• 제목/요약/키워드: Pre-heater

검색결과 75건 처리시간 0.024초

레이저 기반 플라즈모닉 어닐링을 통한 은 나노입자 자가 생성 및 소결 공정과 이를 활용한 메탈메쉬 전극 기반 투명 웨어러블 히터 (Ag Nanoparticle Self-Generation and Agglomeration via Laser-Induced Plasmonic Annealing for Metal Mesh-Based Transparent Wearable Heater)

  • 황윤식;남의연;김연욱;우유미;허재찬;박정환
    • 한국전기전자재료학회논문지
    • /
    • 제35권5호
    • /
    • pp.439-444
    • /
    • 2022
  • Laser-induced plasmonic sintering of metal nanoparticles (NPs) is a promising technology to fabricate flexible conducting electrodes, since it provides instantaneous, simple, and scalable manufacturing strategies without requiring costly facilities and complex processes. However, the metal NPs are quite expensive because complicated synthesis procedures are needed to achieve long-term reliability with regard to chemical deterioration and NP aggregation. Herein, we report laser-induced Ag NP self-generation and sequential sintering process based on low-cost Ag organometallic material for demonstrating high-quality microelectrodes. Upon the irradiation of laser with 532 nm wavelength, pre-baked Ag organometallic film coated on a transparent polyimide substrate was transformed into a high-performance Ag conductor (resistivity of 2.2 × 10-4 Ω·cm). To verify the practical usefulness of the technology, we successfully demonstrated a wearable transparent heater by using Ag-mesh transparent electrodes, which exhibited a high transmittance of 80% and low sheet resistance of 7 Ω/square.

온·습도 조건이 전자 복사용지의 물리적 특성에 미치는 영향 (Effects of Temperature and Relative Humidity on the Physical Properties of Electronic Copying Paper)

  • 강광호;김형진
    • 펄프종이기술
    • /
    • 제44권3호
    • /
    • pp.70-78
    • /
    • 2012
  • For evaluating the printing suitability of electronic copying papers in the aspect of climate conditions, 12 samples of copying papers being generally used in Korea and worldwide were collected. The copying papers were controlled by various temperature and humidity options in conditioning equipment in order to simulate the specific circumstances of dry, temperate or tropical climate, and the pre-heating system of photocopying machines during printing. As results, some copying papers showed several physical problems, especially in recycled copying papers and a normal paper with original printing faulty. These problems of copying papers were mostly resulted in extremely high moisture circumstance, and in lower levels of tensile strength and tensile stiffness. The moisture contents of copying papers during passing through the pre-heater system of photocopying machine could be rapidly decreased because paper is exposed to high temperature around the pre-heating zone. The copying paper, for example of XR3 sample, containing low moisture contents below 2% had high exfoliating possibility of toner transfer from copying paper.

A Study on Diesel Engine NOx and Soot Emission Characteristics using Different Fuel Oils

  • Nam, Jeong-Gil;Kang, Dae-Sun
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제32권7호
    • /
    • pp.1080-1088
    • /
    • 2008
  • This paper addresses some concerns faced by the shipping industry nowadays. Initially, the environmental issues were resolved and stricter regulations are now being implemented with regards to the exhaust gas, specifically nitrogen oxides (NOx) and sulfur oxides (SOx), emitted from ships. Secondly, with the increasing and unstable cost of fuel oils in the world market, it has become almost a necessity to explore on a new alternative fuel. Hence, this study was conducted. An experiment was carried-out on a fishing survey vessel with the main engine (M/E) and generator engine (G/E) operated on expensive marine gas oil (MGO). During the experiment, two pre-refinery systems were installed and different fuel oil samples were employed for the M/E and the G/E. Furthermore, the NOx emission and soot concentration were monitored and verified. The results confirmed the compatibility of some fuel oil types to the engines and meeting the emission standards. MDO, MF15 and Bunker A can be used in place of MGO for the engines(M/E, G/E).

재생연료의 MILD연소기술 (MILD Combustion Technology for Recycled Fuel)

  • 심성훈;정상현;이상섭
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2010년도 춘계학술대회 초록집
    • /
    • pp.205.2-205.2
    • /
    • 2010
  • Optimum operation conditions of low-NOx MILD combustion for gaseous and solid fuels have been investigated by experimental and computer simulation. Loop reactor type MILD combustor without air pre-heater has been used in the present work. The results show that the balance of injection velocities of fuel and surrounding air is major factor for maintaining MILD combustion mode. Temperature difference between lower and upper part can be reduced less than 20 degree of Celsius. It was found that NOx emission in MILD combustion also can be remarkably reduced to more than 85% in comparison with conventional premixed combustion, and reduced to more than 50% in case of nitrogen and carbon dioxide carrying dried waste water sludge and pulverized coal in comparison with the same of air carrying. It was also found that carbon monoxide emission increase was not appeared at the time of changeover to MILD combustion mode from premixed or air carrying combustion at optimum operation condition.

  • PDF

TFT LCD 제조용 대면적 Magnetron Sputtering 장치 설계와 Al 성장막 특성 조사 (Design of a Large Magnetron Sputtering System for TFT LCD and Investigation of Sputtered AI Film Properties)

  • 유운종
    • 한국진공학회지
    • /
    • 제2권4호
    • /
    • pp.480-485
    • /
    • 1993
  • Factros considered building the magnetron sputtering system for TFT LCD (thin film transistor liquid crystal display0 metallization were thin film thichnes uniformity, temperature uniformity and the pressure gradient of sputtering gas flow in vacuum chamber, base pressure, and the stability fo the carrier moving . The system was consisted of a deposition chamber, a pre-heating chamber, a RF-precleaning chamber and a load/unload lock chamber. The system was designed to handle a substrate with dimension of 400$\times$400mm. The temperautre uniformity of a heater table developed showed $250 ^{\circ}C\pm$5% accuracyon the substrate glass. A base pressure of 1.8 $\times$10-7 torr was obtained after 24 hours pumping with a cryo pump. After an aluminum target was installed in a sputtering source and the film wa sdeposited on the glass, the uniformity, reflectivity and sheet resistance of the deposited film were measured.

  • PDF

헬리컬코일형 $CO_2$ 가스쿨러의 열전달과 압력강하 (Heat Transfer and Pressure Drop of $CO_2$ Gas Cooler in a Helically Coiled Tube)

  • 경남수;유태근;손창효;오후규
    • 한국마린엔지니어링학회:학술대회논문집
    • /
    • 한국마린엔지니어링학회 2005년도 후기학술대회논문집
    • /
    • pp.246-247
    • /
    • 2005
  • The paper presents the heat transfer characteristics during cooling process of carbon dioxide($CO_2$) in a helically coiled tube. The main components of the apparatus consist of a receiver, a variable speed pump, a mass flowmeter, a pre-heater, a gas cooler(test section) and an isothermal tank. The test section with the inner diameter 4.55 [mm] is a tube in tube type heat exchanger with refrigerant flowing in the inner tube and water flowing in the annulus. The main results were summarized as follows : The heat transfer coefficient increases with respect to the decrease of the gas cooler pressure in a supercritical region and the increase of the refrigerant mass flux. The pressure drop decreases in increases of the gas cooler pressure and increases with respect to increases the refrigerant mass flux.

  • PDF

25 kW급 용융 탄산염 연료 전지 스택의 상압 및 가압 운전 (Atmospheric and Pressurized Operation of a 25 kW MCFC Stack)

  • 고준호;서혜경;임희천
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2000년도 춘계학술대회논문집B
    • /
    • pp.264-269
    • /
    • 2000
  • As a part of the ongoing effort towards commercial application of high-temperature fuel cell power generation systems, we have recently built a pilot-scale molten carbonate fuel cell power plant and tested it. The stack test system is composed of diverse peripheral units such as reformer, pre-heater, water purifier, electrical loader, gas supplier, and recycling systems. The stack itself was made of 40cells of $6000cm^2$ area each. The stack showed an output higher than 25kW power and a reliable performance at atmospheric operation. A pressurized performance was also tested, and it turned out the cell performance increased though a few cells have shown a symptom of gas crossover. The pressurized operation characteristics could be analyzed with numerical computation results of a stack model.

  • PDF

원형 세관내 대류비등열전달에 관한 실험적 연구 (An Experimental Study of Flow Boiling Heat Transfer inside Small-Diameter Round Tubes)

  • 추원호;방광현
    • 설비공학논문집
    • /
    • 제16권8호
    • /
    • pp.748-755
    • /
    • 2004
  • Flow boiling heat transfer in small-diameter round tubes has been experimentally studied. The experimental apparatus consisted mainly of refrigerant pump, condenser, receiver, test section of a 1.67 mm inner-diameter round tube and pre-heater for control of refrigerant quality at the inlet of test section. To investigate the effect of bubble nucleation site characteristics of different tube materials, three different tubes of copper, aluminum and brass were used. The ranges of the major experimental parameters were 5∼30 ㎾/$m^2$ of the wall heat flux, 0.0∼0.9 of the inlet vapor quality and the refrigerant mass flux was fixed at 600 kg/$m^2$s. The experimental results showed that the flow boiling heat transfer coefficients in small tubes were affected only by heat flux, but independent of mass flux and vapor quality. The effect of tube material on flow boiling heat transfer was observed small.

석회석미분말을 혼입한 초저발열 매스콘크리트의 특성에 관한 연구 (An Experimental Study on the Properties of Ultra Low Heat Mass Concrete Containing Limestone Powder)

  • 하재담;김동석;김태홍;이종열;권영호
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2000년도 가을 학술발표회 논문집(II)
    • /
    • pp.1175-1180
    • /
    • 2000
  • Recently, the crack of concrete induced by the heat of hydration of cement is a serious problem for more greater, special and higher strength of concrete structures. The increasing concrete's temperature is mainly caused by the heat of hydration of cement and so, to control the thermal stress of concrete structure is desirable to use low heater material of hydration. There are many methods to diminish the increasing of concrete temperature such as using of low heat cement, addition of fly-ash, application of pre-cooling, etc., and in this study, we evaluate the heating and mechanical properties of ultra low heat mass concrete using Low Heat Portland(KS Type IV) cement with 30% of limestone powder. The results of this study will be applied to side wall and bottom of No. 15 and 16 of underground LNG tank in Inchon.

25 kW급 전력사업용 MCFC 발전시스템 구성 및 운전평가 (Constitution and Operation of the 25 kW Molten Carbonate Fuel Cell Power Generation System for Power Utility)

  • 임희천;안교상
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2000년도 하계학술대회 논문집 B
    • /
    • pp.687-689
    • /
    • 2000
  • Molten Carbonate Fuel Cell (MCFC) with high electrical efficiency and low environmental effect has been developed for the commercial application of power generation fields. Recently we have built a 25 kW molten carbonate fuel cell power generation system and tested it. The MCFC system is composed of diverse peripheral units such as reformer, pre-heater, water purifier. electrical loader, gas supplier, and recycling systems. The stack itself was made of 40 cells of $6.000 cm^2$ area each. The stack showed an output of 28.6 kW power and a reliable performance at atmospheric operation. while in pressurized operation the stack showed an output 25.6 kW lower than the atmospheric operation. The reason of lower performance of pressurized operation was caused from a gas cross over shown in few cells in the stack.

  • PDF