• Title/Summary/Keyword: Pressure filtration

Search Result 354, Processing Time 0.022 seconds

Pressure Drop Predictions Using Multiple Regression Model in Pulse Jet Type Bag Filter Without Venturi (다중회귀모형을 이용한 벤츄리가 없는 충격기류식 여과집진장치 압력손실 예측)

  • Suh, Jeong-Min;Park, Jeong-Ho;Cho, Jae-Hwan;Jin, Kyung-Ho;Jung, Moon-Sub;Yi, Pyong-In;Hong, Sung-Chul;Sivakumar, S.;Choi, Kum-Chan
    • Journal of Environmental Science International
    • /
    • v.23 no.12
    • /
    • pp.2045-2056
    • /
    • 2014
  • In this study, pressure drop was measured in the pulse jet bag filter without venturi on which 16 numbers of filter bags (Ø$140{\times}850{\ell}$) are installed according to operation condition(filtration velocity, inlet dust concentration, pulse pressure, and pulse interval) using coke dust from steel mill. The obtained 180 pressure drop test data were used to predict pressure drop with multiple regression model so that pressure drop data can be used for effective operation condition and as basic data for economical design. The prediction results showed that when filtration velocity was increased by 1%, pressure drop was increased by 2.2% which indicated that filtration velocity among operation condition was attributed on the pressure drop the most. Pressure was dropped by 1.53% when pulse pressure was increased by 1% which also confirmed that pulse pressure was the major factor affecting on the pressure drop next to filtration velocity. Meanwhile, pressure drops were found increased by 0.3% and 0.37%, respectively when inlet dust concentration and pulse interval were increased by 1% implying that the effects of inlet dust concentration and pulse interval were less as compared with those changes of filtration velocity and pulse pressure. Therefore, the larger effect on the pressure drop the pulse jet bag filter was found in the order of filtration velocity($V_f$), pulse pressure($P_p$), inlet dust concentration($C_i$), pulse interval($P_i$). Also, the prediction result of filtration velocity, inlet dust concentration, pulse pressure, and pulse interval which showed the largest effect on the pressure drop indicated that stable operation can be executed with filtration velocity less than 1.5 m/min and inlet dust concentration less than $4g/m^3$. However, it was regarded that pulse pressure and pulse interval need to be adjusted when inlet dust concentration is higher than $4g/m^3$. When filtration velocity and pulse pressure were examined, operation was possible regardless of changes in pulse pressure if filtration velocity was at 1.5 m/min. If filtration velocity was increased to 2 m/min. operation would be possible only when pulse pressure was set at higher than $5.8kgf/cm^2$. Also, the prediction result of pressure drop with filtration velocity and pulse interval showed that operation with pulse interval less than 50 sec. should be carried out under filtration velocity at 1.5 m/min. While, pulse interval should be set at lower than 11 sec. if filtration velocity was set at 2 m/min. Under the conditions of filtration velocity lower than 1 m/min and high pulse pressure higher than $7kgf/cm^2$, though pressure drop would be less, in this case, economic feasibility would be low due to increased in installation and operation cost since scale of dust collection equipment becomes larger and life of filtration bag becomes shortened due to high pulse pressure.

Pressure Filtration of Zr(Y,Ce)$O_2$ TZP/Mullite Suspensions for the Preparations of Functionally Gradient Materials with Multi-layer (다층 경사기능재료의 제조를 위한 Zr(Y,Ce)$O_2$ TZP/Mullite 현탁액의 가압여과)

  • 이상진;박상희;박홍채;전병세
    • Journal of the Korean Ceramic Society
    • /
    • v.37 no.7
    • /
    • pp.693-699
    • /
    • 2000
  • Casting behavior of Zr(Y,Ce)O2 TZP/Mullite suspension during pressure filtration was investigated to prepare multi-layered Functionally Gradient Materials(FGM). The dispersion stabilities of each layer suspension were investigated by examination of zeta potential and viscosity. The each suspensions with 20 vol.% solid loading and 100 첸 of viscosity was prepared after fix of the dispersing agent (Sodium hexa-meta phosphate) and the binder (Hydroxyethyl cellulose), and then the cakes were formed at the 2.5 MPa~10.0MPa pressure range. The cake thickness of all suspensions was increased with the square root of time at the constant pressure, and the relations between filtration pressure(P)a nd dehydration rate (Q=dh/dt) showed that the flows of filtrates in the consolidated layers were laminar. The permeabilities were nearly constant during filtration, and kozeny constants(Kc) of the suspensions were 4.8~6.7. These valumes were seen as close to 5, which might be homogeneous particle packing during filtration. On the basis of those data, the multi layered compaction with 9 mm thickness and 52.5% green density was prepared by continuous pressure filtration.

  • PDF

Filtration-induced pressure evolution in permeation grouting

  • Zhou, Zilong;Zang, Haizhi;Wang, Shanyong;Cai, Xin;Du, Xueming
    • Structural Engineering and Mechanics
    • /
    • v.75 no.5
    • /
    • pp.571-583
    • /
    • 2020
  • Permeation grouting is of great significance for consolidating geo-materials without disturbing the original geo-structure. To dip into the filtration-induced pressure increment that dominates the grout penetration in permeation grouting, nonlinear filtration coefficients embedded in a convection-filtration model were proposed, in which the volume of cement particles in grout and the deposited particles of skeleton were considered. An experiment was designed to determine the filtration coefficients and verify the model. The filtration coefficients deduced from experimental data were used in simulation, and the modelling results matched well with the experimental ones. The pressure drop revealed in experiments and captured in modelling demonstrated that the surge of inflow pressure lagged behind the stoppage of flow channels. In addition, both the consideration of the particles loss in liquid grout and the number of filtrated particles on pore walls presented an ideal trend in filtration rate, in which the filtration rate first rose rapidly and then reached to a steady plateau. Finally, this observed pressure drop was extended to the grouting design which alters the water to cement (W/C) ratio so as to alleviate the filtration effect. This study offers a novel insight into the filtration behaviour and has a practical meaning to extend penetration distance.

The Improvement of Cake Filtration Rate using CO2 Gas Saturation (이산화탄소(CO2) 가스에 의한 케이크 여과속도의 향상)

  • Yim, Sung Sam;Song, Yun Min
    • Korean Chemical Engineering Research
    • /
    • v.44 no.5
    • /
    • pp.468-475
    • /
    • 2006
  • For the filtration of super compactible cake, the high filtration pressure can not improve filtration rate. As the high pressure, in this case, decreases the cake porosity adjacent to filter medium and thus forms 'dense skin' which decreases the rate of liquid flow in a great extent. Actually, there was no method to improve filtration rate for the filtration with super compactible cake. We propose the saturation of $CO_2$ gas into the suspension before the filtration operation for improving the filtration rate. The dissolved $CO_2$ gas transforms itself into gas phase in the dense skin through which the pressure changes dramatically. The gas secures its space inside the dense skin, and finally forms the flow passages which improve the filtration rate.

A Study on the Factors Affecting Cake Filtration (케이크 여과에 영향을 미치는 요인에 관한 연구)

  • 장재선
    • Journal of Environmental Health Sciences
    • /
    • v.21 no.2
    • /
    • pp.7-11
    • /
    • 1995
  • This study was carried out to investigate the change of average specific resistance according to filtration pressure, suspension concentration and filters for study phenomena occurring in cake filtration. As the results of this study, the following conclusions were obtained. It was estimated that the average specific resistance of filtration Was decreased in proportion to decreased of filtration pressure. But in very pressure, average specific resistance was increased. The average specific resistance value on filter medium by various pressure was showed as same trends under constant suspension concentration. This phenomenon was though that a carrain amount of fine particles in the cake was found to migrate throught the cake in the case of very thin at very low pressure. In relation to the change of suspension concentration, average specific resistance value become low according to decreased in supension concentration.

  • PDF

The Effect of Vacuum Pressure in Membrane Filtration Systems for the Efficient Detection of Bacteria from Natural Mineral Water

  • LEE, KI-YONG;CHANG-JAE WOO;TAE-RYEON HEO
    • Journal of Microbiology and Biotechnology
    • /
    • v.8 no.2
    • /
    • pp.124-128
    • /
    • 1998
  • The procedures currently used for determining microbiological quality of natural mineral water recommend filtration through membrane filters. In this study, we evaluated the effect of vacuum pressure for the accurate detection of bacteria from water samples seeded with Escherichia coli. We observed that the number of E. coli detected increased with increasing vacuum pressure. In order to examine the retention rate of bacteria in the holes of the membranes under the different pressures, the membrane filters were removed after filtration, washed with sterile water by vortexing, and placed on m-Endo agar plates. With all the filters tested, the number of E. coli retained within the filters at negative 600 mmHg was approximately 10 to $20\%$ higher than that obtained with 100 mmHg. These results demonstrate that the vacuum pressure exerted during the filtration procedure may affect the fixation of bacteria into some portions of openings in the membrane filter.

  • PDF

Rigorous Modeling of Single Channel DPF Filtration and Sensitivity Analysis of Important Model Parameters (단일 채널 DPF의 PM 포집 모델링 및 모델 파라미터의 민감도 해석)

  • Jung, Seung-Chai;Park, Jong-Sun;Yoon, Woong-Sup
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.14 no.6
    • /
    • pp.127-136
    • /
    • 2006
  • Prediction of diesel particulate filtration is typically made by virtue of modeling of particulate matter(PM) collection. The model is closed with filtration parameters reflecting all small scale phenomena associated with PM trapping, and these parameters are to be traced back by inversely analyzing large-scale empirical data-the pressure drop histories. Included are soot cake permeability, soot cake density, soot density in the porous filter wall, and percolation constant. In the present study, a series of single channel DPF experiment is conducted, pressure histories are inversely analyzed, and the essential filtration parameters are deducted by DPF filtration model formulated with non-linear description of soot cake regression. Sensitivity analyses of model parameters are also made. Results showed that filtration transients are significantly altered by the extent of percolation constant, and the soot density in the porous filter wall is controlling the filtration qualities in deep-bed filtration regime. In addition, effect of soot particle size on filtration quality is distinct in a period of soot cake regime.

Examination of Dust Trapping Mechanism in a Metal Fiber Filter-bed (금속 섬유 필터층을 이용한 미세 분진 집진 성능 관찰)

  • 이경미;조영민
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.20 no.3
    • /
    • pp.361-369
    • /
    • 2004
  • A metal fiber bed has seldom been applied to the practical filtration process despite its excellent mechanical and chemical stability. The filter-bed used in this work was highly porous with open structure, of which apparent porosity was 80 ∼ 90%. Although pressure loss across the filter-bed was very low, separation efficiency was found to be quite high. This paper focuses on the basic filtration mechanisms of a metal filter-bed and a thin ceramic filter from fly ash for reference. The experimental parameters were face velocity, dust loading and porosity of filter-bed. Pressure drop increased with increasing face velocity and dust feeding load for both filters. It also showed that dust particles deposited in the deep flow path, finally resulting in clogging the pore channels. It thereby indicates that the dominating mechanism of the metal filter-bed would be depth filtration. Meanwhile, the thin fly ash composite filters trapped the aerated dust mainly on the surface of the filter medium, so that the instantaneously formed dust layer might cause a steep increase of pressure drop across the filtration system.

An Experimental Study on Transient Behavior of Granular Aerosol Filtration : Effect of Particle Deposition on Pressure Drop (입자층 에어로졸여과의 과도거동에 관한 실험연구 : 압력강하에 대한 입자 퇴적의 영향)

  • 정용원
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.13 no.3
    • /
    • pp.193-205
    • /
    • 1997
  • Experiments on granular filtration of polydispersed aerosols were conducted to determine the changes in pressure drop necessary to maintain a given gas flow rate as filter becomes clogged with deposited particles. Among the various variables which affect the increase in the pressure drop during the filtration, the most important one was found to be the size of the deposited aerosol particles. It was shown that for a given extent of the total deposition, the extent of increase in pressure drop increases with the decrease of the deposited aerosol size. For the general case where the deposited particles have different sizes, a procedure was proposed for correlating and predicting experimental results on pressure drop. This procedure was found applicable to bidispersed aerosols and polydispersed aerosols.

  • PDF

Evaluation of Filtration Performance Efficiency of Commercial Cloth Masks (시판되고 있는 유사마스크 제품의 여과효율성능 비교평가)

  • Jang, Ji Young;Kim, Seung Won
    • Journal of Environmental Health Sciences
    • /
    • v.41 no.3
    • /
    • pp.203-215
    • /
    • 2015
  • Objectives: This study was designed to evaluate the filtration efficiencies and pressure drops of five commercial cloth masks (4 plate type, 1 cup type) in comparison to the performance of a class 1 disposable respirator (reference respirator). A further objective was to evaluate the effects of the number of layers and wash treatment independently on filtration efficiencies and pressure drops. Methods: Polydisperse NaCl aerosols were generated in an aerosol chamber and their concentrations were measured by an optical particle counter (OPC) in the size range of $0.3{\sim}10{\mu}m$ (five channels). Results: The filtration efficiencies of the five cloth masks and the reference respirator were D: 9.5%, C: 18.5%, E: 23.6%, A: 28.5%, B: 29.7% and R: 91.1%, respectively, and the pressure drops through them were C, D: 0.8 Pa, E: 1.7 Pa, B: 6.4 Pa, A: 42.7 Pa and R: 19.3 Pa, respectively. The filtration efficiencies of the cloth masks and reference respirator were below the class 1 respirator criterion (${\geq}94.0%$) of the Ministry of Employment and Labor (MOEL) and Ministry of Food and Drug Safety (MFDS). The pressure drops satisfied the class 1 respirator criterion (${\leq}70Pa$) of MOEL and MFDS. When the cloth masks were folded into two and four layers, the filtration efficiencies of cloth masks A, B, C, D (plate type) increased 1.7-4.6 times, and 2.3-6.8 times, respectively, compared to the efficiencies of the same products in a single layer. Pressure drops increased as the number of layers was increased. The filtration efficiency of cloth mask E with a liner was 1.3 times higher than that of the same mask without a liner, and the pressure drop was lower in the no-liner configuration. After a single washing, the filtration efficiencies of all the cloth mask products decreased 1.04-4.0 times compared to those of the same products intact. For the cloth masks C and E, their filtration efficiencies were significantly decreased after washing (p<0.05). The pressure drops of all cloth masks were 1.2-2.0 times lower after washing. Conclusions: The filtration efficiencies of the five cloth masks were below 30% and did not improve greatly by increasing the number of layers. After a single washing, their performances decreased. Considering the above and other issues identified with cloth masks, such as poor fit and stretched fibers through use, people should not expect protection against particulate matters from the cloth masks on the market.