• 제목/요약/키워드: Power-Saving

Search Result 1,284, Processing Time 0.027 seconds

Comparative Evaluation of Electric Power and LNG Load according to Floor level of Tower-Type Apartments (탑상형 아파트의 층별 전기와 가스 부하량 비교평가)

  • Kim, Jun Hyun;Choi, Jin Ho;Um, Jung-Sup
    • Journal of Environmental Impact Assessment
    • /
    • v.20 no.4
    • /
    • pp.465-475
    • /
    • 2011
  • It is known that energy consumption in bottom floor of typical Korean-style apartment is the highest. Previous studies for energy consumption in accordance with floor level appear to be very limited due to the dependence on single energy variable such as electric power or LNG separately, based on past flat type of apartment. Acknowledging these constraints, an empirical study for a tower type emerged recently as new style of apartment in South Korea was conducted to demonstrate how a comprehensive evaluation for both electric power and LNG consumption can be used to assist in monitoring the total energy consumption in terms of floor specific settings. It was possible to identify that energy consumption in bottom floor is lesser than that of top floor, to the contrary, fact known from previous study. Also electric power consumption in top floor was identified as 15% higher than that of floor in the least. It is anticipated that this integrated utilization of electric power and LNG data would present more scientific and objective evidence for the energy load among floor level of tower type apartment by overcoming serious constraints suffered from the past single variable investigation. Ultimately, the result in this paper could be used as a valuable reference to providing priority for energy saving activities in top floor such as cool roof or green roof.

Effects of Pipe Network Composition and Length on Power Plant Waste Heat Utilization System Performance for Large-scale Horticulture Facilities (발전소 온배수를 적용한 대규모 시설원예단지용 난방시스템의 열원이송 배관 재질 및 거리에 따른 성능평가)

  • Lee, Keum ho;Lee, Jae Ho;Lee, Kwang Ho
    • Journal of the Korean Society for Geothermal and Hydrothermal Energy
    • /
    • v.11 no.4
    • /
    • pp.14-21
    • /
    • 2015
  • Korean government plans to establish large-scale horticulture facility complexes using reclaimed land in order to improve the national competitiveness of agriculture at the government level. One of the most significant problems arising from the establishment of those large-scale horticulture facilities is that these facilities still largely depend on a fossil fuel and they require 24 h a day heating during the winter season in order to provide the necessary breeding conditions for greenhouse crops. These facilities show large energy consumption due to the use of coverings with large heat transmission coefficients such as vinyl and glass during heating in the winter season. This study investigated the applicability of waste heat from power plant for large-scale horticulture facilities by evaluating the waste heat water temperature, heat loss and energy saving performance as a function of distance between power plant and greenhouse. As a result, utilizing power plant waste heat can reduce the energy consumption by around 85% compared to the conventional gas boiler, regardless of the distance between power plant and greenhouse.

Heating Power Consumption Comparison Study Between Static Insulation and Dynamic Insulation at KIER Twin Test Cell (동적 단열재를 적용한 건물에서의 에너지소비량 비교 분석)

  • Kang, Eun-Chul;Park, Yong-Dai;Lee, Euy-Joon;Yun, Tae-Kwon
    • Proceedings of the SAREK Conference
    • /
    • 2008.06a
    • /
    • pp.919-924
    • /
    • 2008
  • Power consumption in the building thermal load could be the sum of the building fabric conduction load, building ventilation convection load and other such as radiation loss load. Dynamic Breathing Building (DBB) is the state-of-the-art to improve the wall insulation and indoor air quality(IAQ) performance as making air flow through the wall. This heat recovery type DBB contributes the power consumption saving due to the improved dynamic U-value. KIER twin test cell with static insulation(SI) and dynamic insulation(DI) at KIER was developed to test building power consumption at the real outside conditions. Then, the actual results were compared with the theory to predict the power consumption at the KIER twin test cell and introduced the building new radiation loss factor $\alpha$ to explain the difference between the both the theory and the actual case. As the results, the power consumption at the breathing DI wall building could saved 10.8% at the 2ACH(Air change per hour) compared with conventional insulation. The building radiation loss factor $\alpha$ for this test condition to calibrate the actual test was 0.55 in the test condition.

  • PDF

A Study on an Evaluation Modeling of Power System Performance for Frequency Regulation ESS Based on the PSCAD/EMTDC (PSCAD/EMTDC를 이용한 주파수조정용 ESS의 계통영향성 평가 모델링에 관한 연구)

  • Choi, Sung-Sik;Kang, Min-Kwan;Lee, Hu-Dong;Nam, Yang-Hyun;Park, Ji-Hyun;Rho, Dae-Seok
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.67 no.8
    • /
    • pp.1024-1030
    • /
    • 2018
  • Recently, the large scaled energy storage system(ESS) which has various functions such as peak saving, demand management, output stabilization of renewable energy and frequency regulation(FR) is being energetically installed and operated. Especially, as the use case of frequency regulation ESS, the KEPCO has demonstrated the total of 376[MW] ESS since 2014. However, there are no operational experiences and international technical standards on frequency regulation application in ESS. Therefore, this paper propose the evaluation algorithm for power system performance of ESS by considering the frequency characteristics between governor of existing generator and frequency regulation ESS, in order to verify the power system performance of ESS. And also, this paper propose an evaluation modeling for small scaled power system including the existing generator, frequency control ESS and customer loads based on the PSCAD/EMTDC S/W. From the simulation results in 360[MW] model power system, it is confirmed that frequency regulation ESS has better performances than conventional generators.

A Study on the Feasibility of Applying Solar Power Generation Systems to Merchant Ships for Energy Saving (에너지 절감을 위한 태양광 발전시스템의 선박 적용 타당성 연구)

  • Kim, Kyunghwan;Jeon, Hyeonmin;Kim, Seongwan
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.27 no.7
    • /
    • pp.1067-1073
    • /
    • 2021
  • Regulations to reduce greenhouse gas emissions from ships are gradually being strengthened. EEXI (Energy Efficiency Existing Index) has been introduced in existing ships, and various studies are aimed at achieving the greenhouse gas emission reduction target are currently underway. In this study, we proposed a method to reduce greenhouse gas emissions through reducing fuel oil consumption by applying a solar power generation system to a pure and truck carrier among existing ships engaged in international voyages. The proposed photovoltaic power generation system consists of a photovoltaic module, an energy storage system, and a power conversion device. To confirm applicability, the system was modeled through a power electronics program, and a simulation was performed. In addition, economic analysis was conducted to check the feasibility of application to real ships, and it was confirmed that significant results were derived in the economical aspect after about 11 years had elapsed.

Research Method of Driving Driver to improve Stability and Reliability of AC LED (AC LED의 안정성과 신뢰성 향상을 위한 구동용 DRIVER 연구방안)

  • Yoon, Yongho
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.20 no.1
    • /
    • pp.205-210
    • /
    • 2020
  • Thanks to the shift in awareness of environmentally friendly energy and government initiatives, practical light-emitting diode(LED) lighting fixtures have emerged and are being distributed, resulting in very large energy savings. However, in actual use of LED lighting, it is possible to use it as an individual, but when using a large street light or a whole home lighting, the whole lighting system is realized due to various problems such as efficiency, stability, and reliability. Doing so has several problems. Although AC-LED has been developed recently to solve safety problems such as heat generation phenomenon of the conventional DC-LED, it also has various problems such as quality safety and reliability, which are difficult to use as outdoor lighting using existing AC Power. This happens. Accordingly, the appropriate power for AC-LED should be developed and applied, and the emergence of such LED lighting will play a role as a tool that can overcome the limitations of existing LED lighting and implement sustainable energy saving.

Study of Electric Charge Saving Plan Using High-speed Charging Wireless Railway System (급속충전방식 무가선 전동차 시스템을 이용한 전기요금 절감 방안 연구)

  • Go, Hyo-Sang;Cho, In-Ho;Ryu, Joon-Hyoung;Kim, Gil-Dong
    • Journal of the Korean Society for Railway
    • /
    • v.20 no.1
    • /
    • pp.31-42
    • /
    • 2017
  • Many studies have been performed to reduce electric consumption in railway systems. Due to its low conduction loss and high regenerative braking efficiency characteristics, the ESS powered railway system is chosen as a promising candidate for future railway systems. This paper introduces the ESS powered railway system and analyzes current power charge calculation methods that have been set up by KEPCO (Korea Electric Power Corporation). Based on the analysis, this paper proposes two different power charge reduction methods for the railway system. One is to smooth the peaks of traction energy consumption by supplying additional energy to the grid. The other is to save electric charge by reducing electric energy consumed by the railway during the energy peak time, 2 p.m.~5 p.m., which has highest 'Won/kWh' rates. To verify the effectiveness of the proposed method, the power charge of Seoul Metro Line 2 is recalculated using the method.

A Inverter Control System for Vertical Circulation Parking Facility (수직순환식 입체주차설비용 인버터 제어시스템)

  • Choi, Chul;Lee, Jin-Ha;Kim, Chul-Woo
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.9 no.3
    • /
    • pp.294-302
    • /
    • 2004
  • In this study, we developed the inverter system to control Induction motor for the vertically circulation parking facility. In the case of calling a pallet, a car parking space, we basically stoned conventional system's problems, pallet is uncontrollable to the fixed position and braking system was worn by forcer braking with remaining speed. Also, by appling to converter controller, added to power regenerative control function, we confirmed the reduce of power supply capacity and the energy saving effect according to increasing operation frequency. The validity of this system is verified by 55kw induction motor driving system. Via this study, the proposed system shows the efficient use of parking facility and good operation characteristics by implementing position and speed control effectively on condition of load and shows energy saying effect by power factor control for the vertically circulation parking facility operation.

An Improvement of the JCVM System Architecture for Large Scale Smart Card having Seamless Power Supply (전원 공급이 지속적인 대용량 스마트 카드를 위한 JCVM 시스템 구조 개선)

  • Lee, Dong-Wook;Hwang, Chul-Joon;Yang, Yoon-Sim;Jung, Min-Soo
    • Journal of Korea Multimedia Society
    • /
    • v.10 no.8
    • /
    • pp.1029-1038
    • /
    • 2007
  • A smart card based on the existing Java card platform executes and installs an application only when the power is supplied for a minute. And preparing for unexpected power outrage, the execution state of an application and all the data that are modified during execution are saved in the heap. This kind of frequent data update of an EEPROM data is a main cause of reducing the life-cycle of a smart card. This is because the smart card has been developed not considering the current situation that the power is always supplied, and by this time it has continuously kept its old architecture. This paper explains the high performance Java card system free power restriction. The system improves not only application saving mechanism, but memory architecture. In special, we deploy RAM for running an applet, as well as EEPROM for downloading an application. Through proposed mechanism, we can find out performance evaluation that the creation speed of an applet and the execution speed of a method increase up to 58% and 33% respectively.

  • PDF

Acoustic Valve Leak Diagnosis and Monitoring System for Power Plant Valves (발전용 밸브누설 음향 진단 및 감시시스템)

  • Lee, Sang-Guk
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2008.04a
    • /
    • pp.425-430
    • /
    • 2008
  • To verify the system performance of portable AE leak diagnosis system which can measure with moving conditions, AE activities such as RMS voltage level, AE signal trend, leak rate degree according to AE database, FFT spectrum were measured during operation on total 11 valves of the secondary system in nuclear power plant. AE activities were recorded and analyzed from various operating conditions including different temperature, type of valve, pressure difference, valve size and fluid. The results of this field study are utilized to select the type of sensors, the frequency band for filtering and thereby to improve the signal-to-noise ratio for diagnosis for diagnosis or monitoring of valves in operation. As the final result of application study above, portable type leak diagnosis system by AE was developed. The outcome of the study can be definitely applied as a means of the diagnosis or monitoring system for energy saving and prevention of accident for power plant valve. The purpose of this study is to verify availability of the acoustic emission in-situ monitoring method to the internal leak and operating conditions of the major valves at nuclear power plants. In this study, acoustic emission tests are performed when the pressurized temperature water and steam flowed through glove valve(main steam dump valve) and check valve(main steam outlet pump check valve) on the normal size of 12 and 18 ". The valve internal leak monitoring system for practical field was designed. The acoustic emission method was applied to the valves at the site, and the background noise was measured for the abnormal plant condition. To improve the reliability, a judgment of leak on the system was used various factors which are AE parameters, trend analysis, frequency analysis, voltage analysis and amplitude analysis of acoustic signal emitted from the valve operating condition internal leak.

  • PDF