• Title/Summary/Keyword: Powerline Communication

Search Result 72, Processing Time 0.038 seconds

A Simulation Technique for the Characterization of the Low-bit-rate Household AC Power Line Communication Channel (저 비트율 전력선 모뎀에 대한 저압 댁내망의 채널 특성 시뮬레이션 기법에 관한 연구)

  • An, Nam-Ho;Jeong, Tae-Gyu
    • The Transactions of the Korean Institute of Electrical Engineers D
    • /
    • v.51 no.5
    • /
    • pp.197-202
    • /
    • 2002
  • In this paper, the characteristics of the household AC power line network is analyzed for the low bit rate powerline communication (PLC) in the frequency range from 10㎑ to 450㎑ The PLC channel transfer characteristics including its characteristic impedance are derived based on the network topology which is constructed with the household power lines loaded with the various types of electric apparatus. Both the distributed circuit analysis and the lumped circuit model based analysis are applied for the characterization of the PLC channel and the results are compared by the computer simulations. The analysis illustrates very well the adverse effects caused by the loading of electric apparatus and as well those casued by the reflection of wavers in the household AC Power line communication network.

A Study on Application of Inductive PLC to Electric Charging System (유도형 전력선 통신의 전기충전시스템 적용 연구)

  • Sohn, Kyung-Rak;Jeong, Jae-Hwan;Yang, Seung-Ho
    • Proceedings of the Korean Institute of Navigation and Port Research Conference
    • /
    • 2018.05a
    • /
    • pp.153-153
    • /
    • 2018
  • In this paper, we have represented basic experiment results for the application of electric vehicle powerline communication using an induction type coupler. The coupler was fabricated using nano-crystalline alloy and it was applied to the charging system of electric vehicles to measure the communication performance. Experimental results showed a channel bandwidth over 48 Mbps.

  • PDF

A Fire Prevention System of the Nacelle of Wind Turbine Generator System Based on Broadband Powerline Communication (광대역 전력선통신 기반 풍력발전기 너셀 내부 화재예방시스템)

  • Kim, Hyun-Sik;Ju, Woo-Jin;Kang, Seog Geun
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.13 no.6
    • /
    • pp.1229-1234
    • /
    • 2018
  • In this paper, a fire prevention system based on a broadband powerline communication (PLC) system is implemented and a demonstration experiment is carried out to prevent from or promptly dealing with possible fires within the nacelle of a wind turbine generator system (WTGS). For this purpose, an inductive coupler having satisfactory attenuation characteristic in the frequency region for high-speed PLC is also manufactured. It is confirmed that the implemented system can monitor the environmental change inside the nacelle in real time by transmitting various information obtained by the sensors such as temperature, flame, and smoke sensor installed in the nacelle and thermal image recorded by a thermal camera to the ground control center through the PLC system. Therefore, it is, considered that the implemented system will significantly improve the reliability of the fire monitoring and prevention system of the WTGS in conjunction with the existing safety system.

Development of Demand Controller Using Power Line communication (전력선 통신을 이용한 디멘드 콘트롤러의 개발)

  • Kim Ho;Park Hae-Won;Lee Jeong-Bok;Seok Won-Yeop;Jeon Hee-Jong
    • Proceedings of the KIPE Conference
    • /
    • 2001.07a
    • /
    • pp.619-622
    • /
    • 2001
  • In this paper, an intelligent demand control system was introduced. This system is composed of demand controller, RTU, Power Line Modem and HMI program. The developed demand controller was capable of synchronizing with watthour meter recommended by KEPCO. To control distant loads, network function using powerline communication is implemented in RTU, with HMI program, the untrained users are able to operate system easily. Additionally using the Powerline, the cost and time of installation is saved. The system performance was proved In a several experiments.

  • PDF

A Study on Noise Characteristics of Powerline Communication Channel (전력선 통신 채널의 잡음 특성에 관한 연구)

  • Choi, Seung-Ji;Yu, Jung-Hun;Oh, Hui-Myoung;Lee, Jae-Jo;Lee, Won-Tae;Kim, Kwan-Ho
    • Proceedings of the KIEE Conference
    • /
    • 2003.07d
    • /
    • pp.2696-2698
    • /
    • 2003
  • 전력선 통신 채널(powerline communication channel)은 원래 전력을 전송하기 위한 선로로서 무선 채널 및 그 밖의 다른 통신 채널들과 같이 부가적 가우시안 잡음 환경 등의 표준 모델로 잘 표현되지 않는 특성이 있다. 그리고 1MHz-30MHz 대역에서의 전력선 채널의 잡음은 배경잡음, 연속 신호(continuous wave) 협대역 및 광대역 잡음, 그리고 임펄스 잡음으로 분류될 수 있으며, 특히 고속 데이터 전송 시스템에서는 임펄스 잡음에 의한 영향이 큰 것으로 알려져 있다. 본 논문에서는 아파트형 주거지에서 실측한 주파수 영역 및 시간영역의 잡음 데이터를 제시하고, 이러한 데이터를 바탕으로 연속 신호 잡음을 포함한 배경잡음과 임펄스 잡음의 모델 및 통계적 특성을 제시한다.

  • PDF

Development of Low Power PLC Modem for Monitoring of Power Consumption and Breaking of Abnormal Power (전력감시 및 이상전력 차단 기능을 갖는 저전력 전력선통신 모뎀 개발)

  • Yoon, Jae-Shik;Wee, Jung-Chul;Park, Chung-Ha;Song, Yong-Jae;Kim, Jae-Heon
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.58 no.11
    • /
    • pp.2281-2285
    • /
    • 2009
  • Powerline communication is the data signal which is modulated by carrier frequency through the installed powerline at in-home or office is transmitted and received signals are separated into data signal with using band-pass filter which cent-frequency is carrier frequency. The home gateway, an equipment which works as an gateway for ubiquitous home network, relays all functions of a home network. The home gateway must always be connected in order to provide seamless services. However it gives unfavorable power consumption. Therefore the needs for working in maximum power saving mode while there is no data traffic and for invoking to the normal function when it is necessary. So, in this paper we survey the development of low power PLC modem monitoring of power consumption and breaking abnormal power in the home Network.

Power-line Communication based Digital Home-Network Technology (전력선 통신기술기반의 디지털 홈네트워크 기술)

  • Jin, Tae-Seok
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2010.05a
    • /
    • pp.992-995
    • /
    • 2010
  • We propose an Power line communication, also known as Power line Digital Subscriber Line (PDSL), mains communication, power line telecom (PLT), or power line networking (PLN), or Broadband over Power Lines (BPL) are systems for carrying data on a conductor also used for electric power transmission. Power line communications can also be used to interconnect home computers, peripherals or other networked consumer peripherals. Specifications for power line home networking have been developed by a number of different companies within the framework of the HomePlug Powerline Alliance, the Universal Powerline Association and the HD-PLC Alliance.

  • PDF

Application of High-Current PLC of Soft Magnetic Core Type Coupler (연자성체 코어형 결합기의 대전류 전력선통신 적용)

  • Jeong, Jae-Hwan;Yang, Seung-Ho;Soh, Kyung-Rak
    • Proceedings of the Korean Institute of Navigation and Port Research Conference
    • /
    • 2018.05a
    • /
    • pp.155-155
    • /
    • 2018
  • In this study, we measured the communication performance of inductive coupler under high current condition. Ferrite and nanocrystalline cores were used to compare the available PLC communication range and bandwidth for current fluctuations.

  • PDF

Block Media Communication System for Implementation of a Communication Network in Welding Workplaces (용접 작업장 통신네트워크 구축을 위한 블록매체통신시스템)

  • Kim, Hyun Sik;Kang, Seog Geun
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.26 no.4
    • /
    • pp.556-561
    • /
    • 2022
  • In this paper, we present a block media communication (BMC) system which employs powerline communication to the equipments used in the welding process for ship-assembly and uses metal block as a communication medium. Inductive couplers are installed on digital feeder and pin jig. Information signal is added to the current generated by the welding gun, and applied to the block. When the welding operation starts, information generated in the field is transmitted to the monitoring server in real-time. The field test on the BMC system confirms that the transmitted data are correctly received at the server. Since the proposed system can be built without any changes to the existing welding process, it is helpful to increase competitiveness of the shipbuilding industry through smart factory of shipyards. It is also possible to quickly respond to emergency situations that may occur to workers in an electromagnetic wave shielding environment or a closed space, the effect of preventing industrial accidents will be great.

Performance Analysis of the Powerline Communication for Condition Monitoring System of an MW Class Offshore Wind Turbine's Nacelle (MW급 해상풍력발전기 나셀의 상태 감시를 위한 전력선 통신 성능 분석)

  • Sohn, Kyung-Rak;Kim, Kyoung-Hwa;Jeong, Seong-Uk;Nam, Seung-Yun;Kim, Hyun-Sik
    • Journal of Navigation and Port Research
    • /
    • v.40 no.3
    • /
    • pp.159-164
    • /
    • 2016
  • The goal of this study is to implement a communication system that can monitor the status of the nacelle using the power cable itself, without the dedicated communication lines such as an UTP cable and optical fiber for the offshore wind turbine. An inductive coupling powerline communication system for a MW class offshore wind turbine was proposed and its communication performance was demonstrated. The inductive couplers was designed for operation at up to 500 A using a ferrite composite materials. Field test was carried out on the wind farms of Jeju island. Using the iperf communication test program, we have obtained more than 15 Mbps data transmission rate through the 100 m power cable that was installed between the nacelle and the bottom of the power converter. In the data transmission stability test for a week, there was no failure ever. The minimum transmission rate was 15 Mbps and the average data rate was about 20 Mbps. Next, we have installed an infrared camera inside the nacelle in order to measure the temperature distribution and variation of the nacelle. The real-time thermal image taken by the camera was successfully sent to the monitoring system without error.