• 제목/요약/키워드: Predictive diagnosis

검색결과 491건 처리시간 0.025초

건식 진공펌프의 상태진단 및 예지보수 기법 (Predictive Diagnosis and Preventive Maintenance Technologies for Dry Vacuum Pumps)

  • 정완섭
    • 진공이야기
    • /
    • 제2권1호
    • /
    • pp.31-34
    • /
    • 2015
  • This article introduces fundamentals of self-diagnosis and predictive (or preventive) maintenance technologies for dry vacuum pumps. The state variables of dry pumps are addressed, such as the pump and motor body temperatures, consumption currents of main and booster pumps, mechanical vibration, and exhaust pressure, etc. The adaptive parametric models of the state variables of the dry pump are exploited to provide dramatic reduction of data size and computation time for self-diagnosis. Two indicators, the Hotelling's $T^2$ and the sum of squares residuals (Q), are illustrated to be quite effective and successful in diagnosing dry pumps used in the semiconductor processes.

슬라이딩 모드 관측기를 이용한 기구학 모델 기반 자율주행 자동차의 예견 고장진단 알고리즘 (Kinematic Model based Predictive Fault Diagnosis Algorithm of Autonomous Vehicles Using Sliding Mode Observer)

  • 오광석;이경수
    • 대한기계학회논문집A
    • /
    • 제41권10호
    • /
    • pp.931-940
    • /
    • 2017
  • 본 논문은 슬라이딩 모드 관측기를 이용한 기구학 모델 기반 자율주행 자동차의 예견 고장진단 알고리즘에 관한 연구이다. 자율주행 자동차는 안전한 주행을 위해 신뢰성이 확보된 주행 환경 정보와 차량의 동적상태 정보가 필요하다. 센서 정보의 신뢰성 판단을 위해 본 연구에서는 종방향 기구학 모델기반 슬라이딩모드 관측기를 이용하여 종방향 환경정보와 차량 가속도 정보를 실시간으로 상호 보완적 고장진단이 가능한 예견 알고리즘을 제안하였다. 적용된 슬라이딩 모드 관측기는 종방향 환경정보의 고장신호에도 강건한 입력신호 재건성능을 보이면서 알고리즘의 신뢰성을 확보할 수 있었다. 예견 고장진단 알고리즘의 합리적 성능평가를 위해 네 가지 조건에 대한 실제 주행 데이터 기반 선행차량 추종시나리오를 적용하였다. 성능평가 결과 본 연구에서 제안된 예견 고장진단 알고리즘은 모든 평가조건과 주행 시나리오에 대해 합리적인 고장진단 성능을 보여주었다.

LPC 잔여신호의 에너지를 이용한 회전기기의 고장진단 시스템 (Fault Diagnosis System of Rotating Machines Using LPC Residual Signal Energy)

  • 이성상;조상진;정의필
    • 융합신호처리학회논문지
    • /
    • 제6권3호
    • /
    • pp.143-147
    • /
    • 2005
  • 운전 중인 기계들의 안전 운전과 예지 보전을 위한 설비의 고장 감지 및 진단과 상태감시는 산업 현장에서 중요한 역할을 담당하고 있다. 이러한 설비의 많은 기기들은 회전기기로 이루어져 있으며 회전기기의 고장진단은 오랜 기간 많은 분야에서 연구되고 있다. 본 연구에서는 회전기기의 고장신호는 주파수 영역의 신호의 변화로 나타난다는 특징을 이용하여 보다 효율적인 주파수 영역에서의 신호 해석을 위하여 Linear Predictive Coding(LPC) 계수를 이용하였다. 사용된 데이터는 회전기기의 고장 신호의 습득을 용이하게 하기 위하여 유도전동기에 인위적인 고장재현을 통하여 습득된 진동 신호를 사용하였다. 제안된 시스템은 LPC 분석을 사용하여 일반적으로 사용되는 주파수 영역 상에서의 다른 해석 방법들보다 빠른 시간에 연산 결과를 도출할 수 있는 장점을 가질 수 있었으며, 성공적인 실험 결과를 얻을 수 있었다.

  • PDF

Sensitivity, specificity, and predictive value of cardiac symptoms assessed by emergency medical services providers in the diagnosis of acute myocardial infarction: a multi-center observational study

  • Park, Jeong Ho;Moon, Sung Woo;Kim, Tae Yun;Ro, Young Sun;Cha, Won Chul;Kim, Yu Jin;Shin, Sang Do
    • Clinical and Experimental Emergency Medicine
    • /
    • 제5권4호
    • /
    • pp.264-271
    • /
    • 2018
  • Objective For patients with acute myocardial infarction (AMI), symptoms assessed by emergency medical services (EMS) providers have a critical role in prehospital treatment decisions. The purpose of this study was to evaluate the diagnostic accuracy of EMS provider-assessed cardiac symptoms of AMI. Methods Patients transported by EMS to 4 study hospitals from 2008 to 2012 were included. Using EMS and administrative emergency department databases, patients were stratified according to the presence of EMS-assessed cardiac symptoms and emergency department diagnosis of AMI. Cardiac symptoms were defined as chest pain, dyspnea, palpitations, and syncope. Disproportionate stratified sampling was used, and medical records of sampled patients were reviewed to identify an actual diagnosis of AMI. Using inverse probability weighting, verification bias-corrected diagnostic performance was estimated. Results Overall, 92,353 patients were enrolled in the study. Of these, 13,971 (15.1%) complained of cardiac symptoms to EMS providers. A total of 775 patients were sampled for hospital record review. The sensitivity, specificity, positive predictive value, and negative predictive value of EMS provider-assessed cardiac symptoms for the final diagnosis of AMI was 73.3% (95% confidence interval [CI], 70.8 to 75.7), 85.3% (95% CI, 85.3 to 85.4), 3.9% (95% CI, 3.6 to 4.2), and 99.7% (95% CI, 99.7 to 99.8), respectively. Conclusion We found that EMS provider-assessed cardiac symptoms had moderate sensitivity and high specificity for diagnosis of AMI. EMS policymakers can use these data to evaluate the pertinence of specific prehospital treatment of AMI.

A Study of Performance Monitoring and Diagnosis Method for Multivariable MPC Systems

  • Lee, Seung-Yong;Youm, Seung-Hun;Lee, Kwang-Soon
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2003년도 ICCAS
    • /
    • pp.2612-2616
    • /
    • 2003
  • Method for performance monitoring and diagnosis of a MIMO control system has been studied aiming at application to model predictive control (MPC) for industrial processes. The performance monitoring part is designed on the basis of the traditional SPC/SQC method. To meet the underlying premise of Schwart chart observation that the observed variable should be univariate and independent, the process variables are decorrelated temporally as well as spatially before monitoring. The diagnosis part was designed to identify the root of performance degradation among the controller, process, and disturbance. For this, a method to estimate the model-error and disturbance signal has been devised. The proposed methods were evaluated through numerical examples.

  • PDF

원자로냉각재펌프 예측진단 기술개발 현황 및 추진방안 (The Study of Predictive Diagnosis Technology Development Status and Promotion Plan for Reactor Coolant Pump)

  • 김희찬
    • 한국압력기기공학회 논문집
    • /
    • 제19권1호
    • /
    • pp.44-51
    • /
    • 2023
  • The RCP is one of the main components in nuclear power plants and plays an important role in circulating coolant to the RCS system. Currently, nuclear plants are monitored using various monitoring systems. However, since they operate independently according to their functional purpose, it is not able to analyze vibration and operation/performance information comprehensively, and thus failure diagnosis accuracy is limited. In addition, these systems do not provide some important information (such as fault type, parts and cause) necessary for emergency actions, but provide only alarm information. To improve these technical problems, this study proposes a diagnosis technique (M/L, Rule-based model, Data-driven model, Narrow band model) and methodology for comprehensive analysis.

측두하악관절 장애에 대한 임상진단의 유효성 연구 (EVALUATION OF CLINICAL METHODS IN THE DIAGNOSIS OF TEMPOROMANDIBULAR JOINT DISORDERS: A COMPARISON STUDY WITH MAGNETIC RESONANCE IMAGING)

  • 김형욱;신성수;김종식;김기영;김윤지;홍순민;천세환;박양호;최원철;박준우
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • 제33권4호
    • /
    • pp.367-374
    • /
    • 2007
  • Purpose: The diagnostic relevancies and characteristics and of clinical methods in the diagnosis of internal derangement(ID) were tested by comparing the results of them with those of magnetic resonance imaging(MRI). Methods: 75 patients(150 temporomandibular joints; TMJs), who were suspected to have ID by clinical diagnoses, were included. Clinical diagnoses including mouth opening pathway and TMJ sound were conducted and MRI takings were done. Accuracies, sensitivities, specificities, positive predictive values, and negative predictive values of clinical diagnosis, mouth opening pathway, and TMJ sound were calculated by comparing with diagnoses with MRIs. Results: Accuracy, sensitivity, specificity, positive predictive value, and negative predictive value of clinical diagnosis were 59.3%, 83%, 49%, 81%, and 51%. They were 59%, 82%, 25%, 73%, and 35% for mouth opening pathways. Although deviation was somewhat accurate for representing disc displacement with reduction(ADDWR), other discrepancies on opening pathways were not clinically relevant. Accuracy, sensitivity, specificity, positive predictive value, and negative predictive value of clicking sounds were 85%, 49%, 78%, 85%, and 37%. TMJs with crepitus were only three. But all TMJs with crepitus were diagnosed to have disc displacement without reduction(ADDWOR). Conclusion: When compared with diagnoses with MRIs, clinical diagnoses for ID were not so accurate. But they were suitable for screening tests for ID. Opening pathways and TMJ sounds were not so relevant in the diagnoses of IDs and so it was concluded that considerations for other factors must be included in the diagnoses of IDs.

Fast Diagnosis Method for Submodule Failures in MMCs Based on Improved Incremental Predictive Model of Arm Current

  • Xu, Kunshan;Xie, Shaojun
    • Journal of Power Electronics
    • /
    • 제18권5호
    • /
    • pp.1608-1617
    • /
    • 2018
  • The rapid and correct isolation of faulty submodules (SMs) is of great importance for improving the reliability of modular multilevel converters (MMCs). Therefore, a fast diagnosis method containing fault detection and fault location determination was presented in this paper. An improved incremental predictive model of arm current was proposed to detect failures, and the multi-step prediction method was used to eliminate the negative impact of disturbances. Moreover, a control method was proposed to strengthen the fault characteristics to rapidly locate faulty arms and faulty SMs by detecting the variation rate of the SM capacitor voltage. The proposed method can rapidly and easily locate faulty SMs under different load conditions without the need for additional sensors. The experimental results have validated the effectiveness of the proposed method by using a single-phase MMC with four SMs per arm.

극상근 파열에 대한 Empty Can Test의 진단적 가치 - 관절경 소견과 비교 - (Empty Can Test for Diagnosis of Supraspinatus Tear - Compare with Arthroscopic Finding -)

  • 문영래;유재원;김동휘
    • Clinics in Shoulder and Elbow
    • /
    • 제4권1호
    • /
    • pp.13-16
    • /
    • 2001
  • Object: To determine the sensitivity, specificity, and positive and negative predictive values of an empty can test for diagnosing supraspinatus tendon tear. Methods: We reviewed 146 patients who have shoulder pain with limited active range of motion. We evaluated patients according to empty can test. Sensitivity, specificity, and positive and negative predictive values for supraspinatus test was estimated using arthroscopic evaluation. Results: A hundred and twenty-four of 127 cases with positive empty can test had supraspinatus tendon tear. Of 19 samples with negative empty can test, 15 had no supraspinatus tear. Sensitivity, specificity, and positive and negative predictive values for the empty can test were 97.6%, 83.3%, 97.6%, and 78.9%, respectively. Conclusions: Empty can test was found to have a high sensitivity and good positive predictive value in identifying the tear of rotator cuff tendon. We concluded that empty can test of the shoulder is a reliable diagnostic method which could be used for the diagnosis of rotator cuff tear.

  • PDF

경흉세침흡인 생검에 의한 폐질환의 세포병리학적 진단 (Cytopathologic Diagnosis of Pulmonary Diseases by Transthoracic Fine Needle Aspiration Biopsy)

  • 박인애;함의근
    • 대한세포병리학회지
    • /
    • 제1권1호
    • /
    • pp.27-35
    • /
    • 1990
  • The authors report series of 360 cases of transthoracic fine-needle aspiration cytology (TFNA) from Oct. 1982, through Aug. 1986 at the Seoul National University Hospital. A diagnosis of neoplastic lesion was established in 50.3% of the cases. A non-neoplastic diagnosis was made in 38.5%, nondiagnostic one in 6.5% and inadequate one in 4.7% of the total. Statistical findings on cytological diagnoses were as follows. Specificity was 100% ; sensitivity, 92% ; predictive value for positive, 1.0 ; predictive value for negative, 0.9 ; concordance rate, 84.2% ; diagnostic accuracy in non-neoplastic lesion, 65.4%, and typing accuracy in malignant tumor, 0.77.

  • PDF