• 제목/요약/키워드: Pressure Interference

검색결과 235건 처리시간 0.024초

Degrees of Freedom of 3-user MIMO Interference Channels with Instantaneous Relay Using Interference Alignment

  • Qiang, Wang;Yuquan, Shu;Minhua, Dong;Ji, Xu;Xiaofeng, Tao
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • 제9권5호
    • /
    • pp.1624-1641
    • /
    • 2015
  • Instantaneous relay (relay-without-delay) using interference alignment is a promising approach to neutralizing interference and improving system capacity. In Wang Chenwei's work, a 2-user scenario required both source and relay to access the global channel state information (CSI). This paper shows a new method of interference alignment improves the degrees of freedom (DoF) prominently for the 3-user MIMO interference channel with instantaneous relay. This new method is focused on the relay node that completes the alignment interference neutralization so the global CSI is obtained only once and the pressure on the base station can be mitigated. In addition, the 3-user MIMO interference channels with instantaneous relay can achieve 2M DoF when source and destination have M antennas, respectively. This method shows 33% improvement over the conventional method using interference alignment which obtains 3M/2 DoF.

Application of artificial neural network for determination of wind induced pressures on gable roof

  • Kwatra, Naveen;Godbole, P.N.;Krishna, Prem
    • Wind and Structures
    • /
    • 제5권1호
    • /
    • pp.1-14
    • /
    • 2002
  • Artificial Neural Networks (ANN) have the capability to develop functional relationships between input-output patterns obtained from any source. Thus ANN can be conveniently used to develop a generalised relationship from limited and sometimes inconsistent data, and can therefore also be applied to tackle the data obtained from wind tunnel tests on building models with large number of variables. In this paper ANN model has been developed for predicting wind induced pressures in various zones of a Gable Building from limited test data. The procedure is also extended to a case wherein interference effects on a gable roof building by a similar building are studied. It is found that the Artificial Neural Network modelling is seen to predict successfully, the pressure coefficients for any roof slope that has not been covered by the experimental study. It is seen that ANN modelling can lead to a reduction of the wind tunnel testing effort for interference studies to almost half.

Drag reduction of a disk with an upstream rod

  • Zhang, Panfeng;Gao, Lei;Wang, Jinjun
    • Wind and Structures
    • /
    • 제9권3호
    • /
    • pp.245-254
    • /
    • 2006
  • The pressure and drag measurements were carried out in the wind tunnel to investigate the drag reduction of the disk by using an interference rod placed upstream. The results indicate that there is a pair of standing vortices in the front stagnation region of the disk induced by the rod. The standing vortices can decrease the pressure on the disk upwind side; hence it can reduce the drag of the disk. With an increasing rod diameter, the standing vortices are strengthened and more drag reduction can be achieved for the disk. With rod diameter d/D = 0.05 (d, D are the diameters of rod and disk, respectively), the total drag of the disk can be reduced by about 9% compared with that of the bare disk.

산업단지 고압매설배관 안전관리 향상방안 연구 (A Study on the Safety Management of High Pressure Underground Pipeline in Industrial Estate)

  • 최현웅;이동민;김진준
    • 한국가스학회지
    • /
    • 제22권5호
    • /
    • pp.100-106
    • /
    • 2018
  • 국내산업단지 내 고압 매설배관은 장기사용배관이 많고 독성 가연성 불활성 등 고압가스는 물론 다양한 유해화학물질이 한도로 내에 복잡하게 매설되어있어 다양한 타공사 등 사고 발생 시 인접하여 매설된 다른 배관에 손상을 미칠 수 있어 높은 수준의 안전관리가 요구되고 있다. 이에 본 연구에서는 고압가스매설배관과 도시가스매설배관 안전관리실태를 심층비교분석을 통하여 고압가스 매설배관의 효율적인 안전관리방식 도출에 활용하고자한다.

제어관점에서의 부하감지형 유압시스템의 특성 (Properties of the Load-Sensing Hydraulic System from a Viewpoint of Control)

  • 김성동
    • 대한기계학회논문집
    • /
    • 제18권3호
    • /
    • pp.738-750
    • /
    • 1994
  • The load-sensing hydraulic system which was developed to improve energy efficiency of conventional hydraulic systems has its own properties. The instability of system responses, linearity of a servo valve, robustness for variation of external load, and dynamic interference between hydraulic motors are such properties which have much to do with control properties of the system. The load-sensing hydraulic system has instability tendancy because the load-sensing mechanism makes a positive feedback loop between the motor part and the pump part. A flow property of the servo valve can be said to be linear because the flow through the valve has nothing to do with a load pressure and the flow is strictly proportional to a valve opening which is adjusted by a valve command signal. The resultant control property can be said to be robust because the steady-state control performance is independent to the load actuated on the motor shaft. In the case when one pump simultaneously drives more than two hydraulic motors, the pump outlet pressure is determined by a hydraulic motor of the largest load pressure among all of the hydraulic motors, and, thus, the other motors are dominated by the largest load pressure. That is, the other motors can be said to be interfered by the motor of the largest load pressure.

폐쇄형 풍동 시험부내의 진동하는 익형 주위 유동에 대한 비정상 벽면효과 연구 (UNSTEADY WALL INTERFERENCE EFFECT ON FLOWS AROUND AN OSCILLATING AIRFOIL IN CLOSED TEST-SECTION WIND TUNNELS)

  • 강승희;권오준;홍승규
    • 한국전산유체공학회지
    • /
    • 제10권2호
    • /
    • pp.60-68
    • /
    • 2005
  • For study on the unsteady wall interference effect, flows around a forced oscillating airfoil in closed test-section wind tunnels have been numerically investigated by solving compressible Navier-Stokes equations. The numerical scheme is based on a node-based finite-volume method with the Roe's flux-difference splitting and an implicit time-integration method coupled with dual time-step sub-iteration. The Spalart-Allmaras one-equation model is employed for the turbulence effect. The computed results of the oscillating airfoil having a thin wake showed that the lift curve slope is increased and the magnitude of hysteresis loop is reduced by the interference effects. Since the vortex around the airfoil is generated and convected downstream faster than the free-air condition, the phase of lift, drag and pitching moment coefficients was shifted. The pressure on the test section wall shows harmonic terms having the oscillating frequency contained in the wail effect.

Interference effects in a group of tall buildings closely arranged in an L- or T-shaped pattern

  • Zhao, J.G.;Lam, K.M.
    • Wind and Structures
    • /
    • 제11권1호
    • /
    • pp.1-18
    • /
    • 2008
  • Interference effects in five square tall buildings arranged in an L- or T-shaped pattern are investigated in the wind tunnel. Mean and fluctuating shear forces, overturning moments and torsional moment are measured on each building with a force balance mounted at its base. Results are obtained at two values of clear separation between adjacent buildings, at half and a quarter building breadth. It is found that strong interference effect exists on all member buildings, resulting in significant modifications of wind loads as compared with the isolated single building case. Sheltering effect is observed on wind loads acting along the direction of an arm of the "L" or "T" on the inner buildings. However, increase in these wind loads from the isolated single building case is found on the most upwind edge building in the arm when wind blows at a slight oblique angle to the arm. The corner formed by two arms of buildings results in some wind catchment effect leading to increased wind pressure on windward building faces. Interesting interference phenomena such as negative drag force are reported. Interference effects on wind load fluctuations, load spectra and dynamic building responses are also studied and discussed.

국외 천연가스 배관 사고 빈도 비교 및 분석 모형에 관한 연구 (A Study on Failure Frequency Model for Risk Analysis of Natural Gas Pipeline with Comparison of Overseas Failure Data)

  • 오신규
    • 한국가스학회지
    • /
    • 제18권3호
    • /
    • pp.60-66
    • /
    • 2014
  • 본 연구에서는 국내 매설 고압가스배관의 사고빈도 데이터 구축 시 활용할 수 있도록 국외에서 발표하고 있는 고압가스배관 사고빈도 데이터에 대해 고찰 하였다. 고압가스배관 사고빈도 데이터의 대표적인 것으로는 미국의 DOT, 유럽의 EGIG 및 영국의 UKOPA가 있다. 국외 사고빈도 데이터의 국내 적용 가능성을 확인하기 위하여 이들을 비교 분석한 결과 EGIG 데이터가 국내 실정에 더 적합하였다. EGIG 8차 보고서의 사고빈도 데이터를 사용하여 비선형회귀분석을 수행한 결과 배관 설치 연도에 따른 지수형의 곡선을 얻었다. 향후 전체 사고빈도의 약 50%를 차지하고 있는 타공사 부분과 국내 데이터와 국외 데이터의 합성에 대한 집중적인 연구가 필요하다.

Wind induced pressure on 'Y' plan shape tall building

  • Mukherjee, Sourav;Chakraborty, Souvik;Dalui, Sujit Kumar;Ahuja, Ashok Kumar
    • Wind and Structures
    • /
    • 제19권5호
    • /
    • pp.523-540
    • /
    • 2014
  • This paper presents a comprehensive study of pressure developed on different faces of a 'Y' plan shape tall building using both numerical and experimental means. The experiment has been conducted in boundary layer wind tunnel located at Indian Institute of Technology Roorkee, India for flow condition corresponding to terrain category II of IS:875 (Part 3) - 1987, at a mean wind velocity of 10 m/s. Numerical study has been carried out under similar condition using computational fluid dynamics (CFD) package of ANSYS, namely ANSYS CFX. Two turbulence models, viz., $k-{\varepsilon}$ and Shear Stress Transport (SST) have been used. Good conformity among the numerical and experimental results have been observed with SST model yielding results of higher magnitude. Peculiar pressure distribution on certain faces has been observed due to interference effect. Furthermore, flow pattern around the model has also been studied to explain the phenomenon occurring around the model.

Valve Seat/Cylinder Head 단품조립을 위한 상온압입공정 해석 (Analysis of the Room Temperature Fitting Process for Assembling the Part(Valve Seat and Cylinder Head))

  • 배준호;김문생;우타관;김태진;오준동;김철
    • 소성∙가공
    • /
    • 제18권8호
    • /
    • pp.607-616
    • /
    • 2009
  • There are three sub-processes associated with the assembly of the valve seat and cylinder head; heat fitting, cold fitting, and shrink fitting. In the heat fitting stage, the cylinder head is heated to a specified temperature and then squeezed toward the outer diameter of the valve seat. The cold fitting process cools the valve seat and safely squeezes it toward the inner diameter of cylinder head. However, these methods increased the installations & running cost and curtailed productivity. To address these problems, we analyzed the shrink fitting process using the contact pressure caused by fitting interference between the outer diameter of the valve seat and the inner diameter of the cylinder head. In this study, a closed form equation for predicting the contact pressure and fitting load is proposed. For quality control of the assembly line, principal factors of the shrink fitting process influenced in contact pressure were simulated by the FEM. Actual loads measured in the field showed good agreement with the results obtained by theoretical and finite element analysis.