• Title/Summary/Keyword: Pps

Search Result 399, Processing Time 0.047 seconds

A sample survey design for service satisfaction evaluation of regional education offices (지역교육청 수요자 만족도조사를 위한 표본설계에 관한 연구)

  • Heo, Sun-Yeong;Chang, Duk-Joon
    • Journal of the Korean Data and Information Science Society
    • /
    • v.21 no.4
    • /
    • pp.669-679
    • /
    • 2010
  • A sample survey design is suggested for the service satisfaction evaluation of regional education offices based on the sample size of 2009 Gyeongnam regional education offices's customer satisfaction survey. The sample design is developed to fit the goal of evaluation of individual regional offices and allocate at least the minimum sample size to each city or county in Gyeongnam to achieve the goal of the survey. The population is stratified according to the regions and the types of schools, and the sample of schools is selected with proportional to the size of classes within each stratum. Finally, each sample student is selected according to two-stage cluster sampling within each sample school. Weighting averages, weighting totals and so on can be evaluated for analysis purposes. Their variance estimates can be evaluated using re-sampling methods like BBR, Jackknife, linearization-substitution methods, which are generally used for the data from a complex sample.

Development of TDMA-Based Protocol for Safety Networks in Nuclear Power Plants (원전 안전통신망을 위한 TDMA 기반의 프로토콜 개발)

  • Kim, Dong-Hoon;Park, Sung-Woo;Kim, Jung-Hun
    • The Transactions of the Korean Institute of Electrical Engineers D
    • /
    • v.55 no.7
    • /
    • pp.303-312
    • /
    • 2006
  • This paper proposes the architecture and protocol of a data communication network for the safety system in nuclear power plants. First, we establish four design criteria with respect to determinability, reliability, separation and isolation, and verification/validation. Next we construct the architecture of the safety network for the following systems: PPS (Plant Protection System), ESF-CCS (Engineered Safety Features-Component Control System) and CPCS (Core Protection Calculator System). The safety network consists of 12 sub-networks and takes the form of a hierarchical star. Among 163 communication nodes are about 1600 origin-destination (OD) pairs created on their traffic demands. The OD pairs are allowed to exchange data only during the pre-assigned time slots. Finally, the communication protocol is designed in consideration of design factors for the safety network. The design factors include a network topology of star, fiber-optic transmission media, synchronous data transfer mode, point-to-point link configuration, and a periodic transmission schedule etc. The resulting protocol is the modification of IEEE 802.15.4 (LR-WPAN) MAC combined with IEEE 802.3 (Fast Ethernet) PHY. The MAC layer of IEEE 802.15.4 is simplified by eliminating some unnecessary (unctions. Most importantly, the optional TDMA-like scheme called the guaranteed time slot (GTS) is changed to be mandatory to guarantee the periodic data transfer. The proposed protocol is formally specified using the SDL. By performing simulations and validations using Telelogic Tau SDL Suite, we find that the proposed safety protocol fits well with the characteristics and the requirements of the safety system in nuclear power plants.

Electrical Stimulation Induces the Collagen Deposition and TGF-${\beta}$1 mRNA Expression in Skin Wound of Rat

  • Lee, Jae-Hyoung;Park, Chan-Eui;Park, Rae-Joon
    • The Journal of Korean Physical Therapy
    • /
    • v.22 no.3
    • /
    • pp.87-92
    • /
    • 2010
  • Purpose: The purpose of this study was to investigate the effect of electrical stimulation (ES) on the wound closure rate, collagen deposition, and TGF-${\beta}$1 mRNA expression in skin wound of rat. Methods: Twenty male Sprague-Dawley rats (222~271 g) were randomly divided into ES (n=10) and control group (n=10). The ES group received a cathodal stimulation with 50 V at 100 pps for 30 minutes for 7 days, while the control group was not given electrical stimulation. The wound closure rate, collagen density and TGF-${\beta}$1 mRNA ratio were measured. Results: The mean wound closure rates in the ES and control groups were $83.79{\pm}16.35$% and $51.57{\pm}17.76$%, respectively (p<0.001). The collagen density in the ES and control groups were $46.67{\pm}10.68$% and $25.03{\pm}13.09$%, respectively (p<0.001). The TGF-${\beta}$1 mRNA ratio in the ES and control groups were $1.35{\pm}0.60$ and $0.63{\pm}0.30$, respectively at 6 hours post-wound (p<0.01) and $1.69{\pm}0.47$ and $1.32{\pm}0.28$, respectively, at 7 days post-wound (p<0.05). Conclusions: ES accelerated the wound closure rate of skin incision wounds and was accompanied by an increase in collagen deposition in the regenerating dermis. In addition, ES increased TGF-${\beta}$1 mRNA expression during wound healing process. These findings suggest that ES may activate TGF-${\beta}$1 expression, and may increase synthesis activities of fibroblasts in regenerating skin wounds in rats.

Synthesis and Characterizations of Polyacrylic Superabsorbent Polymer Containing Sorbitol (Sorbitol이 결합된 아크릴계 고흡수성 수지의 합성 및 특성)

  • Kim, Kong-Soo;Shin, Jae-Sup;Moon, Yong-Un;Lee, Kwang-Yong
    • Applied Chemistry for Engineering
    • /
    • v.7 no.1
    • /
    • pp.136-144
    • /
    • 1996
  • Polyacrylic super absorbent polymer(SAP) containing sorbitol was synthesized by inverse-suspension polymerization method. Sodium acrylate and acrylic acid were used as a monomer, ethylene glycol dimethacrylate(EGDMA) and glycerol polyglycidyl ether(GPGE) were used as a crosslinking agent, potassium persulfate(PPS) was used as an initiator, and cyclohexane was used as a solvent. Content of sorbitol was from 10mol% to 50mol% according to the mol ratio of acrylic acid monomer. The size distribution of the round shaped polymeric particle was $177{\sim}707{\mu}m$. Absorption amount of the polymer containing sorbitol was 785 to 1086 times of the polymer weight in distilled water, was 50 to 83 times in 0.9 % NaCl solution. Absorption and retention amount of the polymer were decreased with increasing the amount of sorbitol, but the polymer has an endothermic property which is +5 cal/g SAP.

  • PDF

Iterative Pre-Whitening Projection Statistics for Improving Multi-Target Detection Performance in Non-Homogeneous Clutter (불균일 클러터 환경에서 다중 표적탐지 성능 향상을 위한 반복 백색화 투영 통계 기법)

  • Park, Hyuck;Kang, Jin-Whan;Kim, Sang-Hyo
    • Journal of the Institute of Electronics Engineers of Korea SP
    • /
    • v.49 no.4
    • /
    • pp.120-128
    • /
    • 2012
  • In this paper, we propose a modified iterative pre-whitening projection statistics (MIPPS) scheme for improving multi-target detection performance in non-homogeneous clutter environments. As a non-homogeneity detection (NHD) technique of space-time adaptive processing algorithm for airborne radar, the MIPPS scheme improves the average detection probability of weak target when multiple targets with different reflection signal intensities are located in close range. Numerical results show that the conventional NHD schemes suffers from the masking effect by strong targets and clutters and the proposed MIPPS scheme outperforms the conventional schemes with respect to the average detection probability of the weak target at low signal-to-clutter ratio.

Implementation of AIS Transponder with a New Time Synchronization Method (새로운 시각 동기 방안을 적용한 자동 식별 장치의 구현)

  • 이상정;최일흥;오상헌;윤상준;박찬식;황동환
    • Journal of the Institute of Electronics Engineers of Korea TC
    • /
    • v.40 no.7
    • /
    • pp.273-281
    • /
    • 2003
  • This paper proposes a new time synchronization scheme for the Automatic Identification System(AIS). The proposed scheme utilizes a Temperature Compensated Crystal Oscillator(TCXO) as a local reference clock, and consists of a Digitally Controlled Oscillator(DCO), a divider, a phase comparator, and register blocks. Primary time reference is IPPS from GPS receiver that is synchronized to Universal Time Coordinated(UTC). And if GPS is unavailable, other station's signal is utilized as secondary time reference. The phase comparator measures time difference between the 1PPS and the generated transmit clock. The measured time difference is compensated by controlling the DCO and the transmit clock is synchronized to the Universal Time Coordinated(UTC). The synchronized transmit clock(9600Hz) is divided into the transmitting time slot(37.5Hz). The proposed scheme is tested in an experimental AIS transponder set. The experimental result shows that the proposed module satisfies the timing specification of the AIS technical standard, ITU-R M.1371-1.

An Evaluation of the Home Care Nursing Services Conducted jointly by Catholic Churches and Hospital (일부 가톨릭교회와 연계된 병원중심 가정간호사업의 평가)

  • Kim, Hye-Dan;Kim, Soon-Lae
    • Journal of Korean Academic Society of Home Health Care Nursing
    • /
    • v.12 no.1
    • /
    • pp.41-69
    • /
    • 2005
  • Purpose: This study was performed to evaluate the outcomes of the home care nursing program conducted jointly by thirty two catholic churches and C hospital in Seoul. Method: The subjects included 173 patients who registered for the program during a 4 month-period from November 1, 2004 to February 28, 2005 and received home care services for more than 4 times and 32 professional nurses participating in the program. Using the concept of medical outcome study (MOS), the structure, process, outcome elements were analyzed. Result: 1) A Catholic homecare nursing center and nurses of the C hospital played a central role in providing nursing care, and each church operated its own vehicle from its own office. Home care nurse's job satisfaction was 2.8 out of total score of 4. The major illness was cerebrovascular disease including stroke followed by skeletomuscular disease including degenerative arthritis cancer, and diabetes. Among reasons for accessing the home care nursing program, hypertension management was most prevalent. More than half of the registration was done through catholic churches. Most people who referred the patient to the program was through the church. Most patients received home care nursing 1-2 times a week for 30 to 60 minutes in average and the most frequent type of service provided was basic nursing. 3) The most frequent reason for terminating home care services was death. The change in PPS(Palliative Performance Scale) level from the time of registration and after 4 visits was the same in 45%, decreased in 30%, and improved in 25%. Patient satisfaction was very high, showing 3.4 out of total score of 4. Conclusion: These results proved that the home care nursing program was highly appreciated by subjects and nurses were providing professional care. Thus the two parties involved in the program were actively supporting the program to fulfill their mission. However, several areas needed to be improved such as relating with local community, relating with family doctor, and issue of improving the working conditions for home care nurses.

  • PDF

Wound Healing After Gingivectomy Using Pulsed Nd : YAG Laser In The Rat (백서에서 Pulsed Nd : YAG Laser에 의한 치은절제술후의 치유양상)

  • Kim, Ok-Su;Chung, Hyun-Ju
    • Journal of Periodontal and Implant Science
    • /
    • v.26 no.1
    • /
    • pp.293-308
    • /
    • 1996
  • Recently, dental laser have been applied for removal of soft tissues, hemostasis and blood coagulation, removal of benign and malignant tumor, treatment of leukoplakia, aphthous ulcer and herpetic lesion, implant second surgery, removal of granulation tissue, frenectomy, clinical crown lengthening, gingivectomy, gingivoplasty, and treatment of dentin hypersensitivity. Even though the frequency of laser treatment is increasing, the research on the healing process after gingivectomy using pulsed Nd : YAG laser is very rare. The purpose of this study was to observe and compare the wound healing after gingivectomy using scalpel and pulsed Nd : YAG laser in the rat. Gingivectomy was performed using pulsed Nd : YAG laser(SUNRISE Technologies, U.S.A., 1.5 Watts, 10 pps) on the buccal gingiva of right maxillary first molar and using scalpel(No.12) on the contralateral side. Those sites treated by surgical scalpel were designated as the control, and by pulsed Nd : YAG laser as the experimental group. Animals were sacrificed at 1, 2, 3, 5, 7, 11 and 14 days postoperatively, and specimens were histologically observed under light microscope. The results were as follows : 1. Clinical observation Normal color and shape were observed at the 5th day ill the control group and the 7th day in the experimental group. 2. Histologic findings 1) In the control group, denser inflammatory infiltration was observed. 2) Epithelialization started at the 2nd day in the control group, similar to the experimental group, and completed at the 11th to the 14th day postoperatively. 3) In the experimental group, connective tissue showed the vacuole formation and degenerative change during early healing period. Healing of connective tissue was slower in the experimental group than in the control group by 2 days. 4) In the both groups, wound healing was completed at the 2nd week. From this study, gingivectomy using pulsed Nd : YAG laser seems to result in a little delayed wound healing process, compared to the gingivectomy using scalpel. Considering the clinical advantages of laser surgery, pulsed Nd : YAG laser might be useful device for gingivectomy.

  • PDF

Synchronized sensing for wireless monitoring of large structures

  • Kim, Robin E.;Li, Jian;Spencer, Billie F. Jr;Nagayama, Tomonori;Mechitov, Kirill A.
    • Smart Structures and Systems
    • /
    • v.18 no.5
    • /
    • pp.885-909
    • /
    • 2016
  • Advances in low-cost wireless sensing have made instrumentation of large civil infrastructure systems with dense arrays of wireless sensors possible. A critical issue with regard to effective use of the information harvested from these sensors is synchronized sensing. Although a number of synchronization methods have been developed, most provide only clock synchronization. Synchronized sensing requires not only clock synchronization among wireless nodes, but also synchronization of the data. Existing synchronization protocols are generally limited to networks of modest size in which all sensor nodes are within a limited distance from a central base station. The scale of civil infrastructure is often too large to be covered by a single wireless sensor network. Multiple independent networks have been installed, and post-facto synchronization schemes have been developed and applied with some success. In this paper, we present a new approach to achieving synchronized sensing among multiple networks using the Pulse-Per-Second signals from low-cost GPS receivers. The method is implemented and verified on the Imote2 sensor platform using TinyOS to achieve $50{\mu}s$ synchronization accuracy of the measured data for multiple networks. These results demonstrate that the proposed approach is highly-scalable, realizing precise synchronized sensing that is necessary for effective structural health monitoring.

Photosynthetic Characteristics of Sedum takevimense on Various Moisture Conditions in a Green Roof System (옥상녹화시스템에서 수분 조건에 따른 섬기린초의 광합성 특성)

  • Li, Hong;Kang, Tai-Ho
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.41 no.6
    • /
    • pp.140-146
    • /
    • 2013
  • This experiment was conducted in order to study the physiological characteristics of Sedum takevimense in different moisture conditions. The photosynthetic rate, water use efficiency and the respiratory rate were determined by using a photable photosynthesis system. According to the results, the best illumination range and moisture range were explicitly selected. The highest photosynthetic rate was at $600{\mu}mol{\cdot}m^{-2}{\cdot}s^{-1}$, and after this value, the trend showed a reduction. When the moisture was 11.31%, the photosynthetic capacity and water use efficiency reached maximum value, but the respiratory rate reached maximum value at 7.91%. According to the measured values, the best illumination range was $600{\sim}1,200{\mu}mol{\cdot}m^{-2}{\cdot}s^{-1}$ and the best moisture range was 7.09~11.31%.