• Title/Summary/Keyword: Power-Saving

Search Result 1,284, Processing Time 0.028 seconds

Studies on Synchronization Techniques for Power Saving of DVB-H Terminal (DVB-H 수신기의 전력소모감소를 위한 동기화 기법에 관한 연구)

  • Nam Seungwoo;Sohn Won
    • Journal of Broadcast Engineering
    • /
    • v.10 no.2
    • /
    • pp.174-181
    • /
    • 2005
  • In this paper, we proposed new fast scattered pilot synchronization techniques to reduce the burst synchronization time for the DVB-H receiving system with robustness. DVB-H terminals employ a TDM system called 'Time-Slicing' to reduce power consumption. In order to fully exploit the potential power reduction, the synchronization time for the DVB-H receiver must be very short. A typical DVB-T system uses the TPS Synchronization to determine the position of scattered pilots which are used for channel estimation, and it takes 68 OFDM symbol time. In this paper, several new fast scattered pilot synchronization techniques are proposed.

Development of Variable Duty Cycle Control Method for Air Conditioner using Artificial Neural Networks (신경회로망을 이용한 에어컨의 가변주기제어 방법론 개발)

  • Kim, Hyeong-Jung;Doo, Seog-Bae;Shin, Joong-Rin;Park, Jong-Bae
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.55 no.10
    • /
    • pp.399-409
    • /
    • 2006
  • This paper presents a novel method for satisfying the thermal comfort of indoor environment and reducing the summer peak demand power by minimizing the power consumption for an Air-conditioner within a space. Korea Electric Power Corporation (KEPCO) use the fixed duty cycle control method regardless of the indoor thermal environment. However, this method has disadvantages that energy saving depends on the set-point value of the Air-Conditioner and direct load control (DLC) has no net effects on Air-conditioners if the appliance has a lower operating cycle than the fixed duty cycle. In this paper, the variable duty cycle control method is proposed in order to compensate the weakness of conventional fixed duty cycle control method and improve the satisfaction of residents and the reduction of peak demand. The proposed method estimates the predict mean vote (PMV) at the next step with predicted temperature and humidity using the back propagation neural network model. It is possible to reduce the energy consumption by maintaining the Air-conditioner's OFF state when the PMV lies in the thermal comfort range. To verify the effectiveness of the proposed variable duty cycle control method, the case study is performed using the historical data on Sep. 7th, 2001 acquired at a classroom in Seoul and the obtained results are compared with the fixed duty cycle control method.

A Study on ESS-based Clean Energy, Smart Home IoT Platform (ESS기반 클린에너지, 스마트홈 IoT 플랫폼 연구)

  • Kim, Hee-Chul
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.13 no.1
    • /
    • pp.147-152
    • /
    • 2018
  • This study investigates the demand management and energy saving plan of the apartment house based on the ESS (: Energy Storage System), which is the main equipment in the field of electric power energy efficiency, and suggests standardization for various technical factors and operation. It contributes to the spread of ESS industry. In addition, to create ESS market for apartment houses and smart homes, housing IoT technology is used to integrate apartment houses with smart home-based ESS and it is possible to achieve use efficiency and economic feasibility of power users, We will study a business model that can reconsider the acceptability of power users.

Development of Holder Ampere Control Arc Welding System and It′s Usefulness (홀더 암페어 조절 아크용접 시스템 개발 및 그 유용성)

  • 이용복
    • Proceedings of the KWS Conference
    • /
    • 1994.10a
    • /
    • pp.89-92
    • /
    • 1994
  • According to the industrial development welding technology is necessitated to develop in the direction of full automation, high efficiency, energy saving, and full safety. In this study, thus, a simple holder ampere controller for welding systems is developed and applied to arc welders and its capability is examined and tested. The results are as follows: 1. It has a simple structure, since the primary AC power for the welder can be directly control led using a triac. 2. It can control the electric power strength in several steps as well as on and off easily, since a small-sized variable resistance is installed in the small controller on the welding holder. 3. In real field applications a welding system with this controller increases the working efficiency greatly compare to the conventional arc welders without the system, because the controller can control the ampere onsite far from the main power supply. 4. It can reduce the probability of the electrical mishap due to electrical leakage, since the electricity is disconnected as soon as the switch is off or welding person's hand is taken off from the welder after the work or for rest. 5. It can control the welding depth in the beginning and do the crater treatment well in the ending of welding, since it always supplies the relevent amount of electrical current. Therefore, it can improve the mechanical properties of the welding zone.

  • PDF

Implement of Watt-Hour Meter Monitoring System by Internet Map Based GUI using Power Line Communication (전력선 통신을 이용한 인터넷 맵 연동 전자계량기 모니터링 시스템 구현)

  • Park, Keun-Soo;Lee, Young-Ho
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.8 no.10
    • /
    • pp.1435-1441
    • /
    • 2013
  • This paper deals a watt-hour meter monitor system applying a Power Line Communication (PLC) MODEM and a Data Concentrator Unit (DCU) which can apply to Internet map based Graphical User Interface (GUI). The PLC MODEM is profitable by saving the cost of installing dedicated wiring, and Internet map GUI also is able to contribute an easy access to monitoring system for non export users. This system makes it possible to monitor the amount of electricity of previous/ current month metering data via Internet mapping service. The implement system can easily apply a PC-management for the electric charges and maintenance with gathering the metering data.

Implementation of Low Power Drying System with Bluetooth Communication (블루투스 통신을 갖는 저전력 건조 시스템 구현)

  • Kim, Young-Bin;Ryu, Conan.K.R
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2021.05a
    • /
    • pp.626-629
    • /
    • 2021
  • Recent home appliances requires convenience and low-power consumption. A convenient devices should be simple to control while having several functions. Intelligent sensors and utilization technologies are required to reduce energy consumption. This paper provides a smart drying system with Bluetooth communication function and energy reduction function. Design a control system that uses the Bluetooth function so that the smartphone monitors the drying control and the internal humidity condition. By detecting the humidity inside the dryer and controlling the speed of the motor, it has an energy-saving function.

  • PDF

A study on adaptation measures to climate crisis for water supply system of Jeju Special Self-Governing Province (제주특별자치도 상수도 기후위기 적응대책 연구)

  • Jinkeun Kim
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.37 no.6
    • /
    • pp.447-456
    • /
    • 2023
  • Risk assessment on Jeju Special Self-Governing Province(JSSGP)'s water supply facilities and establishment of adaptation measures for climate crisis factors were implemented. JSSGP's vulnerability to the climate crisis was high in the order of drought, heat wave, heavy rain and strong wind. As a drought adaptation measure, policies of water saving and revenue water ratio improvement were considered. As for the heat wave adaptation measure, the introduction of an advanced water treatment process was suggested in response to the increase of algae cell number which resulting in taste and odor problem. As for heavy rain adaptation measures, the installation and operation of automatic coagulant injection devices for water purification plants that take turbid surface water were proposed. As a measure to adapt to strong winds, stabilization of power supply such as installation of dual power line was proposed in preparation for power outages. It is expected that water facilities will be able to supply high-quality tap water to customers even under extreme climate conditions without interruption through risk assessment for climate crisis factors and active implementation of adaptation measures.

Clocked Low Power Rail-to-Rail Sense Amplifier for Ternary Content Addressable Memory (TCAM) Application (Ternary Content Addressable Memory를 위한 저 전력 Rail-to-Rail 감지 증폭기)

  • Ahn, Sang-Wook;Jung, Chang-Min;Lim, Chul-Seung;Lee, Soon-Young;Baeg, Sang-Hyeon
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.49 no.2
    • /
    • pp.39-46
    • /
    • 2012
  • The newly designed sense amplifier in this paper has rail-to-rail input range achieving low power consumption. Reducing static power consumption generated due to DC path to ground is key element for low power consumption in this paper. The proposed sense amplifier performs power-saving operation using negative feedback circuit that controls the current flow with the newly added PMOS input terminal. As a simulation result, the proposed sense amplifier consumed about over 50 % efficiency of the average power consumed by the typical Rail-to-Rail sense amplifier.

Dynamic Power Management For Energy Efficient Wi-Fi Direct (에너지 효율적인 Wi-Fi Direct를 위한 동적 전력 관리 기법)

  • Seo, Youn;Ko, Young-Bae
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.38B no.8
    • /
    • pp.663-671
    • /
    • 2013
  • Recently, the Wi-Fi Direct standard based on WLAN is getting more attention as a new technology for enabling D2D(Devide-to-Device) communications on mobile devices. However, due to limited power resource of mobile devices and, an energy inefficiency problem can be an issue. In order to solve this problem, the Wi-Fi Direct defines two power management schemes: Opportunistic scheme and Notice of Absence(NoA) scheme. However, there is no concrete description of which power management scheme would be better for when. In this paper, via comprehensive simulation studies using ns-3, we show that each scheme presents obviously different performance and energy efficiency according to data traffic patterns. We then propose more energy efficient way of dynamically switching the two power management schemes.

Development of Power Quality Measurement System for Harmonics Diagnosis of Electrical Equipment (전기설비의 고조파 진단을 위한 전력품질 측정시스템의 개발)

  • 유재근;이상익;전정채
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.17 no.6
    • /
    • pp.130-137
    • /
    • 2003
  • Because of falling-off in power quality by harmonics, obstacles like lowering of capability, noise, vibration of power facilities and so on are occurred. Also generation of harmonics is inevitable and the point at harmonics is seriously gathering strength because energy saving installation using semiconductor circuit as countermeasures to enhance energy efficiency will be broadly spread and the use of energy conversion equipment like motor speed control contrivance, energy keeping installation and so on will increase, in the future. In order to eliminate harmonics obstacle, precision measurement and analysis on voltage, current, power factor, the each ingredient of harmonic order, the percentage of total harmonic distortion, and so forth are needed. In this paper, we developed low-cost measurement system to measure and analyze power quality connected with harmonics and verified it's performance by measuring and analyzing power quality in the three-phase and four-wire system.