• 제목/요약/키워드: Predictive Value (PPV)

검색결과 91건 처리시간 0.024초

Efficacy of Pap Test in Combination with ThinPrep Cytological Test in Screening for Cervical Cancer

  • Chen, Hua;Shu, Hui-Min;Chang, Zhou-Lin;Wang, Zhi-Feng;Yao, Hai-Hong;Zhu, Hong-Mei;Lu, Tian-Mei;Ma, Qiang-Yan;Yang, Bin-Lie
    • Asian Pacific Journal of Cancer Prevention
    • /
    • 제13권4호
    • /
    • pp.1651-1655
    • /
    • 2012
  • Background: Our aim was to investigate the efficacy of the Pap test in combination with the ThinPrep cytological test (TCT) in screening for cervical cancer in China. Design: From March 2006 to October 2008, 988 women with the mean age $46.4{\pm}10.5$ years (range, 23-80 years) were recruited to receive cervical cancer screening. Pap test results ${\geq}$ grade III and TCT findings ${\geq}$ ASCUS/AGUS were considered abnormal. Subjects with a Pap test result ${\geq}$ grade IIb received TCT. Colposcopy and biopsies were performed in all participants, and final diagnosis was based on pathological findings. The sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV) and Youden index for predicting CIN I or above were determined. Results: The sensitivity, specificity, PPV, NPV and Youden index of the Pap test were 43.1%, 97.2%, 70.0%, 91.9%, and 40.3%, respectively. The same values for TCT in predicting CIN were 80.0%, 63.2%, 16.0%, 97.3%, and 43.2%, respectively. The two tests in combination gave values for predicting CIN of 64.8%, 87.6%, 43.6%, 94.4%, and 53.5%, respectively. Combined testing exhibited the highest Youden index (53.4%). Conclusion: The Pap test with a reduced threshold in combination with the TCT has high sensitivity and high specificity in screening for cervical cancer.

Accuracy of Self-Checked Fecal Occult Blood Testing for Colorectal Cancer in Thai Patients

  • Lohsiriwat, Varut
    • Asian Pacific Journal of Cancer Prevention
    • /
    • 제15권18호
    • /
    • pp.7981-7984
    • /
    • 2014
  • Purpose: Colorectal cancer (CRC) screening with fecal occult blood testing (FOBT) has been associated with a reduction in CRC incidence and CRC-related mortality. However, a conventional FOBT requires stool collection and handling, which may be inconvenient for participants. The EZ-Detect$^{TM}$ (Siam Pharmaceutical Thailand) is a FDA-approved chromogen-substrate based FOBT which is basically a self-checked FOBT (no stool handling required). This study aimed to evaluate the accuracy of EZ-Detect for CRC detection. Methods: This prospective study was conducted in the Faculty of Medicine, Siriraj Hospital, Bangkok, Thailand between November 2013 and May 2014. Some 96 patients with histologically-proven CRC and 101 patients with normal colonoscopic findings were invited to perform self-checked FOBT according to the manufacturer's instructions. Results were compared with endoscopic and pathologic findings. Sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) for CRC detection were calculated. Results: The present study revealed the sensitivity, specificity, PPV and NPV of this self-checked FOBT for CRC detection to be 41% (95% CI: 31-51), 97% (95% CI: 92-99), 93% (95% CI: 81-98) and 63% (95% CI: 55-70), respectively. The overall accuracy of the self-checked FOBT for identifying CRC was 70%. The sensitivity for CRC detection based on 7th AJCC staging was 29% for stage I, 32% for stage II and 50% for stage III/IV (P=0.19). The sensitivity was 33% for proximal colon and 42% for distal colon and rectal cancer (P=0.76). Notably, none of nine infiltrative lesions gave a positive FOBT. Conclusions: The self-checked FOBT had an acceptable accuracy of CRC detection except for infiltrative tumors. This home-administrated or 'DIY' do-it-yourself FOBT could be considered as one non-invasive and convenient tool for CRC screening.

Utility of Frozen Section Pathology with Endometrial Pre-Malignant Lesions

  • Oz, Murat;Ozgu, Emre;Korkmaz, Elmas;Bayramoglu, Hatice;Erkaya, Salim;Gungor, Tayfun
    • Asian Pacific Journal of Cancer Prevention
    • /
    • 제15권15호
    • /
    • pp.6053-6057
    • /
    • 2014
  • Aim: To determine utility of the frozen section (FS) in the operative management of endometrial pre-malignant lesions. Materials and Methods: We retrospectively analyzed patients who underwent abdominal hysterectomy with preoperative diagnosis of complex atypical endometrial hyperplasia (CAEH) and simple endometrial hyperplasia (SEH) between May 2007 and December 2013. Frozen and paraffin section (PS) results were compared. Sensitivity, specificity, the positive predictive value (PPV), the negative predictive value (NPV) and the accuracy in predicting EC on FS were evaluated with 95% confidence intervals (CIs) for each parameter. The correlation between FS and PS was calculated as an ${\kappa}$ coefficient. Results: Among 143 preoperatively diagnosed CAEH cases, 60 (42%) were malignant and 83 (58%) were benign in PS; and among 60 malignant cases diagnosed in PS, 43 (71%) were "malignant" in FS. Sensitivity, specificity, PPV and NPV for FS were 76%, 100%, 100% and 87.5%, respectively. Conclusions: We found that FS is reliable and applicable in the management of endometrial hyperplasias. It is important that the pathologist should be experienced because FS for endometrial pre-malignant lesions has significant inter-observer variability. The other conclusion is that patients with the diagnosis of EH, especially those who are postmenopausal, should undergo surgery where FS investigation is available.

Evaluation of the Atlas Helicobacter pylori Stool Antigen Test for Diagnosis of Infection in Adult Patients

  • Osman, Hussein Ali;Hasan, Habsah;Suppian, Rapeah;Bahar, Norhaniza;Che Hussin, Nurzam Suhaila;Rahim, Amry Abdul;Hassan, Syed;Andee, Dzulkarnaen Zakaria;Zilfalil, Bin-Alwi
    • Asian Pacific Journal of Cancer Prevention
    • /
    • 제15권13호
    • /
    • pp.5245-5247
    • /
    • 2014
  • Background: Helicobacter pylori (H.pylori) is one of the most important causes of dyspepsia and gastric cancer and diagnosis can be made by invasive or non-invasive methods. The Atlas Helicobacter pylori antigen test is a new rapid non-invasive method which is simple to conduct. The aim of this study was to determine its sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV) and accuracy. Materials and Methods: This prospective study was conducted between July 2012 and December 2013. Stool samples of 59 dyspeptic patients who underwent upper endoscopy were evaluated for H. pylori stool antigen. Results: From the 59 patients who participated in this study, there were 36 (61%) males and 23 (39%) females. H. pylori was diagnosed in 24 (40.7%) gastric biopsies, 22 (91.7 %) of these being positive for the Atlas H. pylori antigen test. The sensitivity, specificity, PPV, NPV and accuracy were 91.7%, 100%, 100%, 94.6% and 96.6% respectively. Conclusions: The Atlas H. pylori antigen test is a new non-invasive method which is simple to perform and avails reliable results in a few minutes. Thus it can be the best option for the diagnosis of H. pylori infection due to its high sensitivity and specificity.

미국표준연구원 체크리스트 Z-365의 자가보고형 설문개발 및 타당도 평가 (Development of Self Administered Questionnaire and Validity Evaluation for American National Standards Z-365 Checklist)

  • 박경식;강동묵;이용환;우지훈;신용철
    • 한국산업보건학회지
    • /
    • 제16권2호
    • /
    • pp.172-182
    • /
    • 2006
  • Self administered checklist is needed to be developed to evaluate ergonomic risk factors. This study was conducted to develop self administered form of American National Standards Institute (ANSI) Z-365 checklist which represents comprehensive ergonomic risk factors, and to evaluate validity of this checklist. This study had been conducted from May 2004 to July 2005, of which subjects were 147 workers from 4 workplaces. Response rates for every items of self administered form of ANSI Z-365 were evaluated. To estimate the validity of checklist, relationship between the checklist grade that ANSI recommended and work-related musculoskeletal disorders (WMSDs) symptom were calculated with and without adjustment of related variables. To evaluate the utility of checklist, sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) were calculated. Because response rates of almost items were over 90 %, item development was successful. Because the checklist was related with WMSDs symptom after adjusting related variables, the checklist might represents ergonomic risk well. Because of low sensitivity and NPV, high specificity and PPV, the checklist is not suitable for screening tool. The checklist has better relationship with more severe symptom. Because of high specificity of the checklist, using it with high sensitive tool would enhance it's utility. Further study to develop high sensitive and comprehensive self administered ergonomic checklist is needed.

Comparison of two computerized occlusal analysis systems for indicating occlusal contacts

  • Jeong, Min-Young;Lim, Young-Jun;Kim, Myung-Joo;Kwon, Ho-Beom
    • The Journal of Advanced Prosthodontics
    • /
    • 제12권2호
    • /
    • pp.49-54
    • /
    • 2020
  • PURPOSE. The purpose of this study was to compare the performance of Accura to that of the T-scan for indicating occlusal contacts. MATERIALS AND METHODS. Twenty-four subjects were selected. Their maxillary dental casts were scanned with a model scanner. The Stereolithography files of the casts were positioned to align with the occlusal plane. Occlusal surfaces of every tooth were divided into three to six anatomic regions. T-scan and Accura recordings were made during two masticatory cycles. The T-scan and Accura images were captured at the maximum bite force and overlapped to the cast. Photographs of interocclusal records were used as the reference during overlap. The occlusal contacts were counted to compare the T-scan and Accura. McNemar's test was used for statistical significance and the corresponding P-values were calculated from a chi-square distribution with one degree of freedom. The accuracy, sensitivity, specificity, positive predictive value (PPV) and negative predictive value (NPV) of Accura were calculated relative to the T-scan values as a control. RESULTS. No statistical differences (P>.05) were found between the T-scan and Accura methods. The accuracy of Accura was 75.8%, sensitivity was 82.1%, specificity was 60.1%, PPV was 82.9%, and NPV was 60.1%. CONCLUSION. Accura could be another possible option as a computerized occlusal analysis system for indicating occlusal contacts at maximum intercuspation.

Validation of Administrative Big Database for Colorectal Cancer Searched by International Classification of Disease 10th Codes in Korean: A Retrospective Big-cohort Study

  • Hwang, Young-Jae;Kim, Nayoung;Yun, Chang Yong;Yoon, Hyuk;Shin, Cheol Min;Park, Young Soo;Son, Il Tae;Oh, Heung-Kwon;Kim, Duck-Woo;Kang, Sung-Bum;Lee, Hye Seung;Park, Seon Mee;Lee, Dong Ho
    • Journal of Cancer Prevention
    • /
    • 제23권4호
    • /
    • pp.183-190
    • /
    • 2018
  • Background: As the number of big-cohort studies increases, validation becomes increasingly more important. We aimed to validate administrative database categorized as colorectal cancer (CRC) by the International Classification of Disease (ICD) 10th code. Methods: Big-cohort was collected from Clinical Data Warehouse using ICD 10th codes from May 1, 2003 to November 30, 2016 at Seoul National University Bundang Hospital. The patients in the study group had been diagnosed with cancer and were recorded in the ICD 10th code of CRC by the National Health Insurance Service. Subjects with codes of inflammatory bowel disease or tuberculosis colitis were selected for the control group. For the accuracy of registered CRC codes (C18-21), the chart, imaging results, and pathologic findings were examined by two reviewers. Sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) for CRC were calculated. Results: A total of 6,780 subjects with CRC and 1,899 control subjects were enrolled. Of these patients, 22 subjects did not have evidence of CRC by colonoscopy, computed tomography, magnetic resonance imaging, or positron emission tomography. The sensitivity and specificity of hospitalization data for identifying CRC were 100.00% and 98.86%, respectively. PPV and NPV were 99.68% and 100.00%, respectively. Conclusions: The big-cohort database using the ICD 10th code for CRC appears to be accurate.

Contrast-Enhanced Spectral Mammography Versus Ultrasonography: Diagnostic Performance in Symptomatic Patients with Dense Breasts

  • Zhongfei Lu;Cuijuan Hao;Yan Pan;Ning Mao;Xin Wang;Xundi Yin
    • Korean Journal of Radiology
    • /
    • 제21권4호
    • /
    • pp.442-449
    • /
    • 2020
  • Objective: To compare the diagnostic performance of contrast-enhanced spectral mammography (CESM) versus ultrasonography (US) in symptomatic patients with dense breasts, while using histology as the gold standard. Materials and Methods: After obtaining approval from the local ethics board, this prospective study collected data from patients with symptomatic breasts who underwent CESM and US examinations from May 1, 2017 to September 30, 2017. We then selected those with dense breasts and pathological results as our sample population. Both CESM and US results were classified by a radiologist through the Breast Imaging Reporting and Data System, and the results were compared with their corresponding histological results. The chi-square test was conducted to compare the diagnostic performance of CESM and US, and the receiver operating characteristic curves for the two imaging modalities were obtained. Results: A total of 131 lesions from 115 patients with dense breasts were included in this study. Sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV), and accuracy were 93.8%, 88.1%, 88.2%, 93.7%, and 90.8% for CESM, and 90.6%, 82.1%, 82.9%, 90.2%, and 86.3% for US, respectively. The p values for sensitivity, specificity, PPV, NPV, and accuracy were 0.687, 0.388, 0.370, 0.702, and 0.238, respectively. The area under the curve of CESM (0.917) was comparable with that of US (0.884); however, the differences between CESM and US were not statistically significant (p = 0.225). Eight false-positive cases and 4 false-negative cases for breast cancer were found in CESM, while 12 false-positive cases and 6 false-negative cases were found in US. Conclusion: The diagnostic performances of CESM and US are comparable in symptomatic women with dense breasts; however, the routine use of additional US imaging is questionable for lesions that can be detected by CESM.

Cone-Beam CT-Guided Percutaneous Transthoracic Needle Lung Biopsy of Juxtaphrenic Lesions: Diagnostic Accuracy and Complications

  • Wonju Hong;Soon Ho Yoon;Jin Mo Goo;Chang Min Park
    • Korean Journal of Radiology
    • /
    • 제22권7호
    • /
    • pp.1203-1212
    • /
    • 2021
  • Objective: To investigate the diagnostic accuracy and complications of cone-beam CT-guided percutaneous transthoracic needle biopsy (PTNB) of juxtaphrenic lesions and identify the risk factors for diagnostic failure and complications. Materials and Methods: In total, 336 PTNB procedures for lung lesions (mean size ± standard deviation [SD], 4.3 ± 2.3 cm) abutting the diaphragm in 326 patients (189 male and 137 female; mean age ± SD, 65.2 ± 11.4 years) performed between January 2010 and December 2014 were included. The accuracy, sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) of the PTNB procedures for the diagnosis of malignancy were measured based on the intention-to-diagnose principle. The risk factors for diagnostic failures and complications were evaluated using logistic regression analysis. Results: The accuracy, sensitivity, specificity, PPV, and NPV were 92.7% (293/316), 91.3% (219/240), 91.4% (74/81), 96.9% (219/226), and 77.9% (74/95), respectively. There were 23 diagnostic failures (7.3%), and lesion sizes ≤ 2 cm (p = 0.045) were the only significant risk factors for diagnostic failure. Complications occurred in 98 cases (29.2%), including 89 cases of pneumothorax (26.5%) and 7 cases of hemoptysis (2.1%). The multivariable analysis showed that old age (> 65 years) (p = 0.002), lesion size of ≤ 2 cm (p = 0.003), emphysema (p = 0.006), and distance from the pleura to the target lesion (> 2 cm) (p = 0.010) were significant risk factors for complications. Conclusion: The diagnostic accuracy of cone-beam CT-guided PTNB of juxtaphrenic lesions for malignancy was fairly high, and the target lesion size was the only significant predictor of diagnostic failure. Complications of cone-beam CT-guided PTNB of juxtaphrenic lesions occurred at a reasonable rate.

Modification of HEART Pathway for Patients With Chest Pain: A Korean Perspective

  • Bora Chae;Shin Ahn;Youn-Jung Kim;Seung Mok Ryoo;Chang Hwan Sohn;Dong-Woo Seo;Won Young Kim
    • Korean Circulation Journal
    • /
    • 제53권9호
    • /
    • pp.635-644
    • /
    • 2023
  • Background and Objectives: The History, Electrocardiography, Age, Risk factors, and Troponin (HEART) pathway was developed to identify patients at low risk of a major adverse cardiac event (MACE) among patients presenting with chest pain to the emergency department. Methods: We modified the HEART pathway by replacing the Korean cut-off of 25 kg/m2 with the conventional threshold of 30 kg/m2 in the definition of obesity among risk factors. The primary outcome was a MACE within 30 days, which included acute myocardial infarction, primary coronary intervention, coronary artery bypass grafting, and all-cause death. Results: Of the 1,304 patients prospectively enrolled, MACE occurred in 320 (24.5%). The modified HEART pathway identified 37.3% of patients as low-risk compared with 38.3% using the HEART pathway. Of the 500 patients classified as low-risk with HEART pathway, 8 (1.6%) experienced MACE, and of the 486 low-risk patients with modified HEART pathway, 4 (0.8%) experienced MACE. The modified HEART pathway had a sensitivity of 98.8%, a negative predictive value (NPV) of 99.2%, a specificity of 49.0%, and a positive predictive value (PPV) of 38.6%, compared with the original HEART pathway, with a sensitivity of 97.5%, a NPV of 98.4%, a specificity of 50.0%, and a PPV of 38.8%. Conclusions: When applied to Korean population, modified HEART pathway could identify patients safe for early discharge more accurately by using body mass index cut-off levels suggested for Koreans.