• Title/Summary/Keyword: Pressure monitoring

Search Result 1,102, Processing Time 0.022 seconds

A Study on the Risk Assessment of River Crossing Pipeline in Urban Area (도심지 하천매설배관의 위험성 평가에 관한 연구)

  • Park, Woo-Il;Yoo, Chul-Hee;Shin, Dong-Il;Kim, Tae-Ok;Lee, Hyo-Ryeol
    • Journal of the Korean Institute of Gas
    • /
    • v.24 no.2
    • /
    • pp.22-28
    • /
    • 2020
  • In this study, quantitative risk assessment was carried out for city gas high-pressure pipelines crossing through urban rivers. The risk assessment was performed based on actual city gas properties, traffic volume and population and weather data in the worst case scenario conditions. The results confirmed that the social and individual risks were located in conditionally acceptable areas. This can be judged to be safer considering that the risk mitigation effect of protecting the pipes or installing them in the protective structure at the time of the construction of the river buried pipe is not reflected in the result of the risk assessment. Also, SAFETI v8.22 was used to analyze the effects of wind speed and pasquil stability on the accident damage and dispersion distances caused by radiation. As a result of the risk assessment, the safety of the pipelines has been secured to date, but suggests ways to improve safety by preventing unexpected accidents including river bed changes through periodic inspections and monitoring.

Meteorological Characteristics of High-Ozone Episode Days in Daegu, Korea (대구시의 고농도 오존 발생 일에 나타나는 기상학적 특성)

  • Son, Im-Young;Kim, Hee-Jong;Yoon, Ill-Hee
    • Journal of the Korean earth science society
    • /
    • v.23 no.5
    • /
    • pp.424-435
    • /
    • 2002
  • This study analyzes the surface ozone and meteorological data in Daegu for a period from 1997 to 1999. It also investigates the meteorological characteristics of high ozone episodes. For this study the high ozone episode has been defined as a daily maximum ozone concentration higher than 100ppb in at least one station among six air quality monitoring stations in Daegu, Korea. The frequency of episodes is 13 days. The frequency is the highest in May and September. The average value of daily maximum ozone concentration is 81.6ppb, and 8-hour average ozone concentration is 58.6ppb for the high episodes. This shows that ozone pollution is continuous and wide-ranging in Daegu. The daily maximum ozone concentration is positively correlated to solar radiation and daily maximum temperature, but negatively correlated to relative humidity, wind speed and cloud amount. The maximal correlation coefficient to solar radiation is 0.45. The differences between high ozone episode day's daily mean meteorological value and monthly mean value are +1.58hPa for sea level pressure, +3.45${\circ}$C for maximum temperature, -5.69% for relative humidity, -0.46ms$^{-1}$ for wind speed, -1.79 for cloud amount, and +3.97MJm$^{-2}$ for solar radiation, respectively. This shows that strong solar radiation, low wind speed and no precipitation between 0700${\sim}$1100LST are favorite conditions for high ozone episodes. It is related to the morning stagnant condition.

Suggestions for Safety Improvement of CNG Bus Based on Accident and Failure Analysis (CNG버스 사고원인 분석에 근거한 안전성 향상 방안에 대한 연구)

  • Yoon, Jae-Kun;Yoon, Kee-Bong
    • Journal of the Korean Institute of Gas
    • /
    • v.12 no.2
    • /
    • pp.69-76
    • /
    • 2008
  • Three failure cases of CNG composite vessels were reported since after January 2005. The 1st and 2nd accidents were indebted to vessel defect and installation mistake. The 3rd was caused by gas leak at pipe connections. In this paper various aspects were studied based on information of the three failure analysis, which must be improved for better safety of the CNG bus system. Overpressure region caused by vessel explosion was theoretically predicted and also assessed by PHAST program. Explosion of 120 l vessel under 20 MPa is equivalent to 1.2 kg TNT explosion. The predicted value by PHAST was more serious than theoretical one. However, actual consequence of explosion was much less than both of the predicted consequences. Since the CNG vessel was designed by the performance based design methodology, it is difficult to verify whether the required process and tests were properly conducted or not after production. If material toughness is not enough, the vessel should be weak in brittle fracture at early in the morning of winter season since the metal temperature can be lower than the transition temperature. If autofrettage pressure is not correct, fatigue failure due to tensile stress during repeated charging is possible. One positive aspect is that fire did not ocurred after vessel failure. This may be indebted to fast diffusion of natural gas which hindered starting fire.

  • PDF

Experiment and Assessment of Ascending Capability for Management of Exotic Fish Species (외래어종 관리를 위한 소상 실험 및 평가)

  • Kang, Joon-Gu;Kim, Jong-Tae
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.17 no.9
    • /
    • pp.265-278
    • /
    • 2016
  • In this study, an ascending capability experiment was performed with largemouth bass and bluegill, which are exotic fish species inhabiting (the freshwaters) in Korea. The experiment was performed by dividing the subject fish into four groups according to their size and at four flow rates for each group. The number of fish passing through a reference line was analyzed by recording videos, and their swimming and ascending capabilities were observed by the naked eye. The number of fish passing through the reference line did not include those returning downstream within five minutes due to the high flow rate. The flow rate used for the analysis was the mean of the flow rate values measured at the left bank, the right bank, and in the middle of the stream. The results showed that the number of exotic fish migrating upstream decreased as the flow rate increased, regardless of the species and size of the fish. The comparison between the fish species showed that the ascending capability of bass was higher than that of bluegill, but the difference was not significant when considering the difference in the size of the fish. In addition, the upper limit flow velocity allowing the ascending of the exotic fish species was 1.11 m/s, when considering the fish returning to the downstream after the upstream migration and experimental error. The results of the experiment may be used as fundamental data for the blocking of fish and the management of exotic fish species by means of a high flow rate current. Further experiments, verification, and monitoring may need to be conducted continuously to determine whether the fish are able to pass through the reference line at a high flow rate, when they attain a high or cruising velocity. Additionally, the reaction of the fish species should be investigated by considering the response to external forces as well as pressure differences due to the flow rate.

Contents Analysis on the Image of Nurses in the Television Drama (텔레비전 드라마의 간호사 이미지에 대한 분석)

  • Moon, Young-Im;Im, Mi-Lim;Yun, Kyung-Yi
    • The Korean Nurse
    • /
    • v.37 no.2
    • /
    • pp.44-52
    • /
    • 1998
  • The purpose of this study is to inquire the people's views on nursing for nurses, correct the image of nurse and take it as basis to be applied on nursing education examining the image of nursing on Television drama playing important role of mass media. 22 nurses of the characters in drama is applied to the analysis object of this study by selecting 6 dramas of Television ones the nurse play on the prime time from June 1 to August 31 in 1997. Contents analysis method was used in Data Analysis, 4 items was used after Coders previously modify and compensate it based on research documents of 1m Milim(1996) 2 Coders made the Coding the article on each person by them seeing the recorded film making the Coding Paper each items is written by the character. The average of reliability degree was 90% which measured the reliability degree by the mathod of Holsti. The statisic method of frequency, percentage was used SPSS Program in data processing The results were as follows. 1. Relative importance of 86.2% nurses in drama was depicted as extra characters 2. The affair attitude of nurses shown on drama was revealed as mechanical(84.7%), passive(45.5%), dependent(54.4%) unkind(68.2%). 3. The activity of nurses was classified with professional! simple affair. The professional affairs such as I.V., Blood Pressure Check, Rounding, Nursing Recording, Patient Education, Assist of Operation, Assistant meal of Patient, etc is mainly depicted and the screen of simple affair such as Receiving telephone, Carrying Tray or Dragging, Stretcher Car, Dressing Car and or Wheel Chair than professional affair. 4. The appearance feature of nurses was shown on thin physique(68.2%), common stature(68.2), dirty costume(45.4%), common appearance(81.9%), unnoble action(63.6%). The image of nurses is illuminated as the exterial scene of technical affair such as assisting the doctors and affair focused on accident and educational activity of nureses or extended role is nor depicted on Television drama. Therefore, the people regard the nurse as sexual object with good appearance than professional worker working professional nursing We want the following, epigraph based on above conclusion. 1. The continuous research is required on the image of nurse shown on various mass media. 2. The later research is required on appliction strategy of mass media for advancing the image of nurse. 3. The research to strengthen the objectivity by comparing analyzed data on drama & analyzing it is required 4. Through the deep study, the standard to show a concrete and professional work of nurses to scenario writers of TV drama is suggested by the association. 5. The monitoring about the mass media must be activated, not by some nurses, on a national scale and much study on the basis of this is needed.

  • PDF

Active Water-Level and Distance Measurement Algorithm using Light Beam Pattern (광패턴을 이용한 능동형 수위 및 거리 측정 기법)

  • Kim, Nac-Woo;Son, Seung-Chul;Lee, Mun-Seob;Min, Gi-Hyeon;Lee, Byung-Tak
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.52 no.4
    • /
    • pp.156-163
    • /
    • 2015
  • In this paper, we propose an active water level and distance measurement algorithm using a light beam pattern. On behalf of conventional water level gauge types of pressure, float-well, ultrasonic, radar, and others, recently, extensive research for video analysis based water level measurement methods is gradually increasing as an importance of accurate measurement, monitoring convenience, and much more has been emphasized. By turning a reference light beam pattern on bridge or embankment actively, we suggest a new approach that analyzes and processes the projected light beam pattern image obtained from camera device, measures automatically water level and distance between a camera and a bridge or a levee. As contrasted with conventional methods that passively have to analyze captured video information for recognition of a watermark attached on a bridge or specific marker, we actively use the reference light beam pattern suited to the installed bridge environment. So, our method offers a robust water level measurement. The reasons are as follows. At first, our algorithm is effective against unfavorable visual field, pollution or damage of watermark, and so on, and in the next, this is possible to monitor in real-time the portable-based local situation by day and night. Furthermore, our method is not need additional floodlight. Tests are simulated under indoor environment conditions from distance measurement over 0.4-1.4m and height measurement over 13.5-32.5cm.

Effect of coadministration of enriched Korean Red Ginseng (Panax ginseng) and American ginseng (Panax quinquefolius L) on cardiometabolic outcomes in type-2 diabetes: A randomized controlled trial

  • Jovanovski, Elena;Smircic-Duvnjak, Lea;Komishon, Allison;Au-Yeung, Fei (Rodney);Sievenpiper, John L.;Zurbau, Andreea;Jenkins, Alexandra L.;Sung, Mi-Kyung;Josse, Robert;Li, Dandan;Vuksan, Vladimir
    • Journal of Ginseng Research
    • /
    • v.45 no.5
    • /
    • pp.546-554
    • /
    • 2021
  • Background: Diabetes mellitus and hypertension often occur together, amplifying cardiovascular disease (CVD) risk and emphasizing the need for a multitargeted treatment approach. American ginseng (AG) and Korean Red Ginseng (KRG) species could improve glycemic control via complementary mechanisms. Additionally, a KRG-inherent component, ginsenoside Rg3, may moderate blood pressure (BP). Our objective was to investigate the therapeutic potential of coadministration of Rg3-enriched Korean Red Ginseng (Rg3-KRG) and AG, added to standard of care therapy, in the management of hypertension and cardiometabolic risk factors in type-2 diabetes. Methods: Within a randomized controlled, parallel design of 80 participants with type-2 diabetes (HbA1c: 6.5-8%) and hypertension (systolic BP: 140-160 mmHg or treated), supplementation with either 2.25 g/day of combined Rg3-KRG + AG or wheat-bran control was assessed over a 12-wk intervention period. The primary endpoint was ambulatory 24-h systolic BP. Additional endpoints included further hemodynamic assessment, glycemic control, plasma lipids and safety monitoring. Results: Combined ginseng intervention generated a mean ± SE decrease in primary endpoint of 24-h systolic BP (-3.98 ± 2.0 mmHg, p = 0.04). Additionally, there was a greater reduction in HbA1c (-0.35 ± 0.1% [-3.8 ± 1.1 mmol/mol], p = 0.02), and change in blood lipids: total cholesterol (-0.50 ± 0.2 mmol/l, p = 0.01), non-HDL-C (-0.54 ± 0.2 mmol/l, p = 0.01), triglycerides (-0.40 ± 0.2 mmol/l, p = 0.02) and LDL-C (-0.35 ± 0.2 mmol/l, p = 0.06) at 12 wks, relative to control. No adverse safety outcomes were observed. Conclusion: Coadministration of Rg3-KRG + AG is an effective addon for improving BP along with attaining favorable cardiometabolic outcomes in individuals with type 2 diabetes. Ginseng derivatives may offer clinical utility when included in the polypharmacy and lifestyle treatment of diabetes. Clinical trial registration: Clinicaltrials.gov identifier, NCT01578837;

Sternal Retraction and Subclavian Vein Catheter Occlusion during Cardiac Surgery

  • Tarbiat, Masoud;Bakhshaei, Mohammad Hossein;Derakhshanfar, Amir;Rezaei, Mahmoud;Ghorbanpoor, Manoochehr;Zolhavarieh, Seyed Mohammad
    • Journal of Chest Surgery
    • /
    • v.54 no.5
    • /
    • pp.377-382
    • /
    • 2021
  • Background: Subclavian vein (SV) catheterization is a method for the delivery of fluids, drugs, and blood products, venous blood sampling, and central vein pressure monitoring in cardiac surgery. Catheter occlusion is a serious complication of SV catheterization during cardiac surgery, especially after sternal retractor expansion. Methods: In this observational study, 303 patients who had successful right infraclavicular SV catheterization from September 2019 to April 2020 were enrolled to determine the incidence of catheter occlusion. After catheterization, the lumens of all catheters were checked for the ability to infuse and withdraw blood from the catheter before and after sternal retractor expansion. The patients' characteristics, cannulation approach, on-pump or off-pump technique, occlusion of the catheter and its lumens, and any associated complications were recorded. The data were analyzed using IBM SPSS ver. 22.0 (IBM Corp., Armonk, NY, USA). Results: Of the 303 patients studied, 205 were male (67.7%) and 98 were female (32.3%). Catheter occlusion occurred in 11 patients with on-pump cardiopulmonary bypass (CPB) (227 patients) and 4 patients with off-pump CPB (76 patients) (p=0.863). The incidence of catheter occlusion was 4.95% (15 of 303 patients) with no cases of simultaneous 3-lumen occlusion in a catheter. The most commonly occluded lumen was the distal lumen (57.92%). Simultaneous 2-lumen occlusion occurred in 4 patients. Catheter occlusion was found in 3 of 13 malpositioned catheters (23.07%). Conclusion: The current study showed that malpositioning of the catheter tip was a risk factor for catheter occlusion and that the distal lumen of a triple-lumen catheter was the most commonly occluded lumen.

Changes of carbon-13 Isotope of Dissolved Inorganic Carbon Within Low-pH CO2-rich Water during CO2 Degassing (pH가 낮은 탄산수의 CO2 탈기에 따른 용존탄소동위원소 변화)

  • Chae, Gitak;Yu, Soonyoung;Kim, Chan Yeong;Park, Jinyoung;Bang, Haeun;Lee, Inhye;Koh, Dong-Chan;Shinn, Young Jae;Oh, Jinman
    • Journal of Soil and Groundwater Environment
    • /
    • v.24 no.3
    • /
    • pp.24-35
    • /
    • 2019
  • It is known that ${\delta}^{13}C_{DIC}$ (carbon-13 isotope of dissolved inorganic carbonate (DIC) ions) of water increases when dissolved $CO_2$ degases. However, ${\delta}^{13}C_{DIC}$ could decrease when the pH of water is lower than 5.5 at the early stage of degassing. Laboratory experiments were performed to observe the changes of ${\delta}^{13}C_{DIC}$ as $CO_2$ degassed from three different artificial $CO_2$-rich waters (ACWs) in which the initial pH was 4.9, 5.4, and 6.4, respectively. The pH, alkalinity and ${\delta}^{13}C_{DIC}$ were measured until 240 hours after degassing began and those data were compared with kinetic isotope fractionation calculations. Furthermore, same experiment was conducted with the natural $CO_2$-rich water (pH 4.9) from Daepyeong, Sejong City. As a result of experiments, we could observe the decrease of DIC and increase of pH as the degassing progressed. ACW with an initial pH of 6.4, ${\delta}^{13}C_{DIC}$ kept increasing but, in cases where the initial pH was lower than 5.5, ${\delta}^{13}C_{DIC}$ decreased until 6 hours. After 6 hours ${\delta}^{13}C_{DIC}$ increased within all cases because the $CO_2$ degassing caused pH increase and subsequently the ratio of $HCO_3{^-}$ in solution. In the early stage of $CO_2$ degassing, the laboratory measurements were well matched with the calculations, but after about 48 hours, the experiment results were deviated from the calculations, probably due to the equilibrium interaction with the atmosphere and precipitation of carbonates. The result of this study may be not applicable to all natural environments because the pressure and $CO_2$ concentration in headspace of reaction vessels was not maintained constant as well as the temperature. Nevertheless, this study provides fundamental knowledge on the ${\delta}^{13}C_{DIC}$ evolution during $CO_2$ degassing, and therefore it can be utilized in the studies about carbonated water with low pH and the monitoring of geologic carbon sequestration.

Performance Evaluation of a Portable GC for Real-time Monitoring of Volatile Organic Compounds (휘발성 유기화합물의 실시간 모니터링을 위한 휴대형 GC의 성능 평가)

  • You, Dong-Wook;Seon, Yeong-Sik;Oh, Jun-Sik;Yi, Bongyoon;Kim, Hyun Sik;Jung, Kwang-Woo
    • Journal of the Korean Chemical Society
    • /
    • v.64 no.6
    • /
    • pp.327-333
    • /
    • 2020
  • Performance of a portable GC that can be utilized for the real time determination of volatile organic compounds in air was evaluated. It employs purified/compressed ambient air as the carrier gas eliminating the need for high pressure gas tanks. The compact system with dimensions of 35 × 26 × 15 ㎤ and weight of 5 kg is powered by either a 24 V DC external adapter or battery pack. Chromatograms of the mixture sample including benzene, toluene, ethylbenzene, and oxylene at concentrations of 1 ppmv and 20 ppmv represent a good reproducibility: 3.79% and 0.48% relative standard deviations (RSDs) for peak area variations; 0.40% and 0.08% RSDs for retention times. The method detection limit was 0.09 ppmv. A 30 m long, 0.28 mm I.D. column operated at an optimal condition yielded a peak capacity of 61 with good resolution for a 10 min isothermal analysis. The relative standard deviations (RSD) of the peak area variations and retention times during consecutive measurements over 27 h were less than 2.4%RSD and 0.5%RSD, respectively. Thus, this instrument makes it suitable for continuous and field analysis of low-concentration VOC mixtures in the indoor/outdoor environment as well as the spillage accident of hazardous chemicals.