• 제목/요약/키워드: Pressure drop rate

검색결과 656건 처리시간 0.031초

25mm NSW-ring, pp.를 충진한 충진탑에서 암모니아 흡수에 의한 유해가스 처리시 충진물의 특성연구 (A Study on Charateristic of Modern Packing, 25mm NSW-ring, ppm by Absorption of NH3 gas)

  • 신은재;박진식
    • 한국환경과학회지
    • /
    • 제6권4호
    • /
    • pp.391-397
    • /
    • 1997
  • The study was carried out to demonstrate the superiority of used packing in view of energy saving and efficiency of mass transfer, comparing with conventional packing. The results are as follows : 1. Owing to low Pressure drop under high load. 25mm NSW-ring, pp. can cause energy saving 2. The unique magnitudes of used packing are as follows $C_G$=5.78, m=0.67, n=0.46 3. Used packing can make high efficiency including energy saving because of low pres sure drop per the number of transfer unit. To rate the characteristic of packing, It should be carried out that the measurement of pressure drop per packing height and per the number of transfer unfit. This study demonstrated the superiority of used packing by carring out above experiment and could be used as basic reference for design and predicting efficiency of packing tower which is tilled with same packing.

  • PDF

오리나무 열매를 이용한 생물처리장치에서의 톨루엔 가스 처리효율 특성 (Characterization of Toluene Vapor Removal Efficiency Using Alnus Firma Fruit in a Biological Treatment Process)

  • 공남식;차수길;서정윤
    • 한국대기환경학회지
    • /
    • 제19권6호
    • /
    • pp.689-699
    • /
    • 2003
  • This study was to examine characteristics of treating toluene vapor, which gets to be problematic due to its harmful carcinogenicity and mass generation from various sources, through a biological treatment facility which is environment-friendly and adopts a high-efficient and low-cost clean technology. In order to identify whether Alnus Firma Fruit (AFF) can be used as a media for a bioreactor, its utility and basic operating factors, a study was conducted on pressure drop, supply of nutrient substances and retention time which are operating factors of a biofilter, and eliminating characteristics were compared between AFF and the conventional biological activatedcarbon (BAC) widely used as filter media. In the case of AFF, the initial microbial deposits was 2.3${\times}$10$^{7}$ CFU/g dry AFF, which represents the initial microbial density higher than the case of BAC showing 5.5${\times}$10$^{6}$ CFU/g dry BAC And it took about 2 weeks to acclimate until its eliminating rate got to be increased over 90%. As a result of comparing pressure loss taking place with the lapse of time between BAC and AFF, after 130 days passed at SV 25h$^{-1}$ , BAC showed that its eliminating efficiency had a tendency to drop greatly due to a great pressure loss (0.53\longrightarrow54.7 mm$H_2O$/m) caused by an excess of biomass as accumulated. On the other hand. AFF showed that the pressure drop was 0.53 mm$H_2O$/m, about 2 times as much as the initial pressure loss of 0.4 mm$H_2O$/m, which represents no great change in the pressure loss, and its eliminating efficiency was also shown to be continuously high. Therefore, when AFF was used as a filler for a biological treatment facility, a biological filter enabling improvement of the purifying efficiency to be promoted could be provided, and moreover, the pressure loss was so small that the filler replacement cycle or the back flushing cycle could be extended. So, even in terms of the operating cost, it was identified to be an economical filler When an inorganic material was used as a filler, the biofilters performance acted sensitively on whether nutrient substances were supplied or not. In the case of AFF with low adsorptivity, addition of ethyl-alcohol increased the solubility of toluene, and consequently, biodegradation got to be actively made by microbes, and thus, its eliminating rate could be increased. As the flow velocity and the inflow concentration got to be more increased, its eliminating rate got to be lower, and particularly, an increase in the flow velocity made its eliminating rate drop more greatly than an increase in the concentration.

루버형과 파형핀 열교환기에서 분진이 성능에 미치는 영향에 관한 연구 (A Study of Dust Effect on Performance of Heat Exchangers with Louver and Wavy Fins)

  • 이영림;황순호
    • 한국자동차공학회논문집
    • /
    • 제17권4호
    • /
    • pp.126-132
    • /
    • 2009
  • Automotive heat exchangers use louver fins for their high efficiency. However, the efficiency can significantly drop for constructional vehicles or heavy equipments due to dust deposited on the louver fins with narrow slits. Thus it is necessary to develop new fins that lead to less fouling, so that a better performance can be achieved after exposure to a dusty environment over long period of time. New wavy fins were considered in the study and numerically analysed to compare with louver fins in the areas of air-side pressure drop, heat release rate, and particulate deposition. In addition, an experiment was done on the pressure drop and the particulate deposition. The results showed that the wavy fins would be a better choice for long-term use due to the excellent dust-proof performance in comparison to louver fins, in spite of the initial inferior performance of heat release.

용접형 판형열교환기 성능측정에 관한 실험적 연구 (An Experimental Study on the Performance of Brazed Plater Heat Exchangers)

  • 박현민;박창용
    • 한국생산제조학회지
    • /
    • 제22권3_1spc호
    • /
    • pp.551-557
    • /
    • 2013
  • The heat transfer performance and pressure drop characteristics of brazed-plate heat exchangers with 20 and 30 plates were experimentally measured and analyzed in this study. The mass flow rates of the heat exchangers with 20 and 30 plates were fixed at 0.6 and 0.9 kg/s for the low temperature side, respectively. The mass flow rate for the high temperature side was controlled from 0.2 kg/s to 1.2 kg/s. The inlet temperatures for the high and low temperature sides were $10^{\circ}C$ and $7^{\circ}C$, respectively. The heat transfer characteristics were not influenced by the number of plates. The pressure drop at the heat exchanger with 30 plates was slightly higher than that with 20 plates. The values calculated from the correlations based on gasket plate heat exchangers were compared with the experimental results. It was found that the predicted Nusselt numbers for the gasket plate heat exchangers were about 5% to 20% lower than the measured Nusselt numbers for the brazed plate heat exchangers. However, a pressure drop comparison showed that the calculated pressure drops at the gasket plate heat exchangers were less than half of the measured pressure drops at the brazed plate heat exchangers.

고압 호스에서 굽힘의 각도가 압력 변화에 미치는 영향에 대한 수치해석적 연구 (Numerical Study on The Effect of Bending Angle on Pressure Change in High Pressure Hose)

  • 홍기배;김민석;유홍선
    • 한국산업융합학회 논문집
    • /
    • 제25권1호
    • /
    • pp.61-70
    • /
    • 2022
  • Fire damage time in high-rise buildings and wildland fire increasing every year. The use of high-pressure fire pumps is required to effectively extinguish fires. Reflecting the curvature effect of the fire hose occurring at the actual fire fighting site, this study provides a database of pressure drop, discharge velocity and maximum discharge height through C FD numerical analysis and it can provide using standards for fire extinguishing. Two Reynolds numbers of 200000 and 400000 were numerically analyzed at 0° -180° bending with water of 25℃ as a working fluid in hoses with a diameter of 65mm, a length of 15m, and a radius of curvature of 130mm. Realizable k-ε turbulence model was used and standard wall function was used. The pressure drop increases as the bending angle increases, and the maximum value at 90° and then decreases. The increasing rate is greater than the decrease. The velocity of the secondary flow also decreases after having the maximum value at 90°. The decreasing rate is greater than the increase. The turbulent kinetic energy increases to 120° and decreases with the maximum value. Pressure drop, velocity of the secondary flow, and turbulence kinetic energy are measured larger in the second bending region than in the first bending region.

아이스슬러리형 빙축열 시스템을 이용한 냉각 시스템의 성능에 관한 실험적 연구 (Characteristic Analysis of the Cooling System Using Ice Slurry Type Heat Storage System)

  • 이동원;김정배
    • 에너지공학
    • /
    • 제20권1호
    • /
    • pp.30-35
    • /
    • 2011
  • 2중관형과 판형 열교환기에 에틸렌 클리콜-물 수용액으로 만들어진 아이스슬러리를 적용하는 경우의 유동 및 열적 특성을 규명하기 위하여 실험을 수행하였다. 아이스슬러리의 질량유속과 얼음 분율은 각각 800에서 3500 kg/$m^2s$과 0에서 25%이었다. 실험을 통해, 압력강하와 열전달율은 질량유속과 얼음 분율에 따라 증가하였다. 그러나 얼음 분율의 효과는 높은 질량유속 영역에서는 크지 않은 것으로 나타났다. 낮은 질량유속에서는 압력강하와 열전달율의 급속한 증가가 질량 유속에 관계되는 것으로 나타났다.

자동차 에어컨용 평행류 응축기의 성능평가 (Performance Evaluation of a Parallel Flow Condenser for Automotive Air Conditioners)

  • 장혁재;강병하
    • 설비공학논문집
    • /
    • 제15권4호
    • /
    • pp.247-253
    • /
    • 2003
  • The new shape of louver-fin has been applied to a parallel flow condenser to enhance air-side heat transfer rate lot an automotive air-conditioner R- l34a is employed as a refrigerant inside the flat tube of the condenser, This problem is of particular interest in reducing the geometric size of the automotive air conditioner The effect of air flow rate on pressure drop as well as heat transfer in air side are studied in detail. Comparison of the performance is also made with that of a conventional parallel flow condenser, which is available in the market. The results obtained indicate that the total pressure drop through the pre sent condenser is not changed, while the heat transfer rate is increased by 24% at high veto city of air flow, compared with those of the conventional condenser. The parallel flow condenser with a new shape of louver-fin could be reduced in size by 20% for the equivalent condenser capacity, compared with the conventional parallel flow condenser.

다양한 전열관 내부 홈 변화에 의한 열전달 성능에 관한 연구 (A Study on the Heat Transfer Performance Using Various Grooved Heat Transfer Tubes)

  • 한규일;정원규;예석수;박성현
    • 동력기계공학회지
    • /
    • 제4권1호
    • /
    • pp.26-32
    • /
    • 2000
  • Single-phase heat transfer performance and pressure drop for internally grooved tubes with angles were studied. Experiments were carried out in a counter flow heat exchanger with water as a working fluid. Two commercially available internally grooved tubes and smooth tube were tested. The internal diameter of the smooth tube was 16.5mm and the internal diameters of grooved tubes were 15.4mm, 14.9mm, 15.0mm, 16.7mm, respectively. Grooved angles in the tubes were $37^{\circ},\;43^{\circ},\;45^{\circ},\;50^{\circ}$, respectively. An experimental device to measure the friction factor and heat transfer coefficient was constructed. The experimental results were obtained for the fully developed turbulent flow of water in tube on the condition of uniform heat flux. As the increase of flow rate, Reynolds number, numbers of groove and grooved angle led to the increase of pressure drop. Also this paper showed that heat transfer rate increased with increasing numbers of groove and grooved angle. An empirical relation taken from this study represented most of the data within ${\pm}25%$.

  • PDF

필터 조밀도의 영향에 의한 3단 필터 시스템의 유동특성 해석 (Analysis of Flow Characteristics of Triple Filter System by the Influence of Filter Density)

  • 손인수
    • 한국산업융합학회 논문집
    • /
    • 제26권6_2호
    • /
    • pp.1163-1169
    • /
    • 2023
  • In this study, the flow characteristics of the filter system were analyzed due to the effect of the density of the filter in the triple filter system. Flow analysis was performed as a flow passing through a porous medium. The flow characteristics of each filter system were analyzed by arranging filters with different densities in the forward flow flow and the reverse flow. The arrangement order of the triple filters was excellent in the case of forward fluid flow and in the case of higher density from the inside to the outside filter. In the reverse flow filter system, the performance of the system was the best in the case of reverse order filter arrangement. As a result of the analysis, Case II, which showed a pressure drop rate of 5.65% for forward flow, was the best in the reverse direction with a pressure drop rate of 14.25%. Considering reverse and forward flows, it was found that the optimal filter arrangement was most effective when the intermediate filter was the densest, and the inner or outer filter was less dense.

입자상물질과 Ash양이 디젤매연여과장치 내의 배압 및 유동균일도에 미치는 영향 (Effect of Particulate Matter and Ash Amount on Pressure Drop and Flow Uniformity of Diesel Particulate Filter Reduction System)

  • 김윤지;한단비;서태원;오광철;백영순
    • 청정기술
    • /
    • 제26권1호
    • /
    • pp.22-29
    • /
    • 2020
  • 최근 미세먼지 증가로 인하여 디젤엔진의 배출 규제가 강화됨에 따라 디젤 매연여과장치에 관심이 급증하게 되었으며, 특히 디젤 배기가스 후처리 장치의 고효율화에 대한 기술개발이 더욱 요구되고 있다. 이에 대한 일환으로서 디젤매연여과장치(diesel particulate filter, DPF) 내 배기가스의 유동 균일도를 향상시키고 배압을 낮추어서 배기가스처리 효율을 높이는 연구가 많이 되고 있다. 본 연구에서는 ANSYS Fluent를 이용하여 직경 12"의 DPF와 디젤산화촉매(diesel oxidation catalyst, DOC)를 장착한 디젤 매연여과장치에서의 배기가스의 유속과 온도, DPF IO ratio, Ash와 PM양에 따른 배압에 미치는 영향을 시뮬레이션 하여 배압을 낮추는 최적화 연구를 하였다. 결과로서 배기가스의 온도와 유속이 낮을수록 배압이 낮아졌으며, PM양이 Ash양보다 배압에 더 큰 영향을 주는 것으로 나타냈다. 또한 비대칭 DPF가 대칭 DPF에 비해 배압이 더 낮게 나타냈으나, 유동 균일도의 경우는 다양한 변수에 관계없이 일정하게 나타냈다. european stationary cycle (ESC), european transient cycle (ETC) 조건에서 PM의 정화효율은 비대칭, 대칭 DPF 관계없이 유사하나, particle number (PN)의 정화효율에서는 비대칭 DPF가 대칭 DPF에 비해 높게 나타냈다.