• Title/Summary/Keyword: Pressure Signal

Search Result 910, Processing Time 0.033 seconds

Modification of acceleration signal to improve classification performance of valve defects in a linear compressor

  • Kim, Yeon-Woo;Jeong, Wei-Bong
    • Smart Structures and Systems
    • /
    • v.23 no.1
    • /
    • pp.71-79
    • /
    • 2019
  • In general, it may be advantageous to measure the pressure pulsation near a valve to detect a valve defect in a linear compressor. However, the acceleration signals are more advantageous for rapid classification in a mass-production line. This paper deals with the performance improvement of fault classification using only the compressor-shell acceleration signal based on the relation between the refrigerant pressure pulsation and the shell acceleration of the compressor. A transfer function was estimated experimentally to take into account the signal noise ratio between the pressure pulsation of the refrigerant in the suction pipe and the shell acceleration. The shell acceleration signal of the compressor was modified using this transfer function to improve the defect classification performance. The defect classification of the modified signal was evaluated in the acceleration signal in the frequency domain using Fisher's discriminant ratio (FDR). The defect classification method was validated by experimental data. By using the method presented, the classification of valve defects can be performed rapidly and efficiently during mass production.

Implementation of The Fluid Circulation Blood Pressure Simulator (유체 순환 혈압 시뮬레이터의 구현)

  • Kim, C.H.;Lee, K.W.;Nam, K.G.;Jeon, G.R.
    • Journal of Biomedical Engineering Research
    • /
    • v.28 no.6
    • /
    • pp.768-776
    • /
    • 2007
  • A new type of the fluid circulation blood pressure simulator was proposed to enhance the blood pressure simulator used for the development and evaluation of automatic sphygmomanometers. Various pressure waveform of fluid flowing in the pipe was reproduced by operating the proportional control valve after applying a pressure on the fluid in pressurized oil tank. After that, appropriate fluid was supplied by operating the proportional control valve, which enabled to reproduce various pressure wave of the fluid flowing in the tube. To accomplish this work, the mathematical model was carefully reviewed in cooperating with the proposed simulator. After modeling the driving signal as input signal and the pressure in internal tube as output signal, the simulation on system parameters such as internal volume, cross-section of orifice and supply pressure, which are sensitive to dynamic characteristic of system, was accomplished. System parameters affecting the dynamic characteristic were analyzed in the frequency bandwidth and also reflected to the design of the plant. The performance evaluator of fluid dynamic characteristic using proportional control signal was fabricated on the basis of obtained simulation result. An experimental apparatus was set-up and measurements on the dynamic characteristic, nonlinearity, and rising and falling response was carried out to verify the characteristic of the fluid dynamic model. Controller was designed and thereafter, simulation was performed to control the output signal with respect to the reference input in the fluid dynamic model using the proposed proportional control valve. Hybrid controller combined with an proportional controller and feed-forward controller was fabricated after applying a disturbance observer to the control plant. Comparison of the simulations between the conventional proportional controller and the proposed hybrid simulator indicated that even though the former showed good control performance.

Accuracy Validation of Urinary Flowmetry Technique Based on Pressure Measurement (수압 측정에 기반하는 요류검사의 정확도 검증)

  • Choi, Sung-Soo;Lee, In-Kwang;Kim, Kun-Jin;Kang, Seung-Bum;Park, Kyung-Soon;Lee, Tae-Soo;Cha, Eun-Jong;Kim, Kyung-Ah
    • Journal of Biomedical Engineering Research
    • /
    • v.29 no.3
    • /
    • pp.198-204
    • /
    • 2008
  • Uroflowmetry is a non-invasive clinical test useful for screening benign prostatic hyperplasia(BPH) common in the aged men. The current standard way to obtain the urinary flow rate is to continuously acquire the urine weight signal proportional to volume over time. The present study proposed an alternative technique measuring pressure to overcome noise problems present in the standard weight measuring technique. Experiments were performed to simultaneously acquire both weight and pressure changes during urination of 9 normal men. Noise components were separated from volume signals converted from both weight and pressure signals based on the polynomial signal model. Signal-to-noise ratio was defined as the ratio of the energies between signal and noise components of the measured volume changes, which was 8.5 times larger in the pressure measuring technique, implying that cleaner signal could be obtained, more immune to noisy environments. When four important diagnostic parameters were estimated, excellent correlation coefficients higher than 0.99 were resulted with mean relative errors less than 5%. Therefore, the present pressure measurement seemed valid as an alternative technique for uroflowmetry.

Pressure Monitoring System in Gastro-Intestinal Tract

  • Kim, Byung-Kyu;Kim, Yong-In;Park, Suk-Ho;Jo, Jin-Ho;Park, Gwi-Tae
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2005.06a
    • /
    • pp.196-201
    • /
    • 2005
  • Diseases in the gastro-intestinal tract are on an increasing trend. In order to diagnose a patient, various signals of the digestive organ, such as temperature, pH, and pressure, can offer the helpful information. Among the above mentioned signals, we choose the pressure variation as a monitoring signal. The variation of a pressure signal of the gastro-intestinal tract can offer the information of a digestive trouble or some clues of the diseases. In this paper, a pressure monitoring system for the digestive organs of a living pig is presented. This is why a pig's gastro-intestinal tract is very similar as human's. This system concept is to transmit the measured biomedical signals from a transmitter in a living pig to a wireless receiver that is positioned out of body. The integrated solution includes the swallow type pressure capsule and the receiving set consisting of a receiver, decoder circuit. The merit of the proposed system is that the monitoring system can supply the precise and a durable characteristic to measure and to transmit a signal in the gastro-intestinal tract. We achieved the pressure tracings in digestive organs and verified the validity of system after several in-vivo tests using the pressure monitoring system. Through various experiments, we found each organ has its own characterized pressure fluctuation.

  • PDF

Measurements of Saturation Energy Denity and Small Signal Gain Coefficient Dependent on the Active Gas Pressure in XeCl Laser Amplifier (XeCl 레이저 증폭기의 활성기체 압력에 따른 포화 에너지 밀도와 소신호 이득계수 측정)

  • 김규옥;김용평
    • Korean Journal of Optics and Photonics
    • /
    • v.5 no.4
    • /
    • pp.457-460
    • /
    • 1994
  • Dependence of saturation energy density and small signal gain coefficient on the active gas pressure in XeCl laser amplifier has been investigated. The saturation energy density was increased almost linearly as 1.3, 1.45, 2.0, and $2.3mJ/\textrm{cm}^2$ when the pressure of Xe and He were 30 and 2000 mb, and the pressure of HC] was varied as 34, 52, 73, and 92 mb. Whereas the small signal gain coefficient was measured to be 6.5, 7.5, 7.0, 7.0 %/cm, which shows that the small signal gain did not varies not so much.o much.

  • PDF

Pressure Control Characteristics of a 2-Way Solenoid Valve Driven by PWM Signal (2방향 전자밸브의 PWM 신호에 의한 압력제어 특성)

  • Jeong, Heon-Sul;Kim, Hyoung-Eui
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.26 no.8
    • /
    • pp.1565-1576
    • /
    • 2002
  • By way of driving a 2-way on/off solenoid hydraulic valve with a pulse width modulation (PWM) signal, control of the pressure in a certain volume is frequently used in various applications. However, the pressure built-up according to the duty ratio and carrier frequency of the PWM signal is not so well understood. In order to clarify the characteristics of 2-way valve hydraulic pressure control systems, in this paper two formula fur the mean and ripple of the load pressure were derived through theoretical analysis. And the accuracy of the derived formula were verified by comparison with the experimental test result. Generally 2-way valve systems are constructed as a bleed-off circuit, while 3-way valves are used as a control element in a meter-in circuit pressure control system. In a bleed-off circuit, the system supply pressure from a hydraulic power pack does not remain constant, but changes according to their external load. In turn, the relief valve in the hydraulic power pack reacts accordingly showing complicated dynamic behavior, which makes an analytical study difficult. In order to resolve the problem, simple but accurate empirical dynamic models fer a bleed-off system were used in the course of formula derivation. As the result, selection criteria for two major control parameters of the driving signal is established and the basic strategy to suppress the unnecessary pressure fluctuation can be provided for a hydraulic pressure control system using a 2-way on/off solenoid valve.

Development of the Emulator on Propulsion System (추진시스템 신호모사장비 개발)

  • Chung, Soon-Bae;Kim, Jung-Hoi;Park, Kon-Kuk;Kim, Young-Sam
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2008.11a
    • /
    • pp.431-432
    • /
    • 2008
  • In order to develop and inspect the electronic controller of propulsion system, It must emulate the electronic signal similar to actual signal. The applied signals on propulsion system are engine speed, turbine speed, various kinds of temperatue signal, pressure signal, LVDT/RVDT position signal and so forth. Contents are the development of emulator that simulate the electronic signals similar to actual signals.

  • PDF

Design and characteristics of a fiber-optic pressure sensor (광압력 센서의 설계 및 특성)

  • Kim, Young-Soo;Kim, Yo-Hee;Strigalev, V. E.
    • Proceedings of the KIEE Conference
    • /
    • 1995.11a
    • /
    • pp.508-510
    • /
    • 1995
  • A fiber-optic pressure sensor is fabricated with a photoelastic glass material. To remove the influence of external pertubation along the optical fiber, a new referencing technique is proposed by using two light sources. LED with 870nm wavelength is used as light source for reference signal, and LED with 660nm wavelength is used as light source for modulation signal. The fiber-optic pressure sensor system shows good linearity within the pressure range of 0 to 5 $kg/cm^2$.

  • PDF

A Study on the Pressure Control Characteristics of ON/OFF 3-way Solenoid Valve Driven by PWM Signal (개폐식 3방향 전자밸브의 펄스폭 변조 구동에 의한 압력제어 특성에 관한 연구)

  • Jeong, Heon-Sul
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.21 no.3
    • /
    • pp.485-501
    • /
    • 1997
  • Pressure control is possible driving a simple ON/OFF 3-way valve of hydraulic servo system by pulse width modulation signal. But the pressure varies according to the duty ratio and carrier frequency and repeated on-off action induces pressure fluctuation. So equations for mean pressure and ripple amplitude are theoretically derived as a function of on/off time, the system parameters which decide the pressure characteristics are arranged and they are verified by experimental study. As the result selection criteria for the major design parameters are established and the basic strategy to suppress the unnecessary fluctuation can be provided for a hydraulic pressure control system using these type of valves.

Development of a Pressure Measurement System with the Parallel Structure (병렬구조의 압력측정 시스템 개발)

  • Yun, Eui-Jung;Kim, Jwa-Yeon;Lee, Kang-Won;Lee, Seok-Tae
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.19 no.4
    • /
    • pp.328-333
    • /
    • 2006
  • In this paper, we developed a pressure measurement apparatus with the parallel structure to improve the measurement efficiency of pressure sensors by reducing the measurement time of pressure. The developed system has two parallel positions for loading Silicon pressure sensor and has a dual valve structure. The semiconductor pressure sensors prepared by Copal Electronics were used to confirm the performance of the developed measurement system. Two stage differential amplifier circuit was employed to amplify the weak output signal and the amplified output signal was improved utilizing a low-pass filter. New apparatus shows the measurement time of pressure two times shorter than that of conventional one with the serial structure, while both structures show the similar linear output versus pressure characteristics.