• Title/Summary/Keyword: Pre-charger

Search Result 6, Processing Time 0.02 seconds

Life Cycle Assessment of Mobile Phone Charger Containing Recycled Plastics (재생 플라스틱을 적용한 휴대폰 충전기 전과정평가)

  • Heo, Young-chai;Bae, Dae-sik;Oh, Chi-young;Suh, Young-jin;Lee, Kun-mo
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.39 no.12
    • /
    • pp.698-705
    • /
    • 2017
  • Environmental impact of a mobile phone charger containing recycled plastic was quantified using LCA and the environmental benefits from the use of recycled and virgin plastic were compared. The assessment considers potential environmental impacts across the whole life cycle of the charger including; pre-manufacturing; manufacturing; distribution; product use; and end-of-life stages and quantified six environmental impact categories; Abiotic depletion; Acidification; Eutrophication; Global warming; Ozone layer depletion; and Photochemical oxidants creation. The study showed that the environmental impacts of the use stage accounted for 94.4% and 70% in the resource depletion and global warming impact categories, respectively, and the environmental impacts of the pre - manufacturing stage accounted for more than 98% in the other impact categories. The main cause of the environmental impacts in the use stage was electricity consumed by the charger. The main cause in the pre-manufacturing stage was PBA (Printed Board Assembly) and external case manufacturing. In order to quantify the environmental benefits of recycled PC (Polycarbonate) in the exterior case, the environmental impacts of 1 kg production of recycled PC and virgin PC were evaluated. The environmental impact on the abiotic depletion of the recycled PC is estimated to be 30% compared to the virgin PC, and the impacts on the other impact categories of the recycled PC were less than 5% of the virgin plastic. Sensitivity analysis was performed for 12 items including site data and assumptions made. The sensitivity of each item was less than 10%. The results of this study confirm that designing compact and light PBA, improving charging efficiency, and use of recycled plastic are important design factors to reduce the environmental impact of a charger.

Improvement of Initial Operating Characteristics of SCALDO Regulator by Pre-charger (사전충전모드를 통한 SCALDO 레귤레이터의 초기 동작특성 개선)

  • Kwon, O-Soon;Son, Joon-Bae;Song, Jong-Gyu
    • Journal of IKEEE
    • /
    • v.20 no.3
    • /
    • pp.265-272
    • /
    • 2016
  • A SCALDO(Supercapacitor Assisted LDO) regulator is a newly studied regulator to improve the efficiency of a LDO regulator. Commonly a LDO regulator has very low efficiency and a SCALDO regulator can improve it considerably because this regulator can reuse meaninglessly wasted energy at the LDO regulator by a supercapacitor witch is attached between input and a LDO regulator. However this regulator has several challenges because it is a being studied regulator. One of them is an overvoltage issue. At initial operating of this regulator, a supercapacior is totally discharged and input is connected with a supercapacitor and a LDO regulator in series. Thus, input voltage is enabled to a LDO regulator and this input voltage is a significant value to a LDO regulator because commonly input voltage is bigger than twice output voltage. In this paper, to solve this overvoltage issue, we proposed a new SCALDO regulator that has a pre-charger for charging a supercapacitor before starting operation. And we found that a proposed SCALDO regulator can properly reduce overvoltage of a LDO regulator through experiments.

Effectiveness of a Workplace Walking Program Using a Fitness Tracker Including Individual Counseling and Tailored Text Messaging (피트니스 트래커를 활용한 사업장 걷기운동 프로그램의 효과: 개별 상담과 맞춤형 문자메시지 적용)

  • Jung, Mira;Ha, Yeongmi
    • Research in Community and Public Health Nursing
    • /
    • v.30 no.3
    • /
    • pp.257-270
    • /
    • 2019
  • Purpose: This study is designed as a non-equivalent, control group pre/post-test for identifying effectiveness of a workplace walking program using a fitness tracker including individual counseling and tailored text messaging. Methods: Seventy-nine employees from two large companies were allocated into an intervention group (n=39) and a control group (n=40). Participants were asked to wear a fitness tracker (Fitbit Charger HR) during 24-hour, 5-days per week, for 10 weeks. The intervention group was provided with daily walking steps measured by Fitbit, weekly counseling with a specifically designed workbook, and seven weekly text messaging, and the control group with the fitness tracker only. Results: At the week 10 measurement, there were significant differences between the intervention and control groups in physical activity self-efficacy (p<.001), physical activity behavior (p<.001), daily walking steps (p<.001), systolic blood pressure (p=.033), and wellness (p<.001). Conclusion: These results suggest that the workplace walking program using a fitness tracker including individual counseling and tailored text messaging is more effective for persons with 10,000 steps/day. Therefore, it is recommended to actively apply this workplace walking program to inactive employees for encouraging regular physical activities and improving their wellness.

Nano Particle Charging Characteristics of Aerosol Charge Neutralizers (에어로졸 중화기의 나노 입자 하전 특성)

  • Ji, Jun-Ho;Bae, Swi-Nam;Hwang, Jung-Ho
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.27 no.10
    • /
    • pp.1489-1497
    • /
    • 2003
  • Aerosol charge neutralizers with various radioactive sources have been used to apply an equilibrium charge distribution to aerosols of unknown charge distribution. However, the performance of aerosol charge neutralizers is not well known, especially for highly charged particles. Measurements of highly charged particles are needed in air cleaning devices, e.g. electrostatic precipitator, bag filter with a pre-charger, and electrical cyclone. In this study, the particle charging characteristics of two different aerosol charge neutralizers were experimentally investigated for singly charged monodisperse particles and highly charged polydisperse particles. One has radioactive source of $^{85}$ Kr (beta source, 2 mCi) and the other has $^{210}$ Po (alpha source, 0,5 mCi). The air flow rate passing through each aerosol charge neutralizer was changed from 0.2 to 2.5 L/min. The results show that the charge distribution of singly charged monodisperse particles passing through the $^{85}$ Kr aerosol charge neutralizer is well agreed with the Boltzmann equilibrium charge distribution at an air flow rate of 0.3 L/min, However, it deviates from the equilibrium charge distribution when the air flow rates are 0.6, 1,0, and 1,5 L/min, On the other hands, the effect of air flow rate is insignificant for the $^{210}$ Po aerosol charge neutralizer. The non-equilibrium character in charge distribution of highly charged polydisperse particles passing through the $^{85}$ Kr aerosol charge neutralizer greatly depends on the air flow rate, however it is insensitive to the air flow rate for the $^{210}$ Po aerosol charge neutralizer.

The study on collection efficiency of two-stage electrostatic precipitator using non-metallic electrode for improve corrosion resistance and light weight (내부식성과 경량성 향상을 위한 비금속 재질 집진판의 2단 전기집진기 집진효율 연구)

  • An, So-Hee;Lee, Yeawan;Kim, Ye-Sle;Kim, Yong-Jin;Han, Bangwoo;Kim, Hak-Joon
    • Particle and aerosol research
    • /
    • v.17 no.2
    • /
    • pp.21-27
    • /
    • 2021
  • We developed non-metallic electrodes that can replace metallic electrodes of the electrostatic precipitator(ESP) for the purpose of light weight, corrosion resistance, cost reduction. We manufactured three types of collection electrodes made of stainless steel (M), Carbon ink coating layer-Plastic sheet-Carbon ink coating layer (CPC), and Plastic sheet-Carbon ink coating layer-Plastic sheet (PCP). We studied the collection efficiency of a two-stage ESP using oil mist particles with and without collection stage by changing the flow rate, the material of collection electrode, and the applied voltage of the pre-charger module and the collection module. Here we measured concentrations of particles at diameters of 0.45 ㎛ (CMD; count median diameter) and 3.0 ㎛ (MMD : mass median diameter), as well as PM2.5 and PM10. As a result of the experiment, two-stage ESP had 22~25% higher collection efficiency in PM2.5 than one-stage ESP at the same applied voltage. The difference in collection efficiency by varying the materials of collection electrodes was less than 5%. The weight of the non-metallic electrode was only one eighth the weight of the metal electrode. CPC electrode had a thickness of 0.27 mm, which was 1.5 times thinner than a thickness of PCP electrode, so when the flow rate increased, the CPC electrodes couldn't be kept at equal intervals due to the fluttering unlike PCP electrodes. In addition, the PCP-CPC collection module of the present experiment followed the theoretical efficiency based on Deutsch equation and Cochet's charging theory.

A Study on collection efficiency of two-stage electrostatic precipitator using PET-coated non-metallic electrode with respect to relative humidity (PET 코팅된 비금속 집진판을 사용한 2단 전기집진기의 상대습도에 따른 집진효율 연구)

  • Haneol Lee;Gwangtaek Lee;So-Hee An;Ye Won Park;Gunhee Lee;Kee Jung Hong;Inyong Park;Sang Bok Kim;Daehoon Park;Yeawan Lee;Dong-Keun Song;Yong-Jin Kim;Bangwoo Han;Hak-Joon Kim
    • Particle and aerosol research
    • /
    • v.19 no.3
    • /
    • pp.53-62
    • /
    • 2023
  • This study compared the collection efficiency of a two-stage electrostatic precipitator (ESP) with a lightweight PET film-coated carbon electrode collector plate, depending on the relative humidity of the exhaust gas and the applied voltage to the pre-charger. It was confirmed that the onset voltage at which corona discharge occurs decreases and the discharge current decreases at the same voltage as the relative humidity increases. On the other hand, even though there was almost no change in the diameter of the particles generated depending on the relative humidity, the efficiency was higher at the same voltage as the relative humidity increased. In addition, by applying a two-stage ESP structure, the collection efficiency was higher than that of a single-stage electrostatic precipitator under the same conditions. The ESP using the carbon electrode coated with PET film used in this study is expected to be effective in various aspects such as weight and in the current situation where environmental regulations are rapidly tightening.