• Title/Summary/Keyword: Preamplifier

Search Result 107, Processing Time 0.023 seconds

Energy-band model on photoresponse transitions in biased asymmetric dot-in-double-quantum-well infrared detector

  • Sin, Hyeon-Uk;Choe, Jeong-U;Kim, Jun-O;Lee, Sang-Jun;No, Sam-Gyu;Lee, Gyu-Seok;Krishna, S.
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2010.08a
    • /
    • pp.234-234
    • /
    • 2010
  • The PR transitions in asymmetric dot-in-double-quantum-well (DdWELL) photodetector is identified by bias-dependent spectral behaviors. Discrete n-i-n infrared photodetectors were fabricated on a 30-period asymmetric InAs-QD/[InGaAs/GaAs]/AlGaAs DdWELL wafer that was prepared by MBE technique. A 2.0-monolayer (ML) InAs QD ensemble was embedded in upper combined well of InGaAs/GaAs and each stack is separated by a 50-nm AlGaAs barrier. Each pixel has circular aperture of 300 um in diameter, and the mesa cell ($410{\times}410\;{\mu}m^2$) was defined by shallow etching. PR measurements were performed in the spectral range of $3{\sim}13\;{\mu}m$ (~ 100-400 meV) by using a Fourier-transform infrared (FTIR) spectrometer and a low-noise preamplifier. The asymmetric photodetector exhibits unique transition behaviors that near-/far-infrared (NIR/FIR) photoresponse (PR) bands are blue/red shifted by the electric field, contrasted to mid-infrared (MIR) with no dependence. In addition, the MIR-FIR dual-band spectra change into single-band feature by the polarity. A four-level energy band model is proposed for the transition scheme, and the field dependence of FIR bands numerically calculated by a simplified DdWELL structure is in good agreement with that of the PR spectra. The wavelength shift by the field strength and the spectral change by the polarity are discussed on the basis of four-level transition.

  • PDF

Acoustic Emission Monitoring of Incipient Failure in Journal Bearings( III ) - Development of AE Diagnosis System for Journal Bearings - (음향 방출을 이용한 저어널 베어링의 조기 파손 감지(III) -저어널 베어링 AE 진단 시스템 개발-)

  • Chung, Min-Hwa;Cho, Yong-Sang;Yoon, Dong-Jin;Kwon, Oh-Yang
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.16 no.3
    • /
    • pp.155-161
    • /
    • 1996
  • For the condition monitoring of the journal bearing in rotating machinery, a system for their diagnosis by acoustic emission(AE) was developed. AE has been used to detect abnormal conditions in the bearing system. It was found from the field application study as well as the laboratory experiment using a simulated journal bearing system that AE RMS voltage was the most efficient parameter for the purpose of current study. Based on the above results, algorithms and judgement criteria for the diagnosis system was established. The system is composed of four parts as follows: the sensing part including AE sensor and preamplifier, the signal processing part for RMS-to-DC conversion to measure AE ms voltage, the interface part for transferring RMS voltage data into PC using A/D converter, and the software part including the graphic display of bearing conditions and the diagnosis program.

  • PDF

Microcomputer-based Data Acquisition System for the Measurements of Temperature and Weight in Food Processing (마이크로 컴퓨터를 이용한 식품가공(食品加工) 공정중(工程中)의 온도및 무게 측정용(測定用) Analog-digital 변환(變換)및 접속(接續) 시스템의 제작(製作))

  • Choi, Boo-Dol;Chun, Jae-Kun
    • Korean Journal of Food Science and Technology
    • /
    • v.19 no.2
    • /
    • pp.129-133
    • /
    • 1987
  • To develop a microcomputer-based data acquisition system for measurement of variables such as temperature and weight in food process, a low-cost data acquisition system was developed using an Apple II microcomputer. The system consisted of a microcomputer, a temperature sensor made of pt-100, a strain gauge load cell for weighing, a preamplifier for signal conditionings and an interface device. Interface device was built with programmable interface chip MC 6821, tristate buffer 74244 and analog-to-digital converter ADC 0809. The analog signals of temperature and weight were serially acquisited upon the program. The BASIC language was used for operating the data acquisition and data handling programs. The system successfully measured the variables such as temperature and weight with various sampling intervals in food dehydration process.

  • PDF

Development of a High-Performance Bipolar EEG Amplifier for CSA System (CSA 시스템을 위한 양극 뇌파증폭기의 개발)

  • 유선국;김창현;김선호;김동준
    • Journal of Biomedical Engineering Research
    • /
    • v.20 no.2
    • /
    • pp.205-212
    • /
    • 1999
  • When we want to observe and record a patient's EEG in an operating room, the operation of electrosurgical unit(ESU) causes undesirable artifacts with high frequency and high voltage. These artifacts make the amplifiers of the conventional EEG system saturated and prevent the system from measuring the EEG signal. This paper describes a high-performance bipolar EEG amplifier for a CSA (compressed spectral array ) system with reduced ESU artifacts. The designed EEG amplifier uses a balanced filter to reduce the ESU artifacts, and isolates the power supply and the signal source of the preamplifier from the ground to cut off the current from the ESU to the amplifier ground. To cancel the common mode noise in high frequency, a high CMRR(common mode rejection ratio) diffferential amplifier is used. Since the developed bipolar EEG amplifier shows high gain, low noise, high CMRR, high input impedance, and low thermal drift, it is possible to observe and record more clean EEG signals in spite of ESU operation. Therefore the amplifier may be applicable to a high-fidelity CSA system.

  • PDF

The Effect of Acupuncture Stimulation at the BL60, HT8 Acupoint to the Inferior Mesenteric Nerve Activity, Heart Rate and Mean Arterial Blood Pressure in Rats (곤륜(崑崙).소부(少府) 침자(鍼刺)가 하장간막신경(下腸間膜神經) 활성(活性)과 혈압(血壓) 및 심박수(心搏數)에 미치는 영향(影響))

  • Lee Kang-Uk;Yun Yeo-Chung;Kim Jeong-Sang;Na Chang-Su
    • Korean Journal of Acupuncture
    • /
    • v.19 no.2
    • /
    • pp.41-49
    • /
    • 2002
  • Objectives : The aim of the present study is to observe effects of acupuncture related with the nerve system, Inferior mesenteric nerve activity(IMNA) was examined on BL60 acupuncture closely connected with the bladder and HT8 with little tied. Materials and methods : Acupunctures were performed during 100 seconds after stabilization. IMNA was measured by micromanipulator, preamplifier, mean arterial pressure(MAP) and heart rate were observed by blood pressure transducer, 4-channel transducer amplifier in anesthetized rat. Results : On BL60 acupuncture, the heart rate was not significantly decreased but IMNA, MAP were significantly decreased and Maximum peak of IMNA was increased during inserted acupuncture, decreased after ejected acupuncture respectively. On HT8 acupuncture, IMNA was decreased during acupuncture than before acupuncture but the others did not showed signigicant difference. Conclusions : Our results demonstrated a meridian interaction between BL60 acupoint in the bladder channel and Inferior mesenteric sympathetic nerve related to the bladder. This fact suggest that BL60 acupuncture have effect on the bladder through the nerve system. Meanwhile, IMNA was decreased during HT8 acupuncture. This result is supposed HT8 to have not meridian function but acupoint function by another mechanism. It needs to be closely examined other meridians and nerve by the optimal approaching method.

  • PDF

Packet Error Rate Characteristics of an Optical Packet Switching Node with an Optical Packet Address Processor Using an EDFA Preamplifier (광 패킷 어드레스 처리기에 EDFA 전치 증폭기를 사용한 광 패킷 교환 노드의 패킷 오율 특성)

  • 윤찬호;백승환;신종덕
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.23 no.7
    • /
    • pp.1777-1784
    • /
    • 1998
  • The packet error rates of an optical packet switching node with an optical address processor using an EDFA in order to detect M-ary correlation pulses at a fiber-optical delay line matched filter output have been evaluated. Effects of A PIN diode NEP, the gain and noise figure of the EDFA, and the bandwidth of an optical filter on the packet error rate of the switching node have been compared. There is negligible error rate change depending upon the variation of the PIN diode NEP and the EDFA gain. If the bandwidth of the optical filter is below 10 times of the data rate, there is no appreciable effect on the error rate. If the noise figure of the EDFA increases, however, the power penalty increases as much as the noise figure increment at all the bit rates and for address code sets considered in this work.

  • PDF

A Reconfigurable Analog Front-end Integrated Circuit for Medical Ultrasound Imaging Systems (초음파 의료 영상 시스템을 위한 재구성 가능한 아날로그 집적회로)

  • Cha, Hyouk-Kyu
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.51 no.12
    • /
    • pp.66-71
    • /
    • 2014
  • This paper presents an analog front-end integrated circuit (IC) for medical ultrasound imaging systems using standard $0.18-{\mu}m$ CMOS process. The proposed front-end circuit includes the transmit part which consists of 15-V high-voltage pulser operating at 2.6 MHz, and the receive part which consists of switch and a low-power low-noise preamplifier. Depending on the operation mode, the output driver in the transmit pulser can be reconfigured as the switch in the receive path and thus the area of the overall front-end IC is reduced by over 70% in comparison to previous work. The designed single-channel front-end prototype consumes less than $0.045mm^2$ of core area and can be utilized as a key building block in highly-integrated multi-array ultrasound medical imaging systems.

Neurologic Study of SP6(Sanyinjiao, 三陰交) Acupuncture on Bladder parasympathetic Nerve, Tibial Nerve and Blood Pressure in Rats (삼음교(三陰交) 침자(鍼刺)가 부교감신경(副交感神經)의 방광분지(膀胱分枝), 경골신경(脛骨神經) 및 혈압(血壓)에 미치는 영향(影響))

  • Park, Chun-Ha;Yoon, Yeo-Choong;Na, Chang-Su
    • Journal of Acupuncture Research
    • /
    • v.19 no.1
    • /
    • pp.175-188
    • /
    • 2002
  • Objective : The effects of SP6(Sanyinjiao, 三陰交) acupuncture stimulation on bladder parasympathetic nerve activity (PNA), tibial nerve activity (TNA) as well as blood pressure were examined in anesthetized rats and the results are as follows. Methods : The parasympathetic nerve leading to the bladder was exposed retroperitoneally, and the tibial nerve in the hindlimb was exposed through inguinal area. PNA and TNA were recorded using a bipolar platinum-iridium wire electrode and it was connected to preamplifier. Blood pressure was measured using cannula that was inserted into femoral artery and was recorded with blood pressure sensor that is connected with transducer amplifier. The mean value of all parameters measured for 30 seconds before the stimulation was expressed as 100%. An acupuncture needle was inserted into the SP6 region to a depth of 4 mm. Results : Under intact state (IS), acupuncture stimulation for 120 seconds induced significant increase of PNA which was accompanied with decrease of blood pressure. At the same time, TNA showed temporary increase only with acupuncture stimulation. In 4 mg/kg of naloxone-administrated state (NAS), significant decrease of PNA was seen and it was accompanied with increase of blood pressure. TNA also showed temporary increase only with acupuncture stimulation under the NAS just like the IS. Conclusion : consider that SP6(Sanyinjiao, 三陰交) acupuncture stimulation activated parasympathetic nerve and caused vasodilation to lead into the diuresis, but naloxone reversed the effect of acupuncture for antidiuresis.

  • PDF

Study of Radiation Mapping System for Water Contamination in Water System (방사능 수치 오염 지도 작성을 위한 방사선 계측 시스템 연구)

  • Na, Teresa W.;Kim, Han Soo;Yeon, Jei Won;Lee, Rena;Ha, Jang Ho
    • Journal of Radiation Industry
    • /
    • v.5 no.2
    • /
    • pp.185-189
    • /
    • 2011
  • As nuclear industry has been developed, a various types of radiological contamination has occurred. After 9.11 terror in U.S.A., it has been concerned that terrorists' active area has been enlarged to use nuclear or radioactive substance. Recently, the most powerful earth-quake stroke, which triggered a massive tsunami in Japan and then Fukushima nuclear power plant reactor has suffered from a serious accident in history. The Fukushima reactor accident has occurred an anxiety of radiation leaks and about 170,000 people have been evacuated from the accidental area near the nuclear power plant. For these reasons, a social chaos can be occurred if radiological contamination occurs to the supply system for the drinking water. As such, the establishment of the radiation monitoring system for the city main water system is compelling for the national security. In this study, a feasibility test of radiation monitoring system which consists of unified hybrid-type radiation detectors was experimented for multi detection system by using gamma-ray imaging. The hybrid-type radiation sensors were fabricated with CsI(Tl) scintillators and photodiodes. A preamplifier and amplifier was also fabricated and assembled with the sensor in the shielding case. For the preliminary test of detection of radiological contamination in the river, multi CsI(Tl)-PIN photodiode radiation detectors and $^{137}Cs$ gamma-ray source were used. The DAQ was done by Linux based ROOT program and NI DAQ system with Labview program. The simulated contamination was assumed to be occurred at Gapcheon river in Daejeon city. Multi CsI(Tl)-PIN photodiode radiation detectors were positioned at the Gapcheon river side. Assuming that the radiological contaminations flows in the river the $^{137}Cs$ gamma-ray source has been moved and then, the contamination region was reconstructed.

Development of Multi-channel Fiber Laser and Beam Alignment Method (다채널 광섬유 레이저 및 다중 빔 정렬 기술 개발)

  • Kim, Youngchan;Ryu, Daegeon;Noh, Young-Chul
    • Korean Journal of Optics and Photonics
    • /
    • v.33 no.6
    • /
    • pp.245-251
    • /
    • 2022
  • We have developed a multi-channel fiber laser for tiled laser beam combining and a laser output array system for multi-beam alignment. The fiber laser is a master oscillator power amplifier configuration that has a common seed, a preamplifier, and a 7-channel amplifier. The output power of each channel is more than 10 W. The laser output array system is a packed cylindrical configuration for a high fill-factor, and it has capabilities for collimation and tilt control with built-in PZT. Multi-beam alignment to a target is successfully implemented using PZT controlled with a stochastic parallel gradient descent (SPGD) algorithm.