• Title/Summary/Keyword: Pressure Control Device

Search Result 364, Processing Time 0.029 seconds

Development of a stroke output control algorithm using a fuzzy logic for a left ventricular assist device

  • Choi, Jae-Soon;Choi, Won-Woo;Park, Seong-Keun;Park, Seong-Keun;Min, Byoung-Goo
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1995.10a
    • /
    • pp.514-517
    • /
    • 1995
  • A new stroke output control algorithm with a fuzzy logic for an electrohydraulic left ventricular assist device(EH-LVAD) was developed. The EH-LVAD pumps out blood from left atrium actively. Excessive suction of blood may cause fatal damage in left atrium. The LVAD has to provide a maximal stroke output without collapse of left atrium. In this study a new fuzzy algorithm for predicting and detecting suction and doing proper action on LVAD without using an extra pressure sensor but with bellows pressure signal and motor current signal is developed. The performance of the fuzzy control algorithm is demonstrated by the results from mock circulatory experiments.

  • PDF

Using nano-micro-control technology to improve breathing pressure in vocal music technique teaching innovation

  • Jiayue Cui;Hongliang Zhang
    • Advances in nano research
    • /
    • v.15 no.3
    • /
    • pp.239-251
    • /
    • 2023
  • In the present study, we aim to use nanotechnology sensors/actuators to capture pressure and frequency of voice singers and to send signals for improving breathing pressure. In this regard, a circular composite structure having 3 different layers are used. The core layer is nano-composite material reinforced with graphene nanoplatelets. The face sheets are piezo electric materials connected to electrical circuit capable of measuring and applying voltage to the piezoelectric layers. This sensors have extremely smaller size than conventional sensors attached to the neck of singer and, hence, minimizes the influences on the output voice of the singer. A brief theoretical framework are presented for nonlocal strain gradient theory and geometry of the sensor is described in detail. The controlling procedure along with experimental results on 20 amateur and professional singer participants are also presented. The results of the study indicate that the participants could gain benefit from the device for improving their ability in phonation and keeping their frequency at a constant level although they have difficulty in the beginning of the experiment getting used to the device.

The Effect of Intervention on Hallux Valgus Patient's Foot Pressure (중재방법에 따른 엄지발가락 가쪽휨증 환자의 발바닥 압력분포에 미치는 영향)

  • Kim, Hosung;Kim, Myungchul;Lee, Minsoo
    • Journal of The Korean Society of Integrative Medicine
    • /
    • v.3 no.2
    • /
    • pp.63-72
    • /
    • 2015
  • Purpose: The purpose of this study was to investigate the foot pressure of subjects with hallux valgus following conservative management. Methods: The subjects (20 females) were divided into 2 groups; Hallux valgus group (10) and Control group (10) who could evaluate questionnaire & weight bearing X-ray. All the participants were evaluated distribution of foot pressure by Zebris FDM-S system with conservative management (taping therapy and hallux valgus device) during single-limb stance. Results: The Hallux valgus group (HVG) was significantly different than Control group (CG) in hallux valgus angle(p<0.05). The Hallux valgus group with Foot Device (HVG-FD), Hallux valgus group with Taping (HVG-Tp) and Hallux valgus group with Foot device and Taping (HVG-FD&Tp) was not significantly different than CG in hallux valgus angle (p<0.05). The HVG was not significantly different than CG in forefoot (p1, p2, p3), significantly different than CG in rearfoot (p7) about foot pressure during single-limb stance (p<0.05). The HVG-FO and HVG-FO and TP was significantly different than HVG in forefoot (p1, p2, p3), on significantly different than HVG in rearfoot (p7) about foot pressure during single-limb stance (p<0.05). There was significantly correlation HVG-FO and HVG-FO & TP in forefoot (p1, p2, p3) was negative correlation (p<0.05) and in rearfoot (p7) was positive correlation (p<0.05). Conclusion: This study showed that hallux valgus were effected hallux valgus angle and foot pressure by various treatment methods during single-limb stance. Further study is needed to measure various age and work with hallux valgus for clinical application.

A Study on the Response Time Characteristics Related to Shock Control in the Hydraulic System Using the Fluid Device (유체기구를 이용한 유압계통의 충격치제어에 수반되는 응답시간 변화특성에 관한 연구)

  • Lee, Joo-Seong;Lee, Kye-Bock;Lee, Chung-Gu
    • Proceedings of the KSME Conference
    • /
    • 2001.11b
    • /
    • pp.597-603
    • /
    • 2001
  • Control of pressure transients in a hydraulic system may be important and necessary to avoid failures and to improve the efficiency of operation. Flow restricting devices can result in a decrease in the peak pressure, but may change the response time. The response time has an important effect on both operator and operator perceived smoothness. The response time should correspond to how fast a system responds to a given disturbance at the system boundary. Occasionally the appropriate response time is not easily determined. This study is on the response time characteristics in the hydraulic system studied for the control of response time.

  • PDF

Analysis of Design Parameters For Shunt Valve and Anti-Siphon Device Used to Treat Patients with Hydrocephalus

  • Lee, Chong-Sun;Jang, Jong-Yun;Suh, Chang-Min
    • Journal of Mechanical Science and Technology
    • /
    • v.15 no.7
    • /
    • pp.1061-1071
    • /
    • 2001
  • The present study investigated design parameters of shunt valves and anti-siphon device used to treat patients with hydrocephalus. The shunt valve controls drainage of cerebrospinal fluid (CSF) through passive deflection of a thin and small diaphragm. The anti-siphon device(ASD) is optionally connected to the valve to prevent overdrainage when the patients are in the standing position. The major design parameters influencing pressure-flow characteristics of the shunt valve were analyzed using ANSYS structural program. Experiments were performed on the commercially available valves and showed good agreements with the computer simulation. The results of the study indicated that predeflection of the shunt valve diaphragm is an important design parameter to determine the opening pressure of the valve. The predeflection was found to depend on the diaphragm tip height and could be adjusted by the diaphragm thickness and its elastic modulus. The major design parameters of the ASD were found to be the clearance (gap height) between the thin diaphragm and the flow orifice. Besides the gap height, the opening pressure of the ASD could be adjusted by the diaphragm thickness, its elastic modulus, area ratio of the diaphragm to the flow orifice. Based on the numerical simulation which considered the increased subcutaneous pressure introduced by the tissue capsule pressure on the implanted shunt valve system, optimum design parameters were proposed for the ASD.

  • PDF

Effect of Mesh Screen Device on Over-Expanded Supersonic Jet Noise (메쉬 스크린 장치가 과팽창 초음속 제트소음에 미치는 영향)

  • Kweon, Yong-Hun;Kim, Jae-Hyung;Lim, Chae-Min;Aoki, Toshiyuki;Kim, Heuy-Dong
    • Proceedings of the KSME Conference
    • /
    • 2007.05b
    • /
    • pp.3150-3155
    • /
    • 2007
  • This paper describes an experimental work to investigate the effect of mesh screen device on the jet structure and acoustic characteristics of over-expanded supersonic jet. The mesh screen device is placed into the supersonic jet stream. In order to perturb mainly the initial jet shear layer, the hole is perforated in the central part of the mesh screen. The diameter of the perforated hole and the location of mesh screen device are varied. A Schlieren optical system is used to visualize the flow fields of supersonic jet without and with the mesh screen device. Pitot pressure measurement is carried out to obtain the pressure distribution in the jet flow. Acoustic measurement also is performed to obtain the OASPL and noise spectra. The results obtained show that the jet structure and the jet noise control effectiveness is strongly dependent upon the diameter of the perforated hole and the location of the mesh screen device in the jet stream. Provided that the mesh screen device is placed at the location to perturb effectively the initial shear layer, the present control method is effective in suppressing the supersonic jet noise.

  • PDF

Semi-Actively Controlled Impact System Design (충격장치의 반 능동 제어시스템 설계)

  • Kim, Dong-Hwan;Choi, Moon-Chul;Lee, Kyo-Il
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.16 no.4 s.97
    • /
    • pp.46-56
    • /
    • 1999
  • A semi-actively controlled impact system which adjusts an impulse exerted by the external impact is studies. The main control variables are internal pressure difference inside the cylinder and the shock absorber displacement while it travels. Compared to a conventional one so called a passive system with a variable orifice inside the cylinder, a semi-actively controlled system utilizes an external orifice controlled by a highly fast responding electrical proportional valve. This device overcomes the temperature and viscosity change due to continuous operating and keeps the desired pressure difference and displacement in every operation. In this article a new prototype impact system is designed and manufactured based on a semi-actively control system. Through computer simulations and experiments, we verify the possibility of controlling the shock absorber pressure and displacement. After investigating the control performance a modified semi-actively controlled system with better control performance is also proposed.

  • PDF

Development of A New Device for Controlling Infinitesimal Flows inside a Lab-On-A-Chip and Its Practical Application (랩온어칩 내부 미세유동 제어를 위한 새로운 장치의 개발 및 적용)

  • Kim, Bo-Ram;Kim, Guk-Bae;Lee, Sang-Joon
    • 유체기계공업학회:학술대회논문집
    • /
    • 2006.08a
    • /
    • pp.305-308
    • /
    • 2006
  • For controlling micro-flows inside a LOC (lab-on-a-chip) a syringe pump or an electronic device for EOF(electro-osmotic flow) have been used in general. However, these devices are so large and heavy that they are burdensome in the development of a portable micro-TAS (total analysis system). In this study, a new flow control system employing pressure chambers, digital switches and speed controllers was developed. This system could effectively control the micro-scale flows inside a LOC without any mechanical actuators or electronic devices We also checked the feasibility of this new control system by applying it to a LOC of micro-mixer type. Performance tests show that the developed control system has very good performance. Because the flow rate in LOC is controlled easily by throttling the speed controller, the flows in complicate microchannels network can be also controlled precisely.

  • PDF

Performance Analysis of Pneumatic Device for Verification of Canard Deployment Performance (날개의 전개성능 확인을 위한 공압식 시험장치 성능 해석)

  • Lee, Donghoon
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.19 no.2
    • /
    • pp.145-154
    • /
    • 2016
  • In this paper, a pneumatic device for the deployment performance verification of canards deployed by inertia has been designed and the performance of the pneumatic device has been proven through analysis and tests. The pneumatic conveying process, orifice opening process and piston movement process of the pneumatic device were investigated by using numerical methods. The orifice diameter, pressure in a pressure tank and type of gas were regarded as the main design parameters of the pneumatic device. The error rate between analysis and test results under the same conditions was within 4 %. The accuracy of numerical methods used in this study were validated.

Improvement of a sensor unit for wrist blood pressure monitor (손목형 혈압계의 센서부 개선에 대한 연구)

  • Koo, Sang-Jun;Kwon, Jang-Wan;Park, Yong-Man;Ayuznara, Odgerel;Kim, Hie-Sik
    • Proceedings of the KIEE Conference
    • /
    • 2007.04a
    • /
    • pp.380-382
    • /
    • 2007
  • As the society changes more to the aging society in future, many healthcare product are developed and distributed more on the market. The digital wrist band tye blood pressure device for home use are popular already in the market. It is useful for checking blood pressure level at home and control of hypertension. Especially. It is very essential home device to check the health condition of blood circulation disease. Nowadays many product types are available. But the measurement accuracy of blood pressure is not enough compared to the mechanical type. It needs to be upgraded to assure the precise health data enough to use in the hospital. The structure, feature and output signal of capacitor type pressure sensors are analyzed. An improved design fa capacitor sensor is suggested. It shows more precise health data after use on a wrist band type health unit. They can be applied for remote u-health medical service.

  • PDF