• 제목/요약/키워드: Pps

Search Result 399, Processing Time 0.027 seconds

Electrochemical Etch-Stop Suitable for MEMS Applications

  • Chung, Gwiy-Sang;Kim, Sun-Chunl;Kim, Tae-Song
    • Transactions on Electrical and Electronic Materials
    • /
    • v.2 no.2
    • /
    • pp.26-31
    • /
    • 2001
  • This paper presents the electrochemical etch-stop characteristics of single-crystal Si(001) wafers in tetramethyl ammonium hydroxide(TMAH):isopropyl alcohol(IPA):pyrazine solutions. The addition of pyrazine to TMAH:IPA solutions increased the etch rate of (100) Si, thus the etching time required by the etch-stop process shortened. The current-voltage(I-V) characteristics of n- and p-type Si in TMAH:IPA:pyrazine solutions were obtained, respectively. Open circuit potential(OCP) and passivation potential(PP) of n- and p-type Si, respectively, were obtained and applied potential was selected between n- and p-type Si PPs. The electrochemical etch-stop method was used to fabricate 801 microdiaphragms of 20 ${\mu}{\textrm}{m}$ thickness on a 5-inch Si wafer. The average thickness of fabricated 801 microdiaphragms on one Si wafer was 20.03 ${\mu}{\textrm}{m}$ and the standard deviation was $\pm$0.26 ${\mu}{\textrm}{m}$. The Si surface of the etch-stopped microdiaphragm was extremely flat with no noticeable taper or nonuniformity.

  • PDF

Effect of Conventional Transcutaneous Electrical Nerve Stimulation on Plasma $\beta-endorphin$ Level (고빈도-저강도 경피신경전기자극이 혈장 $\beta-endorphin$ 농도에 미치는 영향)

  • Lee Jae-Hyoung;Pack Chun-Seo;Kang Jung-Koo
    • The Journal of Korean Physical Therapy
    • /
    • v.5 no.1
    • /
    • pp.39-46
    • /
    • 1993
  • The purpose of this study was to examine the effect and $\beta-endorphin$ level as conventional transcutaneous electrical nerve stimulation (TENS) application on acupuncture paints. Twelve healthy adult male volunteers were participated in this study. The subjects were assigned to TENS group (n=6) and naloxone group (n=6). The LI 3 and M 10 meridian points of dominant arm were stimulated comfortably with 100 pps, $75{\mu}s$ conventional TENS for 30 minutes. Experimental pain threshold measurement and plasma $\beta-endorphin$ level were detected before and after conventional TENS application. Experimental pain threshold increased significantly (p<.01) but plasma $\beta-endorphin$ level was not change in TENS group. Experimental pain threshold increased significantly (p<.01) but plasma $\beta-endorphin$ level was not change in naloxone group. In this study, the conventional TENS induced analgesic effect, and plama $\beta-endorphin$ level was not increase concomitantly with analgesia. These results suggest that the $\beta-endorphin$ did not involved in conventional TENS analgesia.

  • PDF

The Effect of Acrylic Emulsion on Coated Paper Properties (아크릴 에멀젼이 도공지 물성에 미치는 영향)

  • Kim, Sun-Kyung;Park, Yong-Chul;Jung, Hae-Sung;Lee, Yong-Kyu
    • Journal of Korea Technical Association of The Pulp and Paper Industry
    • /
    • v.44 no.1
    • /
    • pp.37-42
    • /
    • 2012
  • This study was carried in order to manufacture the high quality coated paper. High quality includes not only physical and optical properties of coated paper but also final print quality. In this study, new acrylic-styrene emulsion was polymerized in laboratory and compared with conventional styrene-butadiene latex. Low-shear viscosity of coating color was decreased with increasing acrylic-emulsion dosage. Small amount of acrylic emulsion addition increased water retention, but further addition decreased it. Acrylic-emulsion addition improved paper gloss, brightness and whiteness, but decreased PPS and opacity slightly. Ink gloss was increased with using No. 3 acrylic-emulsion due to lower ink setting properties. However No. 1 and 2 emulsion showed the opposite result. Surface strength of coated paper was increased with using No. 3 acrylic-emulsion. These results indicate that high quality coated paper can be manufactured with using No. 3 acrylic-emulsion.

High Voltage Nano-Pulse Generator for Industrial Waste Water Treatment (폐수 처리용 고전압 나노 펄스 발생기)

  • Jang, Sung-Duck;Son, Yoon-Gyu;Oh, Jong-Seok;Kwon, O-Jung
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.4 no.3
    • /
    • pp.311-318
    • /
    • 2001
  • The application of a pulsed power system is being extended to a environmental and industrial fields. The non-dissolution waste water pollutants from industrial plants can be processed by applying high voltage pulses with a fast rising time (a few nanoseconds) and short duration (nano to microseconds) in a pulsed corona discharge reactor. The nano-pulse generator with a magnetic switch has been developed. Its corona current in load can be adjusted by pulse width and repetition rate. we investigated the performance of the nano-pulse generator using the dummy load which is composed of resistor and capacitor equivalent to the actual reactor. This paper descibes the electrical characteristics of the nano-pulse generator that produces a 300 ns pulse at maximum repetition rate of 400 pps with a voltage of 40 kV across a $640{\Omega}$ load. In this paper we briefly discuss a configuration of system and test results.

  • PDF

THE ALTERATION OF OXIDATIVE DAMAGE AND ACTMTIES OF METABOLIZING ENZYMES IN RATS TREATED WITH PEROXISOME PROLIFERATORS

  • Sea, Kyung-Won;Kim, Kyu-Bong;Kim, Yun-Jung;Suh, Soo-Kyung;Kim, Jong--Min;Park, Chang-Won;Kim, Jong-Won;Kim, Kwang-Jin;Choi, Ju-Young;Kim, Joo-Il;Lee, Kyung-Tae;Lee, Sun-Hee
    • Proceedings of the Korean Society of Toxicology Conference
    • /
    • 2001.10a
    • /
    • pp.116-117
    • /
    • 2001
  • The phthalates have been shown to produce hepatic peroxisome proliferation and certain peroxisome proliferators (PPs) are also known to increase the incidence of liver tumors in rodents. In this study we investigated the correlation between oxidative injury, changes in peroxisomal and microsomal enzymes and tumor formation in PP-treated rats.(omitted)

  • PDF

The Optimization of Output Characteristics with High Repetition Rate Pulsed $CO_2$ Laser Using SMPS (SMPS 방식의 고반복 펄스형 $CO_2$레이저의 출력특성 최적화)

  • Lee, D.H.;Chung, H.J.;Kim, D.W.;Kim, W.Y.;Kim, H.J.;Cho, J.S.
    • Proceedings of the KIEE Conference
    • /
    • 1999.07e
    • /
    • pp.2192-2194
    • /
    • 1999
  • In this study, We have accomplished a new approach to develope a cheap and compact pulsed $CO_2$ laser system. We used a fast SCR as switching device instead of a thyatron in the pulsed power supply. Using the Pulse transformer, energy in the condenser is tranferred to the secondary, electrodes of discharge tube, from the primary. An axial and water cooled type was adopted as the laser cavity. The laser performance characteristics as various parameters, such as gas pressure and pulse repetition rate, have been investigated. As a result, the maxium laser output was 12.3[W] at a pulse repetition rate of 120[pps] and a filling pressure of 12[Torr].

  • PDF

A Study on the Weldability of Magnesium Alloy by Laser Heat Source (III) - Butt Weldability of Sand Casting Magnesium Alloy using Pulsed Nd:YAG Laser - (레이저 열원을 이용한 마그네슘 합금의 용접성에 관한 연구 (III) - Pulsed Nd:YAG 레이저를 이용한 사형주조 마그네슘 합금의 맞대기 용접성 -)

  • Kim, Jong-Do;Lee, Jung-Han;Lee, Mun-Yong
    • Journal of Welding and Joining
    • /
    • v.31 no.2
    • /
    • pp.57-62
    • /
    • 2013
  • Magnesium has good castability and limited workability, so its products have been manufactured by almost casting processes. In this study, a pulsed Nd:YAG laser was used to butt-weld the sand casting magnesium alloys. And the effect of welding conditions such as peak power, pulse width, welding speed was evaluated in detail. As a result of this study, large underfill and plenty of spatter taken place under the conditions with high peak power. Thus, it is recommended to use low peak power and long pulse width to obtain good welds with deep penetration. It is also confirmed that the welding speed and pps(pulse per second) are directly connected at weld defects such as underfill, porosity.

Operation Characteristic and Harmonic Analysis of 200-MW Modulator (200-MW 모듈레이터의 동작 특성 및 고조파 해석)

  • Park, S.S.;Oh, J.S.;Cho, M.H.;NamKumg, W.
    • Proceedings of the KIEE Conference
    • /
    • 1994.07b
    • /
    • pp.1577-1579
    • /
    • 1994
  • 200-MW pulse modulators(total 11units) for the PLS linac employ the SCR phase control circuit. It controls 3-phase AC line voltage for the high-voltage DC power supply (DCPS, maximum of 25kVDC, 4.2A) which charges the pulse forming network(PFN). The PFN delivers 400kV, 500A, ESW $7.5{\mu}s$ pulse power to the 80-MW klystron amplifier tube. The SCR regulates 3-phase AC power and feeds to the high voltage transformer. Two different types of the transformer configurations namely ${\Delta}-{\Delta}$ and ${\Delta}-Y$, are alternatively installed to 11 modulator units for the suppression of harmonic noises. RC filters and reactors are also installed. Currently, approximately 110-kW of average AC power per unit is consumed at the normal operation level of the modulator with 30pps. This paper presents the operational characteristics of the high power pulse modulator, especially the experimental results of the AC line harmonic components generated by the operation of the high power pulse modulator to suppress the switching noises from the SCR and rectifying diode arrays.

  • PDF

DESIGN AND TEST RESULTS ON A 45-KV PULSED POWER MODULATOR FOR A 1.5-MW MAGNETRON APPLICATION OF KSTAR LHCD

  • Jang, Sung-Duck;Son, Yoon-Gyu;Oh, Jong-Seok;Bae, Young-Soon;Cho, Moo-Hyun;NamKung, Won
    • Nuclear Engineering and Technology
    • /
    • v.38 no.8
    • /
    • pp.785-792
    • /
    • 2006
  • The microwave heating system of KSTAR consists of ECH and LHCD. ECH and LHCD offer the benefits ofa reliable operation at the start of plasma formation and a non-inductive current drive durable steady state operation, respectively. LHCD uses a C-band microwave system with a frequency of 5 GHz. A pulsed power modulator with a power of 3.6 MW, $4{\mu}S$, 200 pps is required to drive the high-powered magnetron. The development of a pulse modulator with 1:4 pulse transformers is the focus of the research in this study. The peak power handling capability is 3.6 MW (45 kV, 90 A at load side with a pulse width of $4{\mu}S$). This paper describes the system overview and test results of the pulsed modulator. In particular, a simulated waveform is compared with the tested waveform.

Experiments for utilizing GNSS in a shore area Sensor Network

  • Hojo, Harumasa;Yasuda, Akio;Fan, Chunming;Yoshida, Masashi;Koike, Yoshikazu;Minami, Masateru
    • Proceedings of the Korean Institute of Navigation and Port Research Conference
    • /
    • v.2
    • /
    • pp.117-122
    • /
    • 2006
  • Modernized GNSS such as new GPS signals updated GLONASS and coming Galileo promises higher quality and higher reliability for users. Powerful technologies such as Internet, ubiquitous network technology and sensor network has been used to promote a safe and more secure lifestyle. This report describes experimental trials to combine these technologies namely GPS and Sensor Network into a high-performance system. GPS is used to enlarge the communication range, resolving the service area limitations, as a wider service area is required at shore areas compared to urban area. GPS position datum is also used as primary network routing information to get practical Sensor Network. Another application is the under water Sensor Network. Accurate GPS position and time are used to establish stable and high reliability underwater acoustic Sensor Network. This paper describes the background of the project 'Harbor area Marine Ubiquitous Sensor Network', preliminary consideration and testing. Radio and acoustic communication is the main focus of this preliminary experiment.

  • PDF