Study on Development of Inducing Airflow Duct System for Kitchen Hood Using Ejector Method (이젝터 기술을 활용한 주방후드용 기류유인 덕트 시스템의 개발에 관한 연구)

  • Son, Yu-Ra;Hong, Seong-Gyu;Yang, Jeong-Hoon
    • Journal of the Korean Solar Energy Society
    • /
    • v.39 no.6
    • /
    • pp.27-40
    • /
    • 2019
  • Kitchen hoods are limited in discharging all contaminants produced during cooking. Contaminants that have not been discharged can rise to the upper part of the kitchen and become stacked. To solve this problem, there is a way to increase the air volume of the kitchen hood, but there are limits, so a new system is required. This study proposes the Duct System (IADK : Inducing Airflow Duct system for Kitchen hood )through 3D printers and experiments. To do this, the pressure is measured to verify the three levels of air volume provided by the kitchen hood. To check the degree of loss of flow in the existing kitchen hood system, install flexible ducts alone to measure the pressure. Change the internal diameter and type of connection of the IADK and measure the pressure. The air pressure, static pressure difference, and loss factor are calculated and analyzed using the pressure measured through the experiment.

The inertial coefficient for fluctuating flow through a dominant opening in a building

  • Xu, Haiwei;Yu, Shice;Lou, Wenjuan
    • Wind and Structures
    • /
    • v.18 no.1
    • /
    • pp.57-67
    • /
    • 2014
  • For a building with a dominant windward wall opening, the wind-induced internal pressure response can be described by a second-order non-linear differential equation. However, there are two ill-defined parameters in the governing equation: the inertial coefficient $C_I$ and the loss coefficient $C_L$. Lack of knowledge of these two parameters restricts the practical use of the governing equation. This study was primarily focused on finding an accurate reference value for $C_I$, and the paper presents a systematic investigation of the factors influencing the inertial coefficient for a wind-tunnel model building including: opening configuration and location, wind speed and direction, approaching flow turbulence, the model material, and the installation method. A numerical model was used to simulate the volume deformation under internal pressure, and to predict the bulk modulus of an experimental model. In considering the structural flexibility, an alternative approach was proposed to ensure accurate internal volume distortions, so that similarity of internal pressure responses between model-scale and full-scale building was maintained. The research showed 0.8 to be a reasonable standard value for the inertial coefficient.

Effects of Casing Shape on the Performance of a Small-sized Centrifugal Compressor

  • Kim, D.W.;Kim, H.S.;Kim, Youn-J.
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • v.11 no.3
    • /
    • pp.132-139
    • /
    • 2003
  • The effects of casing shapes on the performance and the interaction between an impeller and a casing in a small-sized centrifugal compressor are investigated. Especially, numerical analyses are conducted for the centrifugal compressor with both a circular casing and a volute one. The optimum design for each element (i.e., impeller, diffuser and casing) is important to develop an efficient and compact compressor using alternative refrigerant as working fluids. Typical rotating speed of the compressor is in the range of 40,000∼45,000 rpm. The impeller has backswept blades due to tip clearance and a vane diffuser has wedge type. In order to predict the flow pattern inside an entire impeller, vaneless diffuser and casing, calculations with multiple frames of reference method between the rotating and stationery parts of the domain are carried out. For computations of compressible turbulent flow fields, the continuity and time-averaged Navier-Stokes equations are employed. To evaluate the performance of two types of casings, the static pressure recovery and loss coefficients are obtained for various flow rates. Also, static pressure distributions around casings are studied for different casing shapes, which are very important to predict the distribution of radial load. The static pressure around the casing and pressure difference between the inlet and outlet of the compressor are measured for the circular casing.

Pressure Loss in the Discharge Flow Path from a Diffuser to a wall (디퓨저에서 벽면으로의 방출유로에서의 압력손실)

  • Lee, J.;Kim, Y.I.;Kim, S.H.;Lee, D.J.
    • Proceedings of the KSME Conference
    • /
    • 2001.11b
    • /
    • pp.517-522
    • /
    • 2001
  • The exit edges of a diffuser are smoothly rounded, and a wall is located perpendicularly to a diffuser exit. The fluid is discharged towards the radial direction of a diffuser after impinging against a wall from a diffuser. In this flow path, pressure loss coefficients have been calculated by the variables of Reynolds number at a diffuser inlet, distance between a diffuser exit and a wall, and turbulence models. As a result, it was calculated that $h/D_0$ ratio between $0.35\sim0.4$ has the minimum pressure loss coefficient regardless of Reynolds number and turbulence models. It was also found that in case of the flow with relatively high Reynolds number at a diffuser inlet, the pressure loss coefficients by RNG $k-\varepsilon$ model have a tendency to be near to those by standard $k-\varepsilon$ model at small ratio of $h/D_0$, but to those by RSM at large ratio.

  • PDF

A study on the flow characteristics in a plug valve with various port shapes (플러그 밸브의 포트형상 변화에 따른 유동특성 연구)

  • Choi, G.-W.;Park, G.-J.;Kim, Youn J.
    • 유체기계공업학회:학술대회논문집
    • /
    • 2000.12a
    • /
    • pp.259-264
    • /
    • 2000
  • The functions of the plug valve are the control of flow rate as well closing and opening pipe lines. Analyses on the flow characteristics in plug valve port are required to improve the performance and safety at severe operating conditions such as high-pressure and high-temperature. In this study, numerical analyses are carried out with varying the opening rate (fraction of the full open to close) of the valve and the shapes of valve Uk: straight, convex, concave and mixed shapes. The parameters influencing the flow characteristics in the valve are the discharge coefficient( $C_v$) and the resistance coefficient( K). Therefore, the distributions of static pressure, velocity vector and stream lines are investigated, and $C_v$ and K are calculated in each opening rate and shape. In case of full open, the static pressure passed through the valve port has almost been recovered. However, in case of other opening rates, the pressure does not permanently regained due to pressure drop leading to loss. This phenomenon in each shape of the valve shows the different behaviors. Calculation results show that the mixed shape has the best flow attribute.

  • PDF

Enhancement of the Performance a Centrifugal Compressor in an Automobile Turbocharger by Modifying the Circumferential Inlet Height of Volute (원주방향 볼류트 입구 높이를 수정한 자동차용 터보차저 원심압축기의 성능 향상)

  • Zhou, Tianjun;Lee, Geun Sik
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.38 no.2
    • /
    • pp.115-120
    • /
    • 2014
  • To enhance the performance of an automobile turbocharger compressor, the circumferential inlet heights of the volute were modified and the flow field for the combined region of the diffuser and volute was numerically investigated using commercial software. Basically, a well-designed volute should have a high pressure recovery coefficient and a low loss coefficient for the total pressure. In this study, two circular volutes with the same cross sectional shape and tongue angle, but circumferentially different volute inlet heights, were selected. One volute had the middle inlet in the cross-section at the circumferential angle of $90^{\circ}$ but gradually lower inlet heights for the angles between $90^{\circ}$ to $360^{\circ}$ with respect to the cross sectional center of the volute, while maintaining the same height between the tangential line connecting the lowest positions of the cross section and the line connecting the volute inlets in the circumferential direction (case 1 volute). The other volute has an inlet height that is 2 mm lower than in case 1 volute such that the tongue section has a tangential inlet (case 2 volute). The results showed that the case 2 volute had a higher total pressure ratio because of its higher pressure recovery coefficient and higher isentropic efficiency, resulting from the lower loss coefficient along the circumferential position than the case 1 volute.

Reflection and Transmission Coefficients by a Circular Pile Breakwater (원형 파일 방파제에 의한 반사율과 투과율)

  • Cho, Il-Hyoung;Koh, Hyeok-Jun
    • Journal of Korean Society of Coastal and Ocean Engineers
    • /
    • v.19 no.1
    • /
    • pp.38-44
    • /
    • 2007
  • Using the mathematical model suggested by Bennet et al.(1992), the reflection and transmission coefficients by a circular pile breakwater has been investigated in the framework of potential theory. Flow separation due to sudden contraction and expansion is generated and is the main cause of significant energy loss. Therefore, evaluation of exact energy loss coefficient is critical to enhance the reliability of mathematical model. To obtain the energy loss coefficient, 2-dimensional turbulent flow is analyzed using the FLUENT commercial code. The energy loss coefficient can be obtained from the pressure difference between upstream and downstream. Energy loss coefficient is the function of porosity and the relation equation between them is suggested throughout the curve fitting processing. To validated the suggested relation, comparison between the analytical results and the experimental results is made for four different porosities with good agreement.

Energy Loss and Flow Rate at Junction Pipe (합류관에서의 손실과 유량)

  • Kim, M.K.;Kwon, O.B.
    • Journal of Power System Engineering
    • /
    • v.9 no.4
    • /
    • pp.39-44
    • /
    • 2005
  • This paper presents the study of flows at T-junction pipe with orifices. Experiments were carried out for several flow rates, orifice sizes, and pressure differences. Numerical simulations were also done to get more data for the wide range of flow rates. Experimental results and numerical ones are in a good agreement. Due to the effect of T-junction part, the flow rates at the lateral pipe are greater than those at straight pipe for the same pressure differences. When orifices were added, the effects of T-junction part on the ratio of flow rates and the ratio of loss coefficients reduced.

  • PDF

CFD ANALYSIS OF FLOW CHANNEL BLOCKAGE IN DUAL-COOLED FUEL FOR PRESSURIZED WATER REACTOR (가압경수로 이중냉각핵연료의 내측수로 막힘에 대한 전산유체역학 해석)

  • In, W.K.;Shin, C.B.;Park, J.Y.;Oh, D.S.;Lee, C.Y.;Chun, T.H.
    • 한국전산유체공학회:학술대회논문집
    • /
    • 2011.05a
    • /
    • pp.269-274
    • /
    • 2011
  • A CFD analysis was performed to examine the inner channel blockage of dual-cooled fuel which has being developed for the power uprate of a pressurized water reactor (PWR). The dual-cooled fuel consists of an annular fuel pellet($UO_2$) and dual claddings as well as internal and external cooling channels. The dual-cooled annular fuel is different from a conventional solid 려el by employing an internal cooling channel for each fuel pellet as well as an external cooling channel. One of the key issues is the hypothetical event of inner channel blockage because the inner channel is an isolated flow channel without the coolant mixing between the neighboring flow channels. The inner channel blockage could cause the Departure from Nucleate Boiling (DNB) in the inner channel that eventually causes a fuel failure. This paper presents the CFD simulation of the flow through the side holes of the bottom end plug for the complete entrance blockage of the inner channel. Since the amount of coolant supply to the inner channel depends on largely the pressure loss at the side hole, the pressure loss coefficient of the side hole was estimated by the CFD analysis. The CFD prediction of the loss coefficient showed a reasonable agreement with an experimental data for the complete blockage of both the inner channel entrance and the outer channel. The CFD predictions also showed the decrease of the loss coefficient as the outer channel blockage increases.

  • PDF

Flow Characteristics of T-junction Pipe (T-합류관의 유동특성)

  • Kim, M.K.;Bae, D.S.;Kwon, O.B.;Yang, J.K.
    • Proceedings of the Korean Society of Marine Engineers Conference
    • /
    • 2005.06a
    • /
    • pp.528-533
    • /
    • 2005
  • This paper presents the study of flows at T-junction pipe with orifices. Experiments were carried out for several flow rates, orifice sizes, and pressure differences. Numerical simulations were also done to get more data for the wide range of flow rates. Experimental results and numerical ones are in a good agreement. Due to the effect of T-junction part, the flow rates at the lateral pipe are greater than those at straight pipe for the same pressure differences. When orifices were added, the effects of T-junction part on the ratio of flow rates and the ratio of loss coefficients reduced.

  • PDF