• 제목/요약/키워드: Pressure Measuring System

검색결과 486건 처리시간 0.035초

커프 압력 조절에 따른 혈류량 변화 평가를 위한 임피던스법의 구현 (Implementation of Impedance Method to Estimate Blood Flow Variation with Cuff Pressure Change)

  • 정도운;배진우;손정만;예수영;최병철;남기곤;김철한;전계록
    • 센서학회지
    • /
    • 제13권6호
    • /
    • pp.462-472
    • /
    • 2004
  • In this study, we measured the blood flow on arm by non-invasive method and implemented a system to measure variation of the blood flow by estimating bio-electrical impedance and arterial pressure according to cuff pressure. The implemented system measured impedance variation according to pressure variation applied by artificial cuff pressure on the measuring position. The system consisted of pressure measuring part and impedance measuring part using 4-electrode method. Pressure measuring part was composed of semiconductor pressure sensor and electronic circuit for signal processing of sensor output signal. In addition, impedance measuring part was composed of constant current source circuit and lock-in amplifier for detecting impedance signal. We conducted experiments of impedance measuring part using standard resistance for performance evaluation of the implemented system. In addition we experimented to estimate variation of the blood flow by measuring impedances of the experimental group. We estimated ratio of the blood flow resistance using mean arterial pressure and variation of the blood flow. As a result the ratio of the blood flow resistance and variation of blood flow were in an inverse relationship with each other and the correlation coefficient was -0.96776.

스마트폰을 이용한 실시간 혈압측정 시스템의 설계 및 구현 (Design and Implementation of Real-time Blood Pressure Measuring System using Smartphone)

  • 길영준;이정태
    • 정보과학회 컴퓨팅의 실제 논문지
    • /
    • 제21권3호
    • /
    • pp.192-214
    • /
    • 2015
  • ECG, PTT 및 $SpO_2$와 같은 생체신호를 이용하여 실시간으로 혈압을 측정하고, IPv4/IPv6프로토콜을 이용하여 인터넷에 접속할 수 있는 시스템을 설계하고 구현하였다. 아울러 임상 실험을 통해 실시간 환경에서 수축기 혈압과 이완기 혈압을 계산할 수 있는 모델을 제시하였다. 이렇게 구현된 실시간 혈압측정 시스템을 28명의 피험자를 대상으로 임상 실험을 실시한 결과, 영국 고혈압협회(BHS)에서 인증하는 혈압계 인증 등급 Grade B 수준에서 정상으로 동작함을 확인하였다.

연체압측정기를 이용한 연체 사이의 압력 측정 (Measurement of the pressure between elastic bodies and between an elastic and a rigid body using elastic-body pressure meter)

  • 김운회;박경수
    • 대한인간공학회지
    • /
    • 제8권2호
    • /
    • pp.43-47
    • /
    • 1989
  • An instrumentation system to measure the pressure between elastic bodies and between an elastic and a rigid body has been developed. The force between elastic bodies can be measured only by Elastric- body pressure Meter. As a standard Elastic-body pressure Meter, Model RCG-24A consists of 24 pick-ups, one switch box and one amplifier and measuring is possible at each of 24 measuring spots by swithing one to the nest using the switch box. The system can be used in various specialized disciplines, such as ergonomics, anthropometry and biomechanics.

  • PDF

레이져 절단에서 노즐이 미치는 영향

  • 이호준;김재도
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 1992년도 추계학술대회 논문집
    • /
    • pp.81-85
    • /
    • 1992
  • Quality of cut is strongly dependent on the cutting pressure, so this relationship can be identified by pressure measuring system. In this paper, the experiments presented were performed with the devised pressure measuring system and the laser cutting of STS 304. Convergent type and convergent-divergent type nozzle were used for pressure variation of the distance between nozzle and workpiece. In laser cutting of STS 304, 1.0 kW CO $\_$2/ laser used. The convergent type nozzle(1.0 mm diameter) pressured above 3 kgf/cm $\^$2/, the MSD(Mach Shock Disk) created, which caused the the pressure variations of the distance between nozzle and workpiece. The maximum cutting pressure exists in accordance with the variation of distance. In spite of far distance the maximum cutting pressure is achieved by using the pressure measuring system. The higher cutting pressure beneath the workpiece the less quantity of dross and the kerf width. Since the higher cutting pressure helps to remove the quantity of dross and to stop the exothermic energy into the material. The optimum laser cutting parameter of STS 304(2.0 mm thickness) with the convergent type nozzle(1.0 mm diameter)is 0.75 mm and 2.5 mm distance between nozzle and workpiece, 4 kgf/cm $\^$2/ cutting pressure. In 3.0 mm thickness case, 1.5 mm and 2.25 mm distance is achieved for good quality.

맥진 깊이 판단을 위한 실시간 압력 측정기 (Real-Time Pressure-Measuring System for Evaluating the Depth of Pulse)

  • 조정호;김대복;김기왕
    • 동의생리병리학회지
    • /
    • 제27권3호
    • /
    • pp.313-317
    • /
    • 2013
  • In order to standardize the pressure/depth against radial artery, the externally-applied-pressure measuring system was fabricated and evaluated. Based on the resistance-variable characteristic of the very thin($10{\mu}m$) film conductive tape along the pressure of a tip of a examiner's hand, this system was designed. The change of the pressure was processed through voltage regulator and Matlab S/W, then showed on computer monitor. The signal output through voltage regulator, and Matlab S/W was evaluated on various conditions. The evaluation was executed on these cases; an examiner slowly increases and decreases the pressure, rapidly increases and decreases the pressure, sequentially increases and decreases the pressure, sustains the pressure, micro-changes the pressure. As a pulse examiner varies the pressure on the radial artery of the examinee, the system's real-time output consistently varies according to the pressure. From the results, it is concluded that this system consistently shows the pressure of the tip of a examiner's hand in real time without interrupting the evaluation of the radial artery pulse. Therefore this system is expected to standardize the value of the pressure/depth externally applied by an examiner.

릴럭턴스를 이용한 Reluctive Pressure Transducer의 설계 (The Design using the reluctance of Reluctive Pressure Transducer)

  • 조항신;박희성;주형준;성세진;이기홍
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 1998년도 전력전자학술대회 논문집
    • /
    • pp.328-331
    • /
    • 1998
  • Because of the powerful tolerance of overload, dynamic response and anti-erosion, Reluctive Pressure Transducer(RPT), as a measuring element of oil pressure equipment is applied to the measuring system of vessels, air craft. The Electrical reluctance appeared in the pressed diaphragm. To process the reluctance as a electric signal, bridge circuit is used. The design using the reluctance of pressure sensor is described in this paper. For the high efficiency of the sensitive RPT, pressure sensor structure is presented and electrical signal processing is simulated.

  • PDF

압력분포 측정용 시스템 개발 및 응용 (Development and Application of System for Pressure Distribution Measurement)

  • 김용환;박성하
    • 한국자동차공학회논문집
    • /
    • 제11권6호
    • /
    • pp.134-140
    • /
    • 2003
  • The film sensor is used for measuring pressure distribution at planar area, especially at a small space or gap. The present paper deals with the development of film type sensors and system for pressure distribution measuring. The developed system is consist of (1)film sensor with 40/sup */40 array, (2)PCI interface card with maximum sampling rate of 100㎐, and (3)software for data processing and real-time display. The contact pressure test of wiper blade and front glass of vehicle was performed with wiper blade by 40cm. Generally spring force of wiper arm is designed at 0.7∼1kN. Test results of total force was 9.4N and 7.1N in each driver and passenger toward. The paper suggested possibility for base definition in wiper design. A windshield wiper blade experiment revealed that the system successfully measured the contact force distribution during static state, showing the usefulness of the developed system.

STS304의 레이저 절단에서 보조가스 압력이 미치는 영향 (Effect of Assistant Gas Pressure on Laser Cutting of STS304)

  • 이호준;조용무;유웅재;김재도
    • 한국정밀공학회지
    • /
    • 제12권3호
    • /
    • pp.15-22
    • /
    • 1995
  • This paper presents the effects of assistant gas pressure on laser cutting. To investigate the effects of assistant gas pressure, pressure measuring system was constructed with good handling and precision at low price. The measured results discussed compare with that of laser cutting of STS304. The assistant gas pressure varied with the variation of distance between nozzle and workpiece. The peak pressure existed at some distance and could be known by using the deviced pressure measuring system. The higher assistant gas pressure helps to remove the dross and the exothermic energy out of the material. The quantity of dross beneath the workpiece decreases and the kerf width narrows at measured peak pressure.

  • PDF

욕창 방지를 위한 체압 모니터링 시스템 개발 (Development of The Physical Pressure Monitoring System to Prevent Pressure Ulcers)

  • 이아라;장경배
    • 대한임베디드공학회논문지
    • /
    • 제6권4호
    • /
    • pp.209-214
    • /
    • 2011
  • This study suggests a Healthcare System for elderly and disabled who have mobility impairment and use a wheelchair for long time. Seating long time in a wheelchair without reducing pressure causes high risk of developing pressure sores. Pressure sores come with great deal of pain and often lead to develop complication. Not only it takes time and effort to treat pressure sores but also increases medical expenses. Therefore, we will develop a device to help to prevent pressure sores by measuring pressure distribution while seating in a wheelchair and wirelessly send information to user device to check pressure distribution in real time. The equipment to measure body pressure is composed of FSR sitting mat which is a sensor measuring part and an user terminal which is a monitoring part. The designed mat is matrix formed FSR sensor to measure pressure. The sensor send measured data to the controller which is connected to the end of the mat, and then the collected data are sent to an user terminal through a bluetooth. Developing a pressure monitoring system will help to prevent those who have mobility impairment to manage pressure sores and furthermore relieve their burden of medical expenses.