• Title/Summary/Keyword: Pre-Mix

Search Result 103, Processing Time 0.021 seconds

Experimental Studies on Influence of Foaming Agents on the Properties of Mortar (기포제가 모르터의 제성질에 미치는 영향에 관한 실험적 연구)

  • Sung, Chan-Yong;Hwang, Eun
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.27 no.1
    • /
    • pp.46-61
    • /
    • 1985
  • This study was performed to obtain the basic data which can be applied to the use of foaming mortars. The data was based on the properties of foaming mortars depending upon various mixing ratios and addings to compare those of cement mortar. The foaming agents which was used at this experiment were pre-foamed type and mix-foaming type which is being used as mortar structures. The foaming mortar, mixing ratios of cement to fine aggregate were 1:1, 1: 2, 1 : 3 and 1 : 4. The addings of foaming agents were 0.0%, 0.5%, 1.0%, 1.5%, 2.0%, 2.5% and 3.0% of cement weight. The results obtained were summarized as follows; 1. At the mixing ratio of 1 : 1, the lowest water-cement ratios were showed by foaming mortars, respectively. But it gradually was increased in poorer mixing ratio and decreased in more addition of foaming agent. The water-cement ratios were decreased up to 1. 8~22. 0% by G, 2. 2~24. 1 % by U and 0. 7~53. 1% by J foaming mortar than cement mortar. 2, At the mixing ratio of 1 : 1, the highest bulk densities were showed by foaming mortars, respectively. But, it gradually was decreased in poorer mixing ratio and more addition of foaming agent. The bulk densities were decreased up to 1. 4~20. 7% by G, 2. 3~23. 7% by U and 26. 5~56. 5% by J foaming mortar than cement mortar. Therefore, foaming mortar could be utilized to the constructions which need low strengths. 3. At the mixing ratio of 1:1, the lowest absorption rates were showed by foaming mortars, respectively. But, it gradually was increased in poorer mixing ratio and more addition of foaming agent. Specially, according to the absorption rate when immersed in 72 hours, the absorption rates were showed up to 1. 01~1. 24 times by G, 1. 03~1. 58 times by U and 1. 10~5. 91 times by J foaming mortar than cement mortar. It was significantly higher at the early stage of immersed time than cement mortar. 4. At the mixing ratio of 1:1, the lowest air contents were showed by foaming mortars, respectively. But, it gradually was increased in poorer mixing ratio and more addition of foaming agent. Air contents were contented up to 4. 0~17. 2 times by G, 5. 2~23. 2 times by U and 23. 8~74. 5 times by J foaming mortar than cement mortar. 5. At the mixing ratio of 1 : 1, the lowest decreasing rates of strengths were showed by foaming mortars, respectively. But, it gradually was increased in poorer mixing ratio and more addition of foaming agent. Specially, the strengths of 28 days were decreased 0. 4~2. 2% than those of 7 days by foaming mortar, respectively. Also, the correlations between compressive and tensile strength, compressive and ending strength, tensile and bending strength were highly significant as a straight line shaped, respectively. 6. The correlations between absorption rate, air content, compressive strength and bulk density, absorption rate, compressive strength and air content were highly significant, respectively. The multiple regression equations of water-cement ratio, bulk density, absorption ate, air content, compressive strength, tensile strength and bending strength were computed depending on a function of mixing ratio and addition of foaming agent. It was highly significant, respectively. 7. At the mixing ratio of 1 : 1, the highest strengths were showed by cement mortar and foaming mortars, by chemical reagents. But, it gradually was decreased in poorer mixing ratio. The decreasing rates of strengths were in order of H $_2$S0 $_4$, HNO$_3$ and HCI, J,U,G foaming mortar and cement mortar. Specially, at the each mixing ratio, each chemical reagent and 3.0% of foaming agent, J foaming mortar was collapsed obviously. Therefore, for the structures requiring acid resistence, adding of foaming agent should be lower than 3.0%.

  • PDF

The Effects of the Intensity of Combined Training on Body Composition, HOMA-IR and HbA1c of Female Students of a Boarding High School (복합운동 강도가 기숙형학교 여고생의 신체조성, HOMA-IR 및 HbA1c에 미치는 영향)

  • Kwon, Sun-Ok;Jeong, Seon-Tae
    • Journal of Life Science
    • /
    • v.20 no.1
    • /
    • pp.124-132
    • /
    • 2010
  • Among students of 'K' boarding high school, located in 'B' city, 32 students whose % body fat was 30% or above were divided into three groups - two exercise groups and one control group. They performed Combined Training - a mix of weight training (WT) and step box training (SBT) - for 65 min a day, 3 days a week, for 8 weeks in total. Group A performed WT 70-80%$RM{\times}3$ sets+SBT (RPE 11-13)${\times}1$ set, and group B performed WT 70-80%$RM{\times}1$ set+SBT (RPE 11-13)${\times}3$ sets to yield data on changes of body composition (Soft Lean Mass, SLM), %fat, WHR), HbA1c, and HOMA-IR. Paired t-test was used to process data within each group. Pre- and post experiment differences rates (%diff) were used to perform one-way ANOVA (Duncan test) for group comparisons. The conclusions derived are as follows. Regarding body composition, exercise groups showed an increase in SLM, but there was no such change in the control group. WHR decreased in group A, but increased in the control group. The % body fat decreased in both exercise groups, but increased in the control group. As for the group comparisons, SLM in group A showed a greater increase than in group B and the control group. WHR in groups A and B showed a greater decrease than the control group. The % body fat in groups A and B showed a greater decrease than the control group. The exercise groups showed a significant decrease in HOMA-IR, but the control group showed a significant increase in HOMA-IR. As for the group comparisons, groups A and B showed a greater decrease in HOMA-IR than the control group. The exercise groups showed a significant decrease in HbA1c, however, the control group showed no change in HbA1c. As for the group comparisons, group A showed a greater decrease in HbA1c than the control group. These results confirm that combined training is more effective in improving body composition and metabolic factors when it includes a high proportion of resistance training, rather than aerobic exercise. The results of the study suggest that it is advisable to set a high proportion of WT when deciding the intensity of combined training.

Determination of plasma C16-C24 globotriaosylceramide (Gb3) isoforms by tandem mass spectrometry for diagnosis of Fabry disease (패브리병(Fabry) 진단을 위한 혈장 중 Globotriaosylceramide (Gb3)의 탠덤매스 분석법 개발과 임상 응용)

  • Yoon, Hye-Ran;Cho, Kyung-Hee;Yoo, Han-Wook;Choi, Jin-Ho;Lee, Dong-Hwan;Zhang, Kate;Keutzer, Joan
    • Journal of Genetic Medicine
    • /
    • v.4 no.1
    • /
    • pp.45-52
    • /
    • 2007
  • Purpose : A simple, rapid, and highly sensitive analytical method for Gb3 in plasma was developed without labor-ex tensive pre-treatment by electrospray ionization MS/ MS (ESI-MS/MS). Measurement of globotriaosy lceramide (Gb3, ceramide trihex oside) in plasma has clinical importance for monitoring after enzyme replacement therapy in Fabry disease patients. The disease is an X-linked lipid storage disorder that results from a deficiency of the enzyme ${\alpha}$-galactosidase A (${\alpha}$-Gal A). The lack of ${\alpha}$-Gal A causes an intracellular accumulation of glycosphingolipids, mainly Gb3. Methods : Only simple 50-fold dilution of plasma is necessary for the extraction and isolation of Gb3 in plasma. Gb3 in diluted plasma was dissolved in dioxane containing C17:0 Gb3 as an internal standard. After centrifugation it was directly injected and analyzed through guard column by in combination with multiple reaction monitoring mode of ESI-MS/MS. Results : Eight isoforms of Gb3 were completely resolved from plasma matrix. C16:0 Gb3 occupied 50% of total Gb3 as a major component in plasma. Linear relationship for Gb3 isoforms w as found in the range of 0.001-1.0 ${\mu}g$/mL. The limit of detection (S/N=3) was 0.001 ${\mu}g$/mL and limit of quantification was 0.01 ${\mu}g$/mL for C16:0 Gb3 with acceptable precision and accuracy. Correlation coefficient of calibration curves for 8 Gb3 isoforms ranged from 0.9678 to 0.9982. Conclusion : This quantitative method developed could be useful for rapid and sensitive 1st line Fabry disease screening, monitoring and/or diagnostic tool for Fabry disease.

  • PDF