• Title/Summary/Keyword: Premixed ratio

Search Result 313, Processing Time 0.02 seconds

Flame Transfer Function Measurement in a Premixed Combustor (예혼합 연소기에서의 화염 전달 함수 측정)

  • Kim, Dae-Sik;Kim, Ki-Tae;Chen, Seung-Bae;Lee, Jong-Guen;Santavicca, Domenic
    • Journal of the Korean Society of Combustion
    • /
    • v.13 no.2
    • /
    • pp.1-6
    • /
    • 2008
  • An experimental study of the flame response in a turbulent premixed combustor has been conducted with room temperature, atmospheric pressure inlet conditions using premixed natural gas. The fuel is premixed with the air upstream of a choked inlet to avoid equivalence ratio fluctuations. Therefore the observed flame response is only the result of the imposed velocity fluctuations, which are produced using a variable speed siren. Measurements are made of the velocity fluctuation in the nozzle using hot wire anemometry and of the heat release fluctuation in the combustor using chemiluminescence emission. The results are analyzed to determine the phase and gain of the flame transfer function as a function of the modulation frequency. Of particular interest is the effect of flame structure on the flame response predictions and measurements. The results show that both the gain and the phase of flame transfer function are closely associated with the flame length and structure, which is dependent upon the upstream flow perturbation as well as equivalence ratio in the current study.

  • PDF

Study on the Combustion Characteristics of a Lean-Premixed Combustor (예혼합 희박 연소기의 연소특성에 관한 연구)

  • Kim, Han-Seok;Lim, Am-Ho;Ann, Kuk-Young;Lee, Sang-Min
    • Journal of the Korean Society of Combustion
    • /
    • v.9 no.1
    • /
    • pp.25-31
    • /
    • 2004
  • Various types of the air/fuel pre-mixer have been designed and tested to investigate the combustion characteristics of the lean-premixed gas turbine combustor, such as NO emission and flame stability. One type of the pre-mixers has been selected and installed to a 70 kW lean-premixed gas turbine combustor. The concentrations of CO and NO were measured with varying equivalence ratios in the combustion chamber at ambient pressure. The result shows that the emissions of CO and NO are heavily affected by the shape of the pre-mixer. The NO and CO emissions decreased, as the mixing ratio of air and fuel increased. In addition, the NO emission of the lean-premixed low NOx combustor is more dependent on the equivalence ratio than that of the conventional combustor.

  • PDF

A Study on NOx Emission and the Characteristics of Partially Premixed Flame (부분 예혼합 화염의 NOx 배출과 화염특성에 관한 실험적 연구)

  • Choi, Ju-Seok;Chun, Chul-Kyun
    • 한국연소학회:학술대회논문집
    • /
    • 2001.06a
    • /
    • pp.156-162
    • /
    • 2001
  • The effects of co-flow and the variation of the equivalence ratio on NOx emission were investigated experimentally for unconfined and confined partially premixed flames. The shape, length, temperature of flames and the concentration of burnt gas were measured. Two types of co-flow (parallel and swirling co-flow) were considered. For unconfined flames, flame with parallel co-flow is the longest and the next is flame without co-flow. Flame with swirl is the shortest. The length of swirling flame increases suddenly under certain value of equivalence ratio. EINOx is diminished by the decrease of equivalence ratio. It is found that the unconfining of flame enhances the emission of NOx. The EINOx of unconfined flame with parallel co-flow is less than that of flame without co-flow.

  • PDF

Study on Flame Stability Using a Slot Burner (슬롯버너를 이용한 예혼합화염의 안정성에 관한 연구)

  • Lee, Won-Nam;Seo, Dong-Kyu
    • 한국연소학회:학술대회논문집
    • /
    • 2001.11a
    • /
    • pp.97-103
    • /
    • 2001
  • The characteristics of flame stability have been studied experimentally using a slot burner. The blowout conditions of a fuel-lean premixed laminar flame, which is located in the middle of fuel-rich premixed laminar flames, are identified for propane, ethylene, and methane flames. The fuel-rich flames could stabilize the fuel-lean flame for the equivalence ratio as low as 0.2. The laminar flame speed along with the heat release rate is likely to be the important factor in stabilizing a fuel-lean flame. The increase of heat release rate on a fuel-rich flame lowers the equivalence ratio limit for the stable fuel-lean flames. The stability of fuel-lean flames, however, was not sensitive to the equivalence ratio of a fuel-rich flame.

  • PDF

Frequency-Equivalence Ratio Correlation Analysis of Methane-Air Premixed Flame Influenced by Ultrasonic Standing Wave (II) (정상초음파의 영향을 받는 메탄-공기 예혼합화염의 주파수-당량비 상관도 분석(II))

  • Kim, Min Sung;Bae, Dae Seok;Kim, Jeong Soo
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.19 no.4
    • /
    • pp.45-51
    • /
    • 2015
  • An experimental study was performed for the analysis of frequency-equivalence ratio correlation in the methane-air premixed flame influenced by ultrasonic standing wave. The propagating flame was caught by high-speed Schlieren photography, and the variation of flame-behavior including the flame structure was investigated in detail employing a post-processing analysis of the high-speed images. It was found that a structural variation and propagation-velocity augmentation of the methane-air premixed flame by the intervention of ultrasonic standing wave were more caused off around the stoichiometry. Also, a dependency of the flame behaviors on the driving frequency and equivalence ratio of the reactants was confirmed.

Preheated Air Combustion Characteristics of Partially Premixed Flame (부분 예혼합 화염의 예열공기 연소특성)

  • Lee, Seung-Young;Lee, Jong-Ho;Jeon, Chung-Hwan;Chang, Young-June
    • Proceedings of the KSME Conference
    • /
    • 2001.11b
    • /
    • pp.65-70
    • /
    • 2001
  • OH radical and NOx have been measured in a methane-air partially premixed flame using PLIF technique to define preheated air combustion characteristics. The temperature of mixture is determined by 300K, 400K, 600K and 800K below the auto-ignition temperature respectively. Flame height increases as equivalence ratio increased. As initial enthalpy is supplied, the radius of flame was increased and much amount of yellow flame in rich equivalence ratio was observed. This is due to the faster burning velocity. Also initial oxidization begins earlier as the initial temperature of mixture increased. It means that height of premixed flame front decreased. This phenomenon can be observed OH PLIF image. The qualitative analysis of OH concentration in the PLIF image shows that overall OH concentration increases with equivalence ratio and the initial temperature of mixture increased. At the preheating temperature goes up, axial gradient of OH concentration is less steep than that of lower temperature condition. This may identify that combustion reacts continuously, so preheated air combustion can evade the local heating and make high temperature indiscriminately in the overall reaction zone.

  • PDF

Effects of the Equivalence Ratio on Propagation Characteristics of CH4-Air Premixed Flame Intervened by an Ultrasonic Standing Wave (정상초음파가 개재하는 CH4-Air 예혼합화염의 전파특성에 대한 당량비의 영향)

  • Seo, Hang Seok;Lee, Sang Shin;Kim, Jeong Soo
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.17 no.2
    • /
    • pp.16-23
    • /
    • 2013
  • An experimental study has been conducted to investigate the effects of equivalence ratio on the propagation characteristics of $CH_4$-air premixed flame intervened by an ultrasonic standing wave. A Schlieren photography was used for the flame structure visualization, and the flame propagation behavior was investigated in detail throughout the post-processing analysis. It is found that the structural variation of methane/air premixed flame caused by the intervention of ultrasonic standing wave give rise to the enhancement of combustion reaction and flame propagation velocity. Effectiveness of the standing wave on the flame velocity decreases as the equivalence ratio increases. Larger flame velocity with the standing wave becomes undistinguishable in a specific range of equivalence ratios.

A Fundamental Study of Hybrid Combustion System Applying Exhaust Gas Recirculation (배기가스 재순환을 적용한 하이브리드 연소시스템에 대한 기초 연구)

  • Oh, Wheesung;Yu, Byeonghun;Park, Taejoon;Lee, Chang-Eon
    • Journal of Energy Engineering
    • /
    • v.25 no.1
    • /
    • pp.100-107
    • /
    • 2016
  • In this study confirmed the reduction effect of pollutant by applying Fi-EGR and FPI-EGR to hybrid combustion system realizing premixed flame and non-premxied flame at once. The results showed that NOx emission index decreased significantly in case of adopting EGR. Additionally, the hybrid combustion system with EGR resulted in a better performance compared to usual non-premixed combustion system such that it can reduce $NO_x$ emission at equivalent EGR ratios. Especially, in the case of 25% of FI-EGR ratio at hybrid combustion system that the ratio of non-premixed and premixed is 50 : 50, NOx emission index reduction rate was about 59% compared to $NO_x$ emission of non-premixed combustion system without EGR and in the case of 15% of FPI-EGR ratio at hybrid combustion system that the ratio of non-premixed and premixed is 70 : 30, $NO_x$ emission index reduction rate was about 48% compared to $NO_x$ emission of hybrid combustion system without EGR.

Behaviors of Premixed Flames and Triple Flames with its Concentration Difference in a Slot Burner (슬롯버너에서 농도차이에 따른 예혼합화염과 삼지화염의 거동)

  • Kim, Tae-Kwon;Jang, Jun-Young;Park, Jeong;Jun, Seong-Hwa;Miwa, Kei
    • 한국연소학회:학술대회논문집
    • /
    • 2004.11a
    • /
    • pp.85-90
    • /
    • 2004
  • We have presented characteristics of a transitional behavior from a premixed flame to a triple flame in a lifted flame according to the change of equivalence ratio. The experimental apparatus consisted of a slot burner and a contraction nozzle for a lifted flame. As concentration difference of the both side of slot burner increases, the shape of flame changed from a premixed flame to a triple flame, and the liftoff height is decreased to the minimum value and then increase again. Around this minimum point, it is confirmed a transition regime from premixed flame to triple flame. Consequently, the experimental results of the liftoff height, flame curvature and luminescence intensity showed that the stabilized laminar lifted flame regime is categorized by regimes of premixed flame, triple flame and critical flame. In the visualization experiment of smoke wire, the flow divergence and redirection reappeared in premixed flame as well as triple flame. Thus we cannot express the flame front of lifted flame has a behavior of triple flame with only flow divergence and redirection. To differentiate triple flame and premixed flame, ${\Phi}$ value of partially premixed fraction is employed. The partially premixed fraction ${\Phi}$ was constant in premixed flame. In critical flame small gradient appears over the whole regime. In triple flame, typical diffusion flame shape is obtained as parabolic distribution type due to diffusion flame trailing.

  • PDF

3D RANS Simulation and the Prediction by CRN Regarding NOx in a Lean Premixed Combustion in a Gas Turbine Combustor (희박 예혼합 가스터빈 연소기 3 차원 전산 해석 및 화학반응기 네트워크에 의한 NOx 예측)

  • Yi, Jae-Bok;Jeong, Dae-Ro;Huh, Kang-Yul;Jin, Jae-Min;Park, Jung-Kyu;Lee, Min-Chul
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.35 no.12
    • /
    • pp.1257-1264
    • /
    • 2011
  • This paper presents 3D simulation by STAR-CCM+ for lean premixed combustion in a stationary gas turbine combustor with separate pilot and main nozzles. The constant for the source term in the flame area density transport equation was modified to account for a low global equivalence ratio and validated against measurement data. A Partially-premixed Coherent Flame Model(PCFM) involves propagation of a laminar premixed flame with the predicted flame surface density and equilibrium assumption in the burned gas with spatial inhomogeneity. The conditions for cooling by radiation and convection are considered for accurate determination of the heat flux on the wall. A parametric study is of the pilot-fuel-to-total-fuel-ratio is carried out. A chemical reactor network (CRN) was constructed on the basis of the 3D simulation results and compared against measurements of NOx.