• 제목/요약/키워드: Pre-Breakdown

검색결과 79건 처리시간 0.021초

초고압 전력 케이블 절연층의 Flow Pattern 방향각에 따른 전기 트리 개시 특성 비교 (Comparison of Electrical Tree Initiation According to Flow Pattern in EHV Power Cable Insulation)

  • 이승엽;김영호;조대희;이인호;박완기
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1999년도 하계학술대회 논문집 D
    • /
    • pp.1532-1534
    • /
    • 1999
  • Electrical treeing phenomenon, regarded as pre-breakdown which accelerates aging process leading an insulation to the complete breakdown, is with no doubt extremely fatal to the performance of the insulation. Investigated in this paper is electrical treeing representing local dielectric failure according to flow pattern, the flow history of liquid polyethylene formed during the extrusion process. Experiments of electrical tree initiation by means of ramp tests were conducted using newly developed electrode system with point-to-point structure. Constant voltage tests were also carried out with the electrode system to estimate the life time of the insulation. Results were analyzed using statistical method such as Weibull distribution.

  • PDF

제작방법에 따른 전력케이블용 폴리에틸렌 박막의 전기전도특성 (The Electrical Conduction Properties of Polyethylene Thin Film for Power Cable with Manufacturing Methods)

  • 조경순;이용우;이수원;홍진웅
    • E2M - 전기 전자와 첨단 소재
    • /
    • 제10권5호
    • /
    • pp.453-460
    • /
    • 1997
  • In order to investigate the electrical conduction properties of polyethylene thin film for power cable with manufacturing methods, the thickness of specimen was the 30, 100[${\mu}{\textrm}{m}$] of LDPE and 200[${\mu}{\textrm}{m}$] of XLPE were manufactured. The experimental condition for conduction properties was measured until the breakdown occurs at temperature ranges from 30 to 110[$^{\circ}C$] and the electric field from 1$\times$10$^3$to 5$\times$10$^{6}$ [V/cm]. As for increase of temperature, the current density of LDPE was increased with constant ratio in low field, but changes with exponential function in high electric field. The tunnel current of pre-breakdown region is shifted toward low field as much as thermal excitation energy. At low electric field, the XLPE showed dominant electrical conduction properties by thermal excitation, and transformation of the electron was resisted by the crystal at high electric field.

  • PDF

Furnace로 $N_2O$ 분위기에서 성장시킨 Oxynitride 절연막 특성 (Characteristics of Oxynitride Dielectics Prepared in $N_2O$ Ambient by Furnace)

  • 이은구;박인길;박진성
    • 한국세라믹학회지
    • /
    • 제32권1호
    • /
    • pp.31-36
    • /
    • 1995
  • (100) Si was oxidized in N2O ambient, and the film properties of oxynitride dielectrics were compared with pure SiO2. The growth rate, after pre-oxidation in O2/N2 ambient with raising temperature, is faster than that of O2/N2O treatment during the same condition. Nitrogen piles up at the interface of SiO2 and Si substrate and the content is about 2atom%. Comparing with pure SiO2, oxynitride dielectrics shows less dielectric breakdown failures and flat-band voltage shift, and good diffusion barrier property to dopant(BF2) is also observed.

  • PDF

전력케이블용 저밀도폴리에틸렌박막의 전기전도특성 (Electric conduction properties of low density Polyethylene film for Power cable)

  • 황종국;홍능표;이용우;소병문;홍진웅
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 1994년도 추계학술대회 논문집
    • /
    • pp.143-146
    • /
    • 1994
  • In older to investigate the properties of electric conduction in low density polyethylene(LDPE) for power cable, the thickness of specimen was the 30, 100($\mu\textrm{m}$) of LDPE. The experimental condition for conductive properties was measured until the breakdown occurs at temperature ranges from 30 to 110[$^{\circ}C$] and in the electric field of 1 to 5 ${\times}$10$^2$[Mv/m]. As for increase of temperature, the current density of LDPE was increased with constant ratio in low field, but changes with exponential function in high field. The tunnel current of pre-breakdown region is shifted toward low field as much as thermal excitation energy.

Radiation Effects on the Power MOSFET for Space Applications

  • Lho, Young-Hwan;Kim, Ki-Yup
    • ETRI Journal
    • /
    • 제27권4호
    • /
    • pp.449-452
    • /
    • 2005
  • The electrical characteristics of solid state devices such as the bipolar junction transistor (BJT), metal-oxide semiconductor field-effect transistor (MOSFET), and other active devices are altered by impinging photon radiation and temperature in the space environment. In this paper, the threshold voltage, the breakdown voltage, and the on-resistance for two kinds of MOSFETs (200 V and 100 V of $V_{DSS}$) are tested for ${\gamma}-irradiation$ and compared with the electrical specifications under the pre- and post-irradiation low dose rates of 4.97 and 9.55 rad/s as well as at a maximum total dose of 30 krad. In our experiment, the ${\gamma}-radiation$ facility using a low dose, available at Korea Atomic Energy Research Institute (KAERI), has been applied on two commercially available International Rectifier (IR) products, IRFP250 and IRF540.

  • PDF

Pre-sleep casein protein ingestion: new paradigm in post-exercise recovery nutrition

  • Kim, Jooyoung
    • 운동영양학회지
    • /
    • 제24권2호
    • /
    • pp.6-10
    • /
    • 2020
  • [Purpose] Milk is a commonly ingested post-exercise recovery protein source. Casein protein, found in milk, is characterized by its slow digestion and absorption. Recently, several studies have been conducted with a focus on how pre-sleep casein protein intake could affect post-exercise recovery but our knowledge of the subject remains limited. This review aimed at presenting and discussing how pre-sleep casein protein ingestion affects post-exercise recovery and the details of its potential effector mechanisms. [Methods] We systematically reviewed the topics of 1) casein nutritional characteristics, 2) pre-sleep casein protein effects on post-exercise recovery, and 3) potential effector mechanisms of pre-sleep casein protein on post-exercise recovery, based on the currently available published studies on pre-sleep casein protein ingestion. [Results] Studies have shown that pre-sleep casein protein ingestion (timing: 30 minutes before sleep, amount of casein protein ingested: 40-48 g) could help post-exercise recovery and positively affect acute protein metabolism and exercise performance. In addition, studies have suggested that repeated pre-sleep casein protein ingestion for post-exercise recovery over a long period might also result in chronic effects that optimize intramuscular physiological adaptation (muscle strength and muscle hypertrophy). The potential mechanisms of pre-sleep casein protein ingestion that contribute to these effects include the following: 1) significantly increasing plasma amino acid availability during sleep, thereby increasing protein synthesis, inhibiting protein breakdown, and achieving a positive protein balance; and 2) weakening exercise-induced muscle damage or inflammatory responses, causing reduced muscle soreness. Future studies should focus on completely elucidating these potential mechanisms. [Conclusion] In conclusion, post-exercise ingestion of at least 40 g of casein protein, approximately 30 minutes before sleep and after a bout of resistance exercise in the evening, might be an effective nutritional intervention to facilitate muscle recovery.

SF6/CO2혼합기체 중에서 뇌임펄스코로나방전의 특성 (Characteristics of lightning Impulse Corona Discharges in SF6/CO2 Mixtures)

  • 이복희;백영환;오성균;안창환
    • 조명전기설비학회논문지
    • /
    • 제20권1호
    • /
    • pp.85-90
    • /
    • 2006
  • 본 논문은 불평등 전계의 $SF_6/CO_2$혼합기체 중에서 전구방전특성에 대한 실험결과를 제시한다. 임펄스 전구방전 진전을 코로나 전류와 방전광 이미지의 측정으로 조사하였다. 정 부극성의 전구방전 진전메커니즘은 기본적으로 같았으며, 초기스트리머코로나는 침전극의 끝단에서 발단되어 계단상으로 진전하는 리더에 의해 시험갭을 교락시킨다. 정극성에서 리더펄스의 휴지시간은 부극성에서보다 매우 짧았다. 또한 부극성에서 초기스트리머코로나와 절연파괴사이의 시간간격은 정극성에서보다 매우 길게 나타났다. 정극성에서 방전채널경로는 임의적으로 나타났으며, 부극성에서 리더 채널은 정극성에서 보다 굵고 밝게 나타났다.

구리 시료의 정량분석을 위한 LIBS의 최적조건 연구 (Investigation of the optimum condition for the quantitative analysis of Cu sample by Laser induced breakdown spectroscopy)

  • 김승현;신희성;주준식;김호동
    • 분석과학
    • /
    • 제22권2호
    • /
    • pp.141-147
    • /
    • 2009
  • Laser induced breakdown spectroscopy (LIBS)의 정량분석에 대한 측정의 정확도를 향상시키고자, 플라즈마의 특성을 분석하여, 상대적으로 안정적인 Outer sphere에 해당하는 영역을 측정하는 방법으로 Cu alloy sample을 측정하여 분석하였다. 신호의 높은 재현성을 고려한 측정 조건에서 측정이 수행되었으며, 600 mtorr 진공상태에서 20 mm정도의 크기로 플라즈마를 성장시켜, Outer sphere 영역인 플라즈마 성장방향으로 6.0 mm 지점을 측정하였다. 그 결과 Cu의 선형 분석 $R^2$ 값은 0.9886로, Ni의 $R^2$ 값은 0.9988로 획득하였으며, 측정오차는 Ni의 경우 기존보다는 향상된 0.78%의 측정오차를 획득하였다.

Structure of Oxide Film Prepared by Two-step Anodization of Aluminum

  • Ko, Eunseong;Ryu, Jaemin;Kang, Jinwook;Tak, Yongsug
    • Corrosion Science and Technology
    • /
    • 제5권4호
    • /
    • pp.137-140
    • /
    • 2006
  • The effect of pre-existing barrier-type film on porous aluminum oxide film formation during anodization was investigated to control the uniform film growth rate. Initial potential fluctuations during anodization indicated that the breakdown of barrier-film is preceded before the porous formation and the induction time for the porous film growth increases with the increases of pre-existing film thickness. The porous film growth mechanism is lot affected by the presence of barrier film on aluminum surface. In parallel, uniform growth of barrier film underneath the porous structure was attained by two-step anodization processes.

Three-phase Making Test Method for Common Type Circuit Breaker

  • Ryu, Jung-Hyeon;Choi, Ike-Sun;Kim, Kern-Joong
    • Journal of Electrical Engineering and Technology
    • /
    • 제7권5호
    • /
    • pp.778-783
    • /
    • 2012
  • The synthetic short-circuit making test to adequately stress the circuit breaker has been specified as the mandatory test duty in the IEC 62271-100. The purpose of this test is to give the maximum pre-arcing energy during making operation. And this requires the making operation with symmetrical short-circuit current that is established when the breakdown between contact gap occurs near the crest of the applied voltage. Also, if the interrupting chamber of circuit breakers is designed as the type of common enclosure or the operation is made by the gang operated mechanism that three-phase contacts are operated by one common mechanism, three-phase synthetic making test is basically required. Therefore, several testing laboratories have developed and proposed their own test circuits to properly evaluate the breaker performance. With these technical backgrounds, we have developed the new alternative three-phase making circuit.