A Transitional Behavior of a Premixed Flame and a Triple Flame in a Lifted Flame(II) (부상화염에서 예혼합화염과 삼지화염의 천이적 거동(II))

  • Jang Jun Young;Kim Tae Kwon
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.29 no.3 s.234
    • /
    • pp.376-383
    • /
    • 2005
  • In the paper we investigate characteristics of a transitional behavior from a premixed flame to a triple flame in a lifted flame according to the change of equivalence ratio. In previous study, we showed that the stabilized laminar lifted flame regime is categorized by regimes of premixed flame, triple flame and critical flame. A gas-chromatograph is used to measure concentration field, a smoke-wire system is used to measure streak line, and a PIV system is used to measure velocity field in lifted flame. In the visualization experiment of smoke wire, the flow divergence and redirection reappeared in premixed flame as well as triple flame. Thus we cannot express the flame front of lifted flame has a behavior of triple flame with only flow divergence and redirection. In PIV measurement, flow velocity for those three flames has minimum value at the tip of flame front. To differentiate triple flame and premixed flame, $\Phi$ value of partially premixed fraction is employed. The partially premixed fraction $\Phi$ was constant in premixed flame. In critical flame small gradient appears over the whole regime. In triple flame, typical diffusion flame shape is obtained as parabolic distribution type due to diffusion flame trailing.

Behaviors of Premixed Flames and Triple Flames with its Concentration Difference in a Slot Burner (슬롯버너에서 농도차이에 따른 예혼합화염과 삼지화염의 거동)

  • Kim, Tae-Kwon;Jang, Jun-Young;Park, Jeong;Jun, Seong-Hwa;Miwa, Kei
    • 한국연소학회:학술대회논문집
    • /
    • 2004.11a
    • /
    • pp.85-90
    • /
    • 2004
  • We have presented characteristics of a transitional behavior from a premixed flame to a triple flame in a lifted flame according to the change of equivalence ratio. The experimental apparatus consisted of a slot burner and a contraction nozzle for a lifted flame. As concentration difference of the both side of slot burner increases, the shape of flame changed from a premixed flame to a triple flame, and the liftoff height is decreased to the minimum value and then increase again. Around this minimum point, it is confirmed a transition regime from premixed flame to triple flame. Consequently, the experimental results of the liftoff height, flame curvature and luminescence intensity showed that the stabilized laminar lifted flame regime is categorized by regimes of premixed flame, triple flame and critical flame. In the visualization experiment of smoke wire, the flow divergence and redirection reappeared in premixed flame as well as triple flame. Thus we cannot express the flame front of lifted flame has a behavior of triple flame with only flow divergence and redirection. To differentiate triple flame and premixed flame, ${\Phi}$ value of partially premixed fraction is employed. The partially premixed fraction ${\Phi}$ was constant in premixed flame. In critical flame small gradient appears over the whole regime. In triple flame, typical diffusion flame shape is obtained as parabolic distribution type due to diffusion flame trailing.

  • PDF

A Transitional Behavior of a Premixed Flame and a Triple Flame in a Lifted Flame(I) (부상화염에서 예혼합화염과 삼지화염의 천이적 거동(I))

  • Jang Jun Young;Park Jeong;Kim Tae Kwon
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.29 no.3 s.234
    • /
    • pp.368-375
    • /
    • 2005
  • We have presented characteristics of a transitional behavior from a premixed flame to a triple flame in a lifted flame according to the change of equivalence ratio. The experimental apparatus consisted of a slot burner and a contraction nozzle for a lifted flame. As concentration difference of the both side of slot burner increases, the shape of flame changed from a premixed flame to a triple flame, and the liftoff height decreased to the minimum value and then increased again. Around this minimum point, it is confirmed a transition regime from premixed flame to triple flame. Consequently, the experimental results of the liftoff height, flame curvature, and luminescence intensity showed that the stabilized laminar lifted flame regime is categorized by regimes of premixed flame, triple flame and critical flame.

Flame Stabilization and Structures in Narrow Combustion Space (좁은 연소공간에서의 화염 안정화와 화염구조)

  • Kim, Nam Il
    • 한국연소학회:학술대회논문집
    • /
    • 2012.11a
    • /
    • pp.159-162
    • /
    • 2012
  • Combustion in a narrow space has been interested as a model of meso-scale combustors (or micro-combustors). Premixed flames have been used to overcome flame quenching in a narrow space and non-premixed flames have been used to improve flame stabilization. In this study, overall characteristics of premixed flame and non-premixed flame in narrow combustion spaces were reviewed. Various effects such as the flow velocity distribution, thermal interaction, enhanced mass diffusion were discussed and an eventual structure of the flame at the extinction limit was introduced.

  • PDF

Control the Blow-off Characteristics of Lean Premixed Flames Utilizing a Stratified Flame Concept (성층화된 화염을 이용한 희박 예혼합화염의 날림 특성 제어)

  • Lee, Wonnam;Ahn, Taekook;Nam, Younwoo
    • Journal of the Korean Society of Combustion
    • /
    • v.17 no.4
    • /
    • pp.11-20
    • /
    • 2012
  • The Blow-off characteristics of LPG/air lean pre-mixed flames were experimentally investigated using a double and a multiple concentric coflow burners. Experiments were conducted to understand the effects of recirculation motion, thermal interaction between flames, and stratified flame configuration. Here, the stratified premixed flame is a "new concept" of a flame that sequentially contains fuel rich, stoichiometric, and fuel lean reaction zones in a flame. The blow-off from a lean premixed flame was significantly suppressed with recirculation motion. The recirculation motion by itself, however, was not sufficient to prevent the blow-off when the equivalence ratio became low. The existence of a inner premixed flame could also help to prevent the blow-off of lean premixed flame; however, the blow-off suppression effect was rather diminished by weakened recirculation motion with the presence of inner flame. The inner flame could be separated from an outer flame on a multiple concentric coflow burner, causing recirculation motion as well as thermal interaction between flames to become effective; therefore, the blow-off was further suppressed. The lean premixed flame could be stabilized with a fuel rich premixed flames that was produced with the supply of fuel through an inner nozzle. The penetration of lean premixed gas from outside into the fuel stream produced a lifted rich premixed flame. Chemiluminescence images of OH, CH, and $C_2$ radicals confirmed the structure of a stratified premixed flame. The stable premixed flames could be obtained at the very fuel lean condition by applying the stratified premixed flame concept.

Fuel Dilution Effects for Stratified Premixed Flames (성층화된 예혼합화염에 대한 희석제 첨가의 영향)

  • Ahn, Taekook;Lee, Wonnam
    • 한국연소학회:학술대회논문집
    • /
    • 2013.06a
    • /
    • pp.73-76
    • /
    • 2013
  • The inert gas dilution effect for the stability of a stratified propane premixed flame has been experimentally studied. The addition of inert gases to a stratified premixed flame, which used to be very stable without dilution, makes a flame unstable. The lower equivalence ratio on the outer premixed flame and the lower fuel flow rate through the inner nozzle were observed to be the more stable conditions for the stratified premixed flame with nitrogen or argon dilution. It has been interpreted with the flame structure change such as shift of stoichiometric ratio region in a flame.

  • PDF

A Study on the Influence of Equivalence Ratio and Kinds of fuel in Flame Structure (화염 구조에 미치는 연료 및 당량비에 관한 연구)

  • Park, S.K.;Choi, N.J.;Yamashita, H.
    • Journal of ILASS-Korea
    • /
    • v.3 no.4
    • /
    • pp.43-49
    • /
    • 1998
  • In order to clarify the effect of equivalence ratio and kinds of fule in flame structure, a numerical simulation of triple flame developed in a co-flowing methane-air and air stream was carried out by the elementary chemical reaction mechanism. The following conclusions were obtained. Equivalence ratio at which the apparent burning velocity is maximum is a little larger than that of the one-dimensional premixed flame. Apparent burning velocities are two times higher than that of the one-dimensional premixed flame for the methane-air. The flame thrusts out forward in the downstream of the boundary between mixture and air stream, and a part of the flow is bent and forks out in this protruding flame so that a triple flame is originated; this triple flame is composed of fuel rich and lean premixed flame branches and a diffusion flame branch. Near the equivalence ratio at which the burning velocity of rule-dimensional premixed flame is the largest the effect of one-dimensional premixed flame becomes large and the fuel rich premixed flame advances and becomes vertical to the flow direction.

  • PDF

Numerical Study on Non-premixed Methane Flames in Twin-jet Counterflow (Twin-jet 대향류에서 메탄 비예혼합화염에 대한 수치적 연구)

  • Chun, K.W.;Kim, J.H.;Chung, C.H.
    • 한국연소학회:학술대회논문집
    • /
    • 2004.06a
    • /
    • pp.49-56
    • /
    • 2004
  • A two-dimensional twin-jet counterflow system has been designed, in which two streams from two double-slit nozzles form a counterflow. This flow system enables one to systematically investigate various effects on non-premixed flames, including the non-premixed flame interaction, the edge flame behavior and the effect of curvature. Non-premixed flame interaction in the twin-jet counterflow system has been investigated numerically for methane fuel diluted with nitrogen. Three types of non-premixed flame(conventional counterflow flame, crossed twin-jet flame and petal shaped flame) were simulated depending on the combination of fuel/oxidizer supply to each nozzle. The extinction characteristics of non premixed methane flame in the twin-jet counterflow have been investigated numerically. The boundary of the existence of petal-shaped flames was identified for the twin-jet counterflow flames. Due to the existence of the unique petal-shaped flames, the extinction boundary for the twin-jet counterflow can be extended significantly compared to that for the conventional counterflow non-premixed flames, through the interaction of two flames. Through the comparison of the crossed twin-jet flame and the conventional counterflow flame, structure of the crossed twin-jet counterflow flame is analysed. Through the comparison of the petal shaped flame and the conventional counterflow flame, the extension of the extinction boundary for the twin-jet counterflow is investigated.

  • PDF

Extinction of Non-premixed methane Flame in Twin-Jet Counterflow (Twin-Jet 대향류에서 메탄 비예혼합화염의 소염 특성)

  • Noh, T.G.;Yang, S.Y.;Ryu, S.K.;Chung, S.H.
    • 한국연소학회:학술대회논문집
    • /
    • 2003.12a
    • /
    • pp.195-200
    • /
    • 2003
  • A two-dimensional "twin-jet counterflow" burner has been designed for the better understanding of the stability of turbulent flames. This flow system enables one to systematically investigate various effects on non-premixed flames, including the effects of curvature, negative strain, and non-premixed flame interactions. The objective of this study is comparing characteristics of extinction of non-premixed methane flames with that of non-premixed propane flames investigated previously. The extinction limit of non-premixed methane and propane flames can be extended compare to that for the conventional counterflow non-premixed flame because of the existence of petal shaped flame and have same structure. The hysteresis in transition between the petal shaped flame and the curved two-wing flames could be observed. We could find differences between non-premixed methane flame and non-premixe propane flame such as the position of one wing extinction and the regime of one wing extinction.

  • PDF

Experimental Study on the Edge Flame Stabilization and its Structure Nearby Quenching Limits in a High Temperature Channel (고온 채널 내부 에지화염의 소염 한계 영역에서의 화염 안정화 및 구조에 관한 실험적 연구)

  • Lee, Min-Jung;Kim, Nam-Il
    • Journal of the Korean Society of Combustion
    • /
    • v.15 no.3
    • /
    • pp.1-7
    • /
    • 2010
  • Edge flames have been interested as a basic structure that is concerned to flame stabilization and re-ignition of non-premixed flames. The edge flame consists of a lean premixed flame, a rich premixed flame, and a diffusion flame. In order to investigate fundamental structures of the edge flames at the conditions near the flammability limits, edge flames were stabilized within a heated narrow channel. Highly diluted partially premixed methane was used, and the flow rates of air and the partially premixed mixture were controlled. Various flame behaviors, including a transition between ordinary edge flames and premixed flames, were observed. Flame stabilization characteristics were examined as well. All flame stabilization conditions in this study showed a similar trend: characteristic time scales were inversely proportional to the equivalence ratio defined at the burner inlet. Finally, an interesting flame structure having a weak diffusion branch enveloped by a closed premixed branch was found near the flammability limits even in a fuel-air mixing layer. This structure was named as a "flame-drop" and the importance of this structure was first suggested.