• 제목/요약/키워드: Pressure balancing valve

검색결과 9건 처리시간 0.021초

피스톤 형상변화에 따른 압력평형밸브의 유동특성연구 (Flow Characteristics of Pressure Balancing Valve with Various Piston Shapes)

  • 김태안;안병재;김윤제
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2003년도 춘계학술대회
    • /
    • pp.2168-2173
    • /
    • 2003
  • Pressure balancing valve is one of important control devices, which is fully automatic and no manual controls, regulating or adjustments are needed. It is typically used to maintain constant temperature of working fluid in power and chemical plants and domestic water supply systems. Pressure balancing valve is composed of body, cylinder and balancing piston. Therefore, the balancing piston shapes are important design parameters for a pressure balancing valve. In this study, numerical and experimental analyses are carried out with two different balancing piston shapes. Especially, the distribution of static pressure is investigated to calculate the flow coefficient($C_v$). The governing equations are derived from making using of three-dimensional Navier-Stokes equations with standard ${\kappa}-{\varepsilon}$ turbulence model and SIMPLE algorithm. Using commercial code, PHOEIC, the pressure and flow fields in pressure balancing valve are depicted.

  • PDF

압력평형메커니즘을 이용한 초소형 수동형 기체 압력조정기 (A Micro Passive Gas Pressure Regulator using Pressure Balance Mechanism)

  • 이기정;양상식
    • 전기학회논문지
    • /
    • 제59권1호
    • /
    • pp.138-143
    • /
    • 2010
  • This paper presents the analysis, the fabrication and the test results of a micro passive gas pressure regulator to keep the outlet pressure costant even for a widely-varying inlet pressure. This device is to regulate the outlet pressure according to the applied reference pressure based on the pressure balancing mechanism of the structure including a membrane and a valve. This regulator consists of four layers; a bulk-micromachined silicon substrate, a sandblasted glass substrate, a PDMS valve seat layer and a glass valve layer. The device size is $10\times13\times1.7 mm3$. The device was fabricated by micromachining. The characteristic of the device was analyzed and tested. The characteristic of the fabricated pressure regulator is similar to that obtained from the analysis. The pressure regulator of this paper is feasible for portable systems and miniature drug delivery systems.

가변유량 밸런싱밸브를 적용한 온수 난방시스템의 유체역학적 성능 평가 (Fluid Dynamic Performance in a Hot-Water Heating System with a Variable-Flow-Rate Balancing Valve)

  • 허전;이석종;성재용;이명호
    • 설비공학논문집
    • /
    • 제19권8호
    • /
    • pp.577-584
    • /
    • 2007
  • A variable-flow-rate balancing valve has been developed and optimized to apply to a distributor in a hot-water heating system. Fluid dynamic performance of the system was evaluated by comparing the results with the previous pressure difference control valve (PDCV) system. In view of the variations of pressure drop and flow rate according to the sequential closing of the control valves, the present system which is named "smart system distributor", is very stable without a certain flow rate concentration. The level of pressure drop variation is also low as compared with the previous system with a PDCV. In view of the occurrence of cavitation, the present system is quite superior to the previous system because the instantaneous pressures at all sections are much higher than the vapor pressure. On the other hand, the previous system has a possibility of cavitation when one or more control valves are closed.

산화제 개폐밸브의 극저온 유동시험에서 채터링의 고찰 (A Study on the Chattering under Cryogenic Flow Test of a Oxidizer Shutoff Valve)

  • 이중엽;한상엽;이수용
    • 항공우주기술
    • /
    • 제12권2호
    • /
    • pp.108-117
    • /
    • 2013
  • 가스발생기용 산화제 개폐밸브는 파일롯 공압으로 포핏을 열고 스프링 힘에 의해 닫음으로써 로켓엔진의 추진제 유량을 제어한다. 현재 개발 중인 산화제 개폐밸브는 액추에이터에서 압력을 제거하면 닫히도록 설계되어 있다. 그러므로 밸브의 성능을 평가하기 위해 밸브가 열리고 닫히는 특성에 따라 힘 평형 상태를 분석할 필요가 있다. 밸브가 닫히기 시작하는 시점의 작동 유체의 압력을 결정하고, 포핏이 열리는 시점의 압력을 결정되어 힘평형이 설계되어 있다. 인증시험 수준에서의 극저온 유동 시험 하에서 채터링 현상은 금속 기밀부에서 다량의 누설이 발생했다. 힘평형 계산을 이용한 산화제 밸브의 채터링이 발생된 시점의 압력은 약 11 bar로 예측 된다.

공동주택 온수난방 시스템의 적정 열공급을 위한 배관망 시뮬레이션 (Simulation of Pipe Network for Optimum Heat Supply in the Hot Water Heating System of Apartment House)

  • 김주용;민만기;최영돈
    • 설비공학논문집
    • /
    • 제5권3호
    • /
    • pp.157-168
    • /
    • 1993
  • Pipe network of hot water heat supply system in an apartment house was analyzed. Flowrate and supply heat capacity of each household in which constant flowrate balancing valve is installed in a single zone system were calculated and the results were investigated. In the existing piping system, the non-uniformity of heat supply with floors due to the static pressure and temperature difference between supply main and return main can not be avoided and this tendency get intense with the increase of the height of building. The non-uniformity of heat supply can be prevented by the installation of balancing valve at each household, however if the performance of supply pump is not sufficient to overcome the energy loss due to the installation of balancing valve for constant flow rate or if the selection of the valve capacity is not adequate, the valves will may lose their controllability.

  • PDF

공동주택단지에 설치된 부스터펌프 급수설비계통의 유동 특성 (Flow Characteristics of a Water Supply System with Booster Pumps for an Apartment Complex)

  • 오양균;정재봉;박미라;차동진
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2008년도 동계학술발표대회 논문집
    • /
    • pp.151-156
    • /
    • 2008
  • Water flow characteristics of an apartment complex consisting of 12 buildings and 635 units in total have been investigated numerically. The complex incorporates two zone booster pump water supply system, and some units have pressure reducing valves in them. Input data to a commercial code Flowmaster7 include survey results on the water usage for the last three years, dimension of the water supply system and its operation condition, etc. Calculated static pressures at the inlet of all units are compared with their design and measured counterparts, and they agree quite well with each other. Then, the pressure distributions and volumetric flow rates at all 635 units are estimated. Flow balancing is also attempted by varying the ratio of angle valve of each unit to improve the non-uniformity of flows.

  • PDF

실별제어 온수분배기의 유량분배 특성 (A Flow Quantity Distribution Characteristics of the Hot Water Header for Individual Room Control System)

  • 성순경
    • 설비공학논문집
    • /
    • 제20권3호
    • /
    • pp.175-180
    • /
    • 2008
  • Flow quantity to supply to a coil in floor heating system is important to achieve comfortable indoor air condition in the winter season. The hot water header is used to distribute the water into the coil. Experimental study has been performed using the water header that have 5 branches consisted of flow control valves and automatic shut-off valves. Each branch line connected it with X-L pipe. Experimental tests accomplished it to investigate the flow distribution characteristics of the hot water header. Experimental results show that the selection of the pump head and differential pressure are very important to save running energy of the system, and high differential pressure needs more friction loss in the case of suitable differential pressure for balancing of the header.

유압 피스톤모터용 Slipper Pad의 정압시험에 관한 연구 (A Study on the Hydrostatic Test of Slipper Pad for Hydraulic Piston Motor)

  • 함영복;김광영;김형의
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 1997년도 춘계학술대회 논문집
    • /
    • pp.645-649
    • /
    • 1997
  • In case of swash plate type axial piston hydraulic motor, hydrostatic bearing used to achieve the lubrication effect on the mechanical sliding contact areas between the following parirs ; sliooer-pad and swash plate,piston and cylinder bore,valve plate and cylinder block, etc. This study discussed the basic charateristic for the hydrostatic slipper-pad bearings with the capillary or orifice restrictor under static load condition. And, we also development of hydrostatic bearing tester for hydrostatic balancing test of pistion & slipper-pad assembly, and some experimental data on supply pressure step responce are reported.

  • PDF

발전소 정전사고 시 Hybrid SIT의 냉각성능 평가를 위한 안전해석에 관한 연구 (Study on the Safety Analysis on the Cooling Performance of Hybrid SIT under the Station Blackout Accident)

  • 류성욱;김재민;김명준;전우진;박현식;이성재
    • 에너지공학
    • /
    • 제26권3호
    • /
    • pp.64-70
    • /
    • 2017
  • 한국원자력연구원에서 제안한 혼합형 안전주입탱크 (Hybrid SIT)는 APR+ 원자로에 적용하기 위해 개발된 피동안전주입시스템이다. 본 연구는 대표적인 고압사고인 발전소정전사고 시 Hybrid SIT의 냉각성능을 평가하기 위해 열수력 안전해석 코드인 MARS-KS 코드를 이용한 예비해석에 대한 것이다. PAFS 구동이 정지되면, 열제거량이 감소하게 되어 가압기와 증기발생기의 압력이 상승하기 시작하며, 가압기의 압력이 안전감압계통(Pilot Operated Safety and Relief Valve) 개방 설정치인 17.03 MPa에 도달하면, 그와 동시에 Hybrid SIT의 증기격리밸브가 열림으로서 가압기 상단의 증기가 Hybrid SIT로 주입되게 된다. 주입된 증기에 의해 압력평형이 빠른시간 안에 이루어졌으며, 주입배관을 통해 냉각수가 주입 되었다. 발전소정전사고시 PAFS와 같은 열제거수단이 상실됨에도 혼합형 Hybrid SIT가 주입되는 시간동안은 노심의 수위가 유지됨을 확인할 수 있었고, 수위가 유지됨에 따라 노심 출구 온도(CET)의 상승을 방지함을 확인하였다.