• Title/Summary/Keyword: Pressure Loss Factor

Search Result 192, Processing Time 0.023 seconds

Assessment of CFD Estimation Capability for the Local Loss Coefficients of Sudden Contraction and Expansion (급격 확대 및 축소관의 압력손실계수에 대한 전산유체역학 해석의 예측성능 평가)

  • Kim, Hyun-Jung;Park, Jong-Pil
    • Applied Chemistry for Engineering
    • /
    • v.21 no.3
    • /
    • pp.258-264
    • /
    • 2010
  • Most of fluid systems, such as P&ID in ships, power plants, and chemical plants, consist of various components. The components such as bends, tees, sudden-expansions, sudden-contractions, and orifices contribute to overall pressure loss of the system. The local pressure losses across such components are determined using a pressure loss coefficient, k-factor, in lumped parameter models. In many engineering problems Idelchik's k-factor models have been used to estimate them. The present work compares the k-factor based on CFD calculation against Idelchik's model in order to confirm whether a commercial CFD package can be used for pressure loss coefficient estimation of complex geometries. The results show that RSM is the best appropriate for evaluating pressure loss coefficient. Commercial CFD package can be used as a tool evaluating k-factor even though the accuracy is influenced by a turbulence model.

EXPERIMENTAL STUDY ON THE HEAVY-DUTY GAS TURBINE COMBUSTOR (산업용 가스터빈 연소기에 대한 실험적 연구)

  • Antonovsky, V.;Ahn, Kook-Young
    • Proceedings of the KSME Conference
    • /
    • 2000.11b
    • /
    • pp.142-149
    • /
    • 2000
  • The results of stand and field testing of a combustion chamber for a heavy-duty 150 MW gas turbine are discussed. The model represented one of 14 identical segments of a tubular multican combustor constructed in the scale 1:1. The model experiments were executed at a pressure smaller than in the real gas turbine. The combustion efficiency, pressure loss factor, pattern factor, liner wall temperature, flame radiation, fluctuating pressure, and NOx emission were measured at partial and full load for both model and on-site testing. The comparison of these items of information, received on similar modes in the stand and field tests, has allowed the development of a method of calculation and the improvement of gas turbine combustors.

  • PDF

Model and Field Testing of a Heavy-Duty Gas Turbine Combustor

  • Ahn, Kook-Young;Kim, Han-Seok;Antonovsky, Vjacheslav-Ivanovich
    • Journal of Mechanical Science and Technology
    • /
    • v.15 no.9
    • /
    • pp.1319-1327
    • /
    • 2001
  • The results of stand and field testing of a combustion chamber for a heavy-duty 150 MW gas turbine are discussed. The model represented one of 14 identical segments of a tubular multican combustor constructed 1:1 scale. The model experiments were executed at a lower pressure than that in a real gas turbine. Combustion efficiency, pressure loss factor, pattern factor, liner wall temperature, flame radiation, fluctuating pressure and NOx emission were measured at partial and full loads for both model and on-site testing. The comparison of these items in the stand and field test results led to has the development of a method of calculation and the improvement of gas turbine combustors.

  • PDF

Analysis of hydraulic system for seawater desalination plant through piping analysis program (배관 해석 프로그램을 통한 해수담수화 플랜트 수압 시스템 분석)

  • Choi, Jihyeok;Choi, Yongjun;Yang, Heungsik;Lee, Sangho;Choi, June-Seok
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.34 no.3
    • /
    • pp.221-230
    • /
    • 2020
  • In actual seawater desalination plant, the pressure loss due to frictional force of pipe is about 3~5 bar. Also, the pressure loss at pipe connection about 1~3 bar. Therefore, the total pressure loss in the pipe is expected to be about 4~8 bar, which translates into 0.111 to 0.222 kWh/㎥ of energy when converted into the Specific Energy Consumption(SEC). Reducing energy consumption is the most important factor in ensuring the economics of seawater desalination processes, but pressure loss in piping is often not considered in plant design. It is difficult to prevent pressure loss due to friction inside the pipe, but pressure loss at the pipe connection can be reduced by proper pipe design. In this study, seawater desalination plant piping analysis was performed using a commercial network program. The pressure loss and SEC for each case were calculated and compared by seawater desalination plant size.

Evaluation of Head Loss within In-Line Mixer for Water Treatment using CFD Technique (CFD모사 기법을 이용한 관내 혼화장치내 수두손실 발생 특성 평가)

  • Hwang, Young-Jin;Lim, Sung-Eun;Kim, Seong-Su;Park, No-Suk;Wang, Chang-Keun
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.23 no.1
    • /
    • pp.107-112
    • /
    • 2009
  • This study was conducted for verification and systematization of estimation method about the headloss using CFD(Computational Fluid Dynamics). Head loss which happens between the inlet and outlet of in-line mixer can be a major factor for the design and construction. Also, this Case studies about the sensitivity related to the velocity in the piping system. As result, program's default calculation function was used to get each side's total pressure and the differential of each total pressure could be defined as head loss from in-line mixer. In the case of adopting pipe surface friction factor and geometry loss, Calculation residual can be much more reduced. It was found that residual of value between CFD method and field test ranged about 3 through 18 precent.

A Study on the Concept Design of Vertical Wind Tunnel for Skydiver (고공 강하용 수직풍동의 개념설계에 관한 연구)

  • Cho, Hwan Kee
    • Journal of the Korean Society for Aviation and Aeronautics
    • /
    • v.26 no.2
    • /
    • pp.83-90
    • /
    • 2018
  • This paper describes a case study on the design factor analysis of vertical wind tunnel for skydiver's training or experiencing of paradropping exercise in the air. The case study of vertical wind tunnel design is to provide the knowledges on effects of parameter's variation when it is applied to overall or partial duct of tunnel circuit. The analysis of design parameters based on pressure loss are produced one by one through the tunnel components from the flight chamber because the wind tunnel must satisfy the requirement of flight chamber such as flow speed, quality and quantity. Results shows the various effects of parameter variation with pressure loss in the wind tunnel circuit. Pressure loss should be based on the determination of fan and power system which can be selected from market or new design.

Numerical Investigation on Frictional Pressure Loss in a Perfect Square Micro Channel with Roughness and Particles

  • Han Dong-Hyouck;Lee Kyu-Jung
    • Journal of Mechanical Science and Technology
    • /
    • v.20 no.8
    • /
    • pp.1266-1274
    • /
    • 2006
  • A numerical study is performed to investigate the effect of inner surface roughness and micro-particles on adiabatic single phase frictional pressure drop in a perfect square micro channel. With the variation of particles sizes (0.1 to $1{\mu}m$) and occupied volume ratio (0.01 to 10%) by particles, the Eulerian multi-phase model is applied to a $100{\mu}m$ hydraulic diameter perfect square micro channel in laminar flow region. Frictional pressure loss is affected significantly by particle size than occupied volume ratio by particles. The particle properties like density and coefficient of restitution are investigated with various particle materials and the density of particle is found as an influential factor. Roughness effect on pressure drop in the micro channel is investigated with the consideration of roughness height, pitch, and distribution. Additionally, the combination effect by particles and surface roughness are simulated. The pressure loss in microchannel with 2.5% relative roughness surface can be increased more than 20% by the addition of $0.5{\mu}m$ diameter particles.

The study on the measurement for the pressure drop and friction factor of corrugated metal pipes (주름관에서의 압력강하와 마찰손실 계측에 관한 연구)

  • Yun, Young-Sun;Kang, Jun-One;Yoo, Jai-Suk;Kim, Hyung-Jung
    • Journal of the Korean Society of Visualization
    • /
    • v.4 no.2
    • /
    • pp.76-80
    • /
    • 2006
  • The data for friction factor of the pipe correlated by Reynolds number and relative roughness have been reported well as a Moody chart. However, the results for corrugated shapes have been not investigated sufficiently. In this research, therefore, the pressure drop and friction factor are obtained. Flexible metal tubes with corrugations for the measurement are made of stainless steel plates. The kinds of tubes for the measurement are 5 annular types and helical types. The pressure drop & the velocity of the flow are obtained by micromanometer & digital pressure sensor, supplying dry air at several steps. Then the pressure drop is calculated for each tube, using the obtained data. The result shows that the pressure drop is strongly influenced by the viscous dissipation of kinetic energy due to the circulation of flows, rather than a viscous friction loss. The pressure drop increased consistently as the Reynolds number increases.

  • PDF

Study on the Pressure Loss of Hoses in a Fire Hose Reel Hydrant (호스릴옥내소화전 호스에 대한 압력손실에 관한 연구)

  • Whang, Young-Kwon;Lee, Seung-Chul
    • Fire Science and Engineering
    • /
    • v.33 no.2
    • /
    • pp.63-67
    • /
    • 2019
  • In this study, the pressure loss of a fire hose reel hydrant was examined and the effects of each factor on the pressure loss were analyzed. First, in the pressure loss experiment according to the length of the reel hose, the pressure loss increased with increasing length of the reel hose; it was approximately 38.86% based on a 25 m hose. Second, the pressure loss of the reel hose per unit length was estimated to be $.13{\sim}.15kgf/cm^2$. Third, in the pressure loss experiment according to the change in the flow rate, the result was similar to the relation, flow rate - pressure loss (${\Delta}P{\sim}Q^2$), in the piping flow. These results provide basic data on the evaluation of fire pump pressure and the performance-based fire-protecting design of fire hose reel hydrants used in buildings.

A study on the friction head loss in flat aluminum micro multi tubes with nonazeotropic refrigerant mixtures R-410A (비공비 혼합냉매 R-410A를 적용한 납작한 알루미늄 마이크로 멀티 튜브에서의 마찰손실에 관한 연구)

  • Lee, Jeong-Kun;Min, Kyung-Ho
    • Design & Manufacturing
    • /
    • v.13 no.2
    • /
    • pp.37-43
    • /
    • 2019
  • This study conducted a research as to condensation heat transfer friction loss headby using three types of flat micro multi-channel tubes with different processing of micro-fin and number of channels inside the pipes and different sizes of appearances. In addition, identical studies were conducted by using smoothing circular tubes with 5mm external diameter to study heat enhancement factor and pressure drop penalty factor. 1) The friction head loss showed an increase as the vapor quality and mass flux increased. In case of saturation temperature, it shows an increase as it gets lower. These factors are the reason occurring as the lower the saturation temperature is, the higher the density of refrigerant vapor gets. The influence of heat flux is similar as the dryness is low, but as it gets higher, it lowers in heat flux, and as the high temperature of high heat flux, it is a factor that occurs as the density gets lower. 2) RMS error of the in case of friction head loss, it showed to be predicted as 0.45~0.67 by Chisholm, Friedel, Lockhart and Martinelli. 3) As forfriction head loss penalty factor, the smaller the aspect ratio is, the larger the penalty factor gets, and as for the effect of micro-fin, the penalty factor increased because it decreases to the gas fluid the way groove for the refrigerant's flow.