• Title/Summary/Keyword: Pressure stimulation

Search Result 326, Processing Time 0.029 seconds

Immediate Effect of Neuromuscular Electrical Stimulation on Balance and Proprioception During One-leg Standing

  • Je, Jeongwoo;Choi, Woochol Joseph
    • Physical Therapy Korea
    • /
    • v.29 no.3
    • /
    • pp.187-193
    • /
    • 2022
  • Background: Neuromuscular electrical stimulation (NMES) is a physical modality used to activate skeletal muscles for strengthening. While voluntary muscle contraction (VMC) follows the progressive recruitment of motor units in order of size from small to large, NMES-induced muscle contraction occurs in a nonselective and synchronous pattern. Therefore, the outcome of muscle strengthening training using NMES-induced versus voluntary contraction might be different, which might affect balance performance. Objects: We examined how the NMES training affected balance and proprioception. Methods: Forty-four young adults were randomly assigned to NMES and VMC group. All participants performed one-leg standing on a force plate and sat on the Biodex (Biodex R Corp.) to measure balance and ankle proprioception, respectively. All measures were conducted before and after a training session. In NMES group, electric pads were placed on the tibialis anterior, gastrocnemius, and soleus muscles for 20 minutes. In VMC group, co-contraction of the three muscles was conducted. Outcome variables included mean distance, root mean square distance, total excursion, mean velocity, 95% confidence circle area acquired from the center of pressure data, and absolute error of dorsi/plantarflexion. Results: None of outcome variables were associated with group (p > 0.35). However, all but plantarflexion error was associated with time (p < 0.02), and the area and mean velocity were 37.0% and 18.6% lower in post than pre in NMES group, respectively, and 48.9% and 16.7% lower in post than pre in VMC group, respectively. Conclusion: Despite different physiology underlying the NMES-induced versus VMC, both training methods improved balance and ankle joint proprioception.

Tactile Sensation Display with Electrotactile Interface

  • Yarimaga, Oktay;Lee, Jun-Hun;Lee, Beom-Chan;Ryu, Je-Ha
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2005.06a
    • /
    • pp.145-150
    • /
    • 2005
  • This paper presents an Electrotactile Display System (ETCS). One of the most important human sensory systems for human computer interaction is the sense of touch, which can be displayed to human through tactile output devices. To realize the sense of touch, electrotactile display produces controlled, localized touch sensation on the skin by passing small electric current. In electrotactile stimulation, the mechanoreceptors in the skin may be stimulated individually in order to display the sense of vibration, touch, itch, tingle, pressure etc. on the finger, palm, arm or any suitable location of the body by using appropriate electrodes and waveforms. We developed an ETCS and investigated effectiveness of the proposed system in terms of the perception of roughness of a surface by stimulating the palmar side of hand with different waveforms and the perception of direction and location information through forearm. Positive and negative pulse trains were tested with different current intensities and electrode switching times on the forearm or finger of the user with an electrode-embedded armband in order to investigate how subjects recognize displayed patterns and directions of stimulation.

  • PDF

Experimental study on the changes of serum free fatty acid and blood sugar during hemorrhagic shock (출혈성(出血性) Shock 에 출현(出現)되는 유리지방산(遊離脂肪酸) 및 혈당량(血糖量)의 변동(變動)에 관(關)하여)

  • Kim, Hyong-Se
    • The Korean Journal of Pharmacology
    • /
    • v.2 no.1 s.2
    • /
    • pp.99-109
    • /
    • 1966
  • It has been known that the pronounced hypotension resulting from hemorrhage gives rise to compensatory stimulation of the adrenosympathetic system, which leads to an increase of liberation of catecholamines from sympathetic nervous system and adrenal medulla. It is obvious, therefore, that numerous physiological and biochemical changes during the hemorrhagic hypotention might be mediated through the increased liberation of catecholamines. Although an extensive studies have been reported on changes of protein and carbohydrate metabolism in hemorrhagic shock a few studies on the changes of lipid metabolism have been reported. Levenson(1961) observed a marked increase of serum lipids content during hemorrhagic shock and also noticed a marked elevation of serum free fatty acids. He suggested that these effects were due to mobilization and accelerated metabolic breakdown of lipids which might be resulted by sympathetic stimulation as a cause. To elucidate the mechanism of this, author studied the change of serum free fatty acids and blood sugar with relation to catecholamines during experimentally induced hemorrhagic shock in dog. Healthy male mongrel dogs weighing approximately 15kg were used. Under the general anesthesia with pentobarbital, rapid hemorrhage was produced from the femoral artery maintaining blood pressure level of 40 mmHg measured by the manometer connected with the opposite femoral artery throughout the experiment. Serum free fatty acids(FFA) and blood sugar were measured by the methods of Dole(1956) and Folin-wu,(1920) respectively. Tissue catecholamine was measured by Shore and Olin method(1958) using Aminco-Bowman spectrophotofluorometer.

  • PDF

Effect of Weight Shift Training with Electrical Sensory Stimulation Feedback on Standing Balance in Stroke patients

  • Kim, Da-young;Cha, Yong-jun
    • Journal of the Korean Society of Physical Medicine
    • /
    • v.10 no.3
    • /
    • pp.39-45
    • /
    • 2015
  • PURPOSE: The purpose of this study was to investigate the effect of weight shift training with electrical sensory simulation feedback on quiet standing balance in hemiplegic stroke patients. METHODS: 30 stroke patients were equally allocated at random to an experimental group or a control group. Patients in both two groups underwent comprehensive rehabilitation physical therapy for 30 minutes per day for 5 days per week for 4 weeks. Members of the experimental group received additional weight shift training with electrical sensory simulation feedback was conducted for 15 minutes after 30 minute sessions, whereas members of the control group underwent additional leftward/rightward weight shift training by themselves after 30 minutes per day for four weeks. COP (center of pressure) path lengths, COP velocities, and foot forces were measured before and immediately after the 4-week training period in both groups and results were compared. RESULTS: COP path lengths significantly decreased by 3% after training in the experimental group and this was significantly greater than that observed in the control group (p<0.05). In both groups, foot forces of affected sides showed significant increases after intervention, whereas foot forces of unaffected sides showed significant decreases (p<0.05). No significant difference was observed between the two groups with respect to these changes. CONCLUSION: Weight shift training using electrical sensory simulation feedback has a positive effect on quiet standing balance in hemiplegic stroke.

Effects of Bridging Exercise using Vibration Stimulation and ADIMs on the Lengthening and Thickness of Transversus Abdominis in Healthy Adults

  • Kong, Kwan-Woo
    • The Journal of Korean Physical Therapy
    • /
    • v.28 no.6
    • /
    • pp.393-397
    • /
    • 2016
  • Purpose: This study was conducted in an effort to determine the effects of various abdominal drawing-in maneuver (ADIM) on the thickness and length of the transversus abdominis (TrA) when using lumbar stabilization exercises on healthy adults. Methods: 72 healthy adults were divided into four groups of 18 subjects each, to which different ADIM methods were applied. 1) a simple ADIM exercise, 2) an ADIM with pressure bio-feedback units, 3) an ADIM exercise with sling, and 4) an ADIM exercise with sling and vibration. Changes in the thickness and sliding length of TrA were measured when ADIM was conducted in the supine position prior to exercise and again when beginning the exercises. Following exercise, changes in the thickness and sliding length of TrA were measured using the same methods. Differences in group measurements prior to and following exercise were compared using a one-way analysis of variance. A paired t-test was applied to compare the before and after differences within each group. Results: Differences in TrA thickness change revealed that the ADIM exercise with sling and vibration group showed a significant difference in measurements taken prior to and following exercise. Differences in TrA length change revealed that the ADIM exercise with sling and vibration group showed a significant difference in measurements taken prior to and following exercise. Conclusion: ADIM exercise with vibration stimulation conducted in the bridge posture while in a prone position using a sling can be recommended as an effective exercise to improve the function of lumbar TrA.

Comparison of the effects of transcutaneous electrical nerve stimulation, low level laser, and placebo treatment on temporomandibular joint disorders: a single-blind randomized controlled trial

  • Kim, Hyunjoong
    • Physical Therapy Rehabilitation Science
    • /
    • v.9 no.4
    • /
    • pp.244-251
    • /
    • 2020
  • Objective: Physical therapy techniques are required for patients with temporomandibular joint disorder (TMD), but the effects of treatment have not been compared. Therefore, effects of transcutaneous electrical nerve stimulation (TENS) and low level laser (LLL), which are most commonly used interventions, were compared. Design: Randomized controlled trial. Methods: Thirty-six participants with pain in the temporomandibular joint were enrolled, and 12 participants were randomly assigned to either the TENS group, LLL group, or placebo group. Each intervention was performed for a total of 6 sessions for 2 weeks. For the evaluation of the participants, the mouth opening (MO), pressure pain threshold (PPT), and stress were measured at three time periods: baseline, post-test, and follow-up at 2 weeks. Results: Significant interaction between groups according to each evaluation point was found only in PPT-masseter (p<0.05). The evaluation time point at which a significant difference appeared was at the post-test and follow-up at 2 weeks time periods. As a result of the post-test, the LLL group showed a significant improvement compared to the TENS group (p<0.05), and at 2 weeks follow-up, the TENS group showed a significant improvement compared to the placebo group (p<0.05). Conclusions: In this study, an experiment was conducted to compare the treatment effects when TENS, LLL, and placebo were given to patients with TMD. In addition, by quantitatively presenting the effect size of each treatment, this study suggests clinical use of TENS and LLL treatment for TMD.

The Effects of Stimulation of Acupuncture Point ST36 on Disuse Muscle Atrophy in Rats (흰쥐 발목관절고정으로 유발된 장딴지근 위축에 경혈점 자극이 미치는 효과)

  • Kim, Bumhoi;Lee, Taesik
    • Journal of The Korean Society of Integrative Medicine
    • /
    • v.6 no.4
    • /
    • pp.75-82
    • /
    • 2018
  • Purpose : The present study tested the hypothesis that acupressure at Zusanli(ST36) would attenuate immobilization-induced skeletal muscle atrophy. Methods : The left hind limb was immobilized using casting tape (ST36 group, n=10), and the animals were then treated daily with a pressure needle at ST36. Ten untreated animals with hind limb immobilization and no treatment served as a control group (n=10). After 2 weeks of immobilization, The body weight changes of rats were evaluated and the morphologies of the right and left gastrocnemius muscles in both the ST36 and control groups were assessed by hematoxylin and eosin staining. The levels of malondialdehyde (MDA) of gastrocnemius muscles were observed. Results : The acupressure at the accupoint of Zusanli conferred significant protection against reductions in left gastrocnemius muscle weights and average cross-sectional muscle areas in the ST36 group as compared with those in the control group. Moreover, the acupressure at the ST36 point significantly reduced malondialdehyde (MDA) activity in the gastrocnemius muscles as compared with that in the control group. Conclusion : These results suggest that acupressure at the accupoint of Zusanli provides protection against immobilization-induced muscle atrophy by decreasing MDA activity in gastrocnemius muscles.

Ameliorative Potential of Rengyolone Against CCI-induced Neuropathic Pain in Rats

  • Lee, Gil-Hyun;Hyun, Kyung-Yae
    • Biomedical Science Letters
    • /
    • v.26 no.4
    • /
    • pp.310-318
    • /
    • 2020
  • The sciatic nerve is the largest nerve among the peripheral nerves, and the damage to the sciatic nerve is caused by mechanical and physical pressure. This is an important disease that consumes a lot of time and money in the treatment process. Among them, research on relieving nerve pain caused by damage to the peripheral sciatic nerve has been made efforts to prevent and treat this disease through various methods such as drugs, natural products, electrical stimulation, exercise therapy, and massage. Existing treatments are not very effective in neurological pain, and countermeasures are needed. Forsythia Fructus, used in this study, has been used as a therapeutic agent for infectious diseases and a pain reliever for cancer from the past, and in past studies, it has been known to properly control the inflammatory response. In this study, rengyolone, a physiologically active substance of Forsythiae Fructus, was administered to rats that caused chronic left nerve pain to verify the pain relief effect. As a result of the experiment, it was found that mechanical pain and cold stimulation pain were significantly reduced in the rengyolone-treated group compared to the non-administered group. In addition, it was found that nerve growth factor (NGF) mRNA expression was significantly reduced and Cyclin-dependent kinase 2 (Cdc2) expression was increased in the rengyolone administration group. This increase in NGF expression is thought to be related to rengyolone's anti-inflammatory regulatory mechanism. It is expected that the reduced NGF was directly involved in pain relief.

A Study on the Electronic Properties of Poly-$\gamma$ Benzyl $_D$-Glutamate Organic Thin Films (Poly-${\gamma}$ Benzyl $_D$-Glutamate 유기박막의 전자이동특성에 관한 연구)

  • Song, Jin-Won;Lee, Kyung-Sup;Lee, Bong-Ju;Gu, Hal-Bon
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2002.05b
    • /
    • pp.86-89
    • /
    • 2002
  • We give pressure stimulation into organic thin films and then manufacture a device under the accumulation condition that the state surface pressure is 10[mN/m]. In processing of a device manufacture, we can see the process is good from the change of a surface pressure for organic thin films and transfer ratio of area per molecule. The structure of manufactured device is Au/Poly-${\gamma}$ Benzyl $_D$-Glutamate/Al and Au/Poly-${\gamma}$ Benzyl $_D$-Glutamate/Au; the number of accumulated layers is 1, 3, 5 and 7. Also, we then examined of the MIM device by means of I-V. The I-V characteristic of the device is measured from 0 to +2[V]. We determined electrochemical measurement by using cyclic voltammetry with a three-electrode system. LB film accumulated by monolayer on an ITO. In the cyclicvoltammetry, An Ag/AgCl reference electrode, a platinum wire counter electrode and LB film-coated ITO working electrode measured in $LiBF_4$ solution, stable up to 0.9V vs. Ag/AgCl.

  • PDF

A Study on the Interface Properties of Metal/Organic Films/Metal (Metal/Organic Films/Metal에서 계면특성에 관한 연구)

  • Song, Jin-Won;Cho, Su-Young;Choi, Young-Il;Lee, Kyung-Sup
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2002.07b
    • /
    • pp.723-726
    • /
    • 2002
  • We give pressure stimulation into organic thin films and then manufacture a device under the accumulation condition that the state surface pressure is 10[mN/m]. In processing of a device manufacture, we can see the process is good from the change of a surface pressure for organic thin films and transfer ratio of area per molecule. The structure of manufactured device is Au/Poly-$\gamma$ Benzyl $_D$-Glutamate/Al; the number of accumulated layers is 1, 3, 5 and 7. Also, we then examined of the MIM device by means of I-V. The I-V characteristic of the device is measured from 0 to +2[V]. We determined electrochemical measurement by using cyclic voltammetry with a three-electrode system. LB film accumulated by monolayer on an ITO. In the cyclicvoltammetry, An Ag/AgCl reference electrode, a platinum wire counter electrode and LB film-coated ITO working electrode measured in $LiBF_4$ solution, stable up to 0.9V vs. Ag/AgCl.

  • PDF