Effect of Simple VSD Repair on Doppler-Derived Right Ventricular Systolic Time Interval (심실중격결손 봉합이 우심실 수축기 시간 간격에 미치는 영향)

  • 정태은;이영환
    • Journal of Chest Surgery
    • /
    • v.32 no.2
    • /
    • pp.124-129
    • /
    • 1999
  • Background: Ventricular septal defect(VSD) that causes pulmonary hypertension increase right ventricular workload. Echocardiographic assessment of right ventricular systolic time interval (RVSTI) has been used to predict pulmonary artery pressure in various cardiopulmonary diseases. This study was undertaken in infants with simple VSD to observe the alteration of the right ventricular workload through the changes of RVSTI after repair of VSD. Material and Method: We evaluated heart rate, the ratio of the left atrium/aortic root diameter (LA/Ao), right ventricular pre-ejection period(RVPEP), right ventricular ejection time(RVET), and its ratio(RVPEP/RVET) as a predictor of right ventricular workload in 12 children with simple VSD. These were measured three times at the preoperative period, at the 3 month and between 6 month and 1 year(average 9.5${\pm}$1.8month) after repair of VSD by M-mode & Doppler echocardiograph from the pulmonic valve echogram. Result: Heart rate was decreased significantly after repair(137.1${\pm}$13.7 vs 114.4${\pm}$21.1 and 104.1${\pm}$10.2, p<0.01). LA/Ao ratio was decreased significantly after repair(1.71${\pm}$0.32 vs 1.47${\pm}$0.33 and 1.39${\pm}$0.23, p<0.05). RVPEP/RVET were decreased after repair (0.38${\pm}$0.09 vs 0.32${\pm}$0.08 and 0.29${\pm}$0.09, p<0.01). Heart rate corrected RVPEP/RVET were significantly decreased only after 6 months(0.32${\pm}$0.03 vs 0.30${\pm}$0.05 and 0.28${\pm}$0.06, p<0.05). Conclusion: We found elevated right ventricular workload was progressively decreased until more than 6 months after repair and the RVSTI may serve a useful guide in postoperative care for children with VSD.

  • PDF

Early and Midterm Results of Arterial Switch Operation for Double-Outlet Right Ventricle with Subpulmonary VSD (폐동맥하 심실증격결손을 동반한 양대혈관 우심실기시중에서 동맥전환술의 중단기 결과)

  • 양승인;이형두;김시호;조광조;우종수;이영석;성시찬
    • Journal of Chest Surgery
    • /
    • v.37 no.4
    • /
    • pp.313-321
    • /
    • 2004
  • Excellent clinical results of the arterial switch operation and the limited availablity of the intraventricular rerouting has recently made an arterial switch operation to become the therapeutic method of choice for the repair of double-outlet right ventricle (DORV) with subpulmonary ventricular septal defect (VSD). The early and midterm outcomes of arterial switch operation for this anomaly were evaluated. Material and Method: Between August 1994 and July 2002, 13 patients underwent an arterial switch operation for the correction of double-outlet right ventricle with subpulmonary VSD at Dong-A university hospital.. The 50% rule was used to define DORV. Median age and mean body weight were 27 days (range, 3-120 days) and 3.8$\pm$0.7kg (range, 2.92-5.3kg) respectively. Aortic arch anomalies were associated in 6 cases (46.2%), which were all repaired through one-stage operation. The relationship of the great arteries were side-by-side in 8 cases (61.5%) and anteroposterior in 5 (38.5%). Coronary artery patterns were 1 LCx-2R in 6 cases, retropulmonary left coronary artery (LCA) in 6, and intramural LCA in 1 respectively. The enlargement of VSD was required in 1 patient and the patch enlargement of right ventricular outflow tract was performed in another one patient. The Lecompte maneuver was used in all but 3 patients with a side by side relationship of the great arteries. Result: Overall postoperative hospital mortality was 23.1 % (3/13). All operative deaths were occurred in the patients with aortic arch anomalies. There was one late death related to the postoperative complication of the central nerve system during the mean follow-up of 41.3$\pm$30.7 months. Pulmonary valvar stenosis (>30mmHg of pressure gradient) developed in 1 patient (10%) and left pulmonary artery stenosis in 2 (20%), among them, one required reoperation 52 months after repair. There was an asymptomatic patient with moderate aortic regurgitation. 5-year survival rate including operative deaths was 68.3%. Conclusion: Although the operative mortality is high in the patients with aortic arch anomaly, the arterial switch operation for DORV with supbpulmonary VSD can be performed with low operative mortality and low reoperation rate in the patients Without arch anomaly. The arterial switch operation can be considered a good option for this complex anomaly.

Risk Factors Analysis and Results of the Arterial Switch Operation for Transposition of the Great Arteries with Intact Ventricular Septum (심실중격결손을 동반하지 않은 대혈관전위증 환자에서 동맥 전환술의 결과 및 위험인자 분석에 관한 연구)

  • 김용진;오삼세;이정렬;노준량;서경필
    • Journal of Chest Surgery
    • /
    • v.32 no.2
    • /
    • pp.108-118
    • /
    • 1999
  • Background: To evaluate the risk factor and long-term result of arterial switch operation , a retrospective study was done. Material and Method: A retrospective analysis was done to evaluate the early and long-term results on 58 patients who underwent an arterial switch operation(ASO) for transposition of the great arteries(TGA) with intact ventricular septum, between January 1988 and December 1996. Beforesurgery, 36 patients(62.1%) underwent balloon atrial septostomy, 32 patients(51.7%) received PGE1 infusion, and preparatory banding of pulmonary artery was performed on 6 patients(mean LV/RV pressure ratio 0.53$\pm$0.11). Result: The age at operation ranged from 1 to 137 days(mean 24$\pm$26 days) and the weights ranged from 1.8 to 6.8 kg (mean 3.5$\pm$0.8 kg). There were 14 early deaths(24.1%), but of the last 24 patients operated on since 1994, there were only 2 early deaths(8.3%). In the risk factor analysis, the date of operation was the only risk factor for early death(p-value < 0.01). Eight of the 14 early deaths were due to acute myocardial failure(mainly inadequate coronary blood flow). The length of follow-up ranged from 2 months to 8 years, average of 36$\pm$27 months. The follow-up included sequential noninvasive evaluations and 21 catheterizations and angiographic studies performed 5 to 32 months postoperatively with particular attention to the great vessel and coronary anastomosis, ventricular function, valvular competence, and cardiac rhythm. There were 5 late deaths(11.4%), one of thesedeaths was related to the late coronary problems, two to aspiration, one to uncontrolled chronic mediastinitis, and one to progressive aortic insufficiency and heart failure. The most frequent postoperative hemodynamic abnormality was supravalvular stenosis and the degree of pulmonary or aortic obstruction had slowly progressed in some cases, however there were no children who had to undergo a reoperation for supravalvular pulmonary or aortic stenosis. Aortic regurgitation was identified in 9 patients, which was mild in 7 and moderate in 2 and had progressed in some cases. Two patients who had an unremarkable perioperative course were identified as having coronary artery obstructions. The other late survivors were in good condition, were in sinus rhythm, and had normal LV functions. Actuarial survival rate at 8 years was 68.8%. Conclusion: We concluded that anatomic correction will be established as the optimal approach to the TGA with intact ventricular septum, though further long-term evaluations are needed.

  • PDF

Comparison of fatigue fracture strength by fixture diameter of mini implants (미니 임플란트 직경에 따른 피로파절강도의 비교 연구)

  • Heo, Yu-Ri;Son, Mee-Kyoung;Kim, Hee-Jung;Choe, Han-Cheol;Chung, Chae-Heon
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.50 no.3
    • /
    • pp.156-161
    • /
    • 2012
  • Purpose: This study was conducted to obtain difference in fracture strength according to the diameter of one-body O-ring-type of mini implant fixture, to determine the resistance of mini implant to masticatory pressure, and to examine whether overdenture using O-ring type mini implant is clinically usable to maxillary and mandibular edentulous patients. Materials and methods: For this study, 13 mm long one body O-ring-type mini implants of different diameters (2.0 mm, 2.5 mm and 3.0 mm) (Dentis, Daegu, Korea) were prepared, 5 for each diameter. The sample was placed at $30^{\circ}$ from the horizontal surface on the universal testing machine, and off-axis loading was applied until permanent deformation occurred and the load was taken as maximum compressive strength. The mean value of the 5 samples was calculated, and the compressive strength of implant fixture was compared according to diameter. In addition, we prepared 3 samples for each diameter, and applied loading equal to 80%, 60% and 40% of the compressive strength until fracture occurred. Then, we measured the cycle number on fracture and analyzed fatigue fracture for each diameter. Additionally, we measured the cycle number on fracture that occurred when a load of 43 N, which is the average masticatory force of complete denture, was applied. The difference on compressive strength between each group was tested statistically using one-way ANOVA test. Results: Compressive strength according to the diameter of mini implant was $101.5{\pm}14.6N$, $149{\pm}6.1N$ and $276.0{\pm}13.4N$, respectively, for diameters 2.0 mm, 2.5 mm and 3.0 mm. In the results of fatigue fracture test at 43 N, fracture did not occur until $2{\times}10^6$ cycles at diameter 2.0 mm, and until $5{\times}10^6$ cycles at 2.5 mm and 3.0 mm. Conclusion: Compressive strength increased significantly with increasing diameter of mini implant. In the results of fatigue fracture test conducted under the average masticatory force of complete denture, fracture did not occur at any of the three diameters. All of the three diameters are usable for supporting overdenture in maxillary and mandibular edentulous patients, but considering that the highest masticatory force of complete denture is 157 N, caution should be used in case diameter 2.0 mm or 2.5 mm is used.

A Clinical Analysis on the Restoration of Sinus Rhythm Following Mitral Valve Surgery (승모판 수술 후 동율동 회복에 관한 임상분석)

  • 백완기;심상석;김현태;조상록;진성훈
    • Journal of Chest Surgery
    • /
    • v.32 no.4
    • /
    • pp.347-352
    • /
    • 1999
  • Background: The atrial fibrillation in patients with mitral valvular heart disease is frequently converted to sinus rhythm after the mitral valve surgery. This sinus restoration implies an important meaning in that it not only helps postoperative convalescence in patients with unstable hemodynamics but also reduces the rate of postoperative thromboembolism. Material and Method: We retrospectively analyzed 184 patients who received mitral valve surgery from June 1986 to December 1996 to investigate the trend of rhythm change following mitral valve surgery and thus to clarify the predisposing factors of postoperative sinus rhythm conversion and its maintenance. Result: The sinus rhythm was restored after the operation in 54 out of 139 patients with atrial fibrillation preoperatively(38.8%). However, the atrial fibrillation recurred in 41 patients at the time of discharge showing a recurrence rate of 75.9 percent. The mean duration of sinus rhythm in patients with eventual atrial fibrillation recurrence was 8.2${\pm}$5.9 days. Only 15 patients were in sinus rhythm at the time of late follow-up with the mean follow-up period of 84.4${\pm}$34.7 months. While the age, duration of symptoms, duration of atrial fibrillation, left atral size, and pulmonary artery pressure were thought to be the predisposing factors for sinus conversion after the operation, only the duration of atrial fibrillation and ejection fraction were considered risk factors for the recurrence of the atrial fibrillation following sinus conversion. Conclusion: This study suggests that the early operation is mandatory for the satisfactory result regarding postoperative rhythm. Moreover, additional operative measure in adjunct to the intervention of mitral valve should be considered for the maintenance of restored sinus rhythm as reflected by high postoperative recurrence rate of atrial fibrillation.

  • PDF

The Changes of Cerebral Metabolic and Hemodynamic Parameters, Brain Histology, and Serum Levels of Neuron-Specific Enolase During Retrograde Cerebral Perfusion Under Pofound Hypothermic total Circulatory Arrest in Pigs (돼지에서 초저체온 순환정지 하의 역행성 뇌관류시 뇌대사, 혈류역학 지표, 뇌조직 소견 및 혈청 내 neuron-specific enolase의 변화)

  • Kim, Kyung-Hwan;Ahn, Hyuk
    • Journal of Chest Surgery
    • /
    • v.33 no.6
    • /
    • pp.445-468
    • /
    • 2000
  • Background: Retrograde cerebral perfusion(RCP) is currently used for brain protection during aorta surgery, however, for the safety of it, various data published so far are insufficient. We performed RCP using pig and investiaged various parameters of cerebral metabolism and brain injury after RCP under deep hypothermia. Material and Method: We used two experimental groups: in group I(7 pigs, 20 kg), we performed RCP for 120 minutes and in group II (5 pigs, 20 kg), we did it for 90 minutes. Nasopharyngeal temperature, jugular venous oxygen saturation, electroencephalogram were continuously monitored, and we checked the parameters of cerebral metabolism, histological changes and serum levels of neuron-specific enolose(NSE) and lactic dehydrogenase(LDH). Central venous pressure during RCP was mainained in the range of 25 to 30 mmHg. Result: Perfusion flow rates(ml/min) during RCP were 130$\pm$57.7(30 minutes), 108.6$\pm$55.2(60 minutes), 107.1$\pm$58.8(90 minutes), 98.6$\pm$58.7(120 minutes) in group I and 72$\pm$11.0(30 minutes), 72$\pm$11.0(60 minutes), 74$\pm$11.4(90 minutes) in group II. The ratios of drain flow to perfusion flow were 0.18(30 minutes), 0.19(60 minutes), 0.17(90 minutes), 0.16(120 minutes) in group I and 0.21, 0.20, 0.17 in group II. Oxygen consumptions(ml/min) during RCP were 1.80$\pm$1.37(30 minutes), 1.72$\pm$1.23(60 minutes), 1.38$\pm$0.82(90 minutes), 1.18$\pm$0.67(120 minutes) in group I and 1.56$\pm$0.28(30 minutes), 1.25$\pm$0.28(60 minutes), 1.13$\pm$0.26(90 minutes). We could observe an decreasing tendency of oxygen consumption after 90 minutes of RCP in group I. Cerebrovascular resistance(dynes.sec.cm-5) during RCP in group I incrased from 71370.9$\pm$369145.5 to 83920.9$\pm$49949.0 after the time frame of 90 minutes(p<0.05). Lactate(mg/min) appeared after 30 minutes of RCP and the levels were 0.15$\pm$0.07(30 minutes), 0.18$\pm$0.10(60 minutes), 0.19$\pm$0.19(90 minutes), 0.18$\pm$0.10(120 minutes) in group I and 0.13$\pm$0.09(30 minutes), 0.19$\pm$0.03(60 minutes), 0.29$\pm$0.11(90 minutes) in group II. Glucose utilization, exudation of carbon dioxide, differences of cerebral tissue acidosis between perfusion blood and drain blood were maintained constantly during RCP. Oxygen saturation levels(%) in drain blood during RCP were 22.9$\pm$4.4(30 minutes), 19.2$\pm$4.5(60 minutes), 17.7$\pm$2.8(90 minutes), 14.9$\pm$2.8(120 minutes) in group I and 21.3$\pm$8.6(30 minutes), 20.8$\pm$17.6(60 minutes), 21.1$\pm$12.1(90 minutes) in group II. There were no significant changes in cerebral metabolic parameters between two groups. Differences in serum levels of NSE and LDH between perfusion blood and drain blood during RCP showed no statistical significance. Serum levels of NSE and LDH after resuming of cardipulmonary bypass decreased to the level before RCP. Brain water contents were 0.73$\pm$0.03 in group I and 0.69$\pm$0.06 in group II and were higher than those of the controls(p<0.05). The light microscopic findings of cerebral neocortex, basal ganglia, hippocampus(CA1 region) and cerebellum showed no evidence of cerebral injury in two groups and there were no different electron microscopy in both groups(neocortex, basal ganglia and hippocampus), but they were thought to be reversible findings. Conclusion: Although we did not proceed this study after survival of pigs, we could perform the RCP successfully for 120 minutes with minimal cerebral metabolism and no evidence of irreversible brain damage. The results of NSE and LDH during and after RCP should be reevaluated with survival data.

  • PDF

The Clinical Outcome of Pulmonary Thromboendarterectomy for the Treatment of Chronic Pulmonary Thromboembolism (만성 폐동맥 색전증 환자에서의 폐동맥 내막절제술의 임상적 결과)

  • Bang, Jeong-Hee;Woo, Jong-Soo;Choi, Pil-Jo;Jo, Gwang-Jo;Park, Kwon-Jae;Kim, Si-Ho;Yie, Kil-Soo
    • Journal of Chest Surgery
    • /
    • v.43 no.3
    • /
    • pp.254-259
    • /
    • 2010
  • Background: Diagnosing chronic pulmonary embolism at an early stage is difficult because of the patient’s nonspecific symptoms. This condition is not prevalent in Korea, and in fact, there have been only a few case reports on this in the Korean medical literature. We analyzed the surgical outcome of performing pulmonary thromboendarterectomy in patients with chronic pulmonary embolism. Material and Method: The study subjects included those patients who underwent surgery for chronic pulmonary embolism from 1996 to 2008. For making the diagnosis, echocardiography, chest CT and a pulmonary perfusion scan were performed on the patients who complained of chronic dyspnea. Result: Pulmonary endarterectomy was performed as follows: by incision via a mid-sternal approach (7 patients); by incision via a left posterolateral approach (1 patient); using the deep hypothermic circulatory arrest technique (4 patients); under ventricular fibrillation (3 patients); and under cardioplegic arrest (1 patient). The postoperative systolic pulmonary artery blood pressure significantly decreased from a preoperative value of $78.9{\pm}14.5\;mmHg$ to $45.6{\pm}17.6\;mmHg$ postoperatively (p=0.000). The degree of tricuspid regurgitation was less than grade II after surgery. Two patients died early on, including one patient who had persistent pulmonary hypertension without improvement and right heart failure. Conclusion: Patients who have chronic pulmonary embolism are known to have a poor prognosis. However, we think that early surgical treatment along with making the proper diagnosis before the aggravation of right heart failure can help improve the quality of a patient's life.

The Change of Vascular Reactivity in Rat Thoracic Aorta 3 Days after Acute Myocardial Infarction (흰쥐에서 급성심근경색 3일 후 흉부 대동맥 혈관 반응성의 변화)

  • Lee, Sub;Roh, Woon-Seok;Jang, Jae-Seok;Bae, Chi-Hoon;Park, Ki-Sung;Lee, Jong-Tae
    • Journal of Chest Surgery
    • /
    • v.42 no.5
    • /
    • pp.576-587
    • /
    • 2009
  • Background: The up-regulation of the nitric oxide (NO)-cGMP pathway might be involved in the change of vascular reactivity in rats 3 days after they suffer acute myocardial infarction. However, the underlying mechanism for this has not been clarified. Material and Method: Acute myocardial infarction (AMI) was induced by occluding the left anterior descending coronary artery (LAD) for 30 min (Group AMI), whereas the sham-operated control rats were treated similarly without LAD occlusion (Group SHAM), The concentration-response relationships for phenylephrine (PE), KCl, acetylcholine (Ach) and sodium nitroprusside (SNP) were determined in the endothelium intact E(+) and endothelium denuded E(-) thoracic aortic rings from the rats 3 days after AMI or a SHAM operation. The concentration-response relationships of PE in the E(+) rings from the AMI rats were compared with those relationships in the rings pretreated with nitric oxide synthase (NOS) inhibitor $N{\omega}$-nitro-L-arginine methyl ester (L-NAME) or the cyclooxygenase inhibitor indomethacin. The plasma nitrite/nitrate concentrations were checked via a Griess reaction. The cyclic GMP content in the thoracic aortic rings was measured by radioimmunoassay and the endothelial nitric oxide synthase (eNOS) mRNA expression was assessed by real time PCR. Result: The mean infarct size (%) in the rats with AMI was $21.3{\pm}0.62%$. The heart rate and the systolic and diastolic blood pressure were not significantly changed in the AMI rats. The sensitivity of the contractile response to PE and KCl was significantly decreased in both the E(+) and E(-) aortic rings of the AMI group (p<0.05). L-NAME completely reversed these contractile responses whereas indomethacin did not (p<0.05). Moreover, the sensitivity of the relaxation response to Ach was also significantly decreased in the AMI group (p<0.05). The plasma nitrite and nitrate content (p<0.05), the basal cGMP content (p<0.05) and the eNOS mRNA expression (p=0.056) in the AMI rats were increased as compared with the SHAM group. Conclusion: Our findings indicate that the increased eNOS activity and the up-regulation of the NO-cGMP pathway can be attributed to the decreased contractile or relaxation response in the rat thoracic aorta 3 days after AMI.

An Experimental Study on Time Dependency of Strain for Saturated Clay (포화점토(飽和粘土)의 변형(變形)에 있어서 시간의존성(時間依存性)에 관한 실험적(實驗的) 연구(研究))

  • Park, Byong Kee;Lee, Jin Soo
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.4 no.3
    • /
    • pp.43-52
    • /
    • 1984
  • This paper is concerned with the strain characteristics of the time effect on the remoulded saturated day sampled from the downstream of the Yeongsan river, and the constitutive equation that can generally explain time-dependent behaviors of norma1ly consolidated clay. This paper examines whether or not the afore-said constitutive equation can be applied to the remoulded Mooan-clay. Throughout this study, the conclusions obtained are as follows. 1. Throughout the isotropic consolidation test for 7 days and the isotropic relaxation test, the existence of the static and dynamic yielding surfaces is confirmed respectively. 2. The characteristics of time effect of the deformation, namely, the existence of a unique stress-strain-time relation, is conformed from the experimental result on the Mooan-clay. 3. The prodictions of the stress path and the strain on the Cam-clay theory is not consistent with those observed during the experiments. 4. Constitutive equation(2-3-12) obtained by applying Cam-clay theory to Perzyna's elastic-viscoplasticity theory can explain the behavior of pore water pressure during isotropic stress relaxation, concerned with time dependency under undrained condition. The equation can also explain the results of the undrained triaxial compression test for the clay with different strain rate under the same or different consolidation history. 5. This constitutive equation has eight material parameters which can be determined from triaxial compression tests.

  • PDF

Carbon nanotube field emission display

  • Chil, Won-Bong;Kim, Jong-Min
    • Electrical & Electronic Materials
    • /
    • v.12 no.7
    • /
    • pp.7-11
    • /
    • 1999
  • Fully sealed field emission display in size of 4.5 inch has been fabricated using single-wall carbon nanotubes-organic vehicle com-posite. The fabricated display were fully scalable at low temperature below 415$^{\circ}C$ and CNTs were vertically aligned using paste squeeze and surface rubbing techniques. The turn-on fields of 1V/${\mu}{\textrm}{m}$ and field emis-sion current of 1.5mA at 3V/${\mu}{\textrm}{m}$ (J=90${\mu}{\textrm}{m}$/$\textrm{cm}^2$)were observed. Brightness of 1800cd/$m^2$ at 3.7V/${\mu}{\textrm}{m}$ was observed on the entire area of 4.5-inch panel from the green phosphor-ITO glass. The fluctuation of the current was found to be about 7% over a 4.5-inch cath-ode area. This reliable result enables us to produce large area full-color flat panel dis-play in the near future. Carbon nanotubes (CNTs) have attracted much attention because of their unique elec-trical properties and their potential applica-tions [1, 2]. Large aspect ratio of CNTs together with high chemical stability. ther-mal conductivity, and high mechanical strength are advantageous for applications to the field emitter [3]. Several results have been reported on the field emissions from multi-walled nanotubes (MWNTs) and single-walled nanotubes (SWNTs) grown from arc discharge [4, 5]. De Heer et al. have reported the field emission from nan-otubes aligned by the suspension-filtering method. This approach is too difficult to be fully adopted in integration process. Recently, there have been efforts to make applications to field emission devices using nanotubes. Saito et al. demonstrated a car-bon nanotube-based lamp, which was oper-ated at high voltage (10KV) [8]. Aproto-type diode structure was tested by the size of 100mm $\times$ 10mm in vacuum chamber [9]. the difficulties arise from the arrangement of vertically aligned nanotubes after the growth. Recently vertically aligned carbon nanotubes have been synthesized using plasma-enhanced chemical vapor deposition(CVD) [6, 7]. Yet, control of a large area synthesis is still not easily accessible with such approaches. Here we report integra-tion processes of fully sealed 4.5-inch CNT-field emission displays (FEDs). Low turn-on voltage with high brightness, and stabili-ty clearly demonstrate the potential applica-bility of carbon nanotubes to full color dis-plays in near future. For flat panel display in a large area, car-bon nanotubes-based field emitters were fabricated by using nanotubes-organic vehi-cles. The purified SWNTs, which were syn-thesized by dc arc discharge, were dispersed in iso propyl alcohol, and then mixed with on organic binder. The paste of well-dis-persed carbon nanotubes was squeezed onto the metal-patterned sodalime glass throuhg the metal mesh of 20${\mu}{\textrm}{m}$ in size and subse-quently heat-treated in order to remove the organic binder. The insulating spacers in thickness of 200${\mu}{\textrm}{m}$ are inserted between the lower and upper glasses. The Y\ulcornerO\ulcornerS:Eu, ZnS:Cu, Al, and ZnS:Ag, Cl, phosphors are electrically deposited on the upper glass for red, green, and blue colors, respectively. The typical sizes of each phosphor are 2~3 micron. The assembled structure was sealed in an atmosphere of highly purified Ar gas by means of a glass frit. The display plate was evacuated down to the pressure level of 1$\times$10\ulcorner Torr. Three non-evaporable getters of Ti-Zr-V-Fe were activated during the final heat-exhausting procedure. Finally, the active area of 4.5-inch panel with fully sealed carbon nanotubes was pro-duced. Emission currents were character-ized by the DC-mode and pulse-modulating mode at the voltage up to 800 volts. The brightness of field emission was measured by the Luminance calorimeter (BM-7, Topcon).

  • PDF