• Title/Summary/Keyword: Pressure Test

Search Result 7,913, Processing Time 0.034 seconds

Evaluation of Muscle Activity and Foot Pressure during Gait, and Balance Test in Patients with Genu Valgum (무릎외반의 균형 검사 및 보행 중에 근활성도와 발바닥압의 평가)

  • Yoon, Jeong-Uk;Yoo, Kyung-Tae;Lee, Ho-Seong
    • Journal of the Korean Society of Physical Medicine
    • /
    • v.17 no.1
    • /
    • pp.127-137
    • /
    • 2022
  • PURPOSE: This study sought to evaluate muscle activity and foot pressure during gait, and balance in female college students with genu valgum. METHOD: Participants were assigned based on their Q-angle to genu valgum group greater than 20° (GVG, n = 12), unilateral genu valgum group greater than 20° (UVG, n = 11), and control group (CON, n = 13). All subjects were evaluated for balance (Trace length, C90 area, C90 angle, and the Romberg test), muscle activity (gluteus medius; GM, tensor fasciae latae; TFL, vastus medialis; VM, vastus lateralis; VL, biceps femoris; BF, gastrocnemius; GCM and tibialis anterior; TA) and foot pressure (F/F ratio, R/F ratio, Hallux, 2~5 toe, 1st MT, 2~4 MT, 5th MT, Midfoot, M/heel, and L/heel) during gait. RESULTS: Romberg test showed significantly increased loss of balance in the UVG group compared with the CON. In the forward position, the imbalance was significantly increased in the UVG and GVG groups compared to the CON. Muscle activity of VL, GCM, and TA significantly increased in the GVG group compared with the CON. Static foot pressure, 1st MT significantly increased in the GVG compared to the CON group. The 5th MT significantly decreased in the CON compared with the GVG group. The R/F ratio significantly decreased in the GVG compared to the CON group. In dynamic foot pressure, the 2~5 toe significantly increased in the GVG compared with the UVG group. The left 5th MT significantly decreased in the UVG compared with the CON and GVG groups. CONCLUSION: These results indicate that genu valgum has a negative effect on balance, muscle activity, and foot pressure during gait in female college students.

Effect of Ground Confine Pressure on Pullout Resistance of Piles Using Model Experiment (말뚝의 인발저항에 대한 지중 구속압 영향 분석을 위한 실내모형실험)

  • Seung-Kyong You;Gigwon Hong
    • Journal of the Korean Geosynthetics Society
    • /
    • v.22 no.4
    • /
    • pp.27-34
    • /
    • 2023
  • This paper describes the results of a pile pullout test considering the confine pressure and fines content of the ground. The Pullout tests were conducted under various ground conditions using model piles. The effect of ground confine pressure on the pullout resistance and the pullout resistance parameters of the pile were evaluated based on the experimental results. The results of pullout test showed that the maximum pullout resistance occurred at a pullout displacement of about 7mm to 9mm, regardless of the fines content and the confine pressure of the ground. The maximum pullout resistance of the pile decreased as the fines content of the ground increased, and this trend became clearer as the confine pressure increased. The pullout resistance calculated by theoretical formula was compared with the experimental results in order to ensure the reliability of the pullout test results. The comparative results showed that the experimental and theoretical values showed a tendency to decrease the pullout resistance as the fines content increased, in all confine pressure conditions. The analysis result of the pullout resistance parameters confirmed that the pullout resistance was greatly influenced by the adhesion compared to the interface friction angle, as the fines content of the ground around the pile increased.

Changes in The Pressure-Flow Control Characteristics of Shunt Valves Under Brain Pressure Pulsation (뇌압 펄스하에서 션트밸브의 압력-유량제어 특성곡선의 변화)

  • Hong Yisong;Lee Chong-Sun;Jang Jongyun
    • Proceedings of the KSME Conference
    • /
    • 2002.08a
    • /
    • pp.699-702
    • /
    • 2002
  • Shunt valves implanted in the subcutaneous tissue of brain to treat patient with hydrocephalus were numerically simulated to investigate influence of pressure pulsation on their flow control characteristics. Shunt valves are subjected to pressure variation since ventricles enclosing the brain are under pressure pulsation rather than uniform pressure due to blood pressure variation. We modeled flow orifice through shunt valve and imposed pulsating pressure and valve diaphragm movement to compute flow through the valve. The results of our study indicated that flow rate increased by $40{\%}$ by introducing pressure pulsation and diaphragm movement on the shunt valve. Our results demonstrate the pressure-flow control characteristics of shunt valves unplanted above human brain may be quite different from the characteristics obtained by syringe pump test with uniform pressure and no diaphragm movement.

  • PDF

Design and Test of ASME Strainer for Coolant System of Research Reactor (연구용 원자로 냉각계통의 ASME 스트레이너 설계 및 성능시험)

  • Park, Yong-Chul;Park, Jong-Ho
    • The KSFM Journal of Fluid Machinery
    • /
    • v.2 no.3 s.4
    • /
    • pp.24-29
    • /
    • 1999
  • The ASME strainers have been newly installed at the suction side of each reactor coolant pump to get rid of the foreign materials which may damage the pump impeller or interfere with the coolant path of fuel flow tube or primary plate type heat exchanger. The strainer was designed in accordance with ASME SEC. III, DIV. 1, Class 3 and the structural integrity was verified by seismic analysis. The screen was designed in accordance with the effective void area from the result of flow analysis for T-type strainer. After installation of the strainer, it was confirmed through the field test that the flow characteristics of primary cooling system were not adversely affected. The pressure loss coefficient was calculated by Darcy equation using the pressure difference through each strainer and the flow rate measured during the strainer performance test. And these are useful data to predict flow variations by the pressure difference.

  • PDF

Performance test of micronozzle (마이크로 노즐 성능평가)

  • Moon, Seong-Hwan;Oh, Hwa-Young;Huh, Hwan-Il
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.33 no.5
    • /
    • pp.72-78
    • /
    • 2005
  • We conducted the performance test of micronozzle having nozzle throat diameter of 1.0, 0.5, 0.25 mm in an ambient pressure. We used N2 gas as a cold gas propellant. We varied chamber pressure from 2 to 20 bar and measured the thrust and mass flow rate. Through the test, we concluded that viscous losses were increased with decreasing chamber pressure. We found that micronozzle performance was higher than orifice performance through thrust comparison.

A Study on Safety Design of Auxiliary tank in a high-pressure air compressor (고압공기압축기의 보조탱크 안전설계에 관한 연구)

  • 강동명;오진수;이장규;우창기
    • Proceedings of the Korean Institute of Industrial Safety Conference
    • /
    • 1997.11a
    • /
    • pp.31-36
    • /
    • 1997
  • Strength test using strain rosette gage have been conducted to investigate safety of an auxiliary tank in a high-pressure air compressor. Thickness of auxiliary tanks in 6063-T5 aluminum at toy are 9mm and 17mm. The result of strength test make a comparison the design in strength of materials by nominal stress and the design in fracture mechanics with consideration of crack size. Summarizing the result: Comparing with the safe working pressure of the strength test and that of the design method in strength of materials by nominal stress with the experimental values, it makes difference 11% and 39% for 9mm and 17mm thickness of auxiliary tanks, respectively, and that of the design method by fracture mechanics, it makes difference 4% and 5% for them, respectively. It is confirmed that the design by fracture mechanics is more economical and safe design than the design in strength of materials by nominal stress.

  • PDF

A Study on Applying Array Probe for Steam Generator Tube Inspection (배열형 탐촉자를 이용한 증기발생기 세관 검사 적용성 검토)

  • Kim, In Chul;Cheon, Keun Young;Lee, Young Ho
    • Transactions of the Korean Society of Pressure Vessels and Piping
    • /
    • v.5 no.1
    • /
    • pp.25-31
    • /
    • 2009
  • Steam Generator(SG) tube is an important component of Nuclear Power Plant(NPP), which comprises of the pressure boundary of primary system. The integrity of SG tube has been confirmed by the eddy current test every outage. In Korea, Bobbin probe and MRPC probe have been generally used for the eddy current test. Meanwhile the usage of Array probe has gradually increased in U.S., Japan and other countries. In this study, we investigated the defect detection capability of the Array probe through its preliminary application to SG tube inspection. The Array probe has the equivalent capability in the defect detection and sizing as the conventional methods. Thus it is desirable that the Array probe is generally applied to SG tube inspection in the domestic NPPs.

  • PDF

Effects of Breath and Exhaust on the Performance of a Reciprocating Engine for Small Aircraft (소형항공기용 왕복엔진의 성능에 관한 흡/배기 영향)

  • 김근배;김근택;최선우
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2002.10a
    • /
    • pp.37-40
    • /
    • 2002
  • The engine performance test was carried out to investigate the effects of breath and exhaust on the performance of a reciprocating engine for small aircraft. In this test, three valves to control flow areas of a inlet and two outlets were used, the engine manifold pressure and the static thrust of propeller were measured in nine breath/exhaust conditions. Generally, small variations on the performance were showed as the test conditions were changed. The manifold pressure was increased as flow area of the inlet or the outlet was decreased in normal condition, however it was decreased as both flow areas were decreased. The static thrust of propeller was showed similar as the manifold pressure.

  • PDF

The Effect of MgO Rate Preparing Conditions and Xe Partial Pressure on the Relative Life time of an AC Plasma Display Panel

  • Park, Cha-Soo;Park, Min-Seok;Park, Joon-Young;Kim, Dong-Hyun;Lee, Ho-Jun;Park, Chung-Hoo
    • KIEE International Transactions on Electrophysics and Applications
    • /
    • v.3C no.2
    • /
    • pp.35-42
    • /
    • 2003
  • This paper proposes a relative lifetime test method of MgO thin film. The suggested test conditions are 5$0^{\circ}C$, 400Torr, 20% over-voltage and 300KHz. The relative lifetime of MgO thin film is significantly affected by the MgO preparing conditions and Xe partial pressure. As result, the lifetime of the AC plasma display panel (PDP) is increased with an MgO thickness of 2000$\AA$ to 8000$\AA$ but is saturated over 5000$\AA$ (up to 9000 $\AA$). In addition, as Xe partial pressure increases, AC PDP lifetime increases.

A Study on Performance Change of Solid Rocket Motor for Variation of Nozzle Ambient Pressure (노즐 외기 압력 변화에 따른 고체추진기관 성능 변화 연구)

  • Kwon, Tae-Hoon;Rho, Tae-Ho;Cho, In-Hyun
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2007.11a
    • /
    • pp.219-222
    • /
    • 2007
  • This research on 2nd stage solid rocket motor of KSLV-I for performance change was carried out. Solid rocket motor shall ignite on altitude of 300km. Solid Rocket Motor performed Static Firing Test and High Altitude Test for motor performance. A study made an analysis of specific impulse variation for nozzle ambient pressure.

  • PDF