• Title/Summary/Keyword: Pre-amplifier

Search Result 164, Processing Time 0.022 seconds

A CMOS 5-bit 5GSample/Sec Analog-to-digital Converter in 0.13um CMOS

  • Wang, I-Hsin;Liu, Shen-Iuan
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • v.7 no.1
    • /
    • pp.28-35
    • /
    • 2007
  • This paper presents a high-speed flash analog-to-digital converter (ADC) for ultra wide band (UWB) receivers. In this flash ADC, the interpolating technique is adopted to reduce the number of the amplifiers and a linear and wide-bandwidth interpolating amplifier is presented. For this ADC, the transistor size for the cascaded stages is inversely scaled to improve the trade-off in bandwidth and power consumption. The active inductor peaking technique is also employed in the pre-amplifiers of comparators and the track-and-hold circuit to enhance the bandwidth. Furthermore, a digital-to-analog converter (DAC) is embedded for the sake of measurements. This chip has been fabricated in $0.13{\mu}m$ 1P8M CMOS process and the total power consumption is 113mW with 1V supply voltage. The ADC achieves 4-bit effective number of bits (ENOB) for input signal of 200MHz at 5-GSample/sec.

Analysis of Various Acoustic Emission Signal for the Automatic Detection of Defective Manufactures in Press Process (프레스 공정에서의 불량품 자동 검출을 위한 다양한 음향방출 신호의 분석)

  • Kim, Dong-Hun;Park, Se-Myung;Lee, Won-Kyu
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.9 no.4
    • /
    • pp.14-25
    • /
    • 2010
  • Small cracks or chips of a product appear very frequently in the course of continuous production of an automatic press process system. These phenomena became the cause of not only defective product but also damage of a press mold. In order to solve this problem AE(Acoustic emission) system was introduced. AE system was expected to be very effective to real time detection of the defective product and for the prevention of the damage in the press molds In this study, for the pick and analysis of AE signals generated from the press process, AE sensors/pre-amplifier/analysis and processing board were used as frequently found in the other similar cases. For the analysis and processing the AE signals picked in real time from the normal or the detective products, specialized software called AE-win(software for processing AE signal from Physical Acoustics Corporation) was used. As a result of this work it was conformed that intensity and shape of the various AE signals differ depending on the weight of the press and thickness of sheet and process type.

Computer Simulation and Control Performance Evaluation for Feedback System of Ultra Positioning by using Laser Interferometer (Laser Interferometer를 이용한 초정밀위치결정 피드백시스템의 컴퓨터 시뮬레이션 및 제어성능 평가)

  • 김재열;이규태;곽이구;한재호;김창현
    • Transactions of the Korean Society of Machine Tool Engineers
    • /
    • v.11 no.1
    • /
    • pp.17-25
    • /
    • 2002
  • This system is composed of fine and coarse apparatus, measurement system and control system. Piezoelectric actuator is designed far fee positioning. We make a study of precision apparatus that is used in the various industrial machine. The study was carried out to develope a precision positioning apparatus, consisting of servo motor and piezoelectric actuator Coarse positioning using lead screw is thrived by servo motor. Control system output a signal from laser interferometer to amplifier of servo motor and piezoelectric actuator after digital signal processing (DSP). Resolution of this apparatus measure with laser interferometer. In this study, design method and control system with ultra precision position apparatus are researched. As the first step, we have estimated for control performance and system stability before an actual apparatus is manufactured by MATLAB with SIMUUNK including various frictions those are composed of pre-design and system modeling.

Determination of Dynamic Crack Initiation Toughness Using Instrumented Charpy Impact Test in WC-Co Alloy (계장화 샬피충격시험을 이용한 WC-Co 초경합금의 동적 균열개시인성치 결정)

  • 이억섭;박원구;홍성경;윤경수
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.19 no.3
    • /
    • pp.688-696
    • /
    • 1995
  • Cemented carbides, best known for their superior mechanical properties such as high strength, high hardness and high wear resistance, have a wide range of industrial applications including metal working tools, mining tools, and wear resistance components. The cobalt has been used as a binder in the WC-based hard composites due to its outstanding wetting and adhesion characteristics even though its expensiveness. Therefore many studies attempted to find a better substitute for cobalt as binder to decrease production costs. This investigation is a pre-step to study dynamic fracture characteristic evaluation of a WC-Co hardmetal were evaluated by using the instrumented Charpy impact testing procedures. It was found that the dynamic characteristics of used strain amplifier were very important experimental factors to extract valid dynamic fracturing data in WC-Co specimens. It was suggested by showing some experimental examples that when we wished to evaluate dynamic fracture toughness for cemented carbide composites by using the instrumented Charpy impact testing procedure, a careful attention must be given to obtain valid results.

Implementation of the BPH Diagnosis System for Home Health Care Using FPGA (FPGA를 이용한 홈 헬스케어용 전립선 비대증 진단시스템 구현)

  • Jeong, Do-Un;Chung, Wan-Young;Kim, Jeong-Kuk
    • Proceedings of the Korea Institute of Convergence Signal Processing
    • /
    • 2006.06a
    • /
    • pp.97-100
    • /
    • 2006
  • A sensor and measuring system were implemented to measure both uroflow and urophonography signal during urination for diagnose the BPH(benign prostatic hypertrophy). The implemented system was composed of the uroflow sensor using the load-cell, the urophonography measurement sensor so as stethoscope type, pre-processing part for sensors signal detection, amplifier and filter, system control parts and PC measurement program. A simulator of the lower urinary system that is experimental equipment implemented for evaluates the developed system. The two signals were measured using implemented system and analyzed these signal by means of time domain and frequency domain for extraction of the characteristic parameter which can most effectively reflected by the occlusion of the lower urinary system. Furthermore two signals were measured and analyzed with the subject of 5 healthy adult for clinical application possibility of the implemented system. As a result, the most influence bandwidth of effect according to occlusion of the lower urinary system is $253{\sim}282Hz$ of the urophonography signal.

  • PDF

Simmyung Laser System and Study on the X-ray Generation (신명 레이저와 X-선 발생 연구)

  • Kong, Hong-Jin;Han, Ki-Gwan;Kim, Nam-Seong;Kim, Hyun-Soo;Um, Ki-Young;Park, Jong-Rak;Lee, Jae-Youg;Shin, Yun-Sup;Han, Ki-Ho
    • Proceedings of the Optical Society of Korea Conference
    • /
    • 1995.06a
    • /
    • pp.185-189
    • /
    • 1995
  • A high-power Nb:glass laser system(Simmyung I) has been contructed and tested. In this system, we used a Nb:YLF laser as a master oscillator, a 4-pass amplifier for pre-amplification, 5 stages of rod amplifiers, and spatial filtering and image reaying usits. The system has demonstrated in excess of 80J(2TW) with 40 psec(FWHM) pulse duration. Output energy, gain and spatial were measured at each amplification stage. With this laser system a preliminary X-ray generation experiment was performed. Pinhole images, X-ray diode signals and X-ray speriment were obtained for the irradiated target of copper. Detailed descriptions of the system performance and the X-tay generation experiment are presented.

  • PDF

Bismuth Coated Carbon Fiber Microelectrode with Gallic Acid n-Propyl Ester for Trace Copper Analysis (비스무스코팅 탄소섬유전극과 갤릭산 착물을 사용한 구리 이온의 흔적량 분석)

  • Ly, Suw-Young;Lee, Chang-Hyun;Jung, Young-Sam
    • Journal of Environmental Science International
    • /
    • v.16 no.10
    • /
    • pp.1111-1118
    • /
    • 2007
  • A bismuth-coated carbon fiber microelectrode was prepared using cyclic voltammetry (CV). An analytical application was performed for the copper analysis with Square Wave Stripping Voltammetry (SWSV). Gallic acid n-propyl ester (PG) was used for the complex formation with a copper ion, and electrochemical measurements were performed with a pre-amplifier of a low-current module for nano am per detection. The effects of various parameters on the response were optimized. Analytical working ranges of $0.03-25.9\;{\mu}gl^{-1}$ and $0-25\'mgl^{-1}$ Cu(II) were obtained. The relative standard deviation at $13\;mgl^{-1}$ Cu was 0.9% (n = 12) in optimum conditions. The detection limit was found to have been $0.019\;{\mu}gl^{-1}$, with a 30-sec accumulation time. The developed methods were applied to a copper assay in water samples.

A 3.3V 8-bit 500MSPS Nyquist CMOS A/D Converter Based on an Interpolation Architecture (Interpolation 기법을 이용한 3.3V 8-bit 500MSPS Nyquist CMOS A/D Converter의 설계)

  • 김상규;송민규
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.41 no.8
    • /
    • pp.67-74
    • /
    • 2004
  • In this paper, a 3.3V 8-bit 500MSPS based on an interpolation architecture CMOS A/D converter is designed. In order to overcome the problems of high speed operation, a novel pre-amplifier, a circuit for the Reference Fluctuation, and an Averaging Resistor are proposed. The proposed Interpolation A/D Converter consists of Track & Hold, four resistive ladders with 256 taps, 128 comparators, and digital blocks. The proposed A/D Converter is based on 0.35um 2-poly 4-metal N-well CMOS technology. The A/D Converter dissipates 440 mW at a 3.3 Volt single power supply and occupies a chip area of 2250um x 3080um.

Measurement of low level sound noise using cross spectrum method (크로스 스펙트럼 기법을 이용한 저레벨 소음의 측정)

  • 박창규;강경일
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.2 no.2
    • /
    • pp.241-248
    • /
    • 1998
  • The accurate measurement of the room sound level is required in environment noise control. However, it has been found that the measurement system noise always corrupts the actual noise from the sound source. In this study, a new sound level measurement technique in which the system noise is eliminated from the measured signal by the cross spectrum method, is proposed. The received signals of two measuring microphones are recorded to DAT through the pre-amplifier and digitized by A/D converter. The cross spectrum calculated from the digitized signals gives the accurate sound level since the system noise is uncorrelated with the sound source noise which we want to measure. The performance of the proposed technique is verified experimentally to be effective and the technique is found to be economic since the low cost general purpose microphone could be used in this technique.

  • PDF

A Study on the Characteristics of PCN-PZT Piezoelectric Acceleration Sensor (PCN-PZT 압전형 가속도센서의 특성에 관한 연구)

  • Kim, Yeong-Deok;Kim, Gwang-Il;Jeong, U-Cheol;Go, Jae-Seok
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.48 no.5
    • /
    • pp.354-360
    • /
    • 1999
  • PCN-PZT piezoelectric acceleration sensors of annular shear mode voltage type were fabricated and their characteristics have been investigated. Field tests are also carried out. To avoid noise problems from the environmental conditions, acceleration sensors employed solid state micro-electronics for pre-amplifier. The calibration procedures based on the principle of the comparison method were adopted for investigating the characteristics of fabricated acceleration sensors. The voltage sensitivity and resonant frequency of fabricated acceleration sensors were 83mv/g, 23kHz, respectively. The lower and upper frequency limit were 4Hz and 9kHz, respectively. The variation of the voltage sensitivity showed 10% at $-406{\circ}C\; and\; 9%\; at\; 121^{\circ}C$ compared to that of reference temperature at $40^{\circ}C$.

  • PDF