• 제목/요약/키워드: Pre-calibration

검색결과 162건 처리시간 0.024초

Improvement of Earth Gravity Field Maps after Pre-processing Upgrade of the GRACE Satellite's Star Trackers

  • Ko, Ung-Dai;Wang, Furun;Eanes, Richard J.
    • 대한원격탐사학회지
    • /
    • 제31권4호
    • /
    • pp.353-360
    • /
    • 2015
  • Earth's gravity field recovery was improved after the pre-processing upgrade of the Gravity Recovery And Climate Experiments (GRACE) satellite's star trackers. The star tracker measurements were filtered with a tighter low-pass filtering of 0.025Hz cutoff frequency, instead of a nominal filtering of 0.1Hz cutoff frequency. In addition, a jump removal algorithm was applied to remove discontinuities, due to direct Sun and/or Moon interventions, in the star tracker measurements. During the K-Band Ranging (KBR) calibration maneuvers, large attitude variations could be detected concurrently by both of the star trackers and the accelerometer. The misalignment angles of star trackers between the true frame and the normal frame could be determined by comparing measurements from these sensors. In this paper, new Earth' gravity field maps were obtained using above improvement. Based on comparisons to nominal Earth's gravity field maps, the new Earth's gravity field maps were found better than the nominal ones. Among the applied methods, the misalignment calibration of the star trackers had a major impact on the improvement of the new Earth's gravity field maps.

A Low-Voltage High-Speed CMOS Inverter-Based Digital Differential Transmitter with Impedance Matching Control and Mismatch Calibration

  • Bae, Jun-Hyun;Park, Sang-Hune;Sim, Jae-Yoon;Park, Hong-June
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • 제9권1호
    • /
    • pp.14-21
    • /
    • 2009
  • A digital differential transmitter based on CMOS inverter worked up to 2.8 Gbps at the supply voltage of 1 V with a $0.18{\mu}m$ CMOS process. By calibrating the output impedance of the transmitter, the impedance matching between the transmitter output and the transmission line is achieved. The PVT variations of pre-driver are compensated by the calibration of the rising-edge delay and falling-edge delay of the pre-driver outputs. The chip fabricated with a $0.18{\mu}m$ CMOS process, which uses the standard supply voltage of 1.8 V, gives the highest data rate of 4Gbps at the supply voltage of 1.2 V. The proposed calibration schemes improve the eye opening with the voltage margin by 200% and the timing margin by 30%, at 2.8 Gbps and 1 V.

사용자 상호작용 기반의 시선 검출을 위한 비강압식 캘리브레이션 (Non-intrusive Calibration for User Interaction based Gaze Estimation)

  • 이태균;유장희
    • 한국소프트웨어감정평가학회 논문지
    • /
    • 제16권1호
    • /
    • pp.45-53
    • /
    • 2020
  • 본 논문에서는 웹 페이지 탐색 시 지속해서 발생하는 사용자 상호작용 과정을 이용하여 시선 검출을 위한 캘리브레이션 데이터를 획득하고, 사용자의 시선을 검출하는 동안 자연스럽게 캘리브레이션을 수행하는 방법에 관하여 기술하였다. 제안된 비강압식 캘리브레이션은 획득한 캘리브레이션 데이터를 이용하여 미리 학습된 시선 검출 CNN 모델을 새로운 사용자에 적응하도록 보정하는 과정이다. 이를 위해 훈련을 통해서 시선을 검출하는 일반화된 모델을 만들고 캘리브레이션에서는 온라인 학습 과정을 통해 빠르게 새로운 사용자에 적응하도록 하였다. 실험을 통하여 다양한 사용자 상호작용의 조합으로 시선 검출 모델을 캘리브레이션 하여 성능을 비교하였으며, 기존 방법 대비 개선된 정확도를 얻을 수 있었다.

전력연구원 지진관측자료의 사전자료처리 기법 및 효과적인 활용에 관한 고찰 (Review on Pre-processing of Earthquake Data from KEPRI Seismic Monitoring System)

  • 연관희;박동희;최원학;장천중
    • 한국지진공학회논문집
    • /
    • 제6권2호
    • /
    • pp.39-50
    • /
    • 2002
  • 본 논문에서는 국내의 지진자료를 이용하여 지진특성을 추정하기 전에 적용할 수 있는 사전자료처리기법을 종합적으로 검토하였다. 사전처리 기법으로는 계기보정, 센서검교정상태 확인, 윈도우에 의한 스펙트럼 왜곡 최소화, non-causal ringing에 의한 초동 왜곡 보정 기법을 분석하였으며, 자료 선택시 주파수 영역의 S/N비 확인 및 포화된 자료의 사용가능성 여부를 제시하였다.

하나의 웨이퍼 전체 영상을 이용한 웨이퍼 Pre-Alignment 시스템 (A Wafer Pre-Alignment System Using One Image of a Whole Wafer)

  • 구자명;조태훈
    • 반도체디스플레이기술학회지
    • /
    • 제9권3호
    • /
    • pp.47-51
    • /
    • 2010
  • This paper presents a wafer pre-alignment system which is improved using the image of the entire wafer area. In the previous method, image acquisition for wafer takes about 80% of total pre-alignment time. The proposed system uses only one image of entire wafer area via a high-resolution CMOS camera, and so image acquisition accounts for nearly 1% of total process time. The larger FOV(field of view) to use the image of the entire wafer area worsen camera lens distortion. A camera calibration using high order polynomials is used for accurate lens distortion correction. And template matching is used to find a correct notch's position. The performance of the proposed system was demonstrated by experiments of wafer center alignment and notch alignment.

Reynolds 수가 2단 원추형 5공프로브를 이용한 3차원 유동 측정에 미치는 영향 - 저속 유동장에서의 보정 결과 - (The Effect of Reynolds Number on the Three-Dimensional Flow Measurements with a Two-Stage Cone-Type Five-Hole Probe in a Non-Nulling Mode)

  • 이상우;전상배
    • 대한기계학회논문집B
    • /
    • 제26권1호
    • /
    • pp.27-38
    • /
    • 2002
  • The effects of Reynolds number on the non-nulling calibrations of a cone-type ave-type probe in low-speed flows have been investigated at Reynolds numbers of 2.04$\times$10$^3$, 4.09$\times$10$^3$and 6.13$\times$10$^3$. The calibration is conducted at the pitch and yaw angles in ranges between -35 degrees and 35 degrees with an angle interval of 5 degrees. In addition to the calibration coefficients, reduced pitch and yaw angles, static and total pressures, and velocity magnitude are obtained through a typical non-nulling reduction procedure. The result shows that each calibration coefficient, in general, is a function of both the pitch and yaw angles, so that the pre-existing calibration data in a nulling mode are not enough in accounting far the full non-nulling calibration characteristics. Due to interference of the probe stem, the calibration coefficient are more sensitive to Reynolds number at positive pitch angles than at negative ones. The calibration data reduced in this study may serve as a guide line in the estimation of uncertainty intervals resulted from the Reynolds number effects at low Reynolds numbers.

A 6-Gb/s Differential Voltage Mode Driver with Independent Control of Output Impedance and Pre-Emphasis Level

  • Bae, Chang-Hyun;Choi, Dong-Ho;Ahn, Keun-Seon;Yoo, Changsik
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • 제13권5호
    • /
    • pp.423-429
    • /
    • 2013
  • A 6-Gb/s differential voltage mode driver is presented whose output impedance and pre-emphasis level can be controlled independently. The voltage mode driver consists of five binary-weighted slices each of which has four sub-drivers. The output impedance is controlled by the number of enabled slices while the pre-emphasis level is determined by how many sub-drivers in the enabled slices are driven by post-cursor input. A prototype transmitter with a voltage-mode driver implemented in a 65-nm CMOS logic process consumes 34.8-mW from a 1.2-V power supply and its pre-emphasized output signal shows 165-mVpp,diff and 0.56-UI eye opening at the end of a cable with 10-dB loss at 3-GHz.

Ocean Scanning Multi-spectral Imager (OSMI) Pre-Launch Radiometric Performance Analysis

  • Cho, Young-Min
    • 대한원격탐사학회:학술대회논문집
    • /
    • 대한원격탐사학회 1999년도 Proceedings of International Symposium on Remote Sensing
    • /
    • pp.390-395
    • /
    • 1999
  • Ocean Scanning Multispectral Imager (OSMI) is a payload on the Korean Multi-purpose SATellite (KOMPSAT) to perform worldwide ocean color monitoring for the study of biological oceanography KOMPSAT will be launched in the middle of November this year. The radiometric performance of OSMI is analyzed for various gain settings in the viewpoint of the instrument developer for OSMI calibration and application based on its ground performance measurement data for 8 primary spectral bands of OSMI. The radiometric response linearity and dynamic range are analyzed for the image radiometric calibration and the estimation of OSMI image quality for the ocean remote sensing area. The dynamic range is compared with the nominal input radiance for the ocean and the land. The noise equivalent radiance (NER) corresponding to the instrument radiometric noise is compared with the radiometric resolution of signal digitization (1-count equivalent radiance). The best gain setting of OSMI for ocean monitoring is recommended. This analysis is considered to be useful for the OSMI mission and operation planning, the OSMI image data calibration, and users' understanding about OSMI image quality.

  • PDF

휴대용 혈중pH 측정시스템의 구현 (Development of Portable System for Measuring pH in Blood)

  • 정도운;김우열;배진우;강성철;심윤보;전계록
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 2001년도 하계종합학술대회 논문집(5)
    • /
    • pp.195-198
    • /
    • 2001
  • We developed the portable blood analysis system, which can be measured pH of the blood. This system is composed to electronic circuit, mechanism, and system software. Electronic circuit is composed to the sensor, pre-amp part, temperature regulation part, fluid sensing part, A/D(analog to digital) conversion part, main and peripheral device processing part. And the mechanism is composed to the flow cell and the liquid flow part. The liquid flow part is consisted of blood and washing control system under the control of the 6-channel solenoid valve and syringe rump. The system software is composed to measurement program, calibration program, washing and diagnostic program. The program of each routine is designed as sequential process for an efficiency. And the portable pH analysis system used two-point calibration method using the two types of corrective liquid. As a result, we obtained the calibration curve and calculated the value of pH. For verifying the system, we confirmed the output voltage of the sensor, and estimated reappearance of system using the standard liquid.

  • PDF