연삭가공에서 이동열원에 의한 온도 분포 (A Moving Heat Source Caused by Temperature Distribution in Grinding Process)

  • 곽태경;하만경;구양;곽재섭
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 1997년도 추계학술대회 논문집
    • /
    • pp.899-902
    • /
    • 1997
  • The heat generated during surface grinding process can lead to elevate a grinding temperature, which cause the thermal damage to the workpiece material. Because of this reason, it is important to be able to predict the temperature which is occurred during grinding. The process parameters, therefore, should be adjusted properly to yield the acceptable workpiece temperature. In this study, we conducted an experimentation to obtain and also to analyze the temperature distribution of the workpiece with accordance in varying the grinding condition. For measuring the workpiece temperature, thermocouples of the CA type were inserted into the predetermined locations of the workpiece.

  • PDF

온돌을 이용한 바닥복사냉방의 제습시스템 적용에 관한 연구 (A Study on the Application of the Dehumidification System for Radiant Floor Cooling Using Ondol)

  • 임재한;여명석;양인호;김광우
    • 설비공학논문집
    • /
    • 제14권7호
    • /
    • pp.607-616
    • /
    • 2002
  • This study has been conducted to evaluate the applicability of the control method in the dehumidification-integrated radiant floor cooling system in terms of stability of the room air temperature and the control variables through experiments. To do this, the relationship between the control variables in preventing floor surface condensation is first analyzed and the control method is predetermined through simulations. The results are as follows. First, it is necessary to determine the operation status of the dehumidification system according to the relationship between floor surface temperature and dew point temperature in the conditioned space. Second, outdoor reset with indoor temperature feedback control is better than on/off bang-bang control with respect to temperature stability in controlling the room air temperature and the possibility of energy savings. Finally, the humidity sensor can be located with the current thermostat in that there are small differences in absolute humidity in vertical distribution.

직접 가열식 가열로 내 최적 분위기온도 분포 해석에 관한 연구 (A Study of Optimal Distribution of Gas Temperature in Directly-Fired Reheating Furnace)

  • 정의수;심성민;김영득;강덕홍;김우승
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2008년도 추계학술대회B
    • /
    • pp.2122-2125
    • /
    • 2008
  • Because the reheating furnace consumes a large amount of energy to heat up the slabs, it is very important to find an optimal temperature patterns in the furnace for energy saving as well as uniform target temperature at the exit of the furnace. In this study, the temperature profiles in the slab are determined by solving the transient one-dimensional heat conduction equation in conjunction with boundary conditions with total heat exchange factors. The optimal temperature patterns are obtained to minimize the fuel consumption with satisfying the predetermined constraint conditions. The design optimization is performed by using a genetic algorithm and the optimal results are validated with results obtained from the PIDO tool, called as P.I.A.n.O.

  • PDF

열응력과 수압이 화강암의 변형 거동에 미치는 영향 (Effects of the Thermal Stress and Water Pressure on the Deformation Behavior of Granite)

  • 윤용균
    • 화약ㆍ발파
    • /
    • 제29권1호
    • /
    • pp.34-40
    • /
    • 2011
  • 본 연구에서는 가곡광산 화강암의 변형거동에 열응력과 수압이 미치는 영향을 평가하였다. 열응력과 수압이 미치는 영향을 해석하기 위하여 화강암 시험편에 열을 가하여 200, 300, 400, 500, 600, $700^{\circ}C$ 예열시험편을 제작하였고, 500, 600, $700^{\circ}C$ 예열시험편에 7.5MPa의 수압을 가하였다. 예열시험편에 대한 일축압축시험 결과 예열온도가 증가함에 따라 시험편의 축변형률 및 횡변형률이 증가하는 것으로 나타났으며 특히 $600^{\circ}C$ 이상 시험편에서 변형률의 증가가 현저한 것으로 나타났다. 온도에 따라 시험편의 일축압축강도와 탄성계수는 지수적으로 감소하는 것으로 측정되었다. 수압을 받은 시험편은 그렇지 않은 시험편에 비해 비탄성적인 변형거동이 큰 것으로 나타났으며 이는 수압이 예열시험편 내에 존재하는 균열의 확장과 개구에 영향을 미친다는 것을 뜻한다.

방열기를 갖는 유입자냉식 변압기의 온도분포 해석 (Ana1ysis of Temperature Distribution in Oil-immersed Self-cooled Transformer with Radiator)

  • 김중경;한성진;오연호;박경엽
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년도 제37회 하계학술대회 논문집 B
    • /
    • pp.755-756
    • /
    • 2006
  • This paper presents the temperature distribution of the oil-immersed self-cooled transformer with radiator performed by coupled magneto-fluid-thermal analysis. Particularly, 3D temperature distribution of cooling oil and sub-components under the natural convection is obtained by computational fluid dynamics analysis, while heat sources are predetermined by magnetic field analysis using F.E.M. The predicted temperature distribution of the power transformer model is compared with the measured data for verifying the validity of the proposed analysis.

  • PDF

Composting Greenhouse using The Forced Aeration Method

  • Hong, Ji-Hyung;Park, Keum-Joo;Sohn, Bo-Kyoon
    • 한국농업기계학회:학술대회논문집
    • /
    • 한국농업기계학회 1996년도 International Conference on Agricultural Machinery Engineering Proceedings
    • /
    • pp.685-691
    • /
    • 1996
  • Recent research in composting greenhouse has focused on some of the fundamental properties during the process such as temperature , carbon dioxide content and odors which change as the composting progresses. The composting greenhouse of cattle manure with rice hulls by a forced aeration method without turning is available for the practical proposition. The control of a predetermined temperature range(45-65$^{\circ}C$) is possible if intermittent aeration is used. The carbon dioxide concentration was maintained in the range from 400 to 2650 ppm by the intermittent aeration. The ammonia emission rose rapidly leading to a temperature increase of composting material up to more than 60$^{\circ}C$ for six days. Ammonia emission declined quickly and could hardly be detected after 10 days of running period.

  • PDF

흐름식 아임계수에 의한 경유오염토양의 정화 (Remediation of Diesel Contaminated Soil Using Flowing Subcritical Water)

  • 이광춘;정선국;정선용;조영태;박정훈
    • 한국지하수토양환경학회지:지하수토양환경
    • /
    • 제16권3호
    • /
    • pp.10-16
    • /
    • 2011
  • The experimental studies for remediation of diesel contaminated soils were performed using subcritical water in laboratory scale. Contaminated soils from industrial area and artificially contaminated soils were utilized for soil remediation. Experimental system was composed for subcritical water to flow upward through the soil packed column for extracting contaminants. 10 g of contaminated soil was packed into the column and water flow rate was 2 mL/min. To evaluate the effects of temperature, pressure and treatment time on the removal efficiency, temperature was changed from 100$^{\circ}C$ to 350$^{\circ}C$, pressure from 50 bar to 220 bar and treatment time at the predetermined temperature from 0 min to 120 min. The purification efficiency increased as temperature increased. However, the effect of pressure and treatment time was low. Temperature 250$^{\circ}C$, pressure 50 bar and treatment time 30 min were selected for optimal operating condition for this study.

열가소성 수지 복합재료에서의 수지 함침 (The Impregnation of Thermoplastic Resin into a Unidirectional Fiber Bundle)

  • 김태욱;전의진;이우일
    • 한국기계연구소 소보
    • /
    • 통권18호
    • /
    • pp.163-168
    • /
    • 1988
  • Impregnation of molten thermoplastic resin into continuous unidirectional fiber bundles was investigated. The degree of impregnation is defined as the ratio between the number of impregnated fibers and the total number of fibers of a bundle. The degree of impregnation was modeled as a function of time, impregnation pressure, temperature and tow size assuming the radial inward flow through the fiber bundle is governed by the Darcy's law. The permeability was assumed to be constant. Experiments were performed to evaluate the validity of the medel. Today's T300 graphite fiber bundles and Polyetheretherketone(PEEK) resin was used. A fiber bundle and resin powder were put into a mold and pressure and temperature were applied. After a predetermined time, the sample was taken out and microphotographs of the cross-section were taken. From the microphotographs, the number of impregnated fibers was counted and then the degree of impregnation was determined. Experiments were also performed for different tow sizes. Good agreements were found between the model and the experiments rendering a confidence in the model.

  • PDF

공침법에 의한 $Ba_2Ti_9O_{20}$ 합성과 $ZrO_2$ 첨가효과에 관한 연구 (A Study on Synthesis of $Ba_2Ti_9O_{20}$ by Coprecipitation Process and the Effect of $ZrO_2$ Addition)

  • 이병하;이경희;이헌식;전성용
    • 한국세라믹학회지
    • /
    • 제30권12호
    • /
    • pp.1023-1028
    • /
    • 1993
  • To obtain a single phase of Ba2Ti9O20 at lower temperature than previious other researches. We investigated the effect of Zr substitution for predetermined portions of Ti in Ba2Ti9O20. In this study, the four compounds(x=0, 0.028, 0.048, 0.068) of Ba2(Ti1-xZrx)9O20 were prepared by coprecipitation reaction of BaCl2, TiCl4 and ZrOCl2 with (NH4)2CO3 and NH4OH as the coprecipitating agents and pH regulators, in queous solution. Owing to 4.8 mol% addition, the single phase of Ba2Ti9O20 showing high Q was obtained at 115$0^{\circ}C$ which is lower by 25$0^{\circ}C$ than the temperature in case of mechanical mixtures of BaCO3 and TiO2.

  • PDF

ANALYSIS OF THE ANODIC OXIDATION OF SINGLE CRYSTALLINE SILICON IN ETHYLEN GLYCOL SOLUTION

  • Yuga, Masamitsu;Takeuchi, Manabu
    • 한국표면공학회지
    • /
    • 제32권3호
    • /
    • pp.235-238
    • /
    • 1999
  • Silicon dioxide films were prepared by anodizing silicon wafers in an ethylene $glycol+HNO_3(0.04{\;}N)$ at 20 to $70^{\circ}C$. The voltage between silicon anode and platinum cathode was measured during this process. Under the constant current electrolysis, the voltage increased with oxide film growth. The transition time at which the voltage reached the predetermined value depended on the temperature of the electrolyte. After the time of electrolysis reached the transition time, the anodization was changed the constant voltage mode. The depth profile of oxide film/Si substrate was confirmed by XPS analysis to study the influence of the electrolyte temperature on the anodization. Usually, the oxide-silicon peaks disappear in the silicon substrate, however, this peak was not small at $45^{\circ}C$ in this region.