• Title/Summary/Keyword: Precision attachment

Search Result 76, Processing Time 0.024 seconds

A Study on the Optical Device Alignment Characteristics Improvement using Multi-Axis Ultra Precision Stage (극초정밀 다축 스테이지를 이용한 광소자 정렬 특성 향상에 관한 연구)

  • Jeong, Sang-Hwa;Cha, Kyoung-Rae;Kim, Gwang-Ho
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.22 no.12 s.177
    • /
    • pp.175-183
    • /
    • 2005
  • In recent years, as the demands of VBNS and VDSL increase, the development of kernel parts of optical communication such as PLC(Planar Light Circuit), Coupler, and WDM elements increases. The alignment and the attachment technology are very important in the fabrication of optical elements. In this Paper, the optical alignment characteristic of multi-axis ultra precision stage is studied. The alignment algorithms are studied for applying to the ultra precision multi-axis stage. The alignment algorithm is comprised of field search and peak search algorithms. The contour of optical power signals can be obtained by field search and the precise coordinate can be found out by peak search. Three kinds of alignments, such as 1 ch. input vs. 1 ch. output optical stack, 1 ch. input vs. 8 ch. output PLC stacks, and ferrule vs. ferrule, are performed for investigating the alignment characteristics.

Design and Strain Analysis of Precision 3-component Load Cell

  • Kim, Gab-Soon;Rhee, Se-Hun
    • International Journal of Precision Engineering and Manufacturing
    • /
    • v.1 no.1
    • /
    • pp.22-32
    • /
    • 2000
  • This paper describes the development of a precision 3-component load cell with plate beams which may be used for measuring forces Fx, Fy and moment Mz simultaneously in industry. The equations to predict the bending strains on the surface of the beams under forces or moment are derived, the attachment location of strain gages of each sensor is determined, and 3-component load cell is carried out. It reveals that the rated strain calculated from the derived equations are good agreement with the results from Finite Element Method analysis.

  • PDF

Design and Strain Analysis of Precision 3-component Load Cell (정밀 3분력(Fz, Fy, Mz) 로드셀의 설계 및 변형률해석)

  • Kim, Gab-Soon;Rhee, Se-Hun;Um, Ki-Woan
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.16 no.3 s.96
    • /
    • pp.222-232
    • /
    • 1999
  • This paper describes the development of a precision 3-component load cell with plate beams which may be used for measuring forces Fx, Fy and moment Mz simultaneously in industry. We have derived equations to predict the bending strains on the surface of the beams under forces or moment. We have also determined the attachment location of strain gages of each sensor and fabricated 3-component load cell. To evaluate the rated strain and interference error of each sensor, we have carried out characteristic test of precision 3-component load cell. It reveals that the rated strain calculated from the derived equations are good agreement with the results from Finite Element Method analysis.

  • PDF

Comparison of Stress of the Abutment Teeth and Denture Base in Distal Extension Removable Partial Dentures Retained Konus Crown, Precision Attachment and RPI Clasp with the Occlusal Load Application (유리단 국소의치의 교합하중 적용시 이중금관, 어태치먼트 및 RPI clasp 유지장치에 따라 지대치와 의치상에 미치는 응력 비교)

  • Jun, In-Sik;Kim, Bu-Sub;Chung, In-Sung
    • Journal of Technologic Dentistry
    • /
    • v.28 no.2
    • /
    • pp.331-346
    • /
    • 2006
  • Free-end partial dentures, which are supported by teeth surrounded by dental root membranes and elastic mucous membrane tissues, may cause stress to the abutment teeth due to external force imposed on the denture base, increase the mobility of the abutment teeth, and bring about a change in the periodontal tissue. General retainers used in partial dentures are categorized into clasp, attachment, and Konus crown. Stress imposed on the abutment teeth and mobility of the denture base have relations with the lifetime of a crown and abutment teeth, and have direct relations with the chewing ability. Thus, a need arises to make a comparative analysis of stress of the three direct retainers on the abutment teeth and interpret the mobility of the denture base. This study designed three kinds of removable partial dentures (one kind of attachment partial denture, one kind of Konus crown partial denture, and one kind of clasp partial denture), and fabricated Dentiforms of bilateral partial dentures (Kennedy Class I) with lower left 1st premolar and lower right 1st and 2nd premolars being as the abutment teeth. A strain gauge was installed in the mesial and distal surface of the lowerr left 1st premolar (No. 34) of the fabricated dentiform and in the lower part of the denture base, and installed were a clasp partial denture, an attachment partial denture, and a Konus crown partial denture. Then, the vertical static load of 5kgf and 7.5kgf at the occlusion surface of the lower left No. 6 molar was generated for a total of 20 frequencies of load each using a push-full gauge, and thus a change in the output of the strain gauge was measured. With the respective application of Konus crown, attachment and RPI clasp in the free-end partial denture, surveyed was the distribution of stress imposed on the abutment teeth and the denture base according to the location of occlusion force load so as to come up with the following results. 1. Konus crown and attachment partial dentures generated much stress, and more stress on the abutment teeth than RPI clasp dentures did. Attachment dentures tended to further intensify stress on the abutment teeth than Konus crown dentures did. 2. Attachment dentures and Konus dentures imposed less stress on the denture base than RPI clasp dentures did. There was no stress difference between Attachment and Konus crown dentures. 3. Dentures that were designed with the application of retainers using sturdy linkage methods tended to be less mobile.

  • PDF

A Clinical Study on CSP Attachment Partial Denture (CSP 를 이용한 정밀부착형 국부의치에 관한 임상적 연구)

  • Kim, Kwang-Nam
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.19 no.1
    • /
    • pp.7-16
    • /
    • 1981
  • The technology of precision attachments has developed at such a pace that from a very few T-shaped attachments and bar attachments from the years 1915 to 1935 since removable bridge utilizing a T-shaped intracoronal attachment was constructed by Dr. Herman E.S. Chayes in 1906. There are now more than 120 models of the most diversified designs, ready made or laboratory fashioned. In 1971, 126 attachments were listed and classified by Mensor in his E M Attachment Selector. This selector consists of five charts giving specifications as to type, vertical dimensions, application, type of resilience, size of movement, type of retention and type of material and alloy. Thus the E M Attachment Selector is a useful guide for dentists to choose the attachment for his patients. But dentists should apply the attachment in each patient's case according to an accurate diagnosis and treatment plan. This paper is a case report of removable partial dentures utilizing CSP, PD and Bar attachment on a patient who needed full mouth reconstruction. Patient has right first, second molar and left first molar on the upper arch and also left first molar, first premolar and right canine on the lower arch. (Fig. 5)All remaining teeth are relatively healthy in their supporting tissues. On upper arch, ring shape CSP attachment was designed on left first molar and modified ring shape CSP attachment was designed on right first and second molar as the direct retainer of the removable partial denture. Full palatal coverage was used as the major connector in this case. (Fig. 23) On lower arch, author first splinted with a fixed bridge between left first molar and second premolar and a splint bar between left second premolar and right canine. (Fig. 11) A lower removable partial denture in which was designed with an Aker clasp on the left first molar and a PD attachment on .the right canine was constructed. (Fig. 17) This denture could get additional support from anterior splint bar. After both removable partial dentures were delivered to the patient (Fig. 26), author evaluated function of the dentures and supporting structures of the abutment teeth by means of clinical and X-ray examinations for eighteen months. According to the examination data author came to the conclusion that the prognosis of this case was excellent.

  • PDF

Overdentures using newly designed metal ball attachment containing predetermined gap with stress breakers (일정한 간극으로 새롭게 고안된 완압형 볼 어태치먼트를 이용한 피개의치 수복)

  • Yoo, Jin-Joo;Kim, Man-Yong;Yoon, Joon-Ho
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.55 no.3
    • /
    • pp.311-318
    • /
    • 2017
  • Several types of attachments have been used for implant supported and/or retained overdentures. Locator is one of the stud type attachments and it has been generally used. However, the colored matrix is resilient and vulnerable to wear, so frequent post-insertion maintenance is needed. To solve this problem, it is necessary to introduce innovative attachment system. Overdentures using Air Gap attachment (AGA) has improved masticatory function and facial esthetics. AGA is made of metal, so it could be more resistant to wear or friction than the other resilient attachments. Nevertheless, AGA plays a role in stress breakers because it allows movement during denture movement with predetermined gap. In addition, both pre-existing implants and natural teeth were successfully used for connection of AGA. AGA could replace other unsplinted type of attachments. Overdentures using AGA could provide satisfactory result in terms of function, esthetics and retention. However, long term follow up is needed.

A Study on the Optical Element Alignment of Ultra Precision Multi-Axis Stage (극초정밀 다축 위치제어장치의 광소자 정렬 특성에 관한 연구)

  • Jeong S.H.;Cha K.R.;Kim H.U.;Choi S.B.;Kim G.H.;Park J.H.
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2005.06a
    • /
    • pp.1190-1193
    • /
    • 2005
  • In recent years, as the demands of VBNS and VDSL increase, the development of kernel parts of optical communication such as PLC(Planar Light Circuit), Coupler, and WDM elements increases. The alignment and the attachment technology are very important in the fabrication of optical elements. In this paper, the optical alignment characteristics of multi-axis ultra precision stage were studied. The alignment algorithms were studied for applying to the ultra precision multi-axis stage. The alignment algorithm is comprised of field search and peak search algorithms. The contour of optical power signals can be obtained by field search and the precise coordinate can be found out by peak search. Two kinds of alignments, such as 1 ch. input vs. 1 ch. output optical stack, and 1 ch. input vs. 8 ch. output PLC stacks were performed for investigating the alignment characteristics.

  • PDF

A Study on The Motion Charateristic of Ultra Precision Multi-Axis Stage for Optical Element Alignment (광소자 정렬용 극초정밀 다축 위치 조정장치의 운동특성에 관한 연구)

  • Jeong S.H.;Cha K.R.;Kim H.U.;Choi S.B.;Kim G.H.;Park J.H.
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2005.06a
    • /
    • pp.1219-1222
    • /
    • 2005
  • As the optical communication is introduced to the backbone network at first and becomes a general communication method of network, the demand of kernel parts of optical communication such as PLC(Planar Light Circuit), Coupler, and WDM(Wavelength Division Multiplexing) element increases. The alignment and the attachment technology are very important in the fabrication of optical elements. In this paper, the driving mechanism of ultra precision stage is studied with the aim of optimal design of stage. The travel and the resolution of stage are investigated. The hysteresis of the stage is generated because of PZT actuator. The hysteresis and the inverse hysteresis are modeled in X, Y, and Z-axis motion. The input data of desired displacement to the stage according to input voltage is obtained from the inverse hysteresis equation. In the result of experiments with the input data, the errors due to hysteresis are well compensated.

  • PDF

A Study on the Performance Characteristics of Float Type Flow Meter (부자식 유량계의 성능특성에 관한 연구)

  • 김춘식;김경근;이영호
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.9 no.4
    • /
    • pp.339-347
    • /
    • 1985
  • Precise measurement of flowrate is considered as an important measuring factor in mechanical and chemical experiment. Although there are many methods to measure flowrate, Float type flowmeter is widely used because of its easy attachment to piping and high measuring precision. To design the precise float type flowmeter, much design information such as tapered-tube dimensions, float size, float shape and float material is required. In this paper, fundamental design theory for float type flowmeter according to the given flowrate range is suggested and compensation coefficients of volumetric and weight flowrate for water, R-113 and air are calculated.

  • PDF

Hybrid Prosthesis Supported by Osseointegrated Implants in Maxilla (골유착성 임프란트에 의해 지지되는 새로운 설계의 Hybrid Prosthesis)

  • Lee, J.S.;Shin, S.W.
    • Journal of the Korean Academy of Esthetic Dentistry
    • /
    • v.8 no.1
    • /
    • pp.46-59
    • /
    • 1999
  • A fixed bridge is preferred as a prosthetic option supported by oral implants. However, it is very difficult to re tore edentulous maxilla with fixed prosthesis in cases with improper position and angulation of fixtures, abnormal jaw relation, and need for proper lip support. Six Br${\aa}$nemark implants were installed in edentulous maxilla opposing mandible with natural dentition. A removable hybrid prosthesis attached to a bar milled by 6 degrees was therefore designed to overcome such disadvantages of fixed prosthesis. Lateral stabilization of removable prosthesis was obtained by framework closely fitting the milled bar. Support for the prosthesis was ensured by three elevated areas on the bar. Two precision attachments(CEKA REVAX) provided appropriate direct and indirect retention without influencing support. A clinical and laboratory procedure was presented.

  • PDF