• Title/Summary/Keyword: Predicted power

Search Result 1,302, Processing Time 0.033 seconds

Prediction of Physical Examination Demand Using Text Mining (텍스트 마이닝을 이용한 건강검진 수요 예측)

  • Park, Kyungbo;Kim, Mi Ryang
    • Journal of Information Technology Services
    • /
    • v.21 no.5
    • /
    • pp.95-106
    • /
    • 2022
  • Recently, physical examinations have become an important strategy to reduce costs for individuals and society. Pre-physical counseling is important for an effective physical examination. However, incomplete counseling is being conducted because the demand for physical examinations is not predicted. Therefore, in this study, the demand for physical examination was predicted using text mining and stepwise regression. As a result of the analysis, the most recent text data showed a high explanatory power of the demand for physical examination. Also, large amounts of data have high explanatory power. In addition, it was found that the high frequency of the text "health food" reduces the number of health examination customers. And the higher the frequency of the text of the word "food", the lower the number of physical examination customers. However, when the word "wild ginseng" was exposed a lot on Twitter, the number of physical examination customers visiting hospitals increased. In other words, customers consume efficiently by comparing the health examination price with the price of consumer goods. The proposed research framework can help predict demand in other industries.

Comparison of Radionuclide Inventory Between Predicted and Measured Activity of Dry Active Waste From Korea Nuclear Power Plant (국내 원자력발전소 잡고체폐기물의 예측방사능량과 실측방사능량의 비교분석)

  • Jung, Kang Il;Kim, Jin Hyeong;Jeong, Noh Gyeom;Park, Jin Beak
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.15 no.3
    • /
    • pp.281-299
    • /
    • 2017
  • The inventory management of radionuclides is essential for the safe management of disposal facilities. In this study, we compared the activity of dry active waste predicted using the generated waste data and that measured for the accepted waste in the disposal facility. For very low level waste, the measured activity was higher than the predicted activity for $^{137}CS$, $^{90}Sr$, $^{99}Tc$ and $^{129}I$. In low level waste, the predicted activity was higher than the measured activity for all radionuclides. We also evaluated the variation in the predicted quantity and total activity of each level of dry active waste through a sensitivity analysis on a scaling factor. This result will contribute to the construction of a Safety Case and safe operation of disposal facilities.

Demand Forecasts Analysis of Electric Vehicles for Apartment in 2020 (2020년 아파트의 전기자동차 수요예측 분석 연구)

  • Byun, Wan-Hee;Lee, Ki-Hong;Lee, Sang-Hyuk;Kee, Ho-Young
    • The Journal of The Korea Institute of Intelligent Transport Systems
    • /
    • v.11 no.3
    • /
    • pp.81-91
    • /
    • 2012
  • The world has been replacing fast fossil fuels vehicles with electric vehicles(EVs) to cope with climate change. The government set a goal which EVs will be substitute at least 10% of the domestic small vehicles with EVs until 2020, and will try to build electric charging infrastructures in apartments with the revision the law of 'the housing construction standards'. In apartments the EVs charging infrastructure and parking space is, essential to accomplish the goal. But the studies on EVs demand are few. In this study, we predicted that the demand for EVs using time-series analysis of statistical data, survey results for apartments residents in the metropolitan area. As a result, the ratio of the EVs appeared to be 6~21% for the total vehicles in a rental apartments for the years 2020, 21~39% in apartments for sales. For the EVs, the maximum power required for 1,000 households in rental apartment is predicted to be about 4200 kwh on a daily basis, while the maximum power in the apartment for sales is predicted to be 7800kwh.

A LSTM Based Method for Photovoltaic Power Prediction in Peak Times Without Future Meteorological Information (미래 기상정보를 사용하지 않는 LSTM 기반의 피크시간 태양광 발전량 예측 기법)

  • Lee, Donghun;Kim, Kwanho
    • The Journal of Society for e-Business Studies
    • /
    • v.24 no.4
    • /
    • pp.119-133
    • /
    • 2019
  • Recently, the importance prediction of photovoltaic power (PV) is considered as an essential function for scheduling adjustments, deciding on storage size, and overall planning for stable operation of PV facility systems. In particular, since most of PV power is generated in peak time, PV power prediction in a peak time is required for the PV system operators that enable to maximize revenue and sustainable electricity quantity. Moreover, Prediction of the PV power output in peak time without meteorological information such as solar radiation, cloudiness, the temperature is considered a challenging problem because it has limitations that the PV power was predicted by using predicted uncertain meteorological information in a wide range of areas in previous studies. Therefore, this paper proposes the LSTM (Long-Short Term Memory) based the PV power prediction model only using the meteorological, seasonal, and the before the obtained PV power before peak time. In this paper, the experiment results based on the proposed model using the real-world data shows the superior performance, which showed a positive impact on improving the PV power in a peak time forecast performance targeted in this study.

Smart EVs Charging Scheme for Load Leveling Considering ToU Price and Actual Data

  • Kim, Jun-Hyeok;Kim, Chul-Hwan
    • Journal of Electrical Engineering and Technology
    • /
    • v.12 no.1
    • /
    • pp.1-10
    • /
    • 2017
  • With the current global need for eco-friendly energies, the large scale use of Electric Vehicles (EVs) is predicted. However, the need to frequently charge EVs to an electrical power system involves risks such as rapid increase of demand power. Therefore, in this paper, we propose a practical smart EV charging scheme considering a Time-of-Use (ToU) price to prevent the rapid increase of demand power and provide load leveling function. For a more practical analysis, we conduct simulations based on the actual distribution system and driving patterns in the Republic of Korea. Results show that the proposed method provides a proper load leveling function while preventing a rapid increase of demand power of the system.

Hybrid-Type Active Power Filters for Compensating Harmonic Current and Unbalanced Source Voltages (고조파 전류와 불평형 전원전압 보상을 위한 복합형 능동전력 필터)

  • Lee, Ji-Myeong;Lee, Dong-Chun
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.51 no.5
    • /
    • pp.249-257
    • /
    • 2002
  • In this paper, a novel control scheme compensating source voltage unbalance and harmonic currents for the combined system of series active and shunt passive power filter is proposed, where no low/high-pass filters are used in deriving the reference voltage for compensation. The phase angle and the reference voltages compensating for harmonic current and unbalanced voltage are derived from the positive sequence component of the unbalanced voltage set, which is simply obtained by using digital all-pass filters. In order to remove the phase delay in generating the reference voltage for compensation, the reference of 5th and 7th harmonic components is predicted one-sampling ahead. The validity of the proposed scheme has been verified for 3[kVA] proto-type active power filter system.

Design of Microwave Unequal Power Dividers Using Defected Ground Structure (결함접지구조를 이용한 초고주파 비대칭 전력 분배기 설계)

  • Lim, Jong-Sik;Koo, Jae-Jin;Oh, Seong-Min;Ahn, Dal;Choi, Kwan-Sun
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.56 no.6
    • /
    • pp.1099-1104
    • /
    • 2007
  • A 1:6 Unequal 2-way Wilkinson power divider is proposed. The required microstrip line with $207{\Omega}$ characteristic impedance for 1:6 power divider is realized by adding defected ground structure (DGS) to the standard microstrip line. The adopted DGS has the rectangular geometry which results in the increased characteristic impedance. The rectangular-shaped DGS produces the transmission line having much higher characteristic impedance due to the increased equivalent inductance. The measured performances of the fabricated 1:6 power divider show the expected S-parameters with a good agreement with the predicted ones.

Experimental Study On Power Flow Analysis of Vibration of a Coupled Plate (연성 평판 진동에 대한 파워흐름해석법의 실험적 연구)

  • Lee, G.H.;Kil, H.G.;Hwang, S.G.;Hong, S.Y.
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2006.11a
    • /
    • pp.797-800
    • /
    • 2006
  • The power flow analysis(PFA) can be effectively used to predict structural vibration in medium-to-high frequency ranges. In this paper, vibration experiment has been performed to observe the analytical characteristics of the power flow analysis of the vibration of a plate. In the experiment, the loss factor of the plate and the input mobility at a source point have been measured. The data for the loss factor has been used as the input data to predict the vibration of the plate with PFA. The frequency response functions have been measured over the surface of the plate. The comparison between the experimental results and the predicted results for the frequency responsefunctionshasbeenperformed.

  • PDF

Analysis on the Effects of the Induced Noise Voltage with the Grounded or Non-grounded Cable Sheath in the Power Inducting Situation (전력 유도 발생 시 케이블 쉬스 접지 여부에 따른 유도 잡음 전압 영향 분석)

  • Lee, Sang-Mu;Choi, Mun-Hwan;Cho, Pyoung-Dong
    • 한국정보통신설비학회:학술대회논문집
    • /
    • 2007.08a
    • /
    • pp.285-288
    • /
    • 2007
  • This article presents the change characteristics of induced noise whether the sheath layer of the cable is grounded or not. As what affects the induced noise, there are power influence or longitudinal transverse voltages and its weighted filtered voltage. The sheath ground is basicaly predicted to have the effects of alleviation on the power influence. But practically the effects may not happen in the case of common cable's sheath layer. Rather there are cases that the ground of sheath affects so that the noise level could increase. So we need to scrutinize the effects of the sheath gorund in the measures for the protection against electromagnetic induction by powerline or traction line system. And the evaluation of using the designated shielding purpose cable is needed.

  • PDF

ACPR Analysis of Millimeterwave OFDM System with Power Amplifier's Phase Distortion (전력증폭기 위상왜곡에 의한 밀리미터파 OFDM 시스템의 ACPR 해석)

  • Roh, Hee-Jung
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.18 no.5
    • /
    • pp.151-155
    • /
    • 2004
  • Millimeterwave OFDM wireless LAN system has been modeled for ACPR analysis. With simple AM-to-PM modeling for power amplifier and system simulation technique, power amplifier ACPR is simulated for OFDM modulation, Also, amplifier back-off value satisfying the required ACPR and the ACPR degradation have been predicted with the measured and modeled AM-tn-PM distortion.