-matched control) and 17 COPD patients. Ultrasonographic measurements were performed during tidal breathing and maximal respiratory efforts approximating vital capacity breathing using Aloka KEC-620 with 3.5 MHz transducer. Measurements were taken in the supine posture. The ultrasonographic probe was positioned transversely in the midclavicular line below the right subcostal margin. After detecting the right hemidiaphragm in the B-mode the ultrasound beam was then positioned so that it was approximately parallel to the movement of middle or posterior third of right diaphragm. Recordings in the M-mode at this position were made throughout the test. Measurements of diaphragmatic excursion on M-mode tracing were calculated by the average gap in 3 times-respiration cycle. Pulmonary function test(SensorMedics 2800), maximal inspiratory(PImax) and expiratory mouth pressure(PEmax, Vitalopower KH-101, Chest) were measured in the seated posture. Results: During the tidal breathing, diaphragmatic excursions were recorded $1.5{\pm}0.5cm$, $1.7{\pm}0.5cm$ and $1.5{\pm}0.6cm$ in medical students, age-matched control group and COPD patients, respectively. Diaphragm excursions during maximal respiratory efforts were significantly decreased in COPD patients ($3.7{\pm}1.3cm$) when compared with medical students, age-matched control group($6.7{\pm}1.3cm$, $5.8{\pm}1.2cm$, p< 0.05}. During maximal respiratory efforts in control subjects, diaphragm excursions were correlated with $FEV_1$, FEVl/FVC, PEF, PIF, and height. In COPD patients, diaphragm excursions during maximal respiratory efforts were correlated with PEmax(maximal expiratory pressure), age, and %FVC. In multiple regression analysis, the combination of PEmax and age was an independent marker of diaphragm excursions during maximal respiratory efforts with COPD patients. Conclusion: COPD subjects had smaller diaphragmatic excursions during maximal respiratory efforts than control subjects. During maximal respiratory efforts in COPD patients, diaphragm excursions were well correlated with PEmax. These results suggest that diaphragm excursions during maximal respiratory efforts with COPD patients may be valuable at predicting the pulmonary function.

  • PDF

Carotid artery intima media thickness in obese children : relation with cardiovascular risk factors (비만 소아에서 경동맥 내중막 두께와 심혈관질환 위험인자와의 상관관계)

  • Lee, Jin;Kwon, Hyo Jin;Park, Moon Ho;Jang, Ki Young;Lee, Kee-Hyoung;Lee, Kwang Chul;Son, Chang Sung;Lee, Joo Won
    • Clinical and Experimental Pediatrics
    • /
    • v.50 no.11
    • /
    • pp.1091-1096
    • /
    • 2007
  • Purpose : The of common carotid artery intima media thickness (IMT) is an acknowledged noninvasive marker for early atherosclerotic changes. We investigate whether common carotid IMT is different between obese and normal-weight children and also evaluate the relationships IMT with cardiovascular risk factors. Methods : We collected the clinical data (age, sex, pubertal stage, body mass index) and measured blood pressure, glucose, insulin, lipid profiles and adiponectin in 49 obese children (mean age, 12 years) and 24 nonobese children as controls. The control group was composed of 24 nonobese children of the same age, sex and pubertal stage. We measured the carotid IMT of all subjects by B-mode ultrasound with a 7.5-MHz linear transducer and analyzed. Results : Obese children demonstrated a significantly thicker intima media (mean, 0.34 mm, peak, 0.42 mm) compared to the control group (mean, 0.31 mm, peak, 0.38 mm, P<0.01). IMT was significantly correlated to the BMI (r=0.431, P<0.01), age (r=0.317, P<0.01), total cholesterol (r=0.377, P< 0.01), triglyceride (r=0.253, P<0.05) and low-density lipoprotein cholesterol (r=0.289, P<0.05). Serum adiponectin was significantly lower in obese children than in controls (11.2 ng/mL vs. 14.7 ng/mL, P<0.05) and negatively related with IMT (r=-0.267, P<0.05). Conclusion : Obesity is associated with increased carotid artery IMT in children. Our results suggest vascular changes in obesity seem to occur already in childhood and vascular ultrasonography may helpful for screening cardiovascular complications in obese children.

Feasibility Test on Automatic Control of Soil Water Potential Using a Portable Irrigation Controller with an Electrical Resistance-based Watermark Sensor (전기저항식 워터마크센서기반 소형 관수장치의 토양 수분퍼텐셜 자동제어 효용성 평가)

  • Kim, Hak-Jin;Roh, Mi-Young;Lee, Dong-Hoon;Jeon, Sang-Ho;Hur, Seung-Oh;Choi, Jin-Yong;Chung, Sun-Ok;Rhee, Joong-Yong
    • Journal of Bio-Environment Control
    • /
    • v.20 no.2
    • /
    • pp.93-100
    • /
    • 2011
  • Maintenance of adequate soil water potential during the period of crop growth is necessary to support optimum plant growth and yields. A better understanding of soil water movement within and below the rooting zone can facilitate optimal irrigation scheduling aimed at minimizing the adverse effects of water stress on crop growth and development and the leaching of water below the root zone which can have adverse environmental effects. The objective of this study was to evaluate the feasibility of using a portable irrigation controller with an Watermark sensor for the cultivation of drip-irrigated vegetable crops in a greenhouse. The control capability of the irrigation controller for a soil water potential of -20 kPa was evaluated under summer conditions by cultivating 45-day-old tomato plants grown in three differently textured soils (sandy loam, loam, and loamy sands). Water contents through each soil profile were continuously monitored using three Sentek probes, each consisting of three capacitance sensors at 10, 20, and 30 cm depths. Even though a repeatable cycling of soil water potential occurred for the potential treatment, the lower limit of the Watermark (about 0 kPa) obtained in this study presented a limitation of using the Watermark sensor for optimal irrigation of tomato plants where -20 kPa was used as a point for triggering irrigations. This problem might be related to the slow response time and inadequate soil-sensor interface of the Watermark sensor as compared to a porous and ceramic cup-based tensiometer with a sensitive pressure transducer. In addition, the irrigation time of 50 to 60 min at each of the irrigation operation gave a rapid drop of the potential to zero, resulting in over irrigation of tomatoes. There were differences in water content among the three different soil types under the variable rate irrigation, showing a range of water contents of 16 to 24%, 17 to 28%, and 24 to 32% for loamy sand, sandy loam, and loam soils, respectively. The greatest rate increase in water content was observed in the top of 10 cm depth of sandy loam soil within almost 60 min from the start of irrigation.

THE CURRENT STATUS OF BIOMEDICAL ENGINEERING IN THE USA

  • Webster, John G.
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1992 no.05
    • /
    • pp.27-47
    • /
    • 1992
  • Engineers have developed new instruments that aid in diagnosis and therapy Ultrasonic imaging has provided a nondamaging method of imaging internal organs. A complex transducer emits ultrasonic waves at many angles and reconstructs a map of internal anatomy and also velocities of blood in vessels. Fast computed tomography permits reconstruction of the 3-dimensional anatomy and perfusion of the heart at 20-Hz rates. Positron emission tomography uses certain isotopes that produce positrons that react with electrons to simultaneously emit two gamma rays in opposite directions. It locates the region of origin by using a ring of discrete scintillation detectors, each in electronic coincidence with an opposing detector. In magnetic resonance imaging, the patient is placed in a very strong magnetic field. The precessing of the hydrogen atoms is perturbed by an interrogating field to yield two-dimensional images of soft tissue having exceptional clarity. As an alternative to radiology image processing, film archiving, and retrieval, picture archiving and communication systems (PACS) are being implemented. Images from computed radiography, magnetic resonance imaging (MRI), nuclear medicine, and ultrasound are digitized, transmitted, and stored in computers for retrieval at distributed work stations. In electrical impedance tomography, electrodes are placed around the thorax. 50-kHz current is injected between two electrodes and voltages are measured on all other electrodes. A computer processes the data to yield an image of the resistivity of a 2-dimensional slice of the thorax. During fetal monitoring, a corkscrew electrode is screwed into the fetal scalp to measure the fetal electrocardiogram. Correlations with uterine contractions yield information on the status of the fetus during delivery To measure cardiac output by thermodilution, cold saline is injected into the right atrium. A thermistor in the right pulmonary artery yields temperature measurements, from which we can calculate cardiac output. In impedance cardiography, we measure the changes in electrical impedance as the heart ejects blood into the arteries. Motion artifacts are large, so signal averaging is useful during monitoring. An intraarterial blood gas monitoring system permits monitoring in real time. Light is sent down optical fibers inserted into the radial artery, where it is absorbed by dyes, which reemit the light at a different wavelength. The emitted light travels up optical fibers where an external instrument determines O2, CO2, and pH. Therapeutic devices include the electrosurgical unit. A high-frequency electric arc is drawn between the knife and the tissue. The arc cuts and the heat coagulates, thus preventing blood loss. Hyperthermia has demonstrated antitumor effects in patients in whom all conventional modes of therapy have failed. Methods of raising tumor temperature include focused ultrasound, radio-frequency power through needles, or microwaves. When the heart stops pumping, we use the defibrillator to restore normal pumping. A brief, high-current pulse through the heart synchronizes all cardiac fibers to restore normal rhythm. When the cardiac rhythm is too slow, we implant the cardiac pacemaker. An electrode within the heart stimulates the cardiac muscle to contract at the normal rate. When the cardiac valves are narrowed or leak, we implant an artificial valve. Silicone rubber and Teflon are used for biocompatibility. Artificial hearts powered by pneumatic hoses have been implanted in humans. However, the quality of life gradually degrades, and death ensues. When kidney stones develop, lithotripsy is used. A spark creates a pressure wave, which is focused on the stone and fragments it. The pieces pass out normally. When kidneys fail, the blood is cleansed during hemodialysis. Urea passes through a porous membrane to a dialysate bath to lower its concentration in the blood. The blind are able to read by scanning the Optacon with their fingertips. A camera scans letters and converts them to an array of vibrating pins. The deaf are able to hear using a cochlear implant. A microphone detects sound and divides it into frequency bands. 22 electrodes within the cochlea stimulate the acoustic the acoustic nerve to provide sound patterns. For those who have lost muscle function in the limbs, researchers are implanting electrodes to stimulate the muscle. Sensors in the legs and arms feed back signals to a computer that coordinates the stimulators to provide limb motion. For those with high spinal cord injury, a puff and sip switch can control a computer and permit the disabled person operate the computer and communicate with the outside world.

  • PDF