• Title/Summary/Keyword: Preoperative planning

Search Result 162, Processing Time 0.024 seconds

Arthroscopic Latarjet procedure: current concepts and surgical techniques

  • Sang-Jin Shin;Jae Hyung Kim;Jonghyun Ahn
    • Clinics in Shoulder and Elbow
    • /
    • v.26 no.4
    • /
    • pp.445-454
    • /
    • 2023
  • The Latarjet procedure is a surgical procedure that can effectively restore glenohumeral stability, especially in patients with anterior shoulder instability and glenoid bone loss. Many studies have shown comparable clinical outcomes between patients undergoing the arthroscopic Latarjet procedure and those undergoing traditional open methods or other glenohumeral joint stabilization procedures. However, the arthroscopic Latarjet procedure is a challenging technique due to the unfamiliar portal placements, proximity of neurovascular structures, and serious postoperative complications. The arthroscopic Latarjet procedure has not yet been widely applied, and a clear understanding of the anatomical structure and the precise methods is required prior to operation performance. Satisfactory clinical outcomes can be achieved by thorough preoperative planning and proper implant fixation methods.

A Computed Tomographic Study on the Size and Bone Wall Thickness of the Maxillary Sinus in Normal, Preoperative and Postoperative Maxillary Sinusitis Patients (술전ㆍ후 상악동염환자와 정상인의 상악동 크기 및 골벽두께에 관한 전산화단층방사선학적 연구)

  • Choi Sun-Young;Lee Sang-Rae;Koh Kwang-Joon
    • Imaging Science in Dentistry
    • /
    • v.30 no.2
    • /
    • pp.109-116
    • /
    • 2000
  • Purpose : To compare the size and bone wall thickness of the maxillary sinus in normal, preoperative and postoperative maxillary sinusitis patients. Materials and Methods : The author analyzed CT images of both left and right maxillary sinuses in 357 patients who visited Chonbuk National University Hospital between January 1997 and December 1998. The size and bone wall thickness of the maxillary sinus of normal, inflammatory and post-Caldwell-Luc groups were compared. Results: The significant differences of transverse, maximum medio-lateral, maximum supero-inferior dimensions and medio-lateral dimension at nasal floor level between normal and post-Caldwell-Luc groups were found (P<0.05). And the significant differences of antero-posterior dimensions between inflammatory and post-Caldwell-Luc group were found (P<0.05). But, no significant differences of vertical height dimensions between groups was found (P>0.05). The significant differences of postero-lateral, infero-lateral and medial wall thickness between normal and post-Caldwell-Luc groups were found (P<0.05). Conclusion : The results of this study will aid in the diagnosis and treatment of maxillary sinus diseases and post operative treatment planning.

  • PDF

Validity of Frozen Biopsy during Thyroidectomy (갑상전 절제술시 동결절편조직검사의 유용성에 대한 평가)

  • Kim Seong-Yeal;Kim Jung-Gu;Choi Young-Sik
    • Korean Journal of Head & Neck Oncology
    • /
    • v.14 no.1
    • /
    • pp.81-87
    • /
    • 1998
  • Fine needle aspiration cytology was used widely to select thyroid nodules for surgery. The result could be highly reliable for most malignancies and for benign nodules. The purpose of this study was to determine the value of frozen biopsy by directly comparing the results of preoperative fine needle aspiration cytology to frozen biopsy examination. In our university hospital, 103 patients with thyroid nodule were operated during the years 1996 through 1997. A comparison of accuracy of the fine needle aspiration cytology with frozen biopsy was made for 85 patients who underwent both procedures. The 85 patients were separated into two groups. The group I included 65 patients, whose preoperative fine needle aspiration cytology results were reported as benign or malignant lesion definitely. The group II included 85 patients, the patients whose reported fine needle aspiration cytologic result was suspicious for malignancy were regarded .as malignant lesion and results for follicular neoplasm were regarded as benign lesion. The accuracy of both procedures was compared on two group also. The sensitivity, specificity, and accuracy of frozen biopsy were 76.7%, 93.5%, and 85.2% in group I and 75.6%, 95.5%, and 85.9% in group II, respectively, compared with 63.3%, 87.1%, and 75.4% in group I and 65.4%, 81.8%, and 72.9% in group II for fine needle aspiration cytology. On benign lesion, the accuracy was 95.5% in frozen biopsy and 68.2% in fine needle aspiration cytology, 75.6% in frozen biopsy and 53.7% in fine needle aspiration cytology on malignant lesion. We conclude that although fine needle aspiration cytology is the reliable diagnostic test in the evaluation of thyroid nodule, frozen biopsy should be performed intraoperatively, because fine needle aspiration cytology is insufficiently sensitive for reliable surgical planning.

  • PDF

Three-Dimensional Surface Imaging is an Effective Tool for Measuring Breast Volume: A Validation Study

  • Lee, Woo Yeon;Kim, Min Jung;Lew, Dae Hyun;Song, Seung Yong;Lee, Dong Won
    • Archives of Plastic Surgery
    • /
    • v.43 no.5
    • /
    • pp.430-437
    • /
    • 2016
  • Background Accurate breast volume assessment is a prerequisite to preoperative planning, as well as intraoperative decision making in breast reconstruction surgery. The use of three-dimensional surface imaging (3D scanning) to assess breast volume has many advantages. However, before employing 3D scanning in the field, the tool's validity should be demonstrated. The purpose of this study was to confirm the validity of 3D-scanning technology for evaluating breast volume. Methods We reviewed the charts of 25 patients who underwent breast reconstruction surgery immediately after total mastectomy. Breast volumes using the Axis Three 3D scanner, water-displacement technique, and magnetic resonance imaging (MRI) were obtained bilaterally in the preoperative period. During the operation, the tissue removed during total mastectomy was weighed and the specimen volume was calculated from the weight. Then, we compared the volume obtained from 3D scanning with those obtained using the water-displacement technique, MRI, and the calculated volume of the tissue removed. Results The intraclass correlation coefficient (ICC) of breast volumes obtained from 3D scanning, as compared to the volumes obtained using the water-displacement technique and specimen weight, demonstrated excellent reliability. The ICC of breast volumes obtained using 3D scanning, as compared to those obtained by MRI, demonstrated substantial reliability. Passing-Bablok regression showed agreement between 3D scanning and the water-displacement technique, and showed a linear association of 3D scanning with MRI and specimen volume, respectively. Conclusions When compared with the classical water-displacement technique and MRI-based volumetry, 3D scanning showed significant reliability and a linear association with the other two methods.

Tumour Markers in Peritoneal Washing Fluid - Contribution to Cytology

  • Yildirim, Mustafa;Suren, Dinc;Yildiz, Mustafa;Alikanoglu, Arsenal Sezgin;Kaya, Vildan;Doluoglu, Suleyman Gunhan;Aydin, Ozgur;Yilmaz, Necat;Sezer, Cem;Karaca, Mehmet
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.14 no.2
    • /
    • pp.1027-1030
    • /
    • 2013
  • Background: Peritoneal washing cytology (PWC) that shows the microscopic intra-peritoneal spread of gynaecologic cancers is not used in staging but is known as prognostic factor and effective in planning the intensity of the therapy. False negative or false positive results clearly affect the ability to make the best decision for therapy. In this study we assessed levels of tumour markers, carcinoembryonic antigen (CEA), cancer antigen 125 (CA-125) and carbohydrate antigen (CA19-9), in peritoneal washing fluid to establish any possible contribution to the peritoneal washing cytology in patients operated for gynaecologic cancer. Materials and Methods: Preoperative tumour markers were studied in serum of blood samples obtained from the patients for preoperative evaluation of a gynaecologic operation. In the same group peritoneal tumour markers were studied in the washing fluid obtained for intraoperative cytological evaluation. Results: This study included a total of 94 patients, 62 with malignant and 32 with benign histopathology. The sensitivity of the cytological examination was found to be 21% with a specificity of 100%. When evaluated with CEA the sensitivity of the cytological examination has increased to 37%. Conclusions: In addition to examination of PWC, the level of CEA, a tumour marker, in peritoneal washing fluid can make a diagnostic contribution. Determining the level of CEA in peritoneal washing fluid will be useful in the management of gynaecologic cancers.

Utility of Lateral Circumflex Femoral Artery Perforator's 3D Image with MD-CT (MD-CT로 얻은 가쪽넙다리휘돌이 관통동맥 3D 영상의 유용성)

  • Park, Soo Ho;Shim, Jeong Su;Lee, Sang Kon;Park, Dae Hwan
    • Archives of Plastic Surgery
    • /
    • v.35 no.4
    • /
    • pp.379-384
    • /
    • 2008
  • Purpose: Currently, using perforator artery flaps especially anterolateral thigh flaps are widely used for reconstruction of extremities, head and neck. Obtaining a precise anatomical picture prior to operation will translate to a more accurate, efficient and safe procedure. Authors used 3D-image work up via 64-slice MDCT to make a more precise preoperative plan. Methods: A total of 10 patients underwent soft tissue reconstruction with anterolateral thigh flap from December 2006 to December 2007. The 64-Channel MDCT (LightSpeed VCT, GE, USA) was used and 3D images were reconstructed. Findings from MDCT were applied to the preoperative planning and confirmed with intraoperative findings. Results: The average number of perforator arteries from lateral circumflex femoral artery was 2. The average lengths of vascular pedicle from the origin of lateral circumflex femoral artery to the first and second perforator artery were 11.0 cm and 20.0 cm, respectively. The average diameter of the pedicle artery was 2.2 mm. The locations of the perforator arteries were mapped and localized on the body surface based on the MDCT result. These were confirmed through direct visualization intraoperatively. Conclusion: MDCT has an advantage of obtaining accurate images of the general anatomy and even fine structures like perforator arteries. By using this state-of-the-art diagnostic imaging technique, it is now possible to make an operative plan safely and easily.

The Change of Bone and Soft Tissue Profile after Sagittal Split Osteotomy of Ramus (하악골후방이동술 후 골격구조와 연부조직의 변화)

  • Hwang, Jee Hoon;Seul, Chul Hwan;Park, Beyoung Yun
    • Archives of Plastic Surgery
    • /
    • v.32 no.5
    • /
    • pp.547-554
    • /
    • 2005
  • Orthognathic surgery for Class III malocclusion requires an elaborate preoperative planning using cephalometries or Mock surgery models which enable the surgeon to anticipate postoperative skeletal changes of maxilla and mandible as well as dentition. After surgery, patient's satisfaction is greatly influenced by appearance of soft tissue change. Therefore, it is imperative to predict a relatively accurate soft tissue change prior to surgery. A 5 year retrospective study was designed to evaluate the soft tissue change after sagittal split osteotomy of ramus(SSRO) for class III malocclusion. Analyses of preoperative and postoperative anthropometric measurements were performed. Patients who were treated only by SSRO for class III malocclusion and could follow up for 6 months were studied. Among them, the patients who had history of cleft palate and lip or hemifacial microsomia were excluded. Soft tissue changes were estimated by using the frontal and lateral photographs. Skeletal changes were observed by measuring amount of set back and angular changes of mandible to the reference line by using cephalometries. Relapses were also measured 6 months after the operation. We could observe skeletal changes were more profound than soft tissue changes concerning amount of set back, but soft tissue changes were also profound in angle. Relapse was more profound in skeleton than soft tissue but the amount was not significant. In spite of the variables which may affect proper assessment of the soft tissue change after skeletal relocation, this study can serve as a guide for exact prediction of the postoperative change of soft tissue and skeleton.

Good functional results with open reduction and internal fixation for locked posterior shoulder fracture-dislocation: a case series

  • Nicolas Moran;Michael Marsalli;Mauricio Vargas;Joaquin De la Paz;Marco Cartaya
    • Clinics in Shoulder and Elbow
    • /
    • v.25 no.4
    • /
    • pp.288-295
    • /
    • 2022
  • Background: There is no standardized therapeutic strategy for locked posterior shoulder fracture-dislocation (PSFD), and no consensus exists on the analysis of preoperative factors. This retrospective study aimed to evaluate functional results and complications in a series of PSFD cases managed with open surgical treatment. Methods: Patients diagnosed with locked PSFD who underwent open surgical treatment with reduction and osteosynthesis between April 2016 and March 2020 were included. All participants were treated with open reduction and internal fixation. Functional assessment used the modified University of California, Los Angeles (UCLA) mod scale, American Shoulder and Elbow Surgeons (ASES) questionnaire, subjective shoulder value (SSV), and visual analog scale (VAS). Complications were evaluated clinically and radiologically by X-ray and computed tomography. Results: Twelve shoulders were included (11 patients; mean age, 40.6 years; range, 19- 62 years). The mean follow-up duration was 23.3 months (range, 12-63 months). The UCLA mod, ASES, SSV, and VAS scores were 29.1±3.7, 81.6±13.5, 78±14.8, and 1.2±1.4 points, respectively. The overall complication rate was 16.6%, with one case of post-traumatic stiffness, 1 case of chronic pain, and no cases of avascular necrosis. Conclusions: Open surgical treatment of locked PSFD can achieve good functional results. A correct understanding of these injuries and good preoperative planning helped us to achieve a low rate of complications.

Robotic-assisted Total Hip Arthroplasty and Spinopelvic Parameters: A Review

  • Steven J. Rice;Anthony D'Abarno;Hue H. Luu
    • Hip & pelvis
    • /
    • v.36 no.2
    • /
    • pp.87-100
    • /
    • 2024
  • Total hip arthroplasty (THA) is an effective treatment for osteoarthritis, and the popularity of the direct anterior approach has increased due to more rapid recovery and increased stability. Instability, commonly caused by component malposition, remains a significant concern. The dynamic relationship between the pelvis and lumbar spine, deemed spinopelvic motion, is considered an important factor in stability. Various parameters are used in evaluating spinopelvic motion. Understanding spinopelvic motion is critical, and executing a precise plan for positioning the implant can be difficult with manual instrumentation. Robotic and/or navigation systems have been developed in the effort to enhance THA outcomes and for implementing spinopelvic parameters. These systems can be classified into three categories: X-ray/fluoroscopy-based, imageless, and computed tomography (CT)-based. Each system has advantages and limitations. When using CT-based systems, preoperative CT scans are used to assist with preoperative planning and intraoperative execution, providing feedback on implant position and restoration of hip biomechanics within a functional safe zone developed according to each patient's specific spinopelvic parameters. Several studies have demonstrated the accuracy and reproducibility of robotic systems with regard to implant positioning and leg length discrepancy. Some studies have reported better radiographic and clinical outcomes with use of robotic-assisted THA. However, clinical outcomes comparable to those for manual THA have also been reported. Robotic systems offer advantages in terms of accuracy, precision, and potentially reduced rates of dislocation. Additional research, including conduct of randomized controlled trials, will be required in order to evaluate the long-term outcomes and cost-effectiveness of robotic-assisted THA.

Implant surgery based on computer simulation surgical stent and the assessment with the image fusion technique (컴퓨터 시뮬레이션 기반의 외과용 스텐트를 이용한 임플란트 시술과 영상융합기술을 이용한 평가)

  • Lee, Jee-Ho;Kim, Soung-Min;Paeng, Jun-Young;Kim, Myung-Jin
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.36 no.5
    • /
    • pp.402-407
    • /
    • 2010
  • Introduction: The planning of implant surgery is an important factor for the implant prosthesis. Stereolithographic (SLA) surgical stents based on a computer simulation are quite helpful for clinicians to perform the surgery as planned. Although many clinical and technical trials have been performed for computed tomography (CT)-guided implant stents to improve the surgical procedures and prosthetic treatment, there are still many problems to solve. We developed a system of a surgical guide based on 3 dimensional (3D) CT for implant therapy and achieved satisfactory results in the terms of planning and operation. Materials and Methods: Fifteen patients were selected and 30 implant fixtures were installed. The preoperative CT data for surgical planning were prepared after obtaining informed consent. Surgical planning was performed using the simulation program, Ondemend3D In2Guide. The stents were fabricated based on the simulation data containing information of the residual bone, the location of the nerve, and the expected design of the prostheses. After surgery with these customized stents, the accuracy and reproducibility of implant surgery were evaluated based on the computer simulation. The data of postoperative CT were used to confirm this system using the image fusion technique and compare the implant fixtures between the planned and implanted. Results: The mean error was 1.18 (${\pm}0.73$) mm at the occlusal center, 1.23 (${\pm}0.67$) mm at the apical center, and the axis error between the two fixtures was $3.25^{\circ}C$ (${\pm}3.00$). These stents showed superior accuracy in maxilla cases. The lateral side error at the apical center was significantly different from the error at the occlusal center but there were no significant differences between the premolars, 1st molars and 2nd molars. Conclusion: SLA surgical stents based on a computer simulation have the satisfactory accuracy and are expected to be useful for accurate planning and surgery if some errors can be improved.