• 제목/요약/키워드: Pressure capacity

Search Result 1,698, Processing Time 0.027 seconds

Uplift Capacity and Creep Behavior of Concrete Pile Driven in Clay (점토지반에 타입된 콘크리트 말뚝의 인발저항 및 크리프 거동)

  • 신은철;김종인;박정준;이학주
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2001.03a
    • /
    • pp.371-378
    • /
    • 2001
  • The working load at pile is sometimes subjected to not only compression load but also lateral load and uplift forces. Pile foundation is essential and uplift load can be applied because of buoyancy, a typhoon, wind or seismic forces. This study was carried out to determine the uplift capacity of concrete pile foundation driven in clay. Pile was driven in clay, between pile and clay adhesion factor was estimated, and it is the mean value between the cast-in-situ-pile and steel pipe pile. When pile foundation is loaded for long time, creep behavior occurs. The behavior of creep is originated from the clay creep contacted with pile. The creep behavior of pile foundation embedded in clay is heavily depended on the thickness of clay around the pile shaft, pore water pressure in clay, and creep behavior of clay.

  • PDF

Removal of Hydrogen Sulfide Using Porous Ceramic Biofilter Inoculated with Sulfur Oxidizing Bacteria (황산화 균주가 부착된 다공성 세라믹 biofilter를 이용한 $H_2S$ 제거)

  • 박상진;조경숙
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.15 no.5
    • /
    • pp.649-655
    • /
    • 1999
  • Biofiltration of polluted gas streams contained $H_2S$ was studied. The experiments were performed in a laboratory-scale reactor with a porous ceramic media inoculated with sulfur oxidizing bacterium, TAS which was isolated from activiated sludge. The concentration of $H_2S$ in the inlet gas varied from 109 to 3,841 ppm, at the various space velocities(SV) of 50 $h^{-1}$ to 250 $h^{-1}$. Various tests have been conducted to evaluate the effects of such parameters as pH, concentration of sulfate ion and retention time on the pressure drop and maximum elimination capacity. The removal efficiency of $H_2S$ decreased as the $H_2S$ concentration or gas velocity increased in the inlet gas. Pressure drop was insignificant in this system. The maximum elimination capacity could reach up to 16.35g-S/kg-dry packing material/day.

  • PDF

Laboratory Test and Field Study of Soft Ground Improvement Effect by Using Various PVDs (실내실험과 현장실험을 통한 다양한 PVD의 연약지반개량효과)

  • Shin, Eun-Chul;Nazarova, Zhanara
    • Journal of the Korean Geosynthetics Society
    • /
    • v.7 no.2
    • /
    • pp.15-21
    • /
    • 2008
  • The advantages of prefabricated vertical drains over conventional sand drains include their relatively low costs, less disturbance to the soil mass, the easinees of installation, and their flexibility which ensures the integrity of the drains during installation. This study tested the change of discharge capacities with respect to the hydraulic gradients for each lateral pressure. From the test results, as increases the overburden pressure, the clay soil is being consolidated, and also lateral pressure to the PVD specimen is increased. Therefore, the discharge capacity is decreased. The size of opening space in the core of PVDs is proportionally related to the discharge capacity. The numerical analysis was performed with utilizing computer simulation with considering field conditions. The results of numerical analysis are compared well with the field measurements.

  • PDF

Diurnal changes of Tissue Water Relations in Two Allopatric Tree Species (이소적 두 수종의 수분관계 일변화)

  • Park, Yong-Mok
    • The Korean Journal of Ecology
    • /
    • v.19 no.5
    • /
    • pp.453-463
    • /
    • 1996
  • Diurnal changes of microclimatic conditions and tissue water relations were measured at two sites where Carpinus laxiflora and C. cordata were allopatrically distributed. The microclimatic conditions at a site where C. laxiflora was distributed produced severe water stress condition during summer months. Daily maximum temperature reached $30.4^\circC$ and the highest vapor pressure deficit was 1.31 KPa when 13 rainless days were continued. During this period soil water content decreased to below the field capacity even at a depth of 20 cm and xylem pressure potential also decreased to ­2.04 MPa. However, turgor potential was maintained more than 0.4 MPa. Patterns of stomatal conductance were changed with evaporative demand and soil water availability. On the other hand, microclimatic conditions at a site where C. cordata was distributed were moderate water strees condition compared with those at a site C. laxiflora was distributed. Though soil water content was maintained above field capacity C. cordata showed a remarkable decrease in turgor potential and stomatal conductance throughout the experiment. These results indicate that there is a difference in habitat characteristics between the two species and C. laxiflora is more resistant than C. cordata to water stress.

  • PDF

Gait Training Strategy Focusing on Perceptual Learning for Improved Gait Capacity in Stroke Survivors

  • Jung, Jee Woon
    • The Journal of Korean Physical Therapy
    • /
    • v.32 no.5
    • /
    • pp.283-289
    • /
    • 2020
  • Objective: The purpose of this study was to determine the force of lower extremities, the change in walking ability on the ground by applying a walking training program based on perceptual learning to improve gait capacity of chronic stroke patients. Method: This study included Twenty-four patients with chronic stroke. Using a perceptual-based gait training, the experimental group trained twice a day for 30 minutes each time, 5 times a week, for a total of 8 weeks. The control group underwent ground gait training that excluded the element of a perceptual training for 30 minutes, 5 times a week for 8 weeks. Results: In the two groups, the maximum forefoot pressure after intervention was significantly different in both the LEPGT and GGT (p<0.05). The maximum midfoot pressure was significantly different in LEPGT (p<0.05). There was a significant difference in the maximum heel pressure after intervention between the two groups (p<0.05). As a result of comparing the change in step length and stride length after intervention in the two groups, there was a significant difference between the two groups (p<0.05). Conclusion: Both gait training programs was found that gait training based on perceptual learning and ground gait training were the training for improving the functional gait of stroke patient. Perceptual learning gait training utilizing intensive perceptual awareness was the training for improving gait capacity within the period than ground gait training.

A Study of Joint Characteristic of BSCCO Superconductor Tape (BSCCO 고온초전도 선재의 접합특성 연구)

  • Kim, Jung-Ho;Kim, Joong-Seok;Kim, Tae-Woo;Ji, Bong-Ki;Joo, Jin-Ho;Nah, Wan-Soo
    • 한국초전도학회:학술대회논문집
    • /
    • v.9
    • /
    • pp.378-382
    • /
    • 1999
  • We evaluated the effect of joining process such as contact method, shape of joined area and pressure on the electrical property of Bi-2223 superconducting tape. It was observed that the current capacity was reduced at the transition area of the joined tape and was significantly dependent on the uniaxial pressure. The lap-joined tape, fabricated with a pressure of 1,000-1,600 MPa, show the highest value of current capacity(80-90%) of the tape itself. It is believed the highest value of current capacity results from improvement in core density, contacting area and grain alignment, etc. In addition, the irreversible strain( ${\varepsilon}$ irrev) for the joined tape· was measured to be 0.1%, smaller than that of enjoined tape( ${\varepsilon}$ irrev = 0.3%). The decrease in the strength and irreversible strain for joined tape is believed to be due to the irregular geometry/morphology of the transition area of the tape.

  • PDF

Gas Leakage Condition and CFD analysis on Gas Fuelled ship FGS system (Gas Fuelled Ship FGS 시스템에 대한 가스누출 조건 검토 및 CFD 해석)

  • Kim, Ki-Pyoung;Kang, Ho-Keun;Park, Jae-Hong;Choung, Choung-Ho
    • Proceedings of the Korean Society of Marine Engineers Conference
    • /
    • 2011.06a
    • /
    • pp.7-10
    • /
    • 2011
  • According to the requirement of Res.MSC.285(86) for natural gas-fueled engine installations in ships, pump and compressor rooms should be fitted with effective mechanical ventilation system of the under pressure type, providing a ventilation capacity of at least 30 air changes per hour. It generally considered that gas leakage is more likely from a Fueled Gas Supply System(FGS) room as compared to other places, where installed in many kind of machinery or equipments like gas supply high-pressure pipes, valves, flanges and etc. Furthermore, leaked gas may be dispersed in a short time in an enclosed space, especially a FGS room, due to high pressure. However, the present requirement in Res.MSC.285(86) just considers the ventilating capacity of air changes per hour but the capacity of leaked gas. Hence, the current requirements may not meet effectively when enforcing the new propulsion systems as marine fuel. This study is conducted for the purpose of safety evaluation about the dispersion and ventilation efficiency with estimated leakage scenario. Numerical analysis predictions as the result of this paper are explained to know the features of flow pattern and the diffusion of natural gas concentration.

  • PDF

An experimental study of the air-side particulate fouling in finned-tube heat exchangers of air conditioners through accelerated tests (공기조화기용 열교환기의 공기측 파울링 가속 특성 분석)

  • Ahn, Young-Chull;Cho, Jae-Min;Lee, Jae-Keun;Lee, Hyun-Uk;Ahn, Seung-Phyo;Youn, Deok-Hyun;Kang, Tae-Wook;Ock, Ju-Ho
    • Proceedings of the KSME Conference
    • /
    • 2003.04a
    • /
    • pp.1857-1862
    • /
    • 2003
  • The air-side particulate fouling in the heat exchangers of HVAC applications degrades the performance of cooling capacity, pressure drop across a heat exchanger, and indoor air quality. Indoor and outdoor air contaminants foul heat exchangers. The purpose of this study is to investigate the fouling characteristics trough accelerated tests. The fouling characteristics are analyzed as functions of a dust concentration (1.28 and 3.84 $g/m^3$), a face velocity (0.5, 1.0, and 1.5 m/s), and a surface condition. The cooling capacity in the slitted finned-tube heat exchangers at the face velocity of 1 m/s decreases about 2% and the pressure drop increases up to 57%. The rate of build-up of fouling is observed to be 3 times slower for this three-fold reduction of dust concentration whilst still approaching the same asymptotic level.

  • PDF

Modeling of the Air-side Particulate Fouling in Finned-Tube Heat Exchangers of Air Conditioners using Accelerated Particle-Loading System (파울링 가속장치를 이용한 공기조화기용 열교환기의 공기측 파울링 특성에 대한 예측 모델링)

  • Ahn Young-Chull;Lee Jae-Keun
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.17 no.3
    • /
    • pp.262-267
    • /
    • 2005
  • The air-side particulate fouling in the heat exchangers of HVAC applications degrades the performance of cooling capacity, pressure drop across a heat exchanger, and indoor air quality. Indoor and outdoor air contaminants foul heat exchangers. The purpose of this study is to investigate and to model the air-side particulate fouling characteristics of the heat exchangers using accelerated particle loading system. The main variables of the modeling equation are face velocity and dust concentration. The modeling equation shows good agreements with the experimental results at the face velocity of 0.5, 1.0, 1.5 m/s and the dust concentration of 1.28 and $3.84\;g/m^3$. It will be very useful to predict fouling characteristics such as variations of pressure drop and heat transfer capacity in finned-tube heat exchangers of air conditioners.

Improvement of Soft Ground by Using Recycled Aggregates (재생골재를 이용한 연약지반개량)

  • Lee, Dal-Won;Lee, Jung-Jun;Kim, Si-Jung
    • Korean Journal of Agricultural Science
    • /
    • v.37 no.1
    • /
    • pp.97-104
    • /
    • 2010
  • In this study, a laboratory model test on utilization of recycled aggregates and crushed stone as vertical drains to use alternative material of sand in soft ground is performed. The vertical and horizontal coefficient of permeability of the recycled aggregates and crushed stone showed largely 1.2~4.0 times and 3.0~3.3 times greater than sand, respectively. Therefore, it showed enough to be an alternative material to the sand which had been being used as the vertical and horizontal drainage material before. The variations of pore water pressure with time showed constantly regardless of the load in all vertical drainage materials. When water level drops suddenly, the pore water pressure of the recycled aggregate and crushed aggregate is reduced to nearly zero. Therefore, it was applicable to the field because discharge capacity was similarity to that of sand. The settlement in crushed aggregates and recycled aggregate decreases gradually with the load increase. When water level drops suddenly, earth pressure in all drains materials was evaluated the equivalent drainage capacity similarity to sand because it show approaching the nearly zero.