• 제목/요약/키워드: Pressure

검색결과 47,052건 처리시간 0.073초

Effect of the Earth Pressure Coefficient on the Support System in Jointed Rock Mass

  • Son, Moorak;Adedokun, Solomon;Hwang, Youngcheol
    • 한국지반환경공학회 논문집
    • /
    • 제16권2호
    • /
    • pp.33-43
    • /
    • 2015
  • This paper investigated the magnitude and distribution of earth pressure on the support system in jointed rock mass by considering different earth pressure coefficients, rock types and joint inclination angles. The study mainly focused on the effect of the earth pressure coefficients on the earth pressure. Based on a physical model test (Son & Park, 2014), extended studies were conducted considering rock-structure interactions based on the discrete element method, which can consider the joints characteristics of rock mass. The results showed that the earth pressure was highly influenced by the earth pressure coefficients as well as the rock type and joint inclination angles. The effects of the earth pressure coefficients increased when the rock suffered more weathering and has no joint slide. The test results were also compared with Peck's earth pressure for soil ground, and clearly showed that the earth pressure in jointed rock mass can be greatly different from that in soil ground. This study indicated the earth pressure coefficients considering the rock types and joint inclination angles are important parameters influencing the magnitude and distribution of earth pressure, which should be considered when designing the support systems in jointed rock mass.

황백(黃柏)이 토끼의 전립선요도압 및 혈압에 미치는 영향 (The Effects of Cortex Phellodendri on Prostatic Urethral Pressure and Mean Arterial Blood Pressure in an Experimental Rabbit Model)

  • 김은지;한양희
    • 대한한방내과학회지
    • /
    • 제38권2호
    • /
    • pp.110-117
    • /
    • 2017
  • Objective: This study was undertaken to examine the effect of Cortex Phellodendri on prostatic urethral pressure and mean arterial blood pressure of rabbits. Methods: To measure prostatic urethral pressure and mean arterial blood pressure, a Mikro-Tip catheter transducer was inserted and positioned in the prostatic urethra and left carotid artery. After a stabilizing period, phenylephrine ($1{\mu}/kg$) was intravenously administered two or three times to increase the urethral pressure and mean arterial blood pressure. Cortex Phellodendri (2.5 mg/kg and 5 mg/kg doses of Cortex Phellodendri extracted from 80% Ethanol) was administered intravenously, followed by phenylephrine, with no time interval between the doses. The urethral pressure and mean arterial blood pressure were then measured to determine whether they had stabilized. Results and Conclusion: Cortex Phellodendri appeared to inhibit phenylephrine-induced increases in prostatic urethral pressure and mean arterial blood pressure.

Cerebral Hemodynamics in Premature Infants

  • Rhee, Christopher J.;Rios, Danielle R.;Kaiser, Jeffrey R.;Brady, Ken
    • Neonatal Medicine
    • /
    • 제25권1호
    • /
    • pp.1-6
    • /
    • 2018
  • Extremely low birth weight infants remain at increased risk of intraventricular hemorrhage from the fragile vascular bed of the germinal matrix; the roles of hypotension (ischemia) and reperfusion (hyperemia) in the development of intraventricular hemorrhage are still debated. Cerebrovascular pressure autoregulation protects the brain by maintaining constant cerebral blood flow despite changes in blood pressure. The ontogeny of cerebrovascular pressure autoregulation has not been well established and uncertainty remains about the optimal arterial blood pressure required to support brain perfusion. Another important aspect of premature cerebral hemodynamics is the critical closing pressure--the arterial blood pressure at which cerebral blood flow ceases. Interestingly, in premature infants, the critical closing pressure approximates the mean arterial blood pressure. Often in this unique population, cerebral blood flow occurs only during systole when the diastolic arterial blood pressure is equal to the critical closing pressure. Moreover, the diastolic closing margin, a metric of cerebral perfusion that normalizes diastolic arterial blood pressure to the critical closing pressure, may be a better measure than arterial blood pressure for defining cerebral perfusion in premature infants. Elevated diastolic closing margin has been associated with intraventricular hemorrhage. This review summarizes the current state of understanding of cerebral hemodynamics in premature infants.

소화기관내의 압력 모니터링 시스템 (Pressure Monitoring System in Gastro-Intestinal Track)

  • 김용인;박석호;김병규;박종오
    • 제어로봇시스템학회논문지
    • /
    • 제10권11호
    • /
    • pp.1089-1094
    • /
    • 2004
  • Diseases in the gastro-intestinal track are on an increasing trend. In order to diagnose a patient, the various signals of the digestive organ, such as temperature, pH, and pressure, can offer the helpful information. Among the above mentioned signals, we choose the pressure variation as a monitoring signal. The variation of a pressure signal of the gastro-intestinal track can offer the information of a digestive trouble or some clues of the diseases. In this paper, a pressure monitoring system for the digestive organs of a living pig is presented. This system concept is to transmit the measured biomedical signals from a transmitter in a living pig to wireless receiver that is positioned out of body. The integrated solution includes the following parts: (1) the swallow type pressure capsule, (2) the receiving set consisting of a receiver, decoder box, and PC. The merit of the proposed system if that the monitoring system can supply the precise and repeatable pressure in the gastro-intestinal track. In addition, the design of low power consumption enables it to keep sending reliable signals while the pressure capsule is working in the digestive organ. The subject of the study for the pressure monitoring system is in-vivo experiments for a living pig. We achieved the pressure tracings in digestive organs and verified the validity of system after several in-vivo tests using pressure monitoring system. As a result, we found each organ has its own characterized pressure fluctuation.

비압축성 물체의 압력해 안정화를 위한 압력연속여분치의 매개변수 연구 (Parametric Study on the Pressure Continuity Residual for the Stabilization of Pressure in Incompressible Materials)

  • 이상호;김상효
    • 전산구조공학
    • /
    • 제8권4호
    • /
    • pp.189-198
    • /
    • 1995
  • 비압축성 물체를 위한 일반적인 유한요소 공식화는 흔히 사용되는 사각형요소에서조차 압력해의 진동화(oscillations) 또는 pressure modes 현상을 나타낸다. 압력해의 안정화를 위한 규준은 소위 Babuska-Brezzi 안정조건이며, 위의 요소들은 이 조건을 만족시키지 못한다. 본 연구에서는 선형변위해와 상수값의 압력해를 갖는 사각형요소 사용시 압력해를 안정화시키기 위해 요소의 변에서 발생하는 불연속압에 근거한 압력연속여분치를 사용한다. 이 압력여분치를 비압축성 탄성론으로부터 유도되는 Q1P0요소에 적용하며 매개변수의 변화에 따른 수치해의 안정화의 정도를 연구한다. 압력해는 압력 여분치 사용시 안정화될 수 있으며, 해의 안정화는 매개변수에 민감성을 나타내었다.

  • PDF

Heat Transfer Characteristics of an Internally-Heated Annulus Cooled with R-134a Near the Critical Pressure

  • Hong, Sung-Deok;Chun, Se-Young;Kim, Se-Yun;Baek, Won-Pil
    • Nuclear Engineering and Technology
    • /
    • 제36권5호
    • /
    • pp.403-414
    • /
    • 2004
  • An experimental study of heat transfer characteristics near the critical pressure has been performed with an internally-heated vertical annular channel cooled by R-134a fluid. Two series of tests have been completed: (a) steady-state critical heat flux (CHF) tests, and (b) heat transfer tests for pressure reduction transients through the critical pressure. In the present experimental range, the steady-state CHF decreases with increase of the system pressure for fixed inlet mass flux and subcooling. The CHF falls sharply at about 3.8 MPa and shows a trend towards converging to zero as the pressure approaches the critical point of 4.059 MPa. The CHF phenomenon near the critical pressure does not lead to an abrupt temperature rise of the heated wall, because the CHF occurs at remarkably low power levels. In the pressure reduction transients, as soon as the pressure passes below the critical pressure from the supercritical pressure, the wall temperatures rise rapidly up to very high values due to the departure from nucleate boiling. The wall temperature reaches a maximum at the saturation point of the outlet temperature, and then tends to decrease gradually.

욕창 방지를 위한 체압 모니터링 시스템 개발 (Development of The Physical Pressure Monitoring System to Prevent Pressure Ulcers)

  • 이아라;장경배
    • 대한임베디드공학회논문지
    • /
    • 제6권4호
    • /
    • pp.209-214
    • /
    • 2011
  • This study suggests a Healthcare System for elderly and disabled who have mobility impairment and use a wheelchair for long time. Seating long time in a wheelchair without reducing pressure causes high risk of developing pressure sores. Pressure sores come with great deal of pain and often lead to develop complication. Not only it takes time and effort to treat pressure sores but also increases medical expenses. Therefore, we will develop a device to help to prevent pressure sores by measuring pressure distribution while seating in a wheelchair and wirelessly send information to user device to check pressure distribution in real time. The equipment to measure body pressure is composed of FSR sitting mat which is a sensor measuring part and an user terminal which is a monitoring part. The designed mat is matrix formed FSR sensor to measure pressure. The sensor send measured data to the controller which is connected to the end of the mat, and then the collected data are sent to an user terminal through a bluetooth. Developing a pressure monitoring system will help to prevent those who have mobility impairment to manage pressure sores and furthermore relieve their burden of medical expenses.

저압보일러에서 고온의 온수 생성 후 압축기에서 고압수를 생성하는 고온·고압 세척시스템에 관한 연구 (A Study on a High-Temperature/High-Pressure Washing System in which High-Temperature Water is Generated in a Low-Pressure Boiler and High-Pressure Water is Generated Thereafter in a Compressor)

  • 조동현
    • 한국기계가공학회지
    • /
    • 제18권1호
    • /
    • pp.94-100
    • /
    • 2019
  • This study was conducted on a high-temperature/high-pressure washer in which low-pressure cold water in a boiler is heated to a temperature range of $70{\sim}80^{\circ}C$ by supplying diesel combustion heat. The high-temperature water is sent to a compressor to increase its pressure to 200 bar, thereby making high-temperature/high-pressure water, which is sprayed through a spray nozzle. In the results of this study, the spray temperature of the high-pressure washing was shown to be the highest when the ratio between the actual amount of combustible air and the theoretical amount of air was 1:1 and the energy consumption rate of the low-pressure boiler type high-pressure washer was shown to be much lower than that of the high-pressure boiler type high-pressure washer.

Study on PIV-Based Pressure Estimation Method of Wave Loading under a Fixed Deck

  • Lee, Gang Nam;Duong, Tien Trung;Jung, Kwang Hyo;Suh, Sung Bu;Lee, Jae Yong
    • 한국해양공학회지
    • /
    • 제34권6호
    • /
    • pp.419-427
    • /
    • 2020
  • In this study, a particle image velocimetry (PIV)-based pressure estimation method was investigated, with application to the wave-in-deck loading phenomenon. An experimental study was performed in a two-dimensional wave tank using a fixed deck structure under a focused wave, obtaining local pressures by pressure sensors, global loads by load cells, and instantaneous velocity fields using the PIV measurement technique. The PIV-based pressure estimation method was applied using the Euler equation as the governing equation, and the proper time step for the wave impact pressure was studied using the normalized root-mean-square deviation. The pressure estimation method showed good agreement for the local impact pressure in comparison with the measured pressure by the pressure sensors. However, some differences were observed in the peak pressure due to the limitations of the Euler equation and the sampling rate of the measurement system. Using the estimation method, the pressure fields during wave-in-deck loading were determined in the study, with an analysis of the mechanism of impact and negative pressure occurrence.

중대형 굴삭기 유압시스템의 압력 맥동 저감 연구 (A Study on the Pulsation Pressure Reduction for the Hydraulic System of Medium-Large Excavator)

  • 김영현;주원호
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2010년도 추계학술대회 논문집
    • /
    • pp.421-426
    • /
    • 2010
  • With hydraulic noise test facility, a variety of tests were performed to investigate the pulsation pressure generation mechanism and its transmission characteristics and to derive the noise control methodology. Many experiments were carried out by changing average pressure, flow rate, pump speed, hose length and MCV spool condition. From the test results, the correlations between pulsation pressure and other design parameters, such as static pressure, flow rate and MCV spool opening area and length of hose, were found out. And also each contribution factors were evaluated from the regression analysis. By changing hose length, the pulsation pressure resonance phenomenon was investigated. In order to find out the pulsation pressure reduction measures pulsation pressure analysis, such as pulsation pressure of hydraulic pump itself and pulsation pressure of hydraulic system, by using AMESim were studied. In addition hydraulic silencer was developed based on the Helmholtz resonator. And its performance was evaluated by installing the silencer at the excavator.

  • PDF