• Title/Summary/Keyword: Pressure Swing Adsorption

Search Result 68, Processing Time 0.02 seconds

Pressure Swing Adsorption Based Hydrogen Purification Vessel 3D Modeling and Feasibility Study (Pressure Swing Adsorption 기반 수소정제용기 3차원 모델링 및 타당성 검증 연구)

  • CHA, YOHAN;CHOI, JAEYOO;JU, HYUNCHUL
    • Journal of Hydrogen and New Energy
    • /
    • v.32 no.4
    • /
    • pp.197-204
    • /
    • 2021
  • Pressure swing adsorption is a purification process which can get pure hydrogen. The purification process is composed of four process: compression, adsorption, desorption and discharge. In this study the adsorption process was simulated by using the Fluent and validated with experimental results. A gas used in experiment is composed of H2, CO2, CH4, and CO. Adsorption process conducted under 313 kelvin and 3 bar and bituminous-coal-based (BPL) activated carbon was used as the adsorbent. Langmuir model was applied to explain the gas adsorption. And diffusion of all the gases was controlled by micro-pore resistances. The result shows that, the most adsorbed gas was carbon dioxide, followed by methane and carbon monoxide. And carbon monoxide took the least amount of time to reach the maximum adsorption amount. The molar fraction of the off-gas became the same as the molar fraction of the gas supplied from the inlet after adsorption reached the equilibrium.

Separation of Oxygen from Air using Rapid Pressure Swing Adsorption (RPSA) Process (Rapid Pressure Swing Adsorption (RPSA) 공정을 이용한 공기에서의 산소 분리)

  • Choi, Jae-Wook;Lee, Hwa-Ung;Song, Hyung-Keun;Suh, Sung-Sup;Na, Byung-Ki
    • Clean Technology
    • /
    • v.14 no.1
    • /
    • pp.7-13
    • /
    • 2008
  • RPSA (Rapid Pressure Swing Adsorption) is a cyclic process which can be used to separate gas mixtures by adsorption method. Oxygen which is separated from air is used to the medical oxygen generator and biological wastewater treatment process. RPSA uses only one adsorption bed, so it is very simple to operate compared to conventional PSA process. In this work experimental parameters were examined with RPSA setup and parameters for the oxygen separation from air were obtained.

  • PDF

Adsorption/desorption of CO2 on Activated Carbon Fibers Using Electric Swing Adsorption (활성탄소섬유상에서 전기변동법을 이용한 CO2의 흡/탈착)

  • Shim, JaeWoon;Moon, SeungHyun
    • Korean Chemical Engineering Research
    • /
    • v.43 no.3
    • /
    • pp.432-437
    • /
    • 2005
  • An electric swing adsorption (ESA) process for recovering highly pure $CO_2$ from the mixed gases was tested. In this study, activated carbon fibers were used as an adsorbent. The activated carbon fibers showed fast adsorption rate and the high adsorption capacity for $CO_2$ adsorption under the condition of the ambient pressure. Activated carbon fiber with higher specific surface area was suitable to repeated adsorption-desorption cycle process, showing consistent breakthrough curve. Especially, the regeneration method by vacuum combined with ESA improved the performance of desorption process by an additional 17% regeneration efficiency compared to a vacuum only method, and showed the high regeneration efficiency at comparatively low 7-8 Wh energy.

Zeolites: Their Features as Pressure Swing Adsorbents and CO2 Adsorption Capacity (제올라이트: 압력순환형 흡착제로서의 특성과 CO2 흡착성능)

  • Kim, Moon-Hyeon;Cho, Il-Hum;Choi, Sang-Ok;Choo, Soo-Tae
    • Journal of Environmental Science International
    • /
    • v.23 no.5
    • /
    • pp.943-962
    • /
    • 2014
  • Industrial gas drying, dilute gas mixtures purification, air fractionation, hydrogen production from steam reformers and petroleum refinery off-gases, etc are conducted by using adsorptive separation technology. The pressure swing adsorption (PSA) has certain advantages over the other methods, such as absorption and membrane, that are a low energy requirement and cost-effectiveness. A key component of PSA systems is adsorbents that should be highly selective to a gas being separated from its mixture streams and have isotherms suitable for the operation principle. The six standard types of isotherms have been examined in this review, and among them the best behavior in the adsorption of $CO_2$ as a function of pressure was proposed in aspects of maximizing a working capacity upon excursion between adsorption and desorption cycles. Zeolites and molecular sieves are historically typical adsorbents for such PSA applications in gas and related industries, and their physicochemical features, e.g., framework, channel structure, pore size, Si-to-Al ratio (SAR), and specific surface area, are strongly associated with the extent of $CO_2$ adsorption at given conditions and those points have been extensively described with literature data. A great body of data of $CO_2$ adsorption on the nanoporous zeolitic materials have been collected according to pressure ranges adsorbed, and these isotherms have been discussed to get an insight into a better $CO_2$ adsorbent for PSA processes.

Hydrogen Separation from Multi-Component Mixture Gases by Pressure Swing Adsorption Process (PSA 공정을 이용한 다성분 혼합가스의 수소 분리)

  • Yang, Se-Il;Ahn, Eui-Sub;Jang, Seong-Cheol;Choi, Do-Young;Choi, Dae-Ki
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2006.11a
    • /
    • pp.447-450
    • /
    • 2006
  • Hydrogen separation from multi-component mixture gases by the four-bed PSA process was studied experimentally and theoretically using layered bed of activated carbon and zeolited 5A. Effects of the adsorption time, the linear velocity on the process performance were investigated. The adsorption time and linear velocity affected the purity and recovery of the product $H_2$ purity is increases according as the adsorption time and linear velocity decrease; however, $H_2$ recovery shows an opposite phenomena to the purity. PSA process simulation studied to find optimum operation condition. In the results, 50sec adsorption time, 3cm/s linear velocity might be optimal values to obtain more than 99.999% purity and 65% recovery hydrogen.

  • PDF

A Study on PSA Controll Strategy for Part Load Operation of a Hydrogen Generator (수소추출기의 부분부하 운전을 위한 PSA 제어전략에 대한 연구)

  • SANGHO LEE;SEONYEOB KIM;YOUNG CHOI
    • Journal of Hydrogen and New Energy
    • /
    • v.33 no.6
    • /
    • pp.819-826
    • /
    • 2022
  • Fuel cell systems are being supplied to households and buildings to reduce greenhouse gases. The fuel cell systems have problems of high cost and slow startup due to fuel processors. Greenhouse gas reduction of the fuel cell systems is also limited by using natural gas. The problems can be solved by using a hydrogen generator consisting of a reformer and pressure swing adsorption (PSA). However, part load operation of the hydrogen generator is required depending on the hydrogen consumption. In this paper, PSA operation strategies are investigated for part load of the hydrogen generator. Adsorption and purge time were changed in the range of part load ratio between from 0.5 to 1.0. As adsorption time increased, hydrogen recovery increased from 29.09% to 48.34% at 0.5 of part load ratio. Hydrogen recovery and hydrogen purity were also improved by increasing adsorption and purge time. However, hydrogen recovery dramatically decreased to 35.01% at 0.5 of part load ratio.

Practical Study of Low-temperature Vacuum Swing Adsorption Process for VOCs Removal (휘발성 유기화합물 제거를 위한 저온 vacuum swing adsorption 공정의 실용화 연구)

  • Jeon, Mi-Jin;Pak, Seo-Hyun;Lee, Hyung-Don;Jeon, Yong-Woo
    • Applied Chemistry for Engineering
    • /
    • v.28 no.3
    • /
    • pp.332-338
    • /
    • 2017
  • The objective of this work was to study the low temperature vacuum adsorption technology applicable to small and medium scale painting plants, which is the main emission source of volatile organic compounds. The low-temperature vacuum swing adsorption (VSA) technology is the way that the adsorbates are removed by reducing pressure at low temperature ($60{\sim}90^{\circ}C$) to compensate disadvantages of the existing thermal swing adsorption (TSA) technology. Commercial activated carbon was used and the absorption and desorption characteristics of toluene, a representative VOCs, were tested on a lab scale. Also based on the lab scale experimental results, a $30m^3min^{-1}$ VSA system was designed and applied to the actual painting factory to assess the applicability of the VSA system in the field. As a result of lab scale experiments, a 2 mm pellet type activated carbon showed higher toluene adsorption capacity than that of using 4 mm pellet type, and was used in a practical scale VSA system. Optimum conditions for desorption experiments were $80{\sim}90^{\circ}C$ and 100 torr. In the practical scale system, the adsorption/desorption cycles were repeated 95 times. As a result, VOCs discharged from the painting factory can be effectively removed upto 98% or more even after repeated adsorption/desorption cycles when using VSA technology indicating potential field applicabilities.

Separation of $CH_4/CO_2/N_2$ Mixture by Pressure Swing Adsorption (PSA법을 이용하여 $CH_4/CO_2/N_2$ 혼합가스 중에서 메탄의 분리)

  • Cho, Woo-Ram;Jeong, Gu-Hyun;Shin, Young-Hwan;Yoo, Hee-Chan;Na, Byung-Ki
    • Clean Technology
    • /
    • v.17 no.4
    • /
    • pp.389-394
    • /
    • 2011
  • A compact adsorption-based process for removal of carbon dioxide and nitrogen from natural gas has been discussed. Among the adsorption-based processes, especially, the pressure swing adsorption (PSA) process has been a suitable unit operation for the purification and separation of gas because of low operation energy and cost. A step cycle is made up of pressurization, feed, equalization, blowdown and rinse. In this work, the PSA process is composed of zeolite 13X and carbon molecular sieve (CMS) for removal of carbon dioxide and nitrogen from mixed gas containing $CH_4/CO_2/N_2$ (75:21:4 vol%). A CMS selectively removes carbon dioxide and a zeolite 13X separates nitrogen from methane. CMS is investigated experimentally due to the high throughput of the faster diffusing component ($CO_2$). The gas composition of top, bottom and feed tank was measured with the gas chromatography (GC) using TCD detector, helium as carrier gas and packed column for analysis of methane, carbon dioxide, and nitrogen.

Comparison of PSA and VSA processes for air separation (공기 분리를 위한 O2 PSA (Pressure Swing Adsorption)공정과 VSA (Vacuum Swing Adsorption) 공정의 설게 및 성능 비교)

  • Lee, Sang Jin;Ahn, Hyungwoong;Jee, Jeung-Geun;Kim, Min-Bae;Moon, Jong-Ho;Bae, Yoon-Sang;Lee, Chang-Ha
    • Clean Technology
    • /
    • v.10 no.2
    • /
    • pp.101-109
    • /
    • 2004
  • PSA and VSA processes have been used broadly to produce oxygen from ambient air in midium- or small-sized plants. PSA and VSA processes are the separation methods which use difference of amount adsorbed as pressure is changed periodically, but they have the differences in pressurization and regeneration. In this study, the performance of 6-step PSA process was compared with that of 5-step VSA process with respect to purity and recovery. In addition, the effects of each step (pressurization step, adsorption step, and pressure equalization step) on purity and recovery were investigated. As a result, the VSA process using zeolite 10X showed better performance than the zeolite 5A PSA and zeolite 13X VSA process in comparison with purity, recovery and productivity. And it was enough to apply the vacuum pressure of 200 torr for the VSA, which produced over 90% oxygen with 70% recovery.

  • PDF

Experimental Study on PSA Process for High Purity CH4 Recovery from Biogas (바이오가스로부터 고순도 CH4 회수를 위한 PSA 공정의 실험적 연구)

  • Kim, Young-Jun;Lee, Jong-Gyu;Lee, Jong-Yeon;Kang, Yong-Tae
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.23 no.4
    • /
    • pp.281-286
    • /
    • 2011
  • The objective of this study is to optimize the four-bed six-step pressure swing adsorption(PSA) process for high purity $CH_4$ recovery from the biogas. The effects of P/F(purge to feed) ratio and cycle time on the process performance were evaluated. The cyclic steady-states of PSA process were reached after 12 cycles. The purity and recovery rate of product gas, pressure and temperature changes were constant as the cycle repeated. It was shown that the P/F ratio gave significant effect on the product recovery rate by increasing the amount of purge gas in purge and regeneration step. The optimal P/F ratio was found to be 0.08. As the cycle time increased, the product purity decreased by increasing the feed gas flow rate. It was found that the optimal operating conditions were P/F ratio of 0.08 and total cycle time of 1,440 seconds with the purity of 97%.