• 제목/요약/키워드: Pressure

검색결과 47,069건 처리시간 0.06초

노인병원 간호사의 욕창 간호 지식과 욕창 간호 태도가 욕창 간호 수행에 미치는 영향 (The Effects of Pressure Injury Nursing Knowledge and Pressure Injury Nursing Attitude on Pressure Injury Nursing Practices of Nurses in Geriatric Hospitals)

  • 김수올;김소명
    • Journal of Korean Biological Nursing Science
    • /
    • 제24권3호
    • /
    • pp.190-199
    • /
    • 2022
  • Purpose: This study investigated the effect of pressure injury nursing knowledge, and pressure injury nursing attitudes, on pressure injury nursing practice. Methods: Participants in this descriptive study were 141 nurses at 20 geriatric hospitals. Data was collected August 24, 2021- April 4, 2022, and analyzed in terms of Independent t-test and one-way ANOVA, Scheffé test, Pearson's correlation coefficient, and multiple regression, using the SPSS/WIN 27.0 program. Results: Pressure injury nursing practice positively correlated with pressure injury nursing attitudes (r= .44, p< .001). Factors influencing pressure injury nursing practice were pressure injury nursing attitudes (β= .43, p< .001), and gender (β= .21, p= .006). The model used in this study explains 22.8% of pressure injury nursing practice (Adjusted R2= 22.8, F= 11.30, p< .001). Conclusion: Results show factors that influence pressure injury nursing practice of nurses in geriatric hospitals. Based on the results, pressure injury nursing practice programs must include factors that improve pressure injury nursing attitudes. A follow-up study to confirm the impact of developing a program for increasing pressure injury nursing practice is also recommended.

백 프레셔가 압밀시험중 공소수압 발달에 미치는 영향 (Effects of Back Pressure on Pore Pressure During Consolidation Test)

  • 강병희
    • 한국농공학회지
    • /
    • 제14권4호
    • /
    • pp.2770-2776
    • /
    • 1972
  • The needs for reproducing in situ neutral pressure, and for having fully saturated specimens and pore pressure measuring system for consoildation testing were examined in respect to pore pressure development. undisturbed specimens of a sensitive development. undisturbed specimens of a sensitive marine soft clay were tested in the ANTEUS consolidometer with the application of four different magnitudes of back pressure(0,5, 40 and $70lb/in^2$) in order to investigate the effect of back pressure on pore pressure development during consolidation test. The effect of back pressure on pore pressure development during consolidation is striking for back pressure up to $40lb/in^2$) but, above this value, no measurable effects of back pressure variations on pore pressure development are evidenced.

  • PDF

연소실 압력변동과 2차 연료 분사가 스월 화염에서 화염안정화와 배출 특성에 미치는 영향 (Influence of changing combustor pressure and secondary fuel injection on flame stabilization and emission characteristic in swirl flame)

  • 김종률;최경민;김덕줄
    • 한국연소학회:학술대회논문집
    • /
    • 한국연소학회 2007년도 제34회 KOSCO SYMPOSIUM 논문집
    • /
    • pp.133-138
    • /
    • 2007
  • Influence of changing combustor pressure on flame stabilization and emission index in the swirl-stabilized flame was investigated The combustor pressure was controlled by suction fan at combustor exit. Pressure index ($P^{\ast}=P_{abs}/P_{atm}$), where $P_{abs}$ and $P_{atm}$ indicated the absolute pressure and atmosphere pressure, respectively, was controlled in the range of $0.7{\sim}1.3$ for each equivalence ratio conditions. The flammable limits of swirl flames were largely influenced by changing combustor pressure and they showed similar tendency with laminar flames. $NO_x$ emission index decreased with decreasing pressure index for overall equivalence ratio conditions. R.m.s. of pressure fluctuations is increased with decreasing combustor pressure. This flame fluctuation caused incomplete combustion , hence CO emission index increased. These oscillating flames were measured by simultaneous $CH{\ast}$ chemiluminescence time-series visualization and pressure fluctuation measurement.

  • PDF

압력보정법을 이용한 8개의 원심압축기 임펠러 CFD의 적용 연구 (Application of Pressure Correction Method to CFD Work for 8 Centrifugal Compressor Impellers)

  • 오종식;노수혁;현용익
    • 유체기계공업학회:학술대회논문집
    • /
    • 유체기계공업학회 2000년도 유체기계 연구개발 발표회 논문집
    • /
    • pp.226-235
    • /
    • 2000
  • Two representative finite volume methods, i.e., the time marching method and the pressure correction method, were applied to 8 centrifugal compressor impeller flows, with low to very high level of pressure ratio, among which 7 impellers' experimental performance is given in the open literature. The present study is focused on the prediction differences from both methods, developed by the authors, in the pressure correction method's point of view. In all cases, the time marching method gives a satifactory solution, but the pressure correction method does not. Up to about $18\%$ less level of total-to-total pressure ratio is predicted by the pressure correction method as the level of the impeller pressure ratio increases up to about 10. The drop of total pressure ratio is caused by the underestimation of static pressure rise which seems to be attributed to inappropriate linearization and discretization of the pressure/density coupling terms in the pressure correction equation.

  • PDF

충돌 분무의 성장에 미치는 분사압과 배압의 영향에 관한 연구 (A study on the effect of injection pressure and ambient pressure for the growth of impinging spray)

  • 차건종;서경일;김덕줄
    • 대한기계학회논문집B
    • /
    • 제21권11호
    • /
    • pp.1458-1465
    • /
    • 1997
  • This study investigated the effects of pressure on the growth of an impinging spray. We obtained the frozen images which were scattered by Nd ; YAG laser light (pulse width : 7 ns) using synchronization circuit made in the laboratory. For an impinging spray a growth of the penetration length was progressed with increase of the injection pressure but an ambient pressure restrained its growth. The effect of an ambient pressure on penetration was larger than that of an injection pressure. The pressure ratio had an effect on the penetration growth rate. The thickness growth rate depended on both the injection pressure and the ambient pressure compositively. A lower injection pressure or a higher ambient pressure was required for spatial distribution of impinging spray.

이침시술이 혈압에 미치는 영향 (The Effect of Auricular Acupuncture Therapy on Blood Pressure)

  • 이진구;이영구;윤희식
    • 대한한의학회지
    • /
    • 제24권2호
    • /
    • pp.12-18
    • /
    • 2003
  • Objectives : Hypertension is very prevalent disease, and causes serious cardiovascular complications. Nowadays optimal hypertension treatment is emphasized to reduce the incidence of cardiovascular complications. Auricular acupuncture therapy is economical, safe and effective. Its clinical application is various, and it can be used to control blood pressure. So The effect of auricular acupuncture therapy was investigated. Daily variation of blood pressure during needle-embedded period and variation of blood pressure by blood pressure classification were observed. Methods : The auricular acupuncture points we used were Gangapjeom (降壓點), Sinmun (神門), Gyogam (交感), Sim(心), and Icheom (耳尖). Auricular acupuncture needles were embedded for three days. Blood pressure was checked four times per day and the mean obtained. Results : The following results were obtained : 1. During needle-embedded period, systolic and diastolic blood pressure decreased. Blood pressure decreased most significantly 2 days after treatment. 2. The change of blood pressure in the higher blood pressure group was more remarkable than that of the lower blood pressure group. Conclusions : Through this research, auricular acupuncture therapy is considered as an effective and safe method to lower blood pressure.

  • PDF

폭굉을 고려한 압력용기 최대허용압력 결정방법의 제안 (Method for Determination of Maximum Allowable Pressure of Pressure Vessel Considering Detonation)

  • 최진복
    • 한국전산구조공학회논문집
    • /
    • 제31권5호
    • /
    • pp.235-241
    • /
    • 2018
  • 압력용기의 내압은 압력용기 설계의 중요한 인자이며 이를 바탕으로 관련 설계기준 및 구조해석결과에 따라 압력용기의 두께 및 직경과 같은 기하학적 형상이 결정된다. 그러나 압력용기 내부에서 폭굉이 일어날 경우 이 폭굉압력을 적절히 고려하여 압력용기를 설계할 수 있는 설계기준은 미흡한 실정이다. 일반적으로 폭굉이 발생할 경우, 초기 폭굉압력이 용기 벽면에 도달하여 반사하는 반사압력은 초기압력의 2배 이상이라고 알려진다. 그러나 폭굉압력은 구조물의 고유주기보다도 짧은 시간 안에 최대치에 도달한 후 급격하게 감소하는 경향을 보이며, 이 경우 실제 용기벽면이 받게 되는 압력은 반사압력에 비해 매우 작을 수 있다. 따라서 본 연구에서는 이러한 폭굉의 특성을 고려하여 압력용기가 견뎌야 하는 적절한 등가의 폭굉압력을 산정하는 방법을 제안함으로써 폭굉을 고려한 효율적인 압력용기 설계기준을 제시하고자 하였다.

Borehole stability analysis in oil and gas drilling in undrained condition

  • Wei, Jian-Guang;Yan, Chuan-Liang
    • Geomechanics and Engineering
    • /
    • 제7권5호
    • /
    • pp.553-567
    • /
    • 2014
  • Borehole instability during drilling process occurs frequently when drilling through shale formation. When a borehole is drilled in shale formation, the low permeability leads to an undrained loading condition. The pore pressure in the compressed area near the borehole may be higher than the initial pore pressure. However, the excess pore pressure caused by stress concentration was not considered in traditional borehole stability models. In this study, the calculation model of excess pore pressure induced by drilling was obtained with the introduction of Henkel's excess pore pressure theory. Combined with Mohr-Coulumb strength criterion, the calculation model of collapse pressure of shale in undrained condition is obtained. Furthermore, the variation of excess pore pressure and effective stress on the borehole wall is analyzed, and the influence of Skempton's pore pressure parameter on collapse pressure is also analyzed. The excess pore pressure decreases with the increasing of drilling fluid density; the excess pore pressure and collapse pressure both increase with the increasing of Skempton's pore pressure parameter. The study results provide a reference for determining drilling fluid density when drilling in shale formation.

맥진 깊이 판단을 위한 실시간 압력 측정기 (Real-Time Pressure-Measuring System for Evaluating the Depth of Pulse)

  • 조정호;김대복;김기왕
    • 동의생리병리학회지
    • /
    • 제27권3호
    • /
    • pp.313-317
    • /
    • 2013
  • In order to standardize the pressure/depth against radial artery, the externally-applied-pressure measuring system was fabricated and evaluated. Based on the resistance-variable characteristic of the very thin($10{\mu}m$) film conductive tape along the pressure of a tip of a examiner's hand, this system was designed. The change of the pressure was processed through voltage regulator and Matlab S/W, then showed on computer monitor. The signal output through voltage regulator, and Matlab S/W was evaluated on various conditions. The evaluation was executed on these cases; an examiner slowly increases and decreases the pressure, rapidly increases and decreases the pressure, sequentially increases and decreases the pressure, sustains the pressure, micro-changes the pressure. As a pulse examiner varies the pressure on the radial artery of the examinee, the system's real-time output consistently varies according to the pressure. From the results, it is concluded that this system consistently shows the pressure of the tip of a examiner's hand in real time without interrupting the evaluation of the radial artery pulse. Therefore this system is expected to standardize the value of the pressure/depth externally applied by an examiner.

과량수혈이 혈역학에 미치는 영향 (Hemodynamic effects of induced overtransfusion of blood in dogs)

  • 기노석
    • Journal of Chest Surgery
    • /
    • 제17권3호
    • /
    • pp.418-423
    • /
    • 1984
  • Appreciation of the large volume deficits which may occur in surgical or trauma patients due to blood loss has led to vigorous transfusion techniques designed to overt hypovolemic shock and ischemic damage to vital organs which may develop in minutes during the hypovolemic state. In a significant proportion of patients treated with massive rapid blood or fluid transfusion, hypervolemia occurs and life threatening pulmonary edema may develop. Especially, hypervolemia may occur during transfusion for preventing development of the so-called low output syndrome following cardiac surgery. However, the most effective indicator which reveals the adequate level of transfusion is not settled yet. The present study was aimed to compare the effectiveness of the indicators suggested thus far and to determine the most sensitive one. Eight dogs were experimentally studied in terms of left atrial pressure, pulmonary arterial systolic pressure, central venous pressure, mean systemic arterial pressure and heart rate before and after induced hypervolemia with infusion of 600ml heparinized homologous blood. Immediately after induced overtransfusion of the blood, pulmonary arterial systolic pressure increased 75.0%, in omparison with the control before transfusion, left atrial pressure 58.8%, central venous pressure 44.6%, and mean systemic arterial pressure 10.1%, one hour after transfusion, pulmonary arterial systolic pressure 40.0%, left atrial pressure 21.2%, central venous pressure 14.5%, and mean systemic arterial pressure 3.2%, central venous pressure 14.5%, and mean systemic arterial pressure 3.2%, respectively. Heart rate showed no significant change throughout the experiment. These result suggested that the changes of the pulmonary arterial systolic pressure is the most sensitive indicator for detection of hypervolemia during blood transfusion.

  • PDF