• 제목/요약/키워드: Press-over

검색결과 1,322건 처리시간 0.027초

A strain-based wire breakage identification algorithm for unbonded PT tendons

  • Abdullah, A.B.M.;Rice, Jennifer A.;Hamilton, H.R.
    • Smart Structures and Systems
    • /
    • 제16권3호
    • /
    • pp.415-433
    • /
    • 2015
  • Tendon failures in bonded post-tensioned bridges over the last two decades have motivated ongoing investigations on various aspects of unbonded tendons and their monitoring methods. Recent research shows that change of strain distribution in anchor heads can be useful in detecting wire breakage in unbonded construction. Based on this strain variation, this paper develops a damage detection model that enables an automated tendon monitoring system to identify and locate wire breaks. The first part of this paper presents an experimental program conducted to study the strain variation in anchor heads by generating wire breaks using a mechanical device. The program comprised three sets of tests with fully populated 19-strand anchor head and evaluated the levels of strain variation with number of wire breaks in different strands. The sensitivity of strain variation with wire breaks in circumferential and radial directions of anchor head in addition to the axial direction (parallel to the strand) were investigated and the measured axial strains were found to be the most sensitive. The second part of the paper focuses on formulating the wire breakage detection framework. A finite element model of the anchorage assembly was created to demonstrate the algorithm as well as to investigate the asymmetric strain distribution observed in experimental results. In addition, as almost inevitably encountered during tendon stressing, the effects of differential wedge seating on the proposed model have been analyzed. A sensitivity analysis has been performed at the end to assess the robustness of the model with random measurement errors.

Seismic behavior of steel reinforced concrete (SRC) joints with new-type section steel under cyclic loading

  • Wang, Qiuwei;Shi, Qingxuan;Tian, Hehe
    • Steel and Composite Structures
    • /
    • 제19권6호
    • /
    • pp.1561-1580
    • /
    • 2015
  • No significant improvement has been observed on the seismic performance of the ordinary steel reinforced concrete (SRC) columns compared with the reinforced concrete (RC) columns mainly because I, H or core cross-shaped steel cannot provide sufficient confinement for core concrete. Two improved SRC columns by constructing with new-type section steel were put forward on this background: a cross-shaped steel whose flanges are in contact with concrete cover by extending the geometry of webs, and a rotated cross-shaped steel whose webs coincide with diagonal line of the column's section. The advantages of new-type SRC columns have been proved theoretically and experimentally, while construction measures and seismic behavior remain unclear when the new-type columns are joined onto SRC beams. Seismic behavior of SRC joints with new-type section steel were experimentally investigated by testing 5 specimens subjected to low reversed cyclic loading, mainly including the failure patterns, hysteretic loops, skeleton curves, energy dissipation capacity, strength and stiffness degradation and ductility. Effects of steel shape, load angel and construction measures on seismic behavior of joints were also analyzed. The test results indicate that the new-type joints display shear failure pattern under seismic loading, and steel and concrete of core region could bear larger load and tend to be stable although the specimens are close to failure. The hysteretic curves of new-type joints are plumper whose equivalent viscous damping coefficients and ductility factors are over 0.38 and 3.2 respectively, and this illustrates the energy dissipation capacity and deformation ability of new-type SRC joints are better than that of ordinary ones with shear failure. Bearing capacity and ductility of new-type joints are superior when the diagonal cross-shaped steel is contained and beams are orthogonal to columns, and the two construction measures proposed have little effect on the seismic behavior of joints.

Wireless structural health monitoring of bridges: present and future

  • Hoult, Neil A.;Fidler, Paul R.A.;Hill, Peter G.;Middleton, Campbell R.
    • Smart Structures and Systems
    • /
    • 제6권3호
    • /
    • pp.277-290
    • /
    • 2010
  • Internationally the load carrying capacity of bridges is decreasing due to material deterioration while at the same time increasing live loads mean that they are often exposed to stresses for which they were not designed. However there are limited resources available to ensure that these bridges are fit for purpose, meaning that new approaches to bridge maintenance are required that optimize both their service lives as well as maintenance costs. Wireless sensor networks (WSNs) provide a tool that could support such an optimized maintenance program. In many situations WSNs have advantages over conventional wired monitoring systems in terms of installation time and cost. In order to evaluate the potential of these systems two WSNs were installed starting in July 2007 on the Humber Bridge and on a nearby approach bridge. As part of a corrosion prevention strategy, a relative humidity and temperature monitoring system was installed in the north anchorage chambers of the main suspension bridge where the main cables of the bridge are anchored into the foundation. This system allows the Bridgemaster to check whether the maximum relative humidity threshold, above which corrosion of the steel wires might occur, is not crossed. A second WSN which monitors aspects of deterioration on a reinforced concrete bridge located on the approach to the main suspension bridge was also installed. Though both systems have provided useful data to the owners, there are still challenges that must be overcome in terms of monitoring corrosion of steel, measuring live loading and data management before WSNs can become an effective tool for bridge managers.

전국 도시재정비사업 추진실태 분석을 통한 개선방안 고찰: 주택재개발사업 및 주택재건축사업을 중심으로 (Analyzing the Current Situation and Issues of Urban Renewal Projects in Korea: Focused on Housing Redevelopment Projects and Housing Reconstruction Projects)

  • 임정민;이영환;김재승;김성연
    • 토지주택연구
    • /
    • 제4권4호
    • /
    • pp.333-348
    • /
    • 2013
  • 최근 정비사업은 부동산 경기침체에 따른 사업성 악화, 정비구역의 과다 지정, 사업추진 과정상 이해관계자 간의 갈등 및 비리 발생 등 여러 가지 원인에 의해 수도권 일부지역을 제외한 전국 대부분의 지역에서 사업 추진이 매우 부진한 실정이다. 이에 따라 전국의 각 지역별 정비사업 추진실태에 대한 면밀한 조사 분석과 함께 사업추진 단계별 문제점 분석을 통하여 정비사업 정상화를 위한 제도적 개선방안의 마련이 필요하다. 본 연구에서는 전국 개별 정비구역에 대한 구체적 현황자료 및 언론보도자료를 바탕으로 전국적 정비사업 추진실태에 대해서 지역별 사업별로 비교 분석하였다. 이러한 분석결과를 토대로 다음과 같이 정비사업에 대한 개선방안을 제시하였다. 첫째, 보다 장기적 관점에서 정비기본계획의 수립 및 정비예정구역의 지정이 필요하다. 둘째, 대규모 정비사업보다는 지역의 다양한 여건에 부합할 수 있는 소규모 단위의 점진적 정비사업으로 전환되어야 한다. 셋째, 지방의 여건을 고려한 중앙정부의 지원이 이루어져야 한다. 또한, 민간 중심의 사업방식에서 벗어나 민간과 공공의 파트너십 형성과 통하여 정비사업의 투명성 제고, 사업여건 개선, 공공의 역할 확대를 통한 새로운 방향의 협력적 정비사업으로의 전환이 필요하다.

Design and ultimate behavior of RC plates and shells: two case studies

  • Min, Chang-Shik
    • Structural Engineering and Mechanics
    • /
    • 제14권2호
    • /
    • pp.171-190
    • /
    • 2002
  • Two cases of design are performed for the hyperbolic paraboloid saddle shell (Lin-Scordelis saddle shell) and the hyperbolic cooling tower (Grand Gulf cooling tower) to check the design strength against a consistent design load, therefore to verify the adequacy of the design algorithm. An iterative numerical computational algorithm is developed for combined membrane and flexural forces, which is based on equilibrium consideration for the limit state of reinforcement and cracked concrete. The design algorithm is implemented in a finite element analysis computer program developed by Mahmoud and Gupta. The amount of reinforcement is then determined at the center of each element by an elastic finite element analysis with the design ultimate load. Based on ultimate nonlinear analyses performed with designed saddle shell, the analytically calculated ultimate load exceeded the design ultimate load from 7% to 34% for analyses with various magnitude of tension stiffening. For the cooling tower problem the calculated ultimate load exceeded the design ultimate load from 26% to 63% with similar types of analyses. Since the effective tension stiffening would vary over the life of the shells due to environmental factors, a degree of uncertainty seems inevitable in calculating the actual failure load by means of numerical analysis. Even though the ultimate loads are strongly dependent on the tensile properties of concrete, the calculated ultimate loads are higher than the design ultimate loads for both design cases. For the cases designed, the design algorithm gives a lower bound on the design ultimate load with respect to the lower bound theorem. This shows the adequacy of the design algorithm developed, at least for the shells studied. The presented design algorithm for the combined membrane and flexural forces can be evolved as a general design method for reinforced concrete plates and shells through further studies involving the performance of multiple designs and the analyses of differing shell configurations.

Non-linear time-dependent post-elastic analysis of suspended cable considering creep effect

  • Kmet, S.;Tomko, M.;Brda, J.
    • Structural Engineering and Mechanics
    • /
    • 제22권2호
    • /
    • pp.197-222
    • /
    • 2006
  • In this paper, the non-linear time-dependent closed-form, discrete and combined solutions for the post-elastic response of a geometrically and physically non-linear suspended cable to a uniformly distributed load considering the creep effects, are presented. The time-dependent closed-form method for the particularly straightforward determination of a vertical uniformly distributed load applied over the entire span of a cable and the accompanying deflection at time t corresponding to the elastic limit and/or to the elastic region, post-elastic and failure range of a suspended cable is described. The actual stress-strain properties of steel cables as well as creep of cables and their rheological characteristics are considered. In this solution, applying the Irvine's theory, the direct use of experimental data, such as the actual stress-strain and strain-time properties of high-strength steel cables, is implemented. The results obtained by the closed-form solution, i.e., a load corresponding to the elastic limit, post-elastic and failure range at time t, enable the direct use in the discrete non-linear time-dependent post-elastic analysis of a suspended cable. This initial value of load is necessary for the non-linear time-dependent elastic and post-elastic discrete analysis, concerning incremental and iterative solution strategies with tangent modulus concept. At each time step, the suspended cable is analyzed under the applied load and imposed deformations originated due to creep. This combined time-dependent approach, based on the closed-form solution and on the FEM, allows a prediction of the required load that occurs in the post-elastic region. The application of the described methods and derived equations is illustrated by numerical examples.

Predicting shear capacity of NSC and HSC slender beams without stirrups using artificial intelligence

  • El-Chabib, H.;Nehdi, M.;Said, A.
    • Computers and Concrete
    • /
    • 제2권1호
    • /
    • pp.79-96
    • /
    • 2005
  • The use of high-strength concrete (HSC) has significantly increased over the last decade, especially in offshore structures, long-span bridges, and tall buildings. The behavior of such concrete is noticeably different from that of normal-strength concrete (NSC) due to its different microstructure and mode of failure. In particular, the shear capacity of structural members made of HSC is a concern and must be carefully evaluated. The shear fracture surface in HSC members is usually trans-granular (propagates across coarse aggregates) and is therefore smoother than that in NSC members, which reduces the effect of shear transfer mechanisms through aggregate interlock across cracks, thus reducing the ultimate shear strength. Current code provisions for shear design are mainly based on experimental results obtained on NSC members having compressive strength of up to 50MPa. The validity of such methods to calculate the shear strength of HSC members is still questionable. In this study, a new approach based on artificial neural networks (ANNs) was used to predict the shear capacity of NSC and HSC beams without shear reinforcement. Shear capacities predicted by the ANN model were compared to those of five other methods commonly used in shear investigations: the ACI method, the CSA simplified method, Response 2000, Eurocode-2, and Zsutty's method. A sensitivity analysis was conducted to evaluate the ability of ANNs to capture the effect of main shear design parameters (concrete compressive strength, amount of longitudinal reinforcement, beam size, and shear span to depth ratio) on the shear capacity of reinforced NSC and HSC beams. It was found that the ANN model outperformed all other considered methods, providing more accurate results of shear capacity, and better capturing the effect of basic shear design parameters. Therefore, it offers an efficient alternative to evaluate the shear capacity of NSC and HSC members without stirrups.

Prediction on load carrying capacities of multi-storey door-type modular steel scaffolds

  • Yu, W.K.;Chung, K.F.
    • Steel and Composite Structures
    • /
    • 제4권6호
    • /
    • pp.471-487
    • /
    • 2004
  • Modular steel scaffolds are commonly used as supporting scaffolds in building construction, and traditionally, the load carrying capacities of these scaffolds are obtained from limited full-scale tests with little rational design. Structural failure of these scaffolds occurs from time to time due to inadequate design, poor installation and over-loads on sites. In general, multi-storey modular steel scaffolds are very slender structures which exhibit significant non-linear behaviour. Hence, secondary moments due to both $P-{\delta}$ and $P-{\Delta}$ effects should be properly accounted for in the non-linear analyses. Moreover, while the structural behaviour of these scaffolds is known to be very sensitive to the types and the magnitudes of restraints provided from attached members and supports, yet it is always difficult to quantify these restraints in either test or practical conditions. The problem is further complicated due to the presence of initial geometrical imperfections in the scaffolds, including both member out-of-straightness and storey out-of-plumbness, and hence, initial geometrical imperfections should be carefully incorporated. This paper presents an extensive numerical study on three different approaches in analyzing and designing multi-storey modular steel scaffolds, namely, a) Eigenmode Imperfection Approach, b) Notional Load Approach, and c) Critical Load Approach. It should be noted that the three approaches adopt different ways to allow for the non-linear behaviour of the scaffolds in the presence of initial geometrical imperfections. Moreover, their suitability and accuracy in predicting the structural behaviour of modular steel scaffolds are discussed and compared thoroughly. The study aims to develop a simplified and yet reliable design approach for safe prediction on the load carrying capacities of multi-storey modular steel scaffolds, so that engineers can ensure safe and effective use of these scaffolds in building construction.

Injectable TGF-beta 3-conjugated hyaluronic acid hydrogel for cartilage regeneration

  • Ko, Ki Seong;Lee, Jung Seok;Park, Kyung Min;Lee, Yunki;Oh, Dong Hwan;Son, Joo Young;Kwon, Oh Hee;Eom, Min Yong;Park, Ki Dong
    • Biomaterials and Biomechanics in Bioengineering
    • /
    • 제2권1호
    • /
    • pp.23-32
    • /
    • 2015
  • Facile immobilization of growth factors in hyaluronic acid (HA) hydrogels using dual enzymes is reported in the paper. The hydrogels were formed by using horseradish peroxidase (HRP) and hydrogen peroxide ($H_2O_2$) and transforming growth factor-${\beta}3$ (TGF-${\beta}3$) was covalently conjugated on the hydrogels in situ using tyrosinase (Ty) without any modifications. For the preparation of hydrogels, HA was grafted with poly(ethylene glycol) (PEG), which was modified with a tyrosine. The gelation times of the HA hydrogels were ranging from 415 to 17 s and the storage moduli was dependent on the concentration of $H_2O_2$ and Ty (470-1600 Pa). A native TGF-${\beta}3$ (200 ng/mL) was readily encapsulated in the HA hydrogels and 17% of the TGF-${\beta}3$ was released over 1 month at the Ty concentration of 0.5 KU/mL, while the release was faster when 0.3 KU/mL of Ty was used for the encapsulation (27%). It can be suggested that the growth factors resident in the hydrogels for a long period of time may lead cells proliferating and differentiating, whereas the growth factors that are initially released from the hydrogels can induce the ingrowth of cells into the matrices. Therefore, the dual enzymatic methods as facile gel forming and loading of various native growth factors or therapeutic proteins could be highly promising for tissue regenerative medicines.

A new damage identification approach based on impedance-type measurements and 2D error statistics

  • Providakis, Costas;Tsistrakis, Stavros;Voutetaki, Maristella;Tsompanakis, Yiannis;Stavroulaki, Maria;Agadakos, John;Kampianakis, Eleftherios;Pentes, George
    • Structural Monitoring and Maintenance
    • /
    • 제2권4호
    • /
    • pp.319-338
    • /
    • 2015
  • The electro-mechanical impedance (EMI) technique makes use of surface-bonded lead zirconate titanate (PZT) patches as impedance transducers measuring impedance variations monitored on host structural components. The present experimental work further evaluate an alternative to the conventional EMI technique which performs measurements of the variations in the output voltage of PZT transducers rather than computing electromechanical impedance (or admittance) itself. This paper further evaluates a variant of the EMI approach presented in a previous work of the present authors, suitable, for low-cost concrete structures monitoring applications making use of a credit card-sized Raspberry Pi single board computer as core hardware unit. This monitoring approach is also deployed by introducing a new damage identification index based on the ratio between the area of the 2-D error ellipse of specific probability of EMI-based measurements containment over that of the 2-D error circle of equivalent probability. Experimental results of damages occurring in concrete cubic and beam specimens are investigated under increasing loading conditions. Results illustrate that the proposed technique is an efficient approach for identification and early detection of damage in concrete structures.