• 제목/요약/키워드: Preamplifier

검색결과 107건 처리시간 0.026초

Development of Portable Measurement Unit with Wireless Transmission by Wireless LAN for Long-term Monitoring (장기간 소자 모니터링이 용이한 소형 무선랜 무선송신 계측장치 개발)

  • Park, So Jeong;Park, Il-Hoo;Moon, Young-Sun;Lee, Kook Jin;Kim, Gyu-Tae
    • Journal of the Semiconductor & Display Technology
    • /
    • 제17권1호
    • /
    • pp.45-49
    • /
    • 2018
  • Portable microcontroller based measurement unit is demonstrated using digital-to-analog convertor module, analog-to-digital convertor module and additional preamplifier circuit with low-budget but excellent performances. Using the designed measurement unit, the measurement of current below 1 nA with applying voltage up to 5 V is successfully carried out. With the WiFi module in microcontroller, measured data is transferred to the user's computer. To evaluate the performance of the measurement unit, the transfer curve of a commercial N-type field effect transistor was measured with the measurement unit and the results is well consistent with that measured using commercial characterization system.

Acoustic Measurements of Wasp (Vespa simillima xanthoptera Cameron) and Honey Bees with their Frequency Characteristics (황말벌과 꿀벌의 음향 측정과 주파수 특성)

  • Kim, Geon;Kim, HanSoo;Paeng, Dong-Guk;Lim, Yoon-Kyu
    • Journal of Apiculture
    • /
    • 제34권1호
    • /
    • pp.7-13
    • /
    • 2019
  • Vespid wasps (Vespa spp.) are the most noxious pests on apiculture, resulting in significant economic losses. Early monitoring and management are the first step to prevent the damages from vespid wasps. In this study, the acoustic signals from wasps and honey bees were measured by a microphone with a preamplifier and an analog-digital converter. In frequency analysis of the acoustic signals from wasps and honey bees, there were differences between the two species. While the fundamental frequency of the wasps was analyzed to be about 100 Hz with the strong harmonic frequencies, that of the honey bees was about 200~250 Hz. The 2nd harmonic signals from wasp were strongest while the fundamental ones from honey bees were. These different sound features generated by wasps or honey bees might be applied to develop the early monitoring system of the incursion of wasps to the apiary.

Analysis of the Microwave Amplifier Ultra-wideband Characteristics with Feedback Amplifier Module (궤환증폭모듈을 이용한 마이크로파 증폭기의 초광대역특성 분석)

  • 김영진;이영철
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • 제19권11호
    • /
    • pp.2238-2248
    • /
    • 1994
  • In this paper, we analyze a Microwave Amplifier Ultra-Wideband charateristic to apply Multi-Giga b/s optical receiver preamplifier in high speed optical communication system. To obtain frequency expanding effect. we analyze the frequency gain degradation effects of capacitances in the GaAs MESFET small-signal equivalent circuit and design Feedback amplifier Module(FAM) which has inductor peaking elements to compensate its effects and to expand frequency band. We derive optimum inductor peaking values in order to get flat gain in frequency band. The input and the output impedances of FAM are matched by Real Frequency Method and we design one and two stage ultra wideband microwave amplifier. With simulation results, it show $6.36\sim6.86dB$ and $9.1\sim10.3dB$ gains and execllent gain flatness in $0.5\sim12GHz$ respectively.

  • PDF

Two Stage CMOS Class E RF Power Amplifier (2단 CMOS Class E RF 전력증폭기)

  • 최혁환;김성우;임채성;오현숙;권태하
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • 제7권1호
    • /
    • pp.114-121
    • /
    • 2003
  • In this paper, low voltage and two stage CMOS Class E RF power amplifier for ISM(Industrial/Scientific/Medical) Open Band is presented. The power amplifier operates at 2.4GHz frequency, and is designed and simulated with a 0.35um CMOS technology and HSPICE simulator. The power amplifier is simple structure of two stage Class E power amplifier. The design procedure determing matching network was presented. The power amplifier is composed of input stage matching network, preamplifier, interstage matching network, power amplifier, and output stage matching network. The matching networks of input stage and interstage were constituted by pi($\pi$) type and L type respectively. At 2.4GHz operating frequency, and with a 2.5V supply voltage, the power amplifier delivers 23dBm output power to a 50${\Omega}$ load with 39% power added efficiency(PAE).

AN EXPERIMENTAL STUDY OF THE EFFECT ON PULP TEMPERATURE DURING ABUTMENT PREPARATION (지대치 형성이 치수온도에 미치는 영향에 관한 실험적 연구)

  • Kim, Byong-Ki
    • The Journal of Korean Academy of Prosthodontics
    • /
    • 제14권1호
    • /
    • pp.47-54
    • /
    • 1976
  • Pulpal temperature is changed in response for various conditions which were mechanical, thermal, chemical and biological stimuli. This study was performed to determine the pulpal temperature changes which were using air turbine with air-water coolant, water coolant, and conventional dental engine with water coolant and no coolant on 28 canine of dogs. In order to record pulpal temperature, pulp chamber was opened on the labiocervical area of canine. Thermocouple was inserted into pulp chamber and was fixed with filling material(dycal). Changes of pulpal temperature were recorded on the physiograph, which had been standardized temperature degree, through thermocouple to thermistor bridge and carrier preamplifier. The amount of experimental temperature change to that of control was interpreted in the pulpal cavity. The obtained results were as followings: 1. The mean normal temperature was 33.07 centigrade. 2. The temperature was decreased than normal pulpal temperature. It was 12.04 centigrade in reduction by air turbine with air-water coolant, 7.17 centigrade in reduction by air turbine with air coolant, 5.54 centigrade in reduction by conventional engine with water coolant, and 1.26 centigrade in reduction by conventional engine with no coolant. 3. The time for maximal temperature change was 53.3 seconds in reduction by air turbine with air-water coolant, 73.4 seconds in reduction by air turbine with air coolant, 50.9 seconds in reduction by conventional engine with water coolant, and 27.1 seconds in reduction by conventional engine with no coolant. 4.. After reduction was ceased, the recovery time to normal pulp temperature was 287.1 seconds in air turbine with air-water coolant, 189.0 seconds in air turbine with air coolant, 86.9 seconds in conventional engine with water coolant, and 52.9 seconds in conventional engine with no coolant respectively.

  • PDF

A Study on the Reception Sensitivity of the Optical Receiver with the Order Change of the Optical Filter in Optical Preamplifier System (광 전치 증폭시스템에서 광필터의 차수변화에 따른 광수신기의 수신감도에 관한 연구)

  • Ra, Yoo-Chan
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • 제17권3호
    • /
    • pp.218-223
    • /
    • 2016
  • This study examined the order of the Butterworth filter for the correlation on the sensitivity of the receiver in the receiver of an optical system. In the general case, the sensitivity of the receiver is increased if the order of the filter was increased more. This is because increasing the order of the filter response of the normalized frequency of the filter is similar to the rectangular wave. For that reason, the method used to increase the order of the filter increases the sensitivity of the receiver. On the other hand, a method of increasing the order of the filter and makes the system complicated increases the cost of the system. This study examined the correlation between the order of the sensitivity of the receiver filter and to configure the system by simply looking for ways to reduce the cost of the system. The simulation results showed that increasing the order of the filter resulted in a receiver that can determine if the sensitivity is raised. In addition, the order of the Butterworth filter range that does not reduce the sensitivity of the receiver was 2. Therefore, it will be possible to implement an inexpensive optical system of the receiver using the data from this study.

A study on the changes of the noise reception sensitivity in the optical system (광시스템의 잡음에 따른 수신감도 변화에 관한 연구)

  • Ra, Yoo-Chan
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • 제16권1호
    • /
    • pp.677-682
    • /
    • 2015
  • In this paper, we investigated the effect of light on the performance of the receiver system noise and external noise added from the ever-present influence in general optical system. And calculated the reception sensitivity of the receiver at the time of off-keying transmission - from the optical transmission system in consideration of the case that the photo detector has a quantum yield of less than one-one. Not less than 50 it was confirmed that it is possible to configure the low power system is calculated and compared with the case where less than 300 the receiver sensitivity of the optical system to maintain the standard error probability. However, even if these values were considered, and the preamplifier in the receiver, considering a case of using a low-output light source, so that a heavy burden in the value less than the actual system installation, using the light source having less than the output, as shown in Figure 3, the results that were obtained also may be used.

Preliminary Research of CZT Based PET System Development in KAERI

  • Jo, Woo Jin;Jeong, Manhee;Kim, Han Soo;Kim, Sang Yeol;Ha, Jang Ho
    • Journal of Radiation Protection and Research
    • /
    • 제41권2호
    • /
    • pp.81-86
    • /
    • 2016
  • Background: For positron emission tomography (PET) application, cadmium zinc telluride (CZT) has been investigated by several institutes to replace detectors from a conventional system using photomultipliers or Silicon-photomultipliers (SiPMs). The spatial and energy resolution in using CZT can be superior to current scintillator-based state-of-the-art PET detectors. CZT has been under development for several years at the Korea Atomic Energy Research Institute (KAERI) to provide a high performance gamma ray detection, which needs a single crystallinity, a good uniformity, a high stopping power, and a wide band gap. Materials and Methods: Before applying our own grown CZT detectors in the prototype PET system, we investigated preliminary research with a developed discrete type data acquisition (DAQ) system for coincident events at 128 anode pixels and two common cathodes of two CZT detectors from Redlen. Each detector has a $19.4{\times}19.4{\times}6mm^3$ volume size with a 2.2 mm anode pixel pitch. Discrete amplifiers consist of a preamplifier with a gain of $8mV{\cdot}fC^{-1}$ and noise of 55 equivalent noise charge (ENC), a $CR-RC^4$ shaping amplifier with a $5{\mu}s$ peak time, and an analog-to-digital converter (ADC) driver. The DAQ system has 65 mega-sample per second flash ADC, a self and external trigger, and a USB 3.0 interface. Results and Discussion: Characteristics such as the current-to-voltage curve, energy resolution, and electron mobility life-time products for CZT detectors are investigated. In addition, preliminary results of gamma ray imaging using 511 keV of a $^{22}Na$ gamma ray source were obtained. Conclusion: In this study, the DAQ system with a CZT radiation sensor was successfully developed and a PET image was acquired by two sets of the developed DAQ system.

A Mixed-Signal IC for Magnetic Stripe Storage System (자기 띠 저장 시스템을 위한 혼성 신호 칩)

  • Lim, Shin-Il;Choi, Jong-Chan
    • Journal of IKEEE
    • /
    • 제2권1호
    • /
    • pp.34-41
    • /
    • 1998
  • An integrated circuit for magnetic stripe storage system is implemented. All the analog and digital circuits are integrated in one chip. The analog block contains preamplifier, peak detecter, comparator and reference generater. And digital block includes reference window signal generater, up/down counter for F/2F signal measurement, bit-error detection logic, and control logic. Both the encoding and decoding functions for F/2F signal processing are provided. An AGC(automatic gain control) circuit which was included in conventional circuits is eliminated due to optimized circuit design. Misreading prevention circuits are also proposed by fixing up new reference bit when broken bits are detected. The prototype chip is implemented using $0.8{\mu}m$ N-well CMOS technology and operates from 3.3 V to 7.5 V of supply voltage. It occupies a die area of $3.04mm^2(1.6mm{\times}1.9mm)$ and dissipates 8 mW with a 5 V supply voltage.

  • PDF

Multi-Channel Data Acquisition System Design for Spiral CT Application

  • Yoo, Sun-Won;Kim, In-Su;Kim, Bong-Su;Yun Yi;Kwak, Sung-Woo;Cho, Kyu-Sung;Park, Jung-Byung
    • Proceedings of the Korean Society of Medical Physics Conference
    • /
    • 한국의학물리학회 2002년도 Proceedings
    • /
    • pp.468-470
    • /
    • 2002
  • We have designed X-ray detection system and multi-channel data acquisition system for Spiral CT application. X-ray detection system consists of scintillator and photodiode. Scintillator converts X-ray into visible light. Photodiode converts visible light into electrical signal. The multi-channel data acquisition system consists of analog, digital, master and backplane board. Analog board detects electrical signal and amplifies signal by 140dB. Digital board consists of MUX(Multiplex) which routes multi-channel analog signal to preamplifier, and ADC(Analog to Digital Converter) which converts analog signal into digital signal. Master board supplies the synchronized clock and transmits the digital data to image reconstructor. Backplane provides electrical power, analog output and clock signal. The system converts the projected X-ray signal over the detector array with large gain, samples the data in each channel sequentially, and the sampled data are transmitted to host computer in a given time frame. To meet the timing limitation, this system is very flexible since it is implemented by FPGA(Field Programmable Gate Array). This system must have a high-speed operation with low noise and high SNR(signal to noise ratio), wide dynamic range to get a high resolution image.

  • PDF