• Title/Summary/Keyword: Pressure Pulse

Search Result 1,219, Processing Time 0.027 seconds

Study on Effect of Varience of Physiological Responses in Color Foot Reflexology Using Color Light (컬러광을 활용한 발반사요법이 인체 생리적 반응 변화에 미치는 영향에 관한 연구)

  • Jin, Hye-Ryeon;Yu, Mi;Park, Kyung-Jun;Kim, Nam-Gyun;Chung, Sung-Whan;Kim, Dong-Wook
    • Science of Emotion and Sensibility
    • /
    • v.13 no.1
    • /
    • pp.187-196
    • /
    • 2010
  • Recently, people have been suffering from stress-related fatigue and psychological disorders. Most people depend on medicine for pain relief; many treat pain also through alternative medicine or replacement therapy. However, drug therapy has many side effects, including increased stress after the therapy. In comparison, alternative therapies such as massage and foot reflexology are less damaging to the body, and such therapies can be provided without physical or psychological discomfort. In this regard, the author had previously co-developed color foot reflexology, which combines the merits of color therapy and foot reflexology; color foot reflexology has been shown to have beneficial effects without undue pain. This study investigates the effects of color foot reflexology on the physiological response of the body by comparing the body’s response to the signal with that to the placebo. Healthy adult subjects were selected for the experiment, which was conducted under optimal experimental conditions and design. The results indicated that when stimulated, parasympathetic nerves increased in HRV and that blood pressure, pulse, body heat, peripheral blood flow were dramatically activated. However, the results for the placebo indicated minimal changes or irregular outcomes. The results provide strong evidence for the beneficial effects of the color foot reflexology instrument on the autonomic nervous system and on the physiological response of the body. Future research is warranted to verify the results of the current study by examining patients suffering from diseases and disorders arising from irregular physiological functions in the context of the foot.

  • PDF

Excessive Daytime Sleepiness Case Confounding with Thyrotoxicosis (과도한 주간 졸림과 탈력발작을 주소로 내원한 환자에서 발견된 갑상선 중독증)

  • Chung, Jae-Kyung;Kim, Eui-Joong
    • Sleep Medicine and Psychophysiology
    • /
    • v.18 no.1
    • /
    • pp.40-44
    • /
    • 2011
  • Narcolepsy is a sleep disorder, which is characterized by excessive daytime sleepiness (EDS) that is typically associated with cataplexy, sleep fragmentation and other REM sleep-related phenomenon such as sleep paralysis and hypnagogic hallucination. Narcoleptic symptoms can be developed from various medical or neurological disorders. A 17-year-old male patient admitted for the evaluation of EDS which started three-month ago. He slept more than 18 hours a day with cataplexy and hypnagogic hallucination. He was obese with body mass index (BMI) of 30.4 kg/$m^2$. After admission he was newly diagnosed to the thyrotoxicosis. T3 391.2 ng/dL (60-181), free T4 4.38 ng/dL (0.89-1.76), TSH <0.01 ${\mu}IU$/mL (0.35-5.5) were measured. His pulse rate ranged 70-90 beats per minute and blood pressure ranged 150/100-120/70 mmHg. Polysomnography revealed many fragmentations in sleep with many positional changes (81 times/h). Sleep onset latency was 33.5 min, sleep efficiency was 47.9%, and REM latency from sleep onset was delayed to 153.6 min. REM sleep percent was increased to 27.1%. Periodic limb movement index was 13.4/h. In the multiple sleep latency test (MSLT), average sleep latency was 0.4 min and there were noted 3 SOREMPs (Sleep Onset REM sleep period) on 5 trials. We couldn't discriminate the obvious sleep-wake pattern in the actigraph and his HLA DQB1 $^*0602$ type was negative. His thyroid function improved following treatment with methimazole and propranolol. Vital sign maintained within normal range. Cataplexy was controlled with venlafaxine 75 mg. Subjective night sleep continuity and PLMS were improved with clonazepam 0.5 mg, but the EDS were partially improved with modafinil 200-400 mg. Thyrotoxicosis might give confounding role when we were evaluating the EDS, though sleep fragmentation was one of the major symptoms of narcolepsy, but enormous amount of it made us think of the influence of thyroid hormone. The loss of sleep-wake cycle, limited improvement of EDS to the stimulant treatmen, and the cataplexy not supported by HLA DQB1 $^*0602$ should be answered further. We still should rule out idiopathic hypersomnia and measuring CSF hypocretin level would be helpful.

Safety and efficacy of the ultra-rush immunotherapy with extracts of Dermatophagoides pteronyssinus in children (집먼지 진드기 항원을 이용한 초급속면역치료의 안전성과 효과)

  • Hyun, Sei Eun;Kim, Hyoung Yun;Kwak, Ji Hee;Shin, Youn Ho;Seo, Ji Yeong;Han, Man Yong
    • Clinical and Experimental Pediatrics
    • /
    • v.51 no.8
    • /
    • pp.868-873
    • /
    • 2008
  • Purpose : Immunotherapy is accepted as the only treatment of allergic disease that can modify the natural course of the disease and ameliorate symptoms. This study aimed to evaluate the safety and efficacy of ultra-rush therapy using Dermatophagoides extracts in children. Methods : Of children older than four years who had visited Bundang CHA Pediatric Allergy Clinic, those showing positive reactions only to Dermatophagoides in the skin prick test and to the nasal provocation test were included. In all, 11 and 12 patients respectively preferred conventional and ultra-rush immunotherapy. We elevated allergen concentrations diluted to 1,000:1 of the end strength by 2-3 times with 30-minute intervals and checked oxygen saturation, pulse rate, blood pressure, and systemic reactions every 15 minutes. Immunotherapy effectiveness was valued by changes in nasal provocation test scores before and after immunotherapy. Results : The average ages of patients in the conventional and ultra-rush immunotherapy groups were $8.3{\pm}2.3$ and $9.2{\pm}2.8years$, respectively. Systemic reactions were observed in six in the ultra-rush group (50%) without anaphylaxis and one (9%) in the conventional group. The average scores in the nasal provocation test before and after treatment in the conventional group were $8.2{\pm}1.5$ and $4.6{\pm}2.1$, respectively (P=0.043). In the ultra-rush immunotherapy group, the scores changed from $6.2{\pm}2.2$ to $3.7{\pm}2.5$ (P=0.017). Conclusion : Ultra-rush immunotherapy using Dermatophagoides in children is effective for treating allergic disease but can induce systemic effects rather than conventional immunotherapy.

Carbon nanotube field emission display

  • Chil, Won-Bong;Kim, Jong-Min
    • Electrical & Electronic Materials
    • /
    • v.12 no.7
    • /
    • pp.7-11
    • /
    • 1999
  • Fully sealed field emission display in size of 4.5 inch has been fabricated using single-wall carbon nanotubes-organic vehicle com-posite. The fabricated display were fully scalable at low temperature below 415$^{\circ}C$ and CNTs were vertically aligned using paste squeeze and surface rubbing techniques. The turn-on fields of 1V/${\mu}{\textrm}{m}$ and field emis-sion current of 1.5mA at 3V/${\mu}{\textrm}{m}$ (J=90${\mu}{\textrm}{m}$/$\textrm{cm}^2$)were observed. Brightness of 1800cd/$m^2$ at 3.7V/${\mu}{\textrm}{m}$ was observed on the entire area of 4.5-inch panel from the green phosphor-ITO glass. The fluctuation of the current was found to be about 7% over a 4.5-inch cath-ode area. This reliable result enables us to produce large area full-color flat panel dis-play in the near future. Carbon nanotubes (CNTs) have attracted much attention because of their unique elec-trical properties and their potential applica-tions [1, 2]. Large aspect ratio of CNTs together with high chemical stability. ther-mal conductivity, and high mechanical strength are advantageous for applications to the field emitter [3]. Several results have been reported on the field emissions from multi-walled nanotubes (MWNTs) and single-walled nanotubes (SWNTs) grown from arc discharge [4, 5]. De Heer et al. have reported the field emission from nan-otubes aligned by the suspension-filtering method. This approach is too difficult to be fully adopted in integration process. Recently, there have been efforts to make applications to field emission devices using nanotubes. Saito et al. demonstrated a car-bon nanotube-based lamp, which was oper-ated at high voltage (10KV) [8]. Aproto-type diode structure was tested by the size of 100mm $\times$ 10mm in vacuum chamber [9]. the difficulties arise from the arrangement of vertically aligned nanotubes after the growth. Recently vertically aligned carbon nanotubes have been synthesized using plasma-enhanced chemical vapor deposition(CVD) [6, 7]. Yet, control of a large area synthesis is still not easily accessible with such approaches. Here we report integra-tion processes of fully sealed 4.5-inch CNT-field emission displays (FEDs). Low turn-on voltage with high brightness, and stabili-ty clearly demonstrate the potential applica-bility of carbon nanotubes to full color dis-plays in near future. For flat panel display in a large area, car-bon nanotubes-based field emitters were fabricated by using nanotubes-organic vehi-cles. The purified SWNTs, which were syn-thesized by dc arc discharge, were dispersed in iso propyl alcohol, and then mixed with on organic binder. The paste of well-dis-persed carbon nanotubes was squeezed onto the metal-patterned sodalime glass throuhg the metal mesh of 20${\mu}{\textrm}{m}$ in size and subse-quently heat-treated in order to remove the organic binder. The insulating spacers in thickness of 200${\mu}{\textrm}{m}$ are inserted between the lower and upper glasses. The Y\ulcornerO\ulcornerS:Eu, ZnS:Cu, Al, and ZnS:Ag, Cl, phosphors are electrically deposited on the upper glass for red, green, and blue colors, respectively. The typical sizes of each phosphor are 2~3 micron. The assembled structure was sealed in an atmosphere of highly purified Ar gas by means of a glass frit. The display plate was evacuated down to the pressure level of 1$\times$10\ulcorner Torr. Three non-evaporable getters of Ti-Zr-V-Fe were activated during the final heat-exhausting procedure. Finally, the active area of 4.5-inch panel with fully sealed carbon nanotubes was pro-duced. Emission currents were character-ized by the DC-mode and pulse-modulating mode at the voltage up to 800 volts. The brightness of field emission was measured by the Luminance calorimeter (BM-7, Topcon).

  • PDF

The development of conductive 10B thin film for neutron monitoring (중성자 모니터링을 위한 전도성 10B 박막 개발)

  • Lim, Chang Hwy;Kim, Jongyul;Lee, Suhyun;Jung, Yongju;Choi, Young-Hyun;Baek, Cheol-Ha;Moon, Myung-Kook
    • Journal of Radiation Protection and Research
    • /
    • v.39 no.4
    • /
    • pp.199-205
    • /
    • 2014
  • In the field of neutron detections, $^3He$ gas, the so-called "the gold standard," is the most widely used material for neutron detections because of its high efficiency in neutron capturing. However, from variable causes since early 2009, $^3He$ is being depleted, which has maintained an upward pressure on its cost. For this reason, the demands for $^3He$ replacements are rising sharply. Research into neutron converting materials, which has not been used well due to a neutron detection efficiency lower than the efficiency of $^3He$, although it can be chosen for use in a neutron detector, has been highlighted again. $^{10}B$, which is one of the $^3He$ replacements, such as $BF_3$, $^6Li$, $^{10}B$, $Gd_2O_2S$, is being researched by various detector development groups owing to a number of advantages such as easy gamma-ray discrimination, non-toxicity, low cost, etc. One of the possible techniques for the detection is an indirect neutron detection method measuring secondary radiation generated by interactions between neutrons and $^{10}B$. Because of the mean free path of alpha particle from interactions that are very short in a solid material, the thickness of $^{10}B$ should be thin. Therefore, to increase the neutron detection efficiency, it is important to make a $^{10}B$ thin film. In this study, we fabricated a $^{10}B$ thin film that is about 60 um in thickness for neutron detection using well-known technology for the manufacturing of a thin electrode for use in lithium ion batteries. In addition, by performing simple physical tests on the conductivity, dispersion, adhesion, and flexibility, we confirmed that the physical characteristics of the fabricated $^{10}B$ thin film are good. Using the fabricated $^{10}B$ thin film, we made a proportional counter for neutron monitoring and measured the neutron pulse height spectrum at a neutron facility at KAERI. Furthermore, we calculated using the Monte Carlo simulation the change of neutron detection efficiency according to the number of thin film layers. In conclusion, we suggest a fabrication method of a $^{10}B$ thin film using the technology used in making a thin electrode of lithium ion batteries and made the $^{10}B$ thin film for neutron detection using suggested method.

Effect of Noise in Human Body (소음이 인체에 미치는 영향)

  • 이영노
    • Proceedings of the KOR-BRONCHOESO Conference
    • /
    • 1972.03a
    • /
    • pp.7-8
    • /
    • 1972
  • The effects of noise exposure are of two types: Nonauditory effects and auditory effects. Nonauditory effects of noise exposure are interference with communication by speech, sleeping and emotional behavior. The noise will cause the high blood pressure and rapid pulse, also that decrease the salivation and gastric juice. in experimentaly showed that the Corticoid hormon: Gonatotropic hormone were decrease and Thyrotropic hormoone is increase. Auditory effect of noise exposure. when the normal ear is exposed to noise at noise at hamful intensities (above 90㏈) for sufficiently long periods of time, a temoral depression of hearing results, disappearing after minutes or hours of rest. When the exposure longer or intesity greater is reached the Permanent threshold shift called noise-induced hearing loss. Hearing loss resulting from noise exposure presents legal as well as medical problems. The otologist who examines and evaluates the industrial hearing loss cases must be properly informed, not only concerning the otologic but also about the physical and legal aspects of the problems. The measurement of hearing ability is the most important part of a hearing conservation, both preplacement and periodic follow-up tests of hearing. The ideal hearing conservation program would be able to reduce or eliminate the hazardous noise at its source or by acoustic isolation of noisy working area and two ear protections (plugs and muff type) were developed for personal protection.

  • PDF

The Respiratory and Hemodynamic Effects of Prone Position According to the Level of PEEP in a Dog Acute Lung Injury Model (잡종견 급성폐손상 모델에서 Prone position 시행시 PEEP 수준에 따른 호흡 및 혈류역학적 효과)

  • Lim, Chae-Man;Chin, Jae-Yong;Koh, Youn-Suck;Shim, Tae-Sun;Lee, Sang-Do;Kim, Woo-Sung;Kim, Dong-Soon;Kim, Won-Dong
    • Tuberculosis and Respiratory Diseases
    • /
    • v.45 no.1
    • /
    • pp.140-152
    • /
    • 1998
  • Background: Prone position improves oxygenation in patients with ARDS probably by reducing shunt Reduction of shunt in prone position is thought to be effected by lowering of the critical opening pressure (COP) of the dorsal lung because the pleural pressure becomes less positive in prone position compared to supine position. It can then be assumed that prone position would bring about greater improvement in oxygenation when PEEP applied in supine position is just beneath COP than when PEEP is above COP. Hemodynamically, prone position is expected to attenuate the lifting of cardiac fossa induced by PEEP. Based on these backgrounds, we investigated whether the effect of prone position on oxygenation differs in magnitude according to the level of PEEP applied in supine position, and whether impaired cardiac output in supine position by PEEP can be restored in prone position. Methods: In seven mongrel dogs, $PaO_2/F_1O_2$(P/F) was measured in supine position and at prone position 30 min. Cardiac output (CO), stroke volume (SV), pulse rate (PR), and pulmonary artery occlusion pressure (PAOP) were measured in supine position, at prone position 5 min, and at prone position 30 min. After ARDS was established with warmed saline lavage(P/F ratio $134{\pm}72$ mm Hg), inflection point was measured by constant flow method($6.6{\pm}1.4cm$ $H_2O$), and the above variables were measured in supine and prone positions under the application of Low PEEP($5.0{\pm}1.2cm$ $H_2O$), and Optimal PEEP($9.0{\pm}1.2cm$ $H_2O$)(2 cm $H_2O$ below and above the inflection point, respectively) consecutively. Results : P/F ratio in supine position was $195{\pm}112$ mm Hg at Low PEEP and $466{\pm}63$ mm Hg at Optimal PEEP(p=0.003). Net increase of P/F ratio at prone position 30 min, however, was far greater at Low PEEP($205{\pm}90$ mm Hg) than at Optimal PEEP($33{\pm}33$ mm Hg)(p=0.009). Compared to CO in supine position at Optimal PEEP($2.4{\pm}0.5$ L/min), CO in prone improved to $3.4{\pm}0.6$ L/min at prone position 5 min (p=0.0180) and $3.6{\pm}0.7$ L/min at prone position 30 min (p=0.0180). Improvement in CO was attributable to the increase in SV: $14{\pm}2$ ml in supine position, $20{\pm}2$ ml at prone position 5 min (p=0.0180), and $21{\pm}2$ ml at prone position 30 min (p=0.0180), but not to change in PR or PAOP. When the dogs were turned to supine position again, MAP ($92{\pm}23$ mm Hg, p=0.009), CO ($2.4{\pm}0.5$ L/min, p=0.0277) and SV ($14{\pm}1$ ml, p=0.0277) were all decreased compared to prone position 30 min. Conclusion: Prone position in a dog with saline-lavaged acute lung injury appeared to augment the effect of relatively low PEEP on oxygenation, and also attenuate the adverse hemodynamic effect of relatively high PEEP. These findings suggest that a PEEP lower than Optimal PEEP can be adopted in prone position to achieve the goal of alveolar recruitment in ARDS avoiding the hemodynamic complications of a higher PEEP at the same time.

  • PDF

Variation of Vital Sign according to Time in Full Immersion of Hot and Cool Bath (온.냉욕 전신침수욕시 기간에 따른 vital sign의 변화)

  • Yi, Seung-Ju
    • Journal of Korean Physical Therapy Science
    • /
    • v.3 no.3
    • /
    • pp.35-49
    • /
    • 1996
  • This study was conducted to see variation of vital sign of hot and cool bath according to time, a questionnair survey and measurement was carried out for 32 students(sophomore) of department of physical therapy Andong Junior College on the 27th of June, 1995. The result were as follows: The average systolic blood pressure(SBP) of stability for 32 college students who were measured was 105.3mmHg, the average diastolic blood pressure(DBP) was 67.3mmHg, the average pulse frequency(PF) was 70.7(frequency/min), the average respiratory frequency (RF) was 15.6 (frequency/min), and the body temperature(BT) was $36.6^{\circ}C$. As time went on, SBP for 32 students who were measured in hot bath according to stability, 3 min, 6 min, 9 min, and 12 min was decreased(105.15 mmHg, 104.69mmHg, 104.24 mmHg, 103.03 mmHg, and 96.69 mmHg)(P=0.3006). SBP was decreased in cool bath, too(105.15 mmHg, 103.33 mmHg, 103.33 mmHg, and 100.91 mmHg), but it at 12 min was a little higher(l03.09 mmHg)(P=0.7566). As time went on, DBP according to stability, 3 min, 6 min, 9 min, and 12 minutes was decreased in hot bath(66.82 mmHg, 65.45 mmHg, 64.54 mmHg, 63.03 mmHg, and 59.39 mmHg)(P=0.0906). It was similar in cool bath(66.82 mmHg, 67.87 mmHg, 68.48 mmHg, 67.87 mmHg, and 68.78)(P=0.9654). As time went on, PF was significantly increased in hot bath(70.42 times, 86.96 times, 93.57 times, 99.30 times, and 101.78 times)(P=0.0001). It was a little increased in cool bath, too (70.42 times, 70.85 times, 71.63 times, 71.06 times, and 71.45 times)(P=0.9803). As time went on, RF was significantly increased in hot bath(15.75 times, 19.09 times, 22.09 times, 24.94 times, and 26.48 times)(P=0.0001). I t in cool bath of stability, 3 min, and 6 min was a little increased(15.75 times, 19.30 times, 19.39 times), but it in 9 min(18.67 times), and 12 min(18.09 times) was a little decreased(P=0.0176). As time went on, BT was significantly increased in hot bath($36.63^{\circ}C,\;37.45^{\circ}C,\;37.81^{\circ}C,\;38.12^{\circ}C,\;38.33^{\circ}C$)(P=0.0001). It was a little increased in cool bath of stability and 3 min($36.63^{\circ}C,\;37.40^{\circ}C$), but others are similar($37.33^{\circ}C,\;37.37^{\circ}C$, and $37.36^{\circ}C$)(P=0.0001). It was revealed by this study, SBP and DBP according to time in hot and cool bath were decreased. PF, RF, and BT in hot bath were higher, RF and BT in cool bath were higher too. but PF was similar.

  • PDF

Effects of Percutaneous Balloon Mitral Valvuloplasty on Static Lung Function and Exercise Performance (승모판협착증 환자에서 경피적 풍선확장판막성형술의 폐기능 및 운동부하 검사에 대한 효과)

  • Kim, Yong-Tae;Kim, Woo-Sung;Lim, Chae-Man;Chin, Jae-Yong;Koh, Youn-Suck;Kim, Jae-Joong;Park, Seong-Wook;Park, Seung-Jung;Lee, Jong-Koo;Kim, Won-Dong
    • Tuberculosis and Respiratory Diseases
    • /
    • v.41 no.1
    • /
    • pp.1-10
    • /
    • 1994
  • Background: Patients with mitral stenosis(MS) have been demonstrated to have a variable degree of pulmonary dysfunction and exercise impairment. The hemodynamic changes of MS can be reversed after percutaneous mitral balloon valvuloplasty(PMV), but the extent and time course of the imporvement in pulmonary function and exercise capacity are not defined. Methods: In order to investigate the early(3 weeks or less)and late(3 months or more) effects of PMV on pulmonary function and determine if the pulmonary dysfunction is reversible even in patients with moderate to severe pulmonary hypertension, we performed the spirometry, measurements of diffusing capacity and lung volumes, and incremental exercise tests in patients with MS before and after PMV. Results: In 46 patients with MS(age: $40{\pm}12$years, male to female ratio: 1:2, mitral valve area: $0.8{\pm}0.2cm^2$) there was a significant increase in FVC(P<0.0025), $FEV_1$(P<0.001), $FEF_{25-75%}$(P<0.001, $FEF_{50%}$(P<0.001), PEF(P<0.0005), MVV(P<0.005), $\dot{V}O_2$max (P<0.0001), and AT(P<0.0001) after average 10 days of PMV. Also there was a significant decrease in DLco(P<0.0001) and DL/VA(P<0.0001). At later($5{\pm}2$months) follow-up in 11 patients, there was no further improvement in any parameters of pulmonary function and exercise test. Twenty nine patients with sinus rhythm were divided into 16 patients with pulmonary arterial pressure(PAP) more than 35mmHg and/or tricuspid regurgitation grade n or more(group A) and 13 patients with PAP less than 35mmHg(group B). Group A Patients had significantly lower FVC(P<0.001), $FEV_1$(P<0.001), DLco(P<0.05), $\dot{V}O_2$ max(P<0.025) and mitral valve area(P<0.025) than group B patients. Group A patients after PMV, showed significant increase in FVC(P<0.001), maximum $O_2$ pulse(P<0.00001) and $\dot{V}O_2$ max(P<0.00025). Both group showed an increase in AT(P<0.0001, P<0.005), but group A showed greater decrease in $\dot{V}E/\dot{V}O_2$ and $\dot{V}E/\dot{V}CO_2$ both at AT(P<0.001, P<0.001) and $\dot{V}O_2$ max(P<0.0001, P<0.0001) after PMV compared with group B. Conclusion: These data suggest that patients with MS can show increased pulmonary function and exercise performance within 1 month after PMV. Patients with moderate to severe pulmonary hypertension had a significant increase in exercise performance compared with those with mild to no pulmonary hypertension and it is thought to be related to a significat decrease of ventilation for a given oxygen consumption at maximum exercise.

  • PDF