• Title/Summary/Keyword: Predictive Transmission

Search Result 56, Processing Time 0.02 seconds

NCS using the predictive strategy (예측기법을 이용한 NCS)

  • Kim, Jin-Hwan
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.51 no.4
    • /
    • pp.206-210
    • /
    • 2002
  • The transmission delays in the networked control systems affect the performance and stability. For covering the delays, this paper proposes NCS including the predictive strategy. The proposed method shows that the two cases such as stable and unstable system are well behaved.

Transmission Characteristics LonWorks/IP-based Virtual Device Network for Predictive Maintenance (예지보전을 위한 LonWorks/IP 가상 디바이스 네트워크의 통신특성에 관한 연구)

  • Choi, Gi-Heung
    • Journal of the Korean Society of Safety
    • /
    • v.17 no.4
    • /
    • pp.196-201
    • /
    • 2002
  • Web-based predictive maintenance (PM) utilizes Virtual Device Network (VDN). VDN inevitably the implementation of Distributed Monitoring and Control Networks (DMCN). In general, one needs to integrate fieldbus protocol and TCP/IP to realize DMCN over IP network or internet, which can be viewed as Virtual Device Network (VDN). Interoperability between devices and equipments is essential to enhance the quality and the performance of predictive maintenance (PM). This paper investigates the transmission characteristics of VDN and suggests a basic framework for web-based PM using DMCN over IP network.

Duty Ratio Predictive Control Scheme for Digital Control of DC-DC Switching Converters

  • Sun, Pengju;Zhou, Luowei
    • Journal of Power Electronics
    • /
    • v.11 no.2
    • /
    • pp.156-162
    • /
    • 2011
  • The control loop time delay caused by sampling, the zero-order-holder effect and calculations is inevitable in the digital control of dc-dc switching converters. The time delay will limit the bandwidth of the control loop and therefore degrade the transient performance of digital systems. In this paper, the quantization time delay effects with different time delay values based on a generic second-order system are analyzed. The conclusion that the bandwidth of digital control is reduced by about 20% with a one cycle delay and by 50% with two cycles of delay in comparison with no time delay is obtained. To compensate the time delay and to increase the control loop bandwidth, a duty ratio predictive control scheme based on linear extrapolation is proposed. The compensation effect and a comparison of the load variation transient response characteristics with analogy control, conventional digital control and duty ratio predictive control with different time delay values are performed on a point-of-load Buck converter by simulations and experiments. It is shown that, using the proposed technique, the control loop bandwidth can be increased by 50% for a one cycle delay and 48.2% for two cycles of delay when compared to conventional digital control. Simulations and experimental results prove the validity of the conclusion of the quantization effects of the time delay and the proposed control scheme.

Deadbeat and Hierarchical Predictive Control with Space-Vector Modulation for Three-Phase Five-Level Nested Neutral Point Piloted Converters

  • Li, Junjie;Chang, Xiangyu;Yang, Dirui;Liu, Yunlong;Jiang, Jianguo
    • Journal of Power Electronics
    • /
    • v.18 no.6
    • /
    • pp.1791-1804
    • /
    • 2018
  • To achieve a fast dynamic response and to solve the multi-objective control problems of the output currents, capacitor voltages and system constraints, this paper proposes a deadbeat and hierarchical predictive control with space-vector modulation (DB-HPC-SVM) for five-level nested neutral point piloted (NNPP) converters. First, deadbeat control (DBC) is adopted to track the reference currents by calculating the deadbeat reference voltage vector (DB-RVV). After that, all of the candidate switching sequences that synthesize the DB-RVV are obtained by using the fast SVM principle. Furthermore, according to the redundancies of the switch combination and switching sequence, a hierarchical model predictive control (MPC) is presented to select the optimal switch combination (OSC) and optimal switching sequence (OSS). The proposed DB-HPC-SVM maintains the advantages of DBC and SVM, such as fast dynamic response, zero steady-state error and fixed switching frequency, and combines the characteristics of MPC, such as multi-objective control and simple inclusion of constraints. Finally, comparative simulation and experimental results of a five-level NNPP converter verify the correctness of the proposed DB-HPC-SVM.

Improvement of Predictive and Corrective Inspection Methods to Control Nosema bombycis Infection in the Silkworm, Bombyx mori

  • Nguyen, Mau-Tuan;Jon
    • Journal of Sericultural and Entomological Science
    • /
    • v.39 no.2
    • /
    • pp.146-153
    • /
    • 1997
  • The microsporidian infection with Nosema bombycis, reconfirmed its high virulence and transovarial tranmissibility, however, the characteristic symptom of the spots like pepper grains on the diseased larval skin was no more recognized by present varieties of the silkworm. Transovarial transmission rate detected from moth was above 90% in dead eggs or dead larvae in the rearing by mulberry leaves, 80% in the newly hatched larvae starved to death. Transovarially transmitted N. bombycis was easily observed from dead eggs and larvae, and were suggested an individual inspection of a few of dead eggs for detection of the pathogenic spores. The progeny population provided indicative factors on the sampling of predictive and corrective inspection. The higher concentration of N. bombycis spores included in the hindabdormal part of infected moth, applicative on the simple method of indivisual moth inspection. For the predictive inspection of growned 5th-instar larvae, N. bombycis infection was detectable without microscopic observation by the unique symptom of turbid milky-white spots on the silk gland. Inspection of the meconia artificially discharged from silkworm moth, was also succesful of microscopic observation before crossing, without killing or homogenize the moths. The results provided a basis of rational methods for the inspection of N. bombycis infection of the silkworm.

  • PDF

Distributed Control of DC Servo Motor on LonWorks-IP Virtual Device Network for Predictive and Preventive Maintenance (LonWorks-IP 가상 디바이스 네트워크상에서 예지 및 예방보전을 위한 DC 서보모터의 분산제어)

  • Song, Ki-Won
    • Journal of the Korean Society of Safety
    • /
    • v.21 no.4 s.76
    • /
    • pp.25-32
    • /
    • 2006
  • LonWorks over IP(LonWorks-IP) virtual device network(VDN) is an integrated form of LonWorks device network and IP data network. In especially real-time distributed servo applications on the factory floor, timely response is essential for predictive and preventive maintenance. The time delay in servo control on LonWorks-IP based VDN has highly stochastic nature. LonWorks-IP based VDN induced transmission delay deteriorates the performance and stability of the real-time distributed control system and can't give an effective preventive and predictive maintenance. In order to guarantee the stability and performance of the system, and give an effective preventive and predictive maintenance, LonWorks-IP based VDN induced time-varying uncertain time delay needs to be predicted and compensated. In this paper new Pill control scheme based on Smith predictor, disturbance observer and band pass filter is proposed and tested through computer simulation about position control of DC servo motor. It is shown that how can the proposed control scheme be designed to minimize the effects of uncertain varying time delay and model uncertainties. The validity of the proposed control scheme is compared and demonstrated with the comparison of internal model controllers(IMC) based on Smith predictor with and without disturbance observer.

Predictive Current Control of Distribution Static Condenser (D-STATCON) for Reactive Power Compensation in Flexible AC Transmission System(FACTS) (유연송전시스템에서의 역률 보상을 위한 배전용 정지형 동기조상기의 전류제어)

  • 오관일;문건우;전영수;이기선;추진부
    • Proceedings of the KIPE Conference
    • /
    • 1998.07a
    • /
    • pp.447-454
    • /
    • 1998
  • This paper describes a modeling and current control techniques of Distribution static condenser (D-STATCON) for power factor compensation. The current control is based on the predictive and the space vector PWM scheme. The predictive current controlled PWM D-STATCON can maintain its performance with power factor compensation and fixed switching frequency. By using the space vector control low ripple and offset in the current and the voltage as well as fast dynamic responses are achieved with a small DC link capacitance employed.

  • PDF

Analysis on Motion Responses and Transmission Coefficients of a Moored Floating Breakwater in Oblique Incident Waves (경사 입사파중 계류된 부유식 방파제의 운동응답과 투과율 해석)

  • Cho, Il-Hyoung;Pyo, Sang-Woo
    • Journal of Ocean Engineering and Technology
    • /
    • v.23 no.3
    • /
    • pp.6-13
    • /
    • 2009
  • Based on the boundary element method, the motion responses and transmission coefficients of a moored floating breakwater were investigated in oblique waves. To satisfy the outgoing radiation condition in the far field, the fluid domain was divided into inner and outer regions. The complete solution could be obtained by applying the matching conditions between the eigenfunction-based outer solution and BEM-based inner solution. Using the developed predictive tools, the wave exciting forces, added mass, damping coefficients, motion responses, and transmission coefficients were assessed for various combinations of breakwater configuration, wave heading, mooring cables properties, and wave characteristics. It was found that the transmission coefficient for a moored floating breakwater was closely dependent on the motion responses, which were greatly amplified at the resonant frequencies.

Sensory Feedback for High Dissymmetric Master-Slave Dexterity

  • Cotsaftis, Michel;Keskinen, Erno
    • Transactions on Control, Automation and Systems Engineering
    • /
    • v.4 no.1
    • /
    • pp.38-42
    • /
    • 2002
  • Conditions are discussed for operating a dissymmetric human master-small (or micro) slave system in best (large position gain-small velocity gain) conditions allowing higher operator dexterity when real effects (joint compliance, link flexion delay and transmission distortion) are taken into account. It is shown that position PD feedback law advantage for ideal case no longer holds, and that more complicated feedback law depending on real effects has to be implemented with adapted transmission line. Drawback is slowdown of master slave interaction, suggesting to use more advanced predictive methods for the master and more intelligent control law for the slave.

Feasibility study of Predictive Condition Monitoring for High Power Semi-Automatic Transmission by On-Line Wear Monitoring (실시간 마모진단에 의한 고출력 반자동 변속기 예측진단 연구)

  • 정동윤;구석모;윤의성;한흥구;공허성
    • Proceedings of the Korean Society of Tribologists and Lubrication Engineers Conference
    • /
    • 1998.10a
    • /
    • pp.11-16
    • /
    • 1998
  • Condition monitoring technique used in the military is JOAP, for which the spectroscopic analysis is applied. However it is known that the technique has some problems in economical and practical point of view. This study introduces a new technique for measuring wear in real time base and applies the technique to a high power semi-automatic transmission. The results show the feasibility by measuring the concentration of ferrous wear particles from the transmission oil.

  • PDF