• Title/Summary/Keyword: Pressure Sensor Control

Search Result 323, Processing Time 0.028 seconds

Establishment of CTD Calibration System and Uncertainty Estimation (CTD 교정 시스템 구축 및 불확도 평가)

  • Lee, Jung-Han;Hwang, Keun-Choon;Kim, Eun-Soo;Lee, Seung-Hun
    • Ocean and Polar Research
    • /
    • v.36 no.1
    • /
    • pp.77-85
    • /
    • 2014
  • The quality control of ocean observations data is becoming a major issue as real-time observational data and information services have increased recently. Therefore, it is necessary for oceanographic instruments to calibrate. In this paper, we first introduce the CTD calibration system and traceability. Next, CTD calibration procedures and estimation of uncertainty of measurement are described. The expanded uncertainty (k = 2) of the temperature, pressure and conductivity are 0.$0.003^{\circ}C$, $6.0{\times}10^{-5}$ and 0.006 mS/cm respectively. Finally, the excellence of CTD calibration and its measurement capability has been proven by comparing the inter-calibration result of KIOST and Sea-Bird Electronics (SBE). CTD calibration residuals are less than ${\pm}0.0001^{\circ}C$, ${\pm}0.001$ MPa, ${\pm}0.0001$ S/m for SBE 3plus temperature sensor, SBE 19plus pressure sensor and SBE 4C conductivity sensor respectively.

Design of Irrigation Pumping System Controller for Operational Instrument of Articulation (관절경 수술을 위한 관주(灌注)시스 (Irrigation Pumping System) 제어기의 개발)

  • 김민수;이순걸
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2003.06a
    • /
    • pp.1294-1297
    • /
    • 2003
  • With the development of medical field, many kinds of operations have been performed on human articulation. Arthroscopic surgery, which has Irrigation Pumping System for security of operator vision and washing spaces of operation, has been used for more merits than others. In this paper, it is presented that the research on a reliable control algorithm of the pumping system instrument for arthroscopic surgery. Before clinical operation, the flexible artificial articulation model is used for realizing the model the most same as human's and the algorithm has been exploited for it. This system is considered of the following; limited sensing point, dynamic effect by compliance, time delay by fluid flow and so on. The system is composed with a pressure controller, a regulator for keeping air pressure, an airtight tank that can have distilled water packs, artificial articulation and a measuring system, and has controlled by the feedback of pressure sensor on the artificial articulation. Also the system has applied to Smith Predictor for time delay and the parameter estimation method for the most suitable system with both the experiment data and modeling. In this paper, the pressure error that is between an air pressure tank and an artificial articulation was measured so that the system could be presumed and then the controller had developed for performing State-Feedback. Finally, the controller with a real microprocessor has realized. The confidence of system can be proved by applying this control algorithm to an artificial articulation experiment material.

  • PDF

Formation of Silicon Diaphragm Using Silicon-wafer Direct Bonding / Electrochemical Etch-stopping and Its Application to Silicon Pressure Sensor Fabrication (실리콘 직접 접합 / 전기화학적 식각정지를 이용한 실리콘 다이아프램의 형성과 실리콘 압력센서 제조에의 응용)

  • Ju, B.K.;Ha, B.J.;Kim, K.S.;Song, M.H.;Kim, S.H.;Kim, C.J.;Tchah, K.H.;Oh, M.H.
    • Journal of Sensor Science and Technology
    • /
    • v.3 no.3
    • /
    • pp.45-53
    • /
    • 1994
  • A new type of Si diaphragm was fabricated using Si-wafer direct bonding and two-step electrochemical etch-stopping methods. Using the new diaphragm structure in mechanical sensors, more precise control of cavity depth and diaphragm thickness was achievable. Also, the propagation of the stress, which was generated near the bonding interface, to the surface can be avoided. Finally, a piezoresistive-type Si pressure sensor was fabricated utilizing the diaphragm and a digital pressure gauge, which can display units of pressure, was realized.

  • PDF

Relationship between atrial pressures and the interventricular pressure in the moving actuator type total artificial heart (심실간 공간 압력을 이용한 이동작동기형 완전이식 인공심장에서의 좌, 우심방압 추정)

  • Jo, Y.H.;Choi, W.W.;Park, S.K.;Choi, J.S.;Lee, J.J.;Om, K.S.;Kim, H.C.;Min, B.G.
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1996 no.05
    • /
    • pp.88-90
    • /
    • 1996
  • The right and left atrial pressures are important parameters in automatic control of a total artificial heart (TAH) within normal physiological ranges. Our TAH is composed of a moving actuator, right and left ventricles and the interventricular space enclosed by a semi-rigid housing. During operation of the TAH, the jnterventpicular space's volume is changed dynamically by the difference between the ejection volume of one ventricle and the inflow volume of the other. Therefore, the changes in pressure of the interventricular space is related to both atrial pressures. We measured the interventricular pressure (IVP) waveform using a pressure sensor and attempted to indirectly estimate the changes of atrial pressures. This method has an advantage that the sensor does not contact the blood directly. Furthermore, the IVP waveforms have its zero baseline in each pump cycle, thus the pressure measurements are free from the transducer drift problems by measuring the peak pressure from these baseline values. From the In vitro experiments, we found that the IVP waveform contained several useful parameters such as negative peak, dP/dT on the initial break, the area enclosed by the profile in each stroke, which are associated with atrial pressures and the filling conditions of the ventricles. The measured atrial pressures were linearly related to the negative peak of the interventricular pressure.

  • PDF

A Study of Deflection of Ceramic Diaphragm for a Pressure Sensor (압력센서를 위한 ceramic diaphragm의 변위에 관한 고찰)

  • Lee, Seong-Jae;Min, Nam-Ki
    • Proceedings of the KIEE Conference
    • /
    • 2000.07c
    • /
    • pp.1655-1657
    • /
    • 2000
  • 본 논문에서는 세라믹 다이어프램식 압력센서를 설계하기 전에 세라믹 다이어프램의 변위에 대한 최적 조건을 확립하기 위해 세라믹의 기계적 특성, 다이어프램의 두께와 직경 등을 변화시키면서 중심부와 변곡점 부근에서 압력에 대한 다이어프램의 변위를 시뮬레이션 하였다.

  • PDF

Development of an Measuring System for Pulse Wave Corresponding to Different Radial Artery Diameters Caused by Indentation (요골동맥 직경 변화에 따른 맥파 측정 시스템 개발)

  • Lee, Jeon;Woo, Young-Jae;Jeon, Young-Ju;Lee, Yu-Jung;Kim, Jong-Yeol
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.57 no.12
    • /
    • pp.2351-2357
    • /
    • 2008
  • Noninvasive radial artery pulse wave has been widely used not only for the pulse wave analysis(PWA) itself but also for assessment of arterial stiffness with estimated aortic pulse wave from peripheral pulse wave. However, it has been found that the deformation of pulse shape can be caused readily by changing measuring position, indentation pressure, and so on. So, in this study, we have developed a system which can measure radial pulse wave and skin displacement simultaneously while the indentation body goes down to occlude subject's radial artery. This system can be divided into a measuring apparatus part, an indentation control hardware part, a data acquisition part and a control and computation part. And, the measuring apparatus consists of an arm-rest, a step motor, an indentation body, a laser displacement sensor(LK-G30, Keyence Co.) and pulse wave sensor. Under load-free condition and radial artery loaded condition, the evaluation of developed system has been performed. From these results, we can conclude: 1) The developed system can control the indentation body quantitatively and the adopted laser displacement sensor shows linear output characteristic even with skin as a reflector. 2) This system can measure the pulse wave and the displacement of indentation body, that is, skin displacement simultaneously at each specific level of indentation body. 3) This system can provide the number of motor steps used to get down the indentation body, the measured skin displacement, the calculated indentation pressure, the calculated pulse pressure and the pulse waveform as well as the information generated by combining these with each others. 4) This system can reveal the relationship between the morphological changes of pulse wave and the estimated displacement of radial artery wall by indentation. Consequently, the developed system can furnish more abundant information on radial artery than previous diagnosis systems based on tonometric measurement. In further study, we expect to setup the standard measuring process and to concrete the algorithm for the estimation of radial artery's diameter and of displacement of radial artery's wall. Furthermore, with well designed clinical studies, we hope to turn out the usefulness of developed system in the field of cardiovascular system evaluation.

Output Characteristic of a Flexible Tactile Sensor Manufactured by 3D Printing Technique (3D 프린팅 방법으로 제작된 유연 촉각센서의 출력 특성 분석)

  • Jin, Seung Ho;Lee, Ju Kyoung;Lee, Suk;Lee, Kyung Chang
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.31 no.2
    • /
    • pp.149-156
    • /
    • 2014
  • Flexible tactile sensors can provide valuable feedback to intelligent robots about the environment. This is especially important when the robots, e.g., service robots, are sharing the workspace with human. This paper presents a flexible tactile sensor that was manufactured by direct writing technique, which is one of 3D printing method with multi-walled carbon nano-tubes. The signal processing system consists of two parts: analog circuits to amplify and filter the sensor output and digital signal processing algorithms to reduce undesired noise. Finally, experimental setup is implemented and evaluated to identify the characteristics of the flexible tactile sensor system. This paper showed that this type of sensors can detect the initiation and termination of contacts with appropriate signal processing.

Model Based Fault Detection for Advanced ESC System (지능형 ESC 시스템을 위한 모델 기반 결함검출)

  • Kim, Byeong-Woo;Hur, Jin
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.59 no.12
    • /
    • pp.2306-2313
    • /
    • 2010
  • This paper describes a model based fault detection algorithm for an Advanced ESC System which consists of Hydraulic Control Unit (HCU) with built-in wheel pressure sensors. Advanced ESC System can be used for various value-added functions such as Stop & Go Function and Regenerative Brake Function. Therefore, HCU must have a reliable fault detection. Due to the huge amount of sensor signals, existing specific sensor based fault detection of HCU cannot guarantee the safety of vehicle. However, proposed algorithm dose not require the sensors. When model based fault detection algorithm detects severe failures of the HCU, it warns the driver in advance to prevent accidents due to the failures. For this purpose, a mathematical model is developed and validated in comparison to actual data. Simulation results and data acquired from an actual system are compared with each other to obtain the information needed for the fault detection process.

Development of Smart AQS for Commercial Vehicle for Satisfying Agreeable Environment (쾌적 환경을 위한 상용차용 스마트 AQS 개발)

  • Kim, Man-Ho;Lee, Dong-Hyun;Lee, Suk;Lee, Kyung-Chang
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.14 no.5
    • /
    • pp.496-501
    • /
    • 2008
  • Recently, many automotive companies tend to apply an air quality system (AQS), which prevents polluted air such as smoke or dust by controlling air intake actuator of vehicle, to satisfy the consumer's need for agreeable in-vehicle environment. However, performance of the traditional AQS is not satisfactory because a polluted air may enter into the inside of vehicle through the breaks of windows. Especially, the commercial vehicles such as bus or truck need to be prevented polluted air from the breaks of vehicle. Hence, as an alternative to the traditional AQS, this paper presents the architecture of smart AQS for commercial vehicle and implementation of the smart AQS. Also, the performance of the suggested system is evaluated through an experimental testbed.

A Study on the Improved EDR Storage Data to Identify the Cause of Unintended Acceleration of Eco-friendly Vehicles (친환경 자동차의 급발진 원인 규명을 위한 EDR 저장 데이터 개선방안 연구)

  • Lee, Sang Bae;Kim, Dong Han;Moon, Byoung Joon
    • Journal of Auto-vehicle Safety Association
    • /
    • v.14 no.3
    • /
    • pp.17-22
    • /
    • 2022
  • In this paper, we propose the improved EDR (Event Data Recorder) storage data, which can identify the cause of unintended acceleration of eco-friendly vehicles. The proposed EDR storage data includes the brake pressure sensor value and a brake pedal travel sensor value. To verify the proposed EDR storage data, we observe the control algorithm and internal structure of the vehicle dynamic control system and a regenerative braking system in an eco-friendly vehicle.