• Title/Summary/Keyword: Pressure Test

Search Result 7,926, Processing Time 0.037 seconds

The Effects of Music on Patients with Chronic Back Pain (만성요통 환자에게 미치는 음악의 적용 효과)

  • Lee, Jun-Woo
    • The Journal of Korean Physical Therapy
    • /
    • v.19 no.4
    • /
    • pp.53-64
    • /
    • 2007
  • Purpose: We investigated the effects of music on pain, blood pressure, and pulse in patients with chronic back pain. We tried to find some change of satisfaction of treatment and a sense. Method: We recruited total 30 patients with chronic back pain, who had pain from lumbago for more than six months. Subjects received electrotherapy and electrotherapy with music one at a time during me test, and subjects received one in the morning and the other one in the afternoon. We compared the test results between the electrotherapy and electrotherapy with music. Visual Analogue Scale was used to check the effect on pain. Blood pressure and pulse were checked, too. The gathered informatio was analyzed by t-test, independent sample t-test, and chi-square test. Results: There was statistically not significant difference between electrotherapy and electrotherapy with the music in VAS(Visual Analogue Scale)(p>0.05). There were statistically some significant differences between two groups in systolic pressure, diastolic pressure, and the pulse(p<0.05). Subject group showed statistically higher scores of satisfaction(p<0.05). There was significant difference between two groups(p<0.05) in the tingling and vibration sense. Conclusion: we found that the lumbago patients who are treated by electrotherapy with the music did not have additional difference in relief of pain, but electrotherapy with music can get better effects on their blood pressure, the pulse, satisfaction, and tingling-vibration sense. This means that the patients receive their treatment comfortably with rest. Therefore, We consider that it is desirable to play music to lumbago patients to offer the better treatment service to the patients.

  • PDF

The Effects of Carebidet Robot during Defecation on Incontinence Associated Dermatitis, Pressure Ulcer Risk, and Biological Markers in Critical Care Patients (케어비데로봇을 이용한 배설간호가 중환자실 환자의 실금관련피부염, 욕창위험도, 생리학적 지표에 미치는 효과)

  • Shin, Na Yeon;Kim, Tae Gon;Jang, Jin Young;Kim, Mi Yeon
    • Journal of Digital Convergence
    • /
    • v.19 no.12
    • /
    • pp.649-660
    • /
    • 2021
  • The purposes of this study were to examine the effects of carebidet robot during defecation on incontinence associated dermatitis, pressure ulcer risk and biological markers in critical care patients. Data were analyzed using t-test, Chi-square test, Fisher's exact test, Mann-Whitney U-test and Repeated measures ANOVA. There was a significant difference in incontinence associated dermatitis, pressure ulcer risk, and improving biological markers between the two groups, and there were significant changes over time and the group by time interactions. The findings of the study demonstrated that carebidet robot during defecation was more effective than the current usual care in reducing incontinence associated dermatitis, pressure ulcer risk, and improving biological markers in critical care patients.

Rocket Engine Test Facility Improvement for Hot firing test of a Combustor in the 30-tonf class (30톤급 연소기의 연소시험을 위한 설비 개량)

  • Lee Kwang-Jin;Seo Seonghyeon;Lim Byoungjik;Moon Il-Yoon;Han Yeoung-Min;Choi Hwan-Seok
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • v.y2005m4
    • /
    • pp.313-317
    • /
    • 2005
  • The facility improvement for hot firing test of combustion chamber having thrust of 30-tonf class and chamber pressure of 60bara were performed at ReTF in KARI. The KSR-III main engine having combustion pressure of 13bara and thrust of 12.5tonf had been successfully tested in this facility. To increase the capability of the facility, the feeding and the trust measurement system have been modified. The modification of the feeding system plays also a role of ensuring the stability of propellant supply and two step ignition sequence of combustion chamber. The one-axis thrust measurement system of up to 60tons has been newly manufactured and installed in test stand and the water/kerosene supply lines with high pressure vessel of $4m^3$ and gas nitrogen vessel of $10m^3$ have been designed for regenerative cooling system. The results of cold flow test show that this facility has been successfully improved to satisfy the requirement for hot firing test of high performance combustor.

  • PDF

A Study of Life Characteristics of Butterfly Valve Seated Rubber by Accelerated Life Test (고무시트 버터플라이밸브의 가속수명시험을 통한 수명특성 연구)

  • Lee, Gi-Chun;Lee, Young-Bum
    • The KSFM Journal of Fluid Machinery
    • /
    • v.16 no.5
    • /
    • pp.29-35
    • /
    • 2013
  • Butterfly valve seated rubber has been widely used in water works and industrial fields because it has advantages which are small installation area and low weight. The size and material of butterfly valve have been selected by service environments and purposes. But there are out of the ordinary to find papers for the life characteristics of the butterfly valve. So, this study carries out the accelerated life test, which has an acceleration factor with pressure, using performance and life test equipment. Accelerated model is adopted with 3 stress level and the inverse power law model to estimate the life of the test samples. After the analysis of the test result, accelerated index has 7.0 and the acceleration factor has 208 which is applied with field condition with the pressure 6.3 bar.

Thermal-Hydraulic Test Facilities and Some Test Results of Integrated Heating Reactors

  • Jia, Haijun;Wu, Shaorong;Jiang, Shengyao
    • Proceedings of the Korean Nuclear Society Conference
    • /
    • 1996.11a
    • /
    • pp.211-216
    • /
    • 1996
  • Since the middle of the eighties of this century a research program both for heating reactor and investigation of heating reactor thermal-hydraulics has been carried out in Institute of Nuclear Energy Technology(INET) of Tsinghua university in China. This kind of heating reactor is a light water cooled and integrated natural circulation reactor with low system pressure and low quality at the exit of core. Because of relatively long riser and low system pressure. a little change of the quality at the exit of the core will result in a relatively large variation of void fraction in the riser. Two full scale test loops. HRTL-5 and HRTL-200 simulating the HR-5 and HR-200 heating reactors in geometry and operation parameters respectively, and some test results from the HRTL-200 test facility are shown in this paper. The range of studied system pressure is from 1.0MPa to 4.0MPa, the largest heat flux is about 50 W/cm2, and the quality at the exit of test section is less than 5%.

  • PDF

VHCF Characteristics of A7075-T651 under Pressure Variation by Shot Peening Treatment (쇼트 피닝의 압력변화에 따른 A7075-T651재의 VHCF 피로특성)

  • Suh, Chang-Min;Kim, Cheol;Kim, Tae-Joon
    • Journal of Ocean Engineering and Technology
    • /
    • v.25 no.6
    • /
    • pp.72-79
    • /
    • 2011
  • In this paper, the fatigue characteristics of shot peened A7075-T651 alloy were compared with those of the specimens without the shot peening. The multi-spindle and single-spindle rotating bending fatigue testing machines were employed for the evaluation. Shot peening (SP) with various pressure (5 psi, 10 psi, 15 psi, 25 psi and 35 psi) were used in this test. In order to investigate the effect of the applied pressure during the SP, we carried out the surface roughness test, compressive residual stress test, hardness test, tensile test, VHCF (Very high cycle fatigue) test and SEM observation. SP induced the formation of remarkable compressive residual stress from the surface to certain depth of sample by means of the plastic deformation. The surface hardness and the fatigue characteristics of the specimens were also modified by the SP. According to the S-N curves, fatigue lives of shot peended sample with 25 psi measures 50 times higher than that of the untreated sample. The fatigue lives of shot peened sample with 15 psi and 35 psi measure approximately 10 times higher than that of the untreated ones.

Improving the Measurement Uncertainty of Altitude Test Facility for Gas Turbine Engines (가스터빈엔진 고공성능시험설비의 측정불확도 개선)

  • Lee, Dae-Sung;Yang, In-Young;Jun, Yong-Min;Kim, Chun-Taek;Yang, Soo-Seok
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.26 no.11
    • /
    • pp.1496-1502
    • /
    • 2002
  • An Altitude Engine Test Facility(AETF) was built at the Korea Aerospace Research Institute in October 1999 and has been being operated for altitude testing of gas turbine engines of 3,000 Ibf class or less. The AETF has been calibrated using several engines such as J69 of Teledyne Co. as a facility checkout engine. Uncertainty analyses on the air flow rate and thrust were performed using the test results, according to ASME PTC 19.1-1998. Several modifications on the facility and test method were made in order to improve the measurement uncertainty to a satisfactory level over the whole operating envelop. Spatial distributions of pressure and temperature were measured, sensors were substituted by more accurate ones, inlet duct was modified to refine the flow quality, and pressure control logic was revised to remove the cell pressure fluctuation. As a result, the uncertainty of the air flow measurement was improved by 0.1% over all the test conditions, and the net thrust measurement by up to 3%. The improved measurement uncertainties of air flow and thrust are 0.68~O.73% and 0.4~1.3%, respectively.

An Investigation into the effect of friction in the split hopkinson pressure bar (SHPB) test by numerical experiments (수치해석을 이용한 SHPB 시험의 마찰영향 분석)

  • Cha, Sung-Hoon;Shin, Myoung-Soo;Shin, Hyun-Ho;Kim, Jong-Bong
    • Proceedings of the KSME Conference
    • /
    • 2008.11a
    • /
    • pp.204-209
    • /
    • 2008
  • The interest in the mechanical behavior of materials at high strain rates has increased in recent years, and by now it is well known that mechanical properties can be strongly influenced by the speed of applied load. The split Hopkinson pressure bar (SHPB) has been widely used to determine mechanical properties of materials at high loading rates. However, to ensure test reliability, measurement error source must be accounted for and eliminated. During experiment, the specimens were located between the incident and the transmit bar. The presence of contact frictions between the test bars and specimen may cause errors. In this work, numerical experiments were carried out to investigate the effect of friction on test results. In SHPB test, the measured stress by the transmitted bar is assumed to be flow stress of the test specimen. Through the numerical experiments, however, it is shown that the measured stress by the transmit bar is axial stress components. When, the contact surface is frictionless, the flow stress and the axial stress of the specimen are about the same. When the contact surface is not frictionless, however, the flow stress and the axial stress are not the same anymore. Therefore, the measured stress by the transmitted bar is not flow stress. The effect of friction on the difference between flow stress and axial stress is investigated.

  • PDF

Development of 1/60th Scale Moving Model Rig Using the Compressed Air Launcher and One-Wire Guidance System of Train Model (압축공기 발사기에 단선 와이어 유도방식을 적용한 1/60축척 터널주행 열차모형 시험기 개발에 대한 연구)

  • Kim, Dong-Hyeon;O, Il-Geun
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.25 no.5
    • /
    • pp.634-644
    • /
    • 2001
  • The test facility of a 1/60-scale model for train-tunnel systems has been recently developed to investigate the effects of tunnel portal shapes, hood shapes and air-shafts for reducing the micro-pressure waves radiating towards the surroundings from the tunnel exit. The present test rig has been advanced from a 1/70-scale facility at NLR in Netherlands. The NLR test rig has the two-wise guidance system that needs two ears attached on the external surface of a model train nose. Therefore, their train models have irregular nose shapes. The main characteristics of the present facility are that the train model is guided by only one wire from the compressed air launcher to the absorber parts of test facility and the wire guidance hole is located at the axial center of a train model. In the present test rig, after a train model is launched, the air jet from the launcher does not enter the tunnel model. Experimental results were compared with numerical predictions to prove the performance of the test facility.

Effects of Each Characteristics on NOx Emission Values for Marine 4-Stroke Diesel Engine (선박용 디젤기관(4-Stroke)의 특정인자가 질소산화물에 미치는 영향 고찰)

  • Lee, J.W.;Kwon, O.S.;Kim, J.T.;Lee, B.W.
    • Proceedings of the Korean Society of Marine Engineers Conference
    • /
    • 2005.06a
    • /
    • pp.74-80
    • /
    • 2005
  • It becomes necessary for engine manufactures to verify whether lots of engines on test bed during shop test are in compliance with NOx Technical Code for marine diesel engines more efficiently on the basis of engine group test concept which contains parent engine and member engines since all the engines are not needed to take NOx measurement. In addition, it becomes more obliged to consider parameters which affect NOx emission level and describe these parameters in NOx technical file as engine information and settings to define engine operation range with tolerance to make sure the engines are still in compliance with NOx emission limit on board after shop test. During preparation of engine group test for 4-stroke marine diesel engines, we evaluated NOx emission value under different engine operating conditions and found that there are certain parameters, for example, Charge air temperature and Max. cylinder pressure which have influence on NOx emission level. The NOx emission shall be satisfied with NOx technical code by means of controlling such parameters.

  • PDF