• Title/Summary/Keyword: Pressure Signal

Search Result 911, Processing Time 0.026 seconds

A Study on Integrated Control and Safety Management Systems for LNG Membrane Storage Tank (멤브레인식 LNG 저장탱크용 통합제어안전관리시스템에 대한 연구)

  • Kim, Chung-Kyun
    • Journal of the Korean Institute of Gas
    • /
    • v.14 no.2
    • /
    • pp.40-46
    • /
    • 2010
  • In this study, the integrated control and safety management system for a super-large LNG membrane storage tank has been presented based on the investigation and analysis of measuring equipments and safety analysis system for a conventional LNG membrane storage tank. The integrated control and safety management system, which may increase a safety and efficiency of a super-large LNG membrane storage tank, added additional pressure gauges and new displacement/force sensors at the steel anchor between an inner tank and a prestressed concrete structure. The displacement and force sensors may provide clues of a membrane panel failure and a LNG leakage from the inner tank. The conventional leak sensor may not provide proper information on the membrane panel fracture even though LNG is leaked until the leak detector, which is placed at the insulation area behind an inner tank, send a warning signal. Thus, the new integrated control and safety management system is to collect and analyze the temperature, pressure, displacement, force and LNG density, which are related to the tank system safety and leakage control from the inner tank. The digital data are also measured from measurement systems such as displacement and force of a membrane panel safety, LNG level and density, cool-down process, leakage, and pressure controls.

Microcomputer Based Vacuum Drying System and its Application to the Vacuum Drying of Green Red Pepper (마이크로컴퓨터 감압건조(減壓乾燥)시스템의 제작운영(製作運營)과 풋고추의 감압건조특성(減壓乾燥特性))

  • Chun, Jae-Kun;Kang, Jun-Soo
    • Applied Biological Chemistry
    • /
    • v.30 no.1
    • /
    • pp.65-70
    • /
    • 1987
  • In Girder to measure the pressure and weight decrease of drying sample during the vacuum drying process of food, sensing devices were designed and constructed with strain gauge. Microcomputer based vacuum drying system was made up of these devices interfaced to apple II microcomputer. The electrical output signal from vacuum sensor which constituted with Bourdon tube whereon strain gauge attached were digitalized and input to microcomputer through the MC 6821 interface I.C. chip. The relationship between read-out digital value (D) from microcomputer and readings of vacuum gauge (P, mmHg) was P=-146.136+3.620D'(r=0.9994) The pressure control of vacuum dryer was successfully conducted in the range of $400{\sim}600\;mmHg$ accuracy. The digitalized load cell output (D) could be correlated with the real weight (W, g) as W=-14,000+0.585D (r=0.9998) Drying curves of green red pepper under $64^{\circ}C$, $400{\sim}600\;mmHg$ was similar to those of red pepper and differently affected by the degree of vacuum pressure but was varied according to their shape (cut or whole). Moisture movement of green red pepper during the vacuum drying process was fitted to Page model. The empirical equations obtained were $M-M_e/M_o-M_e={\exp}\;(-0.0673{\theta}^{1.177})$ and $M-M_e/M_o-M_e={\exp}\;(-0.0655\;{\theta}^{1.477})$ for whole and cut green red pepper, respectively.

  • PDF

Aerodynamic Study in Normal Korean and Patients with Vocal Polyp (정상인과 성대용종 환자에서의 공기역학적 검사)

  • 서장수;송시연;정유선;김정수;지덕환;이무경
    • Journal of the Korean Society of Laryngology, Phoniatrics and Logopedics
    • /
    • v.10 no.1
    • /
    • pp.5-11
    • /
    • 1999
  • Background and Objectives : Recently, many people suffering from voice change visit otolaryngologist. So, it is important to study vocal function in patients with glottic or laryngeal disease. Aerodynamic investigation is valuable information about the efficiency of the larynx in translating air pressure to acoustic signal. The purpose of this study was to investigate the aerodynamic data in patients with vocal polyp, compare this data with that of the normal Korean. Materials and Methods : In aerodynamic study, maximum phonation time, mean air flow rate, phonatory flow volume and subglottal pressure were tested by using Aerophone II voice function analyzer in 157 normal korean and 143 patients with vocal polyp, aged from 20 to 69 years randomly selected. Results and Conclusion : In vocal polyp, maximum phonation time was significantly decreased and mean air How rate was increased. Phonatory flow volume was significantly decreased and subglottic pressure was increased only in female with vocal polyp. These data will be served as basic data of evaluation after treatment and postoperative assessment of the patients with vocal polyp.

  • PDF

An Example of Test on Differences of Pulse Waveform Characteristics at Cun, Guan and Chi (촌, 관, 척 위치의 맥파 특징 차이 검정에 대한 1례)

  • Lee, Jeon;Lee, Yu-Jung;Jeon, Young-Ju;Lee, Hae-Jung;Ryu, Hyun-Hee;Kim, Jong-Yeol
    • Korean Journal of Oriental Medicine
    • /
    • v.14 no.2
    • /
    • pp.107-112
    • /
    • 2008
  • Although the pulse diagnosis position, Guan is apart from Cun or Chi by only $10{\sim}20$ mm at most, traditional medical doctors applies different indent pressures and even they states different pulse images are felt at Cun, Guan and Chi, To support their clinical behaviors, in this study, we tested statistically whether there are differences in pulse waveform measured at these three positions with SphygmoCor system used world widely, A 30 years old female subject without any evidence of cardiovascular diseases was involved in this experiment. Radial pulse waves were recorded at three different positions on left lower arm 10 times at three positions-Cun, Guan and Chi. With ANOVA, we tested whether, among three different positions. there are any differences in 12 parameters of radial pulse waveform and in estimated AIx(Augmentation Index) as an arterial stiffness index extracted from radial pulse waveform. As results, differences in optimal indent pressure h0 were observed at different measuring positions(P<0.001) but not significantly different. And pulse pressure his were found to be different(Chi$22.60{\pm}3.06%,\;18.60{\pm}3.37%\;and\;26.4{\pm}5.02%$ respectively. Consequently. AIx at Gwan seems to be lowest and that at Chi seems to be highest. So. we assert the AIx at Chi is likely to be overestimated. In further studies. we want to examine what make differences in these parameters between measuring positions. And it also seems to be worthy to investigate the relationship between the depth of radial artery and AIx. And, ultimately, we need to determine the best measuring process including measuring position, hold-down pressure, signal quality validation and so on. so to achieve the optimal waveform which represents subject's health condition for both western medicine and traditional medicine.

  • PDF

An Electromagnetic Shock Wave Generator Employing a Solenoid Coil for Extracorporeal Shock Wave Therapy: Construction and Acoustical Properties (체외 충격파 치료술을 위한 솔레노이드 코일을 이용한 전자기식 충격파 발생기: 구성 및 음향학적 특성)

  • Choi Min Joo;Lee Jong Soo;Kang Gwan Suk;Paeng Dong Guk;Lee Yoon Joon;Cho Chu Hyun;Rim Geun Hie
    • The Journal of the Acoustical Society of Korea
    • /
    • v.24 no.5
    • /
    • pp.271-281
    • /
    • 2005
  • An electromagnetic type shock wave generator suitable for extracorporeal shock wave therapy has been constructed by employing a solenoid coil. The Property of the shock waves produced by the shock wave generator was evaluated using a needle hydrophone. It was shown that, as the capacitor discharging voltage increased from 8 to 18 kV, the Positive Peak Pressure (P+) of the shock wave increased non-linearly from 10 to 77 Wa. In contrast. the negative peak Pressure (f) varied between -3.2 and -6.8 MPa. had its absolute maximum of -6.9 ma at 14 kV The peak amplitudes P+ measured repeatedly under the same voltage setting varied within $5\;\%$ from mean values and this is very small compared to about $50\;\%$ for electrohydraulic type shock wave generators. It could be observed, from the hydrophone signal recorded over 1 ms. several sequential acoustic impulses representing bubble collapses. namely. acoustic cavitation. induced by the shock wave. A technique based on wavelet transformation was used to accurately measure the time delay between the 1st and 2nd collapse known to be closely related to the shock strength. It was observed that the measured time delay increased almost linearly from 120 to $700\;{\mu}s$ with the shock wave Pressure P+ increasing from 10 to 77 MPa.

Genome-Wide Association Analyses on Blood Pressure Using Three Different Phenotype Definitions

  • Park, Ji-Wan;Uhmm, Saan-Yong;Shin, Chol;Cho, Nam-H.;Cho, Yoon-Shin;Lee, Jong-Young
    • Genomics & Informatics
    • /
    • v.8 no.3
    • /
    • pp.108-115
    • /
    • 2010
  • Hypertension is the most prevalent disease worldwide and is itself a risk factor for cerebral, cardiac, and renal diseases. The inconsistency of candidate genes suggested by previous genomewide association studies (GWASs) may be due to not only differences in study design and genetic or environmental background but also the difference in the power of analysis between continuous traits and discrete traits. We analyzed 352,228 single nucleotide polymorphisms (SNPs) in 8842 unrelated Koreans obtained from Ansan and Ansung cohorts. We performed a series of GWA analyses using three different phenotype models; young hypertensive cases (278 subjects) versus elderly normotensive controls (680 subjects); the upper 25% (2211 hypertensive cases) versus the lower 25% of the SBP distribution (2211 hypotensive controls); and finally SBP and DBP as continuous traits (8842 subjects). The numbers of young hypertensive cases and elderly normotensive controls were not large enough to achieve genomewide significance. The model comparing the upper 25% subjects to the lower 25% of subjects showed a power that was approximate to that of QTL analysis. Two neighboring SNPs of the ATP2B1 gene, rs17249754 (SBP, p=$2.53^{-10}$; DBP, p=$1.28{\times}10^{-8}$) and rs7136259 (SBP, p=$1.30{\times}10^{-9}$; DBP, p=$6.41{\times}10^{-8}$), were associated with both SBP and DBP. Interestingly, a SNP of the RPL6 gene, rs11066280, revealed a significant genomewide association with SBP in men only (p=$3.85{\times}10^{-8}$), and four SNPs located near the MAN2A1 gene showed a strong association with DBP only in elderly men aged 60-70 years (e.g., rs6421827, p=$4.86{\times}10^{-8}$). However, we did not observe any gene variant attaining genomewide significance consistently in the three phenotype models except for the ATP2B1 gene variants. In general, the association signal with blood pressure was stronger in women than in men. Genes identified in GWASs are expected to open the way for prevention, early diagnosis, and personalized treatment of hypertension.

Comparisons of Empirical Braking Models for Freight Trains Using P4a Distribution Valve (P4a 분배밸브를 사용하는 화물열차의 경험적 제동모델들의 비교)

  • Choi, Don Bum;Kim, Min-Soo;Lee, Kangmi;Kim, Young-Guk
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.21 no.1
    • /
    • pp.61-69
    • /
    • 2020
  • This study examined the braking characteristics of a heavy haul freight train with P4a distribution valves applied to domestic high-speed freight trains. A freight train was composed of 50 cars, which is twice the normal operation. A braking test was performed to confirm the characteristics of the braking of a heavy haul. The brake cylinder pressures were measured for emergency and service braking on the 1st, 10th, 20th, 30th, and 50th cars. Because the brake signal is transmitted to the pressure through the braking tube connected to the end of the train, the rear vehicle is braking later than the vehicle ahead. Therefore, it is necessary to predict the brake pressures in all cars in a train to supplement the results of the limited tests and calculate the braking distance. The pressure in each car was determined using empirical models of linear interpolation, stepwise, and exponential models, which provided reliable information. The predictive results of the empirical models were compared with the measured results, and the exponential model was predicted relatively accurately. These results are expected to contribute to the safe operation of heavy haul freight trains and can be used to predict the braking distance and calculate the level of impact between vehicles during braking.

The changes in signal-averaged electrocardiogram after surgical correction of congenital heart disease (선천성 심장병의 개심술 후 신호 평준화 심전도의 변화)

  • Kim, Yeo Hyang;Choe, Hee Jung;Kim, Gun Jik;Cho, Joon Yong;Hyun, Myung Chul;Lee, Sang Bum
    • Clinical and Experimental Pediatrics
    • /
    • v.52 no.12
    • /
    • pp.1364-1369
    • /
    • 2009
  • Purpose : To analyze abnormal ventricular activation in childhood congenital heart disease induced by postoperative changes in ventricular volume and pressure and ventricular scar formation using signal-averaged electrocardiography (SAECG). Methods : Fifty-two patients who had undergone open heart surgery (OHS) were enrolled. Patients were divided into the following 3 groups: right ventricular volume overload (atrial septal defect, group1), left ventricular volume overload (ventricular septal defect, group2), and right ventricular pressure overload (tetralogy of Fallot, group 3). The patients were monitored by standard 12-lead ECG and SAECG before and 2 months after the operation. QRS duration, QT and QTc intervals, filtered QRS (f-QRS), high frequency low amplitude potential (HFLA), and root mean square (RMS) voltage in the terminal 40 ms of SAECG were determined. Results : In the preoperative period, group1 showed significant increase in QRS (P=0.011) compared to those of the other 2 groups. In the postoperative period, group3 showed significant increase in the QTc interval (P=0.004) compared to those in the other 2 groups. SAECG parameters showed no significant differences among the groups in the pre- or postoperative period. Of the 52 patients, 12 (23%) in the preoperative period and 21 (40%) in the postoperative period had at least 1 SAECG abnormality. The prevalence of SAECG abnormalities was significantly higher in the postoperative group 2 and group 3 (preoperative: 20% versus postoperative: 28%, P<0.001, preoperative: 14% versus postoperative: 64%, P<0.001, respectively). Conclusion : Abnormal SAECG patterns may be attributed to postoperative scars, OHS itself, and/or ventricular overload.

Kinetic Investigation of CO2-CH4 Reaction over Ni/La2O3 Catalyst using Photoacoustic Spectroscopy

  • Oh, Hyun-Jin;Kang, Jin-Gyu;Heo, Eil;Lee, Sung-Han;Choi, Joong-Gill
    • Bulletin of the Korean Chemical Society
    • /
    • v.35 no.9
    • /
    • pp.2615-2620
    • /
    • 2014
  • Ni/$La_2O_3$ with a high dispersion was prepared by reduction of $La_2O_3$ perovskite oxide to examine the catalytic activity for the $CO_2-CH_4$ reaction. The Ni/$La_2O_3$ catalyst was found to be highly active for the reaction. The ratios of $H_2$/CO were measured in a flow of the reaction mixture containing $CO_2/CH_4$/Ar using an on-line gas chromatography system operated at 1 atm and found to be varied with temperature between 0.66 and 1 in the temperature range of $500-800^{\circ}C$. A kinetic study of the catalytic reaction was performed in a static reactor at 40 Torr total pressure of $CO_2/CH_4/N_2$ by using a photoacoustic spectroscopy technique. The $CO_2$ photoacoustic signal varying with the concentration of $CO_2$ during the catalytic reaction was recorded as a function of time. Rates of $CO_2$ disappearance in the temperature range of $550-700^{\circ}C$ were obtained from the changes in the $CO_2$ photoacoustic signal at early reaction stage. The plot of ln rate vs. 1/T showed linear lines below and above $610^{\circ}C$. Apparent activation energies were determined to be 10.4 kcal/mol in the temperature range of $550-610^{\circ}C$ and 14.6 kcal/mol in the temperature range of $610-700^{\circ}C$. From the initial rates measured at $640^{\circ}C$ under various partial pressures of $CO_2$ and $CH_4$, the reaction orders were determined to be 0.43 with respect to $CO_2$ and 0.33 with respect to $CH_4$. The kinetic results were compared with those reported previously and used to infer a reaction mechanism for the Ni/$La_2O_3$-catalyzed $CO_2-CH_4$ reaction.

Delamination Evaluation of Thermal Barrier Coating on Turbine Blade owing to Isothermal Degradation Using Ultrasonic C-scan Image (초음파 C-scan을 이용한 터빈 블레이드 열차폐코팅의 등온열화에 의한 박리 평가 기법)

  • Lee, Ho-Girl;Kim, Hak-Joon;Song, Sung-Jin;Seok, Chang-Sung
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.36 no.5
    • /
    • pp.353-362
    • /
    • 2016
  • Thermal barrier coating (TBC) is an essential element consisting of a super-alloy base and ceramic coating designed to achieve long operational time under a high temperature and pressure environment. However, the top coat of TBC can be delaminated at certain temperatures with long operation time. As the delamination of TBC is directly related to the blade damage, the coupling status of the TBC should be assured for reliable operation. Conventional studies of nondestructive evaluation have been made for detecting generation of thermally grown oxide (TGO) or qualitatively evaluating delamination in TBC. In this study, the ultrasonic C-scan method was developed to obtain the damage map inside TBC by estimating the delamination in a quantitative way. All specimens were isothermally degraded at $1,100^{\circ}C$ with different time, having different partial delamination area. To detect partial delamination in TBC, the C-scan was performed by a single transducer using pulse-echo method with normal incidence. Partial delamination coefficients of 1 mm to 6 mm were derived by the proportion of the surface reflection signal and flaw signal which were theoretical signals using Rogers-Van Buren and Kim's equations. Using the partial delamination coefficients, the partial delamination maps were obtained. Regardless of the partial delamination coefficient, partial delamination area was increased when degradation time was increased in TBC. In addition, a decrease in partial delamination area in each TBC specimen was observed when the partial delamination coefficient was increased. From the portion of the partial delamination maps, the criterion for delamination was derived.