• Title/Summary/Keyword: Pre-amplifier

Search Result 164, Processing Time 0.023 seconds

A study of piezoelectric element for AE sensor using PZT ceramics (PZT세라믹을 이용한 AE센서의 압전소자 연구)

  • Kwon, O.D.;Yun, Y.J.;Yoo, J.S.;Kang, S.H.;Lim, K.J.
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2004.05b
    • /
    • pp.173-176
    • /
    • 2004
  • The piezoelectric ceramics for AE sensor piezoelectric devices are desirable to possess higher resonance vibrations. The compositions of $0.9Pb(Zr_xTi_{1-x})O_3-0.1Pb(Mn_{1/3}Nb_{1/3}Sb_{1/3})O_3$ (PZT-PMNS) in this work are selected for obtaining especially large electromechanical coupling factor, high mechanical quality factor and high Curie temperature. This ceramic has higher piezoelectric activity and higher electromechanical coupling factor, but the ceramic has lower Curie temperature. The piezoelectric and dielectric characteristics of PZT-PMNS ternary system are investigated as functions of $Ti^{2+}$, $Zi^{2+}$ mol rate. As the results, MPB(morphotropic phase boundary) in this piezoelectric ceramic is x=0.522. Resonance vibrations of PZT ceramics are investigated as ball-bearing drop test. For the use of AE sensor that driving with pre-amplifier, filter circuit after packed this ceramic and an elastic body.

  • PDF

Multi-channel Unconstrained Heart Rate Monitoring System for Exercising Rehabilitation Patients (재활 훈련중인 환자를 위한 다채널 무구속 심박동수 모니터링 시스템)

  • Cho, J.M.;Choi, J.H.;Park, J.H.;Nam, T.W.;Eun, J.M.
    • Journal of Biomedical Engineering Research
    • /
    • v.29 no.3
    • /
    • pp.191-197
    • /
    • 2008
  • This research focused on the development of wireless telemetry system that can monitor heart rates of multiple rehabilitation patients in real time without constraint. The whole system consists of the multiple patient's side devices (PSDs) and one central monitoring system (CMS). The PSD consists of a microphone, amplifier, filter, microcontroller, and RF (Radio Frequency) modem. In addition, the PSD was designed to be wearable and low power consumption. The CMS consists of an RF modem and general PC and it was designed to monitor heart rates from multiple patients simultaneously. The system warns an alarm signal when a patient's heart rate exceeds the pre-set range for each patient. This system can be useful to monitor the heart rate of exercising rehabilitation patients and control the patients condition and the exercising level.

Characteristics of detecting arc of AE sensor for using PZT ceramics (PZT 세라믹을 이용한 AE센서의 아크 검출 특성)

  • Yoo, J.S.;Kwon, O.D.;Yun, Y.J.;Kang, S.H.;Lim, K.J.
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2004.07a
    • /
    • pp.515-518
    • /
    • 2004
  • The Piezoelectric ceramics for AE(Acoustic Emission) sensor are desired large electromechanical coupling factor, high mechanical quality factor and good characteristic resonance frequency. In this study, the empirical formula of specimens is used $0.9Pb(Zr_xTi_{1-x})O_3-0.1Pb(Mn_{1/3}Nb_{1/3}Sb_{1/3})O_3$ (PZT-PMNS). The piezoelectric and dielectric characteristic are investigated by sintering temperature and value of x as functions of $Ti^{2+},\;Zi^{2+}$ mol rate. MPB(morphotropic Phase boundary) is defined in the x=0.522. Because it is appeared to the best piezoelectric and dielectric characteristic in the x=0.522, it can be application by AE sensor. PZT-PMNS ceramics without pre-amplifier and filter are tested for detecting of arc signal. The detection characteristic is evaluated wave form, frequency distribution.

  • PDF

Minimum detectable activity of plastic scintillator for in-situ beta measurement system in ground water

  • Choi, Woo Nyun;Lee, UkJae;Bae, Jun Woo;Kim, Hee Reyoung
    • Nuclear Engineering and Technology
    • /
    • v.51 no.4
    • /
    • pp.1169-1175
    • /
    • 2019
  • The minimum detectable activity (MDA) value was derived according to the flow rate of the sample and degree of amplification of the device by sending the sample directly from the collection site to the detection part through a pump. This method can lead to reduction in time and cost compared to the existing measurement method that uses a pre-treatment process. In this study, experiments were conducted on $^3H$ and $^{90}Sr$, which are the major pure beta-emitting radionuclides, by setting the sample flow rate and the amplification gain as factors. The MDA values were derived according to the flow rates, considering that the flow rate can affect the MDA values. There were no change in the MDA under different flow rates of 0, 600, 800, and 1000 mL/min. Therefore, it was confirmed that the flow rate may not be considered when collecting samples for monitoring in actual field. As the degree of amplification of the amplifier increased, the time required to reach the target MDA decreased. When the amplification was quadrupled, the detection efficiency increased by approximately 23.4 times, and the time to reach the MDA decreased to approximately 1/550 times. This method offers the advantage of real-time on-site monitoring.

A 4-channel 3.125-Gb/s/ch VCSEL driver Array (4-채널 3.125-Gb/s/ch VCSEL 드라이버 어레이)

  • Hong, Chaerin;Park, Sung Min
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.54 no.1
    • /
    • pp.33-38
    • /
    • 2017
  • In this paper, a 4-channel common-cathode VCSEL diode driver array with 3.125 Gb/s per channel operation speed is realized. In order to achieve faster speed of the switching main driver with relatively large transistors, the transmitter array chip consists of a pre-amplifier with active inductor stage and also an input buffer with modified equalizer, which leads to bandwidth extension and reduced current consumption. The utilized VCSEL diode provides inherently 2.2 V forward bias voltage, $50{\Omega}$ resistance, and 850 fF capacitance. In addition, the main driver based upon current steering technique is designed, so that two individual current sources can provide bias currents of 3.0 mA and modulation currents of 3.3 mA to VCSEL diodes. The proposed 4-channel VCSEL driver array has been implemented by using a $0.11-{\mu}m$ CMOS technology, and the chip core occupies the area of $0.15{\times}0.18{\mu}m^2$ and dissipates 22.3 mW per channel.

A Study on the Control System Implementation of Human Body Nerves Signal (인체 신경신호 제어시스템 구현에 관한 연구)

  • Ko, Duck-Young;Kim, Sung-Gon;Choi, Jong-Ho
    • 전자공학회논문지 IE
    • /
    • v.43 no.1
    • /
    • pp.16-24
    • /
    • 2006
  • This paper is aimed to develope of an integrated BCI(Brain Computer Interface System) that make possible for simultaneous multichannel data process and used extra cellular neural activity from the vestibular system instead of electroencephalogram signals for more precision control. The electrical properties pre-amplifier are 47.6 dB of gain, 0.005 % of distortion at 100 Hz, 12M$\Omega$ of input impedance. Window discriminator used two CPU with difference role to increase processing speed so that sampling frequency was 87 kHz. The designed window discriminator has more not only two times in signal resolution power but also ten times in error discrimination power than commericially available discriminator. The proposed method decreases 100 times in amount of integrated data then BCI system during 100 ms.

STRAIN CHANGES OF ACRYLIC RESIN SPECIMENS CURED BY THREE CURING CYCLES

  • Kang, In-Ho;Kim, Yung-Soo;Kim, Chang-Whe
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.40 no.3
    • /
    • pp.236-245
    • /
    • 2002
  • The acrylic resin was first introduced as denture base materials in 1937 and it is commonly used for denture base fabrication nowadays. Three different curing cycles (Conventional curing cycle, short curing cycle and long curing cycle) and three commercially available heat-activated acrylic resins (Vertex RS, Lucitone 199 and ProBase Hot) were investigated to find the curing cycle and material that showed the minimum shrinkage of the resin during polymerization process. A brass master mold was fabricated and duplicated by additional silicone impression material. Stone molds were made by pouring of type III dental stone (SILKY-ROCK YELLOW, Whip-Mix, Louisville, Kentucky). It was embedded in the flask. Strain gauge and thermocouple were embedded in the specimen. Strain gauge and thermocouple were connected to signal conditioning amplifier and data was recorded by pre-programmed software. The parameters ESmax (Maximum expansion strain), Sb (Strain measured just before deflasking procedure), Sa (Strain measured just after deflasking procedure) and Sf (Strain measured at the end of the experiment) were measured. ${\Delta}$S was calculated from Sb and Sa (${\Delta}$S=Sb-Sa). In the experiment concerned about materials, the parameters 90-ESmax (Maximum expansion strain measured during early 90 minutes of curing procedure), 180-ESmax (Maximum expansion strain measured from 90 minutes to 180 minutes), Sb, Sa, ${\Delta}$S and Sf were measured and the following conclusions were made. 1. The ESmax value of conventional curing cycle showed the largest value and the 180-ESmax value of Lucitone 199 showed the smallest value. 90-ESmax values showed no significant difference (p<0.05). 2. ${\Delta}$S values of conventional curing cycle showed the positive values. ${\Delta}$S values of short curing cycle and long curing cycle showed the negative values. All three materials cured by conventional curing cycle showed the positive values. 3. The Sf values of long curing cycle and ProBase Hot (cured by conventional curing cycle) showed the smallest values.

An Integrated Si BiCMOS RF Transceiver for 900MHz GSM Digital Handset Application (II) : RF Transmitter Section (900MHz GSM 디지털 단말기용 Si BiCMOS RF 송수신 IC 개발 (II) : RF 송신단)

  • Lee, Kyu-Bok;Park, In-Shig;Kim, Jong-Kyu;Kim, Han-Sik
    • Journal of the Korean Institute of Telematics and Electronics S
    • /
    • v.35S no.9
    • /
    • pp.19-27
    • /
    • 1998
  • The Transmitter part of single RF transceiver chip for an extended GSM handset application was circuit-designed, fabricated adn evaluated. The RF-IC Chip was processed by 0.8${\mu}m$ Si BiCMOS, 80 pin TQFP of $10 {\times} 10mm$ size, 3.3V operated RF-IC reveals, in general, quite reasonable integrity and RF performances. This paper describes development resuts of RF transmitter section, which includes IF/RF up-conversion mixer, IF/RF polyphase and pre-amplifier. The test results show that RF transmitter section is well operated within frequency range of 880~915MHz, which is defined on the extended GSM(E-GSM) specification. The transmitter section also reveals moderate power consumption of 71mA and total output power of 8.2dBm.

  • PDF

CHARACTERISTICS OF THE FAIRCHILD 486 CCD AT MAIDANAK ASTRONOMICAL OBSERVATORY IN UZBEKISTAN (우즈베키스탄 Maidanak 천문대 Fairchild 486 CCD의 기본적인 특성)

  • Lim, Beom-Du;Sung, Hwan-Kyung;Karimov, R.;Ibrahimov, M.
    • Publications of The Korean Astronomical Society
    • /
    • v.23 no.1
    • /
    • pp.1-12
    • /
    • 2008
  • Understanding of the basic characteristics of an astronomical instrument is a prerequisite to obtaining reliable data from the instrument. We have analyzed more than 1,000 calibration images from the Fairchild 486 CCD (hereafter the Maidanak 4k CCD system) attached to the AZT-22 1.5m telescope at Maidanak Astronomical Observatory in Uzbekistan. The Maidanak 4k CCD system supports three readout modes through 1, 2, or 4 amplifiers. In most cases observers use 4-amplifier readout mode to save time. We have tested the stability and seasonal variation of zero levels and confirm that two quadrants of the images (Amp 1 & 2) show no appreciable seasonal variation. but the other two quadrants (Amp 3 & Amp 4) show an evident seasonal variation in the bias level. The Cryo Tiger, the cooling system used at the Maidanak 4k CCD system, maintains the CCD temperature at -108'E, and effectively suppresses the dark electrons. The mean value versus the variance plot of the flat images does not show the expected relation for an ideal Poisson noise distribution and this is attributed to the large variation in quantum efficiency between different pixels. In addition, we confirm that there is no appreciable difference in gain between readout amplifiers, but there is a large variation in quantum efficiency across CCD chip especially in U. Due to the finite length of shutter opening and closing time, the effective exposure time varies across the science images. We introduce two parameters to quantify the effect of this uneven illumination and present a method to remove these effects. We also present a method to remove the interference patterns appearing in the images obtained with longer wavelength filters and investigate the spatial variation of the point spread function.

Development of Data Acquistion and Processing System for the Analysis of Biophysiological signal (생체신호 처리를 위한 시스템 개발)

  • 이준하;이상학;신현진
    • Progress in Medical Physics
    • /
    • v.3 no.1
    • /
    • pp.71-78
    • /
    • 1992
  • This study describes the design of the biophysiological signal processing analyzer which can collect and analyze the biosignal raw data. System hardware is consisted of the IBM PC AT. pre-amplifier. AID converter, Counter/Timer. and RS-232C processor. Biophysiological signal data were processed by the software digital filter. FFT and graphic processing routine. The tachogram and FFT of the the peak to peak interval time was accomplished by the Graphic user interface software using the biophysiological signal processed data. Using this system. the powerspectrum of the heart rate variability during the long term could be observed. Experimental results of this system approach our purpose. which is improved the cost performance. easy to use. reducing raw-data noise and optimizing model for digital filter.

  • PDF