• Title/Summary/Keyword: Pressure loss

Search Result 2,157, Processing Time 0.028 seconds

A Study on Pressure Loss and Turbulent Charactristics in a Conical Diffuser with a Swirl Flow (유입 선회류에 대한 디퓨져 손실 및 난류특성에 관한 연구)

  • Jeong, Hyo-Min;Koh, Dae-Kwon;Yang, Jung-Kyu
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.28 no.2
    • /
    • pp.157-163
    • /
    • 1992
  • In this paper, the relationship between static pressure recovery and turbulent energy was presented in case of swirling flows into a conical diffuser. The distributions of turbulent energy in a diffuser sectional area were measured by a hot wire anemometer. The following conclusion can be drawn from the experiment. Diffuser loss is constituted by a dynamic pressure loss and total pressure loss. The static pressure recovery depends strongly on the total pressure loss. The static pressure recovery depends strongly on the total pressure loss, and the turbulent energy varies inversely as the static pressure recovery coefficient.

  • PDF

Analysis of hydraulic system for seawater desalination plant through piping analysis program (배관 해석 프로그램을 통한 해수담수화 플랜트 수압 시스템 분석)

  • Choi, Jihyeok;Choi, Yongjun;Yang, Heungsik;Lee, Sangho;Choi, June-Seok
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.34 no.3
    • /
    • pp.221-230
    • /
    • 2020
  • In actual seawater desalination plant, the pressure loss due to frictional force of pipe is about 3~5 bar. Also, the pressure loss at pipe connection about 1~3 bar. Therefore, the total pressure loss in the pipe is expected to be about 4~8 bar, which translates into 0.111 to 0.222 kWh/㎥ of energy when converted into the Specific Energy Consumption(SEC). Reducing energy consumption is the most important factor in ensuring the economics of seawater desalination processes, but pressure loss in piping is often not considered in plant design. It is difficult to prevent pressure loss due to friction inside the pipe, but pressure loss at the pipe connection can be reduced by proper pipe design. In this study, seawater desalination plant piping analysis was performed using a commercial network program. The pressure loss and SEC for each case were calculated and compared by seawater desalination plant size.

Development of prediction model for pressure loss and cut-size of cyclone separator depend on wall curvature (사이클론 집진기의 벽면구배에 따른 압력손실과 컷-사이즈 변화 예측 모델 개발)

  • Heo, Kwang-Su;Seol, Seoung-Yun
    • Proceedings of the KSME Conference
    • /
    • 2008.11b
    • /
    • pp.2676-2681
    • /
    • 2008
  • In previous studies, Convex cyclone are proposed to reduce pressure loss which are design cyclone wall with a single continuous curve. Studies about a prediction model for pressure loss and cut-size has focused on conventional cylinder-on-con cyclone. Therefore, the models do not perform well for uncommon design. In this study, a predict model for pressure loss and cut-size depend on cyclone wall curvature are developed. The tangential velocity below vortex-finder is obtained with consideration about friction area and momentum loss on the cyclone wall, and with this the variation of vortex-core and core velocity is obtained. Pressure loss is predicted using a Rankine vortex hypothesis. The prediction results are well agreed with experiments and CFD results.

  • PDF

Numerical Study on Reverse Flow Charcteristics in an Axial Compressor Cascade (축류압축기 익렬에서의 역류 유동 특성에 대한 수치적 연구)

  • Sohn, Chang-Hyun;Longley, John Peter
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.24 no.5
    • /
    • pp.615-622
    • /
    • 2000
  • Numerical simulation is performed with Denton's code to get pressure loss coefficients in wide range of reverse flow incidence(from -90 degree to +85 degree) for an axial compressor cascade. As a results, it is found that the pressure loss coefficient is increased with incidence and there exist critical incidence which corresponds to the maximum pressure loss coefficient. Pressure loss coefficient with bigger incidence than its critical value is decreased. The effect of increasing incidence in a cascade extremely reduce the mass flow rate by the large flow separation region. Consequently this effect reduce the portion of dynamic pressure in the total pressure loss and beyond the critical incidence the pressure loss coefficient decrease.

Effects of the Inlet Boundary Layer Thickness on the Flow in an Axial Compressor(II) - Loss Mechanism - (입구 경계층 두께가 축류 압축기 내부 유동에 미치는 영향 (II) - 손실구조 -)

  • Choi, Min-Suk;Park, Jun-Young;Baek, Je-Hyun
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.29 no.8 s.239
    • /
    • pp.956-962
    • /
    • 2005
  • A three-dimensional computation was conducted to make a study about effects of the inlet boundary layer thickness on the total pressure loss in a low-speed axial compressor operating at the design condition ($\phi=85\%$) and near stall condition($\phi=65\%$). Differences of the tip leakage flow and hub corner-stall induced by the inlet boundary layer thickness enable the loss distribution of total pressure along the span to be altered. At design condition, total pressure losses for two different inlet boundary layers are almost alike in the core flow region but the larger loss is generated at both hub and tip when the inlet boundary layer is thin. At the near stall condition, however, total pressure loss fer the thick inlet boundary layer is found to be greater than that for the thin inlet boundary layer on most of the span except the region near hub and casing. Total pressure loss is scrutinized through three major loss categories in a subsonic axial compressor such as profile loss, tip leakage loss and endwall loss using Denton's loss model, and effects of the inlet boundary layer thickness on the loss structure are analyzed in detail.

A study on the pressure loss coefficient of non-Newtonian fluids in the stenotic tubes (비뉴턴 유체의 협착관내 압력손실계수에 관한 연구)

  • Seo, Sang-Ho;Yu, Sang-Sin;Jang, Nam-Il
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.20 no.5
    • /
    • pp.1603-1612
    • /
    • 1996
  • The pressure loss coefficient of Newtonian and non-Newtonian fluids such as water, aqueous solutions of Carbopol-934 and Separan AP-273 and blood in the stenotic tubes are determined experimentally and numerically. The numerical analyses for flows of non-Newtonian fluids in the stenotic tubes are conducted by the finite element method. The effect of the contraction ratio and the ratio of length to diameter on the pressure drop are investigated by the experiments and numerical analysis. The pressure loss coefficients are significantly dependent upon the Reynolds number in the laminar flow regime. As Reynolds number increases, the pressure loss coefficients of both Newtonian and non-Newtonian fluids decrease in the laminar flow regime. As the ratio of length to diameter increases the maximum pressure loss coefficient increases in the laminar flow regime for both Newtonian and non-Newtonian fluids. Newtonian fuid shows the highest values of pressure loss coefficient and blood the next, followed by Carbopol solution and Separan solution in order. Experimental results are used to verify the numerical analyses for flows of Newtonian and non-Newtonian fluids. Numerical results for the maximum pressure loss coefficient in the stenotic tubes are in fairly good agreement with the experimental results. The relative differences between the numerical and experimental results of the pressure loss coefficients in the laminar flow regime range from 0.5% to 14.8%.

Study on the Pressure Loss of Hoses in a Fire Hose Reel Hydrant (호스릴옥내소화전 호스에 대한 압력손실에 관한 연구)

  • Whang, Young-Kwon;Lee, Seung-Chul
    • Fire Science and Engineering
    • /
    • v.33 no.2
    • /
    • pp.63-67
    • /
    • 2019
  • In this study, the pressure loss of a fire hose reel hydrant was examined and the effects of each factor on the pressure loss were analyzed. First, in the pressure loss experiment according to the length of the reel hose, the pressure loss increased with increasing length of the reel hose; it was approximately 38.86% based on a 25 m hose. Second, the pressure loss of the reel hose per unit length was estimated to be $.13{\sim}.15kgf/cm^2$. Third, in the pressure loss experiment according to the change in the flow rate, the result was similar to the relation, flow rate - pressure loss (${\Delta}P{\sim}Q^2$), in the piping flow. These results provide basic data on the evaluation of fire pump pressure and the performance-based fire-protecting design of fire hose reel hydrants used in buildings.

A Computational Study on the Pressure Loss of Intake System for the Combat Vehicle (전투차량 흡기시스템의 압력손실에 관한 수치적 연구)

  • Moon, Seong-Mok;An, Su-Hong;Lee, Kyoung-Hoon;Woo, Kwan-Je
    • The KSFM Journal of Fluid Machinery
    • /
    • v.15 no.3
    • /
    • pp.25-31
    • /
    • 2012
  • A computational study on the improvement of the pressure loss of intake system, which is located at engine manifold of the combat vehicle, has been conducted using a finite-volume-based, Reynolds-Averaged Navier-Stokes (RANS) solver. The computational result of the pressure loss through the air cleaner is in good agreement with equivalent experimental data. A parametric study was done for improving of the pressure loss of intake system over the baseline case. The effects of five primary parameters such as the height of inlet, the width of interconnection pipe, the shape of drain chamber and the diameter of filter housing were considered in this study. Consequently, this computational investigation can contribute to finding an optimal guideline for the idea of improvement in the pressure loss of intake system.

Numerical Evaluation of Flow and Performance of Turbo Pump Inducers

  • Shim, Chang-Yeul;Kang, Shin-Hyoung
    • Journal of Mechanical Science and Technology
    • /
    • v.18 no.3
    • /
    • pp.481-490
    • /
    • 2004
  • Steady state flow calculations are executed for turbo-pump inducers of modern design to validate the performance of Tascflow code. Hydrodynamic performance of inducers is evaluated and structure of the passage flow and leading edge recirculation are also investigated. Calculated results show good coincidence with experimental data of static pressure performance and velocity profiles over the leading edge. Upstream recirculation, tip leakage and vortex flow at the blade tip and near leading edge are main sources of pressure loss. Amount of pressure loss from the upstream to the leading edge corresponds to that of whole pressure loss through the blade passage. The viscous loss is considerably large due to the strong secondary flow. There appears more stronger leading edge recirculation for the backswept inducer, and this increases the pressure loss. However, blade loading near the leading edge is considerably reduced and cavitation inception delayed.

Total Pressure Loss in a Supersonic Nozzle Flow with Condensation (凝縮을 隨伴하는 超音速 노즐흐름의 全壓損失)

  • 강창수;권순범
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.12 no.3
    • /
    • pp.582-589
    • /
    • 1988
  • A rapid expansion of moist air or steam in a supersonic nozzle gives rise to condensation, and the total pressure of the flow is decreased due to this irreversibility of condensation phenomenon. In the present paper, the loss in total pressure during the condensation process has been studied, by numerical analysis and pressure measurement, in the case of moist air expanding in a supersonic nozzle. The effects of the degree of supersaturation at the stagnation condition and expansion rate of the nozzle on the total pressure loss have been studied. The length of the region where the total pressure decreases during the condensation process is longer than that of the nonequilibrium condensation region, and of difference between the length of these two increases with the increase of the degree of supersaturation at the stagnation condition. Furthermore, the larger the expansion rate of the nozzle and the higher the temperature and the degree of supersaturation at the reservoir are, the larger the total pressure loss of the flow becomes. And, it is turned out that the total pressure loss be about 2 to 8 percent in the present study.