• 제목/요약/키워드: Pressure tap diameter

검색결과 9건 처리시간 0.02초

$Annubar^{(R)}$형 차압유량계 형상 개선에 따른 유량 특성 연구 (A Study on Flow Rate Characteristics of a $Annubar^{(R)}$ Type Differential Pressure Flow Meter with a Shape Improvement)

  • 오대산;이충훈
    • 한국생산제조학회지
    • /
    • 제19권2호
    • /
    • pp.204-210
    • /
    • 2010
  • The inner structure of the triangular separate bar (TSB) was improved to enhance the productivity of the TSB flow meter by simplifying the machining process for making the flow meter. The cross section of upstream and downstream pressure chamber in the TSB was changed from triangle to circle, which make it possible to substitute the wire cutting by drilling in the process of machining the pressure chamber. The flow rate characteristics of the flow meters was calibrated with a laminar flow meter. Six kinds of flow meters whose diameters of pressure tap for measuring pressure of both upsteam and downstream pressure chamber were different one another were made. The effects of the pressure tap diameter on the flow rate characteristics of the TSB flow meter was little. The mass flow rate characteristics of the flow meters with increasing a non-dimensional parameter which includes the gas temperature, exhaust gas pressure and differential pressure at the flow meters and atmospheric pressure shows nearly linear relationship with a correlation coefficient of R=0.998.

삼첨판 성형술 [De Vega 술식]의 원격 성적에 대한 고찰 (Long term resuls of De Vega tricuspid annuloplasty)

  • 김병열
    • Journal of Chest Surgery
    • /
    • 제26권11호
    • /
    • pp.827-832
    • /
    • 1993
  • From Jan 1982 through Dec.1991, thirty-three DeVega`s tricuspid annuloplasties were performed in association with mitral and combined mitral and aortic valve disease. Preoperatively,all of the patients were in NYHA functional class III or IV.There were one early death and 4 patients died during follow up period of 18 to 138 months [ mean follow up : 67.3 months ]. Nine patients required reoperation because of biological mitral valve failure at 4.7 to 11 years after tricuspid annuloplasty[TAP]. Among these patients,2 cases needed for reoperation of TAP due to loosening of suture material. Twenty four [86%] of the survivors were in NYHA functional class I or II after TAP.The actuarial survival rate for the TAP was 74% at 138 months. Rt atrial pressure of 9 reoperation cases were significantly decreased [P<0.05] compared with initial Rt.atrial pressure [ Mean period; 93.6 months].Doppler echocardiographic studies for tricuspid regurgitation were performed in 15 cases after TAP [Mean period: 42.3 months].These results showed significantly reduced [P<0.01] tricuspid annulus diameter and tricuspid regurgitation distance [ P<0.05 ].Our surgical experience that the DeVega`s TAP is a simple,safe,effective procedure and resulted in good hemodynamic improvement with moderate to severe functional tricuspid regurgitation.

  • PDF

자연순환형 태양열 온수기 축열조의 압력식 설계 개조 (Design Modification of a Thermal Storage Tank of Natural-Circulation Solar Water Heater for a Pressurized System)

  • 부준홍;정의국
    • 한국태양에너지학회 논문집
    • /
    • 제27권3호
    • /
    • pp.45-54
    • /
    • 2007
  • For a conventional natural-circulation type solar water heater, the pressure head is limited by the height between the storage tank and hot water tap. Therefore, it is difficult to provide sufficient hot water flow rate for general usage. This study deals with a design modification of the storage tank to utilize the tap-water pressure to increase hot-water supply Based on fluid dynamic and heat transfer theories, a series of modeling and simulation is conducted to achieve practical design requirements. An experimental setup is built and tested and the results are compared with theoretical simulation model. The storage tank capacity is 240 l and the outer diameter of piping was 15 mm. Number of tube turns tested are 5, 10, and 15. Starting with initial storage tank temperature of $80^{\circ}C$, the temperature variation of the supply hot water is investigated against time, while maintaining minimum flow rate of 10 1/min. Typical results show that the hot water supply of minimum $30^{\circ}C$ can be maintained for 34 min with tap-water supply pressure of 2.5 atm, The relative errors between modeling and experiments coincide well within 10% in most cases.

분리막을 이용한 무전해 PCB 도금 폐수의 재활용 (Wastewater Recycling from Electroless Printed Circuit Board Plating Process Using Membranes)

  • 이동훈;김래현;정건용
    • 멤브레인
    • /
    • 제13권1호
    • /
    • pp.9-19
    • /
    • 2003
  • 무전해 PCB 도금 공정 수세액을 분리막으로 처리하여 투과수는 공업용수로 재사용하고 유가금속인 금(Au)을 회수하는 방법에 관하여 연구하였다. 역삼투 분리막 테스트 셀을 이용하여 수세액 처리에 적합한 분리막을 선정하였으며 scale-up을 위한 나권형 모듈 투과 실험을 실시하였다. 먼저, (주)새한에서 생산되는 RO-TL(tap water, low pressure), RO-BL(brackish water, low pressure), RO-normal(for water purifier)막으로 투과실험하였으며 그 중 RO-TL막이 soft etching, 촉매 및 Ni 수세액 처리에 우수한 것으로 판명되었다. 따라서 RO-TL막으로 제작한 나권형 가정용 정수기 모듈로 7bar, $25^{\circ}C$에서 scale-up 실험을 수행하였다. Au수세액의 투과 유속은 약 30 LMH로서 가장 높았으나 Au 제거율이 80% 미만이었다. Pd, Ni 및 soft etching 수세액의 투과유속은 각각 약 22, 17, 10 LMH 정도이며 Pd의 제거율은 85% 이상, Ni 및 Cu 제거율은 97% 이상이었다. 또한 Au, Ni 및 Cu 이온이 함유된 수세액 중 유가금속인 Au를 선택적으로 회수하기 위하여 NF막을 사용하였다. Au수세액 중 Ni 및 Cu 이온은 대부분 제거되었으며 투과액 중에 Au이온이 81.9% 존재하였고 계속하여 RO-TL막으로 Au를 농축 회수하였다. 마지막으로 4"직경의 NF 및 RO-TL 나권형 모듈을 연속적으로 사용하여 Au를 효과적으로 회수할 수 있음을 재확인하였다.인하였다.

초미세기포를 이용한 해양쓰레기 표면 내 염분제거에 관한 연구 (A Study of the Salt Rejection from the Surface of Marine Waste using Ultra Fine Bubble)

  • 김보민;김광구;박찬규
    • 한국산학기술학회논문지
    • /
    • 제22권6호
    • /
    • pp.11-18
    • /
    • 2021
  • 나노버블수는 태양광 패널 청소, 도로의 염분 제거, 기계의 정밀 부품 청소 등 다양한 세척 공정에 사용된다. 해양쓰레기 세척 시스템의 전처리에 나노버블을 적용하면 높은 세척 효율과 물 절약이 가능하다. 본 연구에서는 나노버블수의 염분 제거율을 비교하기 위해 NaCl 200,000 mg/L 용액에 목재를 침적시켜 해양쓰레기를 제작하였다. 수돗물과 나노버블수를 이용하여 노즐 종류, 오리피스 직경, 펌프 회전수 및 세척 시간에 따른 목재 표면 염분농도를 비교하였다. 목재 표면 염분농도는 세척시간이 길어질수록 감소하였다. 하지만 물 사용량을 고려한 최적의 세척 시간은 5-10초 사이였다. 노즐의 오리피스 직경이 커질수록 분사압력은 낮아지며, 세척 후 목재 표면 염분농도는 높아졌다. 이는 노즐의 오리피스 직경이 세척 시스템에서 중요한 요인임을 나타낸다. 나노버블수를 이용한 세척 후 목재 표면 염분농도는 수돗물로 세척 후 목재 표면 염분농도에 비해 부채꼴형 노즐은 2.2 %, 원형 노즐은 30.9 % 낮았다. 또한, 나노버블수를 이용한 세척 실험에서 부채꼴형 노즐을 사용하여 세척하였을 때가 원형 노즐을 사용하였을 때보다 목재 표면 염분농도가 약 9.5 mg/L 낮았다.

임플랜트 식립부위 형성시 골조직의 온도변화에 관한 연구 (A STUDY ON THE TEMPERATURE CHANGES OF BONE TISSUES DURING IMPLANT SITE PREPARATION)

  • 김평일;김영수;장경수;김창회
    • 대한치과보철학회지
    • /
    • 제40권1호
    • /
    • pp.1-17
    • /
    • 2002
  • The purpose of this study is to examine the possibility of thermal injury to bone tissues during an implant site preparation under the same condition as a typical clinical practice of $Br{\aa}nemark$ implant system. All the burs for $Br{\aa}nemark$ implant system were studied except the round bur The experiments involved 880 drilling cases : 50 cases for each of the 5 steps of NP, 5 steps of RP, and 7 steps of WP, all including srew tap, and 30 cases of 2mm twist drill. For precision drilling, a precision handpiece restraining system was developed (Eungyong Machinery Co., Korea). The system kept the drill parallel to the drilling path and allowed horizontal adjustment of the drill with as little as $1{\mu}m$ increment. The thermocouple insertion hole. that is 0.9mm in diameter and 8mm in depth, was prepared 0.2mm away from the tapping bur the last drilling step. The temperatures due to countersink, pilot drill, and other drills were measured at the surface of the bone, at the depths of 4mm and 8mm respectively. Countersink drilling temperature was measured by attaching the tip of a thermocouple at the rim of the countersink. To assure temperature measurement at the desired depths, 'bent-thermocouples' with their tips of 4 and 8mm bent at $120^{\circ}$ were used. The profiles of temperature variation were recorded continuously at one second interval using a thermometer with memory function (Fluke Co. U.S.A.) and 0.7mm thermocouples (Omega Co., U.S.A.). To simulate typical clinical conditions, 35mm square samples of bovine scapular bone were utilized. The samples were approximately 20mm thick with the cortical thickness on the drilling side ranging from 1 to 2mm. A sample was placed in a container of saline solution so that its lower half is submerged into the solution and the upper half exposed to the room air, which averaged $24.9^{\circ}C$. The temperature of the saline solution was maintained at $36.5^{\circ}C$ using an electric heater (J. O Tech Co., Korea). This experimental condition was similar to that of a patient s opened mouth. The study revealed that a 2mm twist drill required greatest attention. As a guide drill, a twist drill is required to bore through a 'virgin bone,' rather than merely enlarging an already drilled hole as is the case with other drills. This typically generates greater amount of heat. Furthermore, one tends to apply a greater pressure to overcome drilling difficulty, thus producing even greater amount heat. 150 experiments were conducted for 2mm twist drill. For 140 cases, drill pressure of 750g was sufficient, and 10 cases required additional 500 or 100g of drilling pressure. In case of the former. 3 of the 140 cases produced the temperature greater than $47^{\circ}C$, the threshold temperature of degeneration of bone tissue (1983. Eriksson et al.) which is also the reference temperature in this study. In each of the 10 cases requiring extra pressure, the temperature exceeded the reference temperature. More significantly, a surge of heat was observed in each of these cases This observations led to addtional 20 drilling experiments on dense bones. For 10 of these cases, the pressure of 1,250g was applied. For the other 10, 1.750g were applied. In each of these cases, it was also observed that the temperature rose abruptly far above the thresh old temperature of $47^{\circ}C$, sometimes even to 70 or $80^{\circ}C$. It was also observed that the increased drilling pressure influenced the shortening of drilling time more than the rise of drilling temperature. This suggests the desirability of clinically reconsidering application of extra pressures to prevent possible injury to bone tissues. An analysis of these two extra pressure groups of 1,250g and 1,750g revealed that the t-statistics for reduced amount of drilling time due to extra pressure and increased peak temperature due to the same were 10.80 and 2.08 respectively suggesting that drilling time was more influenced than temperature. All the subsequent drillings after the drilling with a 2mm twist drill did not produce excessive heat, i.e. the heat generation is at the same or below the body temperature level. Some of screw tap, pilot, and countersink showed negative correlation coefficients between the generated heat and the drilling time. indicating the more the drilling time, the lower the temperature. The study also revealed that the drilling time was increased as a function of frequency of the use of the drill. Under the drilling pressure of 750g, it was revealed that the drilling time for an old twist drill that has already drilled 40 times was 4.5 times longer than a new drill The measurement was taken for the first 10 drillings of a new drill and 10 drillings of an old drill that has already been used for 40 drillings. 'Test Statistics' of small samples t-test was 3.49, confirming that the used twist drills require longer drilling time than new ones. On the other hand, it was revealed that there was no significant difference in drilling temperature between the new drill and the old twist drill. Finally, the following conclusions were reached from this study : 1 Used drilling bur causes almost no change in drilling temperature but increase in drilling time through 50 drillings under the manufacturer-recommended cooling conditions and the drilling pressure of 750g. 2. The heat that is generated through drilling mattered only in the case of 2mm twist drills, the first drill to be used in bone drilling process for all the other drills there is no significant problem. 3. If the drilling pressure is increased when a 2mm twist drill reaches a dense bone, the temperature rises abruptly even under the manufacturer-recommended cooling conditions. 4. Drilling heat was the highest at the final moment of the drilling process.

삼상유동층 공정에서 수력학적 Similarity 해석 (Analysis of Hydrodynamic Similarity in Three-Phase Fluidized Bed Processes)

  • 임호;임현오;진해룡;임대호;강용
    • Korean Chemical Engineering Research
    • /
    • 제49권6호
    • /
    • pp.790-797
    • /
    • 2011
  • 삼상유동층에서 수력학적 유사성을 규모인자(scaling factor)를 이용하여 해석하였다. 규모인자는 직경이 다른 두 종류의 삼상유동층간의 기체, 액체, 그리고 고체입자의 체류량과 단위면적당 유효부피흐름속도를 기준으로 정의하였다. 두 종류 삼상유동층의 직경은 각각 0.102 m와 0.152 m이었다. 여과된 압축공기, 물 그리고 밀도가 2,500 kg/$m^3$인 유리구슬을 각각 기체, 액체 그리고 유동고체입자로 사용하였다. 각 삼상유동층에서 각 상들의 체류량은 정압강하법에의해 결정하였다. 기체 및 액체의 유속 그리고 고체유동입자의 크기가 각 상들을 기준으로한 규모인자와 유효부피흐름속도를 기준으로한 규모인자에 미치는 영향을 검토하였다. 직경이 다른 두 삼상유동층에서 기체 체류량의 편차는 기체와 액체의 유속이 증가함에 따라 감소하였으나 유동입자의 크기가 증가함에 따라 증가하였다. 직경이 다른 두 종류 삼상유동층에서 액체 체류량 편차는 기체와 액체 그리고 고체유동입자의 크기가 증가함에 따라 감소하였다. 두 종류 삼상유동층에서 고체입자 체류량 편차는 기체유속과 유동입자의 크기가 증가함에 따라 증가하였으나 액체의 유속이 증가함에 따라 감소하였다. 직경이 다른 두 종류 삼상유동층에서 유효부피흐름속도를 매개로 한 규모인자는 기체유속과 유동입자의 크기가 증가함에 따라 감소하였으나 액체의 유속이 증가함에 따라 증가하였다. 본 연구에서 정의된 규모인자는 삼상유동층 공정의 수력학적 유사성을 해석하는데 효과적으로 사용될 수 있었다.

삼상유동층에서 동력학적 기체유출 측정방법에 의한 큰 기포와 작은 기포의 체류량 특성 해석 (Analysis of Holdup Characteristics of Large and Small Bubbles in Three-Phase Fluidized Beds by using a Dynamic Gas Disengagement Method)

  • 임현오;임대호;서명재;강용;정헌;이호태
    • Korean Chemical Engineering Research
    • /
    • 제49권5호
    • /
    • pp.605-610
    • /
    • 2011
  • 내경이 0.105 m이고 높이가 2.5 m인 삼상(기체-액체-고체) 유동층에서 상대적으로 큰 기포와 작은 기포의 체류량 특성을 고찰하였다. 기체유속(0.01~0.07 m/s), 액체유속(0.01~0.07 m/s) 그리고 입자크기($0.5{\sim}3.0{\times}10^{-3}m$)가 상대적으로 큰 기포와 작은 기포의 체류량에 미치는 영향을 검토하였다. 삼상 유동층에서 이들 두 종류 기포들의 체류량은 동력학적 기체 유출 방법(Dynamic gas disengagement method)에 의해 측정된 각각 기포들에 의한 압력강하 정보로부터 정압강하법(static pressure drop method)에 의해 산출되었다. 기체조절기에 의해 조절되는 건조되고 여과된 공기와 물 그리고 밀도가 2,500 $kg/m^3$인 유리구슬을 각각 기체, 액체 및 고체유동입자로 사용하였다. 삼상유동층에서 이들 두 종류의 기포, 즉 상대적으로 큰 기포와 작은 기포들은 유동층 탑에 유입되는 기체와 액체의 흐름을 정지시킨 후 경과시간에 따른 탑 내부의 압력강하를 측정함으로써 효과적으로 조사하고 분리할 수 있었다. 이들 두 종류의 기포들은 경과시간에 따라 증가하는 압력강하의 기울기가 서로 매우 다르게 나타났다. 실험결과 상대적으로 큰 기포들의 체류량은 기체의 유속이 증가함에 따라 증가하였으나 액체의 유속이 증가함에 따라서는 감소하였다. 그러나, 이들 큰 기포의 체류량은 유동입자의 크기가 변화함에 따라 국부적인 최소값을 나타내었다. 상대적으로 작은 기포들의 체류량은 기체유속 또는 고체입자의 크기가 증가함에 따라 증가하였으나 액체의 유속이 증가함에 따라서는 약간 감소하였다. 이들 두 종류 기포들의 체류량들은 각각 본 연구의 실험 범위 내에서 조작변수들의 상관식으로 나타낼 수 있었다.

기포탑에서 작은기포와 큰기포의 크기 구별 (Size Verification of Small and Large Bubbles in a Bubble Column)

  • 서명재;진해룡;임대호;임호;강용;전기원
    • Korean Chemical Engineering Research
    • /
    • 제50권2호
    • /
    • pp.304-309
    • /
    • 2012
  • 동력학적 기체유출방법(dynamic gas disengagement method)과 이중전기저항 탐침방법(dual electrical resistivity probe method)을 동시에 사용하여 기포탑에서 큰 기포와 작은 기포의 크기를 구별하였다. 기포탑의 일정한 운전조건에서 기포탑 내부에 체류하는 큰 기포와 작은 기포의 체류량은, 기포탑에 유입되는 기체의 유입을 차단한 후 시간의 흐름에 따른 기포탑 내부의 압력강하 변화를 측정하여 동력학적 기체유출방법에 의해 측정하였다. 기포의 크기와 빈도수는 동력학적 기체유출방법에 의해 큰 기포와 작은 기포의 체류량을 측정하는 동일한 운전조건에서 측정하였으며 이들 자료들로부터 기포의 크기에 따른 기포의 체류량을 결정하였다. 기포탑에서 큰 기포와 작은 기포의 크기결정은 동력학적 기체유출방법에 의해 얻은 큰 기포와 작은 기포의 체류량과 이중전기저항 탐침법에 의해 구한 크기의 범위를 아는 기포들의 체류량을 비교하여 결정하였다. 여과된 압축 공기와 물을 기체상과 연속액상을 사용하였으며, 기포탑의 직경은 0.102 m이고 높이는 1.5 m이었다. 기포탑에서 큰 기포와 작은 기포의 경계 크기는 4.0~5.0 mm 이었는데, 기체의 유속이 낮은 범위에서는 큰 기포와 작은 기포의 경계 크기가 5.0 mm 정도이었으나 기체의 유속이 상대적으로 큰 범위에서는 큰 기포와 작은 기포의 경계 크기가 4.0 mm 정도가 되었다.