• Title/Summary/Keyword: Pressure Curve

Search Result 1,045, Processing Time 0.035 seconds

Effects of Pilocarpine on Pressure-Volume Curve of the Excised Rabbit Lung and Pulmonary Surfactant (Pilocarpine투여(投與) 가토폐장(家免肺臟)의 압력(壓力)-용적곡선(容積曲線) 및 폐포표면활성물질(肺胞表面活性物質)에 관(關)하여)

  • Lee, Seung-Jung;Chae, Soo-Hi;Lee, Suck-Kang
    • The Korean Journal of Physiology
    • /
    • v.8 no.2
    • /
    • pp.49-53
    • /
    • 1974
  • A single dose of pilocarpine was subcutaneously injected into the rabbit in order to clarify the effects of cholinergic activities on the secretion of the pulmonary surfactant. The animal was sacrificed four hours after the injection, and the pressure-volume curve of the excised lung was obtained. The surfactant activities of the lung washings were also measured, and a comparison was made with the normal. The pressure-volume curve of the excised lung by the injection and ejection of air formed a loop (hysteresis) and the mean intra-alveolar pressure at 35 ml of air was 220 $mmH_20$ in the normal. The mean deflation curve of the pilocarpine treated rabbit lungs was shifted to the left compared with the normal. The surfactant activities were slightly increased than the normal. The above results suggest that pilocarpine stimulates the secretion of the pulmonary surfactant from the Type II alveolar epithelial cell.

  • PDF

Analysis of the Necessary Mechanical Properties of Embroiderable Conductive Yarns for Measuring Pressure and Stretch Textile Sensor Electrodes (생체 신호 측정 압력 및 인장 직물 센서 전극용 자수가 가능한 전도사의 필요 물성 분석)

  • Kim, Sang-Un;Choi, Seung-O;Kim, Joo-Yong
    • Science of Emotion and Sensibility
    • /
    • v.24 no.2
    • /
    • pp.49-56
    • /
    • 2021
  • In this study, we investigated the necessary mechanical properties of conductive multifilament yarns for fabricating the electrodes of biosignal measurement pressure and stretch textile sensors using embroidery. When electrodes and circuits for smart wearable products are produced through the embroidery process using conductive multifilament yarns, unnecessary material loss is minimized, and complex electrode shapes or circuit designs can be produced without additional processes using a computer embroidering machine. However, because ordinary missionary threads cannot overcome the stress in the embroidery process and yarn cutting occurs, herein, we analyzed the S-S curve, thickness, and twist structure, which are three types of silver-coated multifilament yarns, and measured the stress in the thread of the embroidery simultaneously. Thus, the required mechanical properties of the yarns in the embroidery process were analyzed. In the actual sample production, cutting occurred in silver-coated multifilament rather than silver-coated polyamide/polyester, which showed the lowest S-S curve. In the embroidery process, the twist was unwound through repetitive vertical movement. Further, we fabricated a piezoresistive pressure/tension sensor to measure gauge factor, which is an index for measuring biological signals. We confirmed that the sensor can be applied to the fabrication of embroidery electrodes, which is an important process in the mass production of smart wearable products.

Prediction of Soil-Water Characteristic Curve and Relative Permeability of Jumunjin Sand Using Pore Network Model (공극 네트워크 모델을 이용한 주문진표준사의 함수특성곡선 및 상대투수율 예측에 관한 연구)

  • Suh, Hyoung Suk;Yun, Tae Sup;Kim, Kwang Yeom
    • Journal of the Korean Geotechnical Society
    • /
    • v.32 no.1
    • /
    • pp.55-62
    • /
    • 2016
  • This study presents the numerical results of soil-water characteristic curve for sandy soil by pore network model. The Jumunjin sand is subjected to the high resolution 3D X-ray computed tomographic imaging and its pore structure is constructed by the web of pore body and pore channel. The channel radius, essential to the computation of capillary pressure, is obtained based on the skeletonization and Euclidean Distance transform. The experimentally obtained soil-water characteristic curve corroborates the numerically estimated one. The pore channel radius defined by minimum radii of pore throat results in the slightly overestimation of air entry value, while the overall evolution of capillary pressure resides in the acceptable range. The relative permeability computed by a series of suggested models runs above that obtained by pore network model at high degree of saturation.

Qualification of J-R (J-T) Curve from 1/2T Compact-Tension Specimen (1/2T Compact-Tension Type 시편으로 구한 J-R (J-T) 곡선의 타당성 검토.)

  • Jee, Sae-Hwan;Park, Sun-Pil
    • Nuclear Engineering and Technology
    • /
    • v.19 no.3
    • /
    • pp.169-179
    • /
    • 1987
  • The change of material J-R (J-T) curve with crack extension and J-calculation method was investigated to give experimental and analytical method for reliable J-R (J-T) curve, which was adapted recently as a tool for instability analysis of Nuclear Pressure Vessel. Experiments were carried out by Single Specimen Unloading Compliance Method using 1/2"T, Compact-Tension Type fracture mechanic specimens which were the same size and material as domestic nuclear pressure vessel material surveillance specimens. The results revealed that crack extension up to 25~30% of initial uncracked ligament and JD (Deformation theory J) calculation method, currently being used in NUREG-0744, could give rather reliable material J-R (J-T) curve than the small crack extension and JM (Modified J) calculation method. But as JM results more or less higher J at instability, the application of JM should be considered regarding to the problem of power plant availability.lity.

  • PDF

Rupture Prediction of the Rupture Disk Using Elasto-Plastic Analysis (탄소성해석을 이용한 파열판의 파열예측)

  • Han, Houk-Seop;Lee, Won-Bok;Koo, Song-Hoe;Lee, Bang-Eop
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.16 no.3
    • /
    • pp.49-56
    • /
    • 2012
  • Rupture disks are a kind of safety device in high pressure equipment and they are used to control rupture pressure in the solid rocket motor. In this paper, a series of rupture experiments was performed using rupture disks made of AISI 316L and rupture pressure of rupture disks was calculated through various assumptions in relation between elasto-plastic material properties and true stress-strain curve. Experiment and FEA indicated rupture pressure is determined by size of rupture disks. As a result of elasto-plastic analysis, only multi-linear stress-strain curve was able to calculate meaningful estimations. Experimental results also showed rupture location are decided by the size of rupture disks. Experimental and FEA results will be applied to control rupture pressure of disks.

Analysing of pulse wave parameter and typical pulse pattern for diagnosis in floating and sinking pulses (${\cdot}$ 침맥 진단에 유용한 맥상 파라메터 및 대표맥상 분석)

  • Lee, Yu-Jung;Lee, Jeon;Choi, Eun-Ji;Lee, Hae-Jung;Kim, Jong-Yeol
    • Korean Journal of Oriental Medicine
    • /
    • v.12 no.2 s.17
    • /
    • pp.93-101
    • /
    • 2006
  • Pulse feeling is one of the most important diagnosis method in Oriental medicine. But it is not easy to make an objective and standardized diagnosis. In this study, we found how to quantify diagnosis. Specially dally the high practicality in clinic, we search some parameters especially well-related to floating and sinking pulse by statistic analysis. By extension, we find the pulse patterns of the floating and sinking pulse. We choose 15 subjects diagnosed as floating pulse and 15 subjects diagnosed as sinking pulse by oriental doctors. And their pulse signals were acquired by Pulse analyzer which has piezoresistive pressure sensor. For the quantification of the floating and sinking pulse, at first, we examined the parameters which were highly correlated with oriental doctor's diagnosis. And then we derived pulse patterns of the floating-sinking pulse from preprocessed signal and its ensemble average. We also looked trend variation (PH-Curve) between contact and pulse pressure. As a result, statistically there is the biggest difference between contact pressure, the maximum pulse pressure, diastolic area (Ad) and floating and sinking data. Through the PH-Curve, which represented the relationship between contact and pulse pressure, we could divide the floating and sinking pulse clearly. As a basic research of pulse diagnosis algorithm, we can contribute to select essential parameters in diagnosis algorithm And using these diagnosis method, we expect to find typical pulse patterns and some useful parameters about other pulses like slow/rapid, large/fine pulse and so on. We hope that this study will contribute pulse objectification.

  • PDF

A Study on Accuracy of J-Resistance Curves Measured with Curved Compact Tension Specimen of Zr-2.5Nb Pressure Tube (Zr-2.5Nb 압력관의 휘어진 CT시편으로 측정한 J 저항곡선의 정확도에 관한 연구)

  • Yoon, Kee-Bong;Park, Tae-Gyu;Kim, Young-Suk
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.27 no.11
    • /
    • pp.1986-1996
    • /
    • 2003
  • Methodology based on the elastic-plastic fracture mechanics has been widely accepted in predicting the critical crack length(CCL) of pressure tubes of CANDU nuclear plants. A conservative estimate of CCL is obtained by employing the J-resistance curves measured with the specimens satisfying plane strain condition as suggested in the ASTM standard. Due to limited thickness of the pressure tubes the curved compact tension(CT) specimens taken out from tile pressure tube have been used in obtaining J-resistance curves. The curved CT specimen inevitably introduce slant fatigue crack during precracking. Hence, effect of specimen geometry and slant crack on J-resistance curve should be explored. In this study, the difference of J integral values between the standard CT specimens satisfying plane strain condition and the nonstandard curved CT with limited thickness (4.2mm) is estimated using finite element analysis. The fracture resistance curves of Zr-2.5Nb obtained previously by other authors are critically discussed. Various finite element analysis were conducted such as 2D analysis under plane stress and plane strain conditions and 3D analysis for flat CT, curved CT with straight crack and curved CT with slant crack front. J-integral values were determined by local contour integration near the crack tip, which was considered as accurate J-values. J value was also determined from the load versus load line displacement curve and the J estimation equation in the ASTM standard. Discrepancies between the two values were shown and suggestion was made for obtaining accurate J values from the load line displacement curves obtained by the curved CT specimens.

Simulations of the Performance Factors on Vacuum System

  • Kim, Hyung-Taek
    • International journal of advanced smart convergence
    • /
    • v.6 no.4
    • /
    • pp.1-8
    • /
    • 2017
  • In this work, the effects of fairly influential factors on performance of vacuum system, such as constant pressure and outgassing effect were simulated to propose the optimum design factors. Outgassing effects of selected vacuum materials on the vacuum characteristics were simulated by the $VacSim^{Multi}$ simulation tool. This investigation examined the feasibility of reliably simulating the outgassing characteristics of common vacuum chamber materials (aluminum, copper, stainless steel, nickel plated steel, Viton A). The optimum design factors for vacuum systems were suggested based on the simulation results. And, the effects of throttle valve applications on vacuum characteristics were also simulated to obtain the optimum design model of variable conductance on high vacuum system. Simulated vacuum characteristics of the proposed modelling were agreed with the observed experimental behaviour of real systems. Pressure limit valve and normally on-off control valve were schematized as the modelling of throttle valve for the constant process-pressure. Simulation results were plotted as pump-down curve of chamber and variable conductance of throttle valve. Simulated behaviors showed the applications of throttle valve sustained the process-pressure constantly, stably, and reliably.

A Study on the Structure of Three Dimentional Spine, Pelvic Deviation and Foot Pressure in Golf Players (골프선수의 3차원적 척추구조, 골반변위 및 족압에 관한 연구)

  • Yang, Dae-Jung
    • Korean Journal of Applied Biomechanics
    • /
    • v.22 no.2
    • /
    • pp.151-158
    • /
    • 2012
  • The purpose of this study was to investigate variables of significantly difference as the structure of the spine, pelvic deviation and foot pressure between undergraduates and golf player subjects. The subjects of study were composed of 20 male golf players and 20 male undergraduates. Both groups were right handed persons. The measurement tools of this study were Formetric 4D(Diers, Germany) which is a three dimensional measure. The result are the follows: there were a significant difference between golf players and general students of trunk imbalance, pelvic tilt, pelvic torsion, pelvic rotation, surface rotation, lumbar lordotic curve, foot pressure(fore & behind foot), weight distribution(right & left foot). In conclusion, golf players might cause transform of spine and foot pressure due to golf exercise for several years. Such as imbalance affect to induce functional impairment and pain of musculoskeletal system, and appropriate evaluation and treatment were necessary for golf players.

Experiment of small cyclone performance depending on the inlet type (입구형상에 따른 소형 사이클론의 성능 실험)

  • Kim, Min-Ha;Hur, Gwang-Su;Seol, Seoung-Yun
    • Proceedings of the KSME Conference
    • /
    • 2004.04a
    • /
    • pp.1969-1974
    • /
    • 2004
  • The performance of small cyclone is analysed by an experiment for the purpose of developing a bag-less vacuum cleaner. For the high collection efficiency and low pressure loss cyclone, the effect of cyclone inlet feature must be well understood. Four types of the helical inlet are considered to compare with the normal tangential inlet, and also various inlet velocities are used to each inlet type. Based on the reference dimension, each type of inlet shows the changes of the grade efficiency and pressure loss which determine the cyclone quality. The results show that the helical inlet has the smaller cut-size but bigger pressure loss than the tangential inlet. And the degree of opening area influences factors of cyclone performance. As the inlet velocity is increased, the cut-size becomes smaller and the pressure loss becomes bigger of each cyclone. Further studies are required to understand the optimized helical inlet of cyclone.

  • PDF