A Study of the Real-time Sensing by the Optical Current Sensor for GIS

  • Park, Won-Zoo;Kim, Yeong-Min
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.23 no.7
    • /
    • pp.75-80
    • /
    • 2009
  • In this study, a Web server was constructed using LabVIEW's DataSocket, which makes possible acquisition, analysis, and saving in real time. The output value of the optical current sensor at the web server PC was measured and the output value was displayed using the Web browser of the client PC. DataSocket by LabVIEW makes the construction of a Web server easier than other languages and is compatible with other application programs. An optical current sensor was composed using a 1310 [nm] laser diode, and 9/125 [${\mu}m$] standard single mode optical fiber and was created to be a close type sensor. Data measurement using Web servers has the advantage of monitoring electric power systems at a great distance and can fuse IT technology and electric power systems. Also, this measurement uses inexpensive mounting and programming when compared to existing measurement equipment allowing the construction of a measurement system in any situation or surrounding.

A Study of Illumination System with Electronic Ballast (전자식 형광등 안전기를 이용한 조명시스템의 연구)

  • 진영호;김민태;성세진
    • Proceedings of the KIPE Conference
    • /
    • 1998.07a
    • /
    • pp.466-469
    • /
    • 1998
  • The electronic fluorescent lamp ballast can promote the lighting efficiency up to 10-20% by driving high frequency with frequency transformation technique, and can completely eliminate the flickering phenomenon occurring from 60Hz frequency. The electronic ballast provides very high energy saving effects for it has high power fact than traditional ballast, and it is convenient to use. can extend the life of fluorescent lamp for it starts at once by driving with high frequency. However electronic ballast needs high price, and it can reduce the stability and reliability. This paper provides illumination systems which drive dozens of fluorescent lamps at the same time, to overcome these shortcomings of electronic ballast and utilize the advantage of electronic ballast.

  • PDF

A Study of Illumination System with Electronic Ballast

  • Jin, Yonggao;Seong, Sejin
    • Proceedings of the KIPE Conference
    • /
    • 1998.10a
    • /
    • pp.998-1002
    • /
    • 1998
  • The electronic fluorescent lamp ballast can promote the lighting efficiency up to 10-20% by driving high frequency with frequency transformation technique, and can completely eliminate the flickering phenomenon occurring from 60Hz frequency. The electronic ballast provides very high energy saving effects for it has high power factor than traditional ballast, and it is convenient to use, can extend the life cycle of fluorescent lamp for it starts at once by driving with high frequency. However electronic ballast needs high price, and it has the bad stability and reliability. This paper provides illumination systems, which drive dozens of fluorescent lamps at the same time, to overcome these shortcomings of electronic ballast and utilize the advantage of electronic ballast.

  • PDF

Survey and Analysis of Power Energy Usage of University Buildings (대학건축물의 전력에너지 사용량 조사 및 분석)

  • Youn, Nam Sik;Kim, Jeong Tai
    • KIEAE Journal
    • /
    • v.13 no.2
    • /
    • pp.27-32
    • /
    • 2013
  • For the past seven years, the increase in the energy consumption of universities in Korea has been 3.7 times higher than the overall increase in the energy consumption across Korea (22.5%). This is an example that shows that universities have been a massive source of greenhouse gases. Such an increase has been attributed to the new and expanded construction of architectural structures on campus. Many people argue that the increasing number of buildings may cause waste of energy and loss of efficiency. Therefore, this study was conducted as a preliminary study to derive energy efficiency measures for new university buildings. The two aspects of energy-saving as required by the eco-friendly structure certification standards have been applied to analyze the use of new/renewable energy and the energy consumption of new university buildings that have applied light density and light engineering methods. Based on these results, the major sources of energy of existing buildings and new university buildings were compared to comparatively discuss how effectively they improve energy performance.

A Implementation of a Electrical Energy Saving Controller with Muiti-Function (다기능 전기에너지 절전 장치의 구현)

  • Kim, Dea-Ro;Kwon, Huk-Dea;Ko, Sung-Hun;Lee, Seong-Ryong
    • Proceedings of the KIPE Conference
    • /
    • 2010.07a
    • /
    • pp.542-543
    • /
    • 2010
  • 본 논문에서는 전기에너지 절약과 계통의 전력품질을 향상시킬 수 있는 다기능 전기에너지 절전 장치를 제안한다. 제안된 시스템은 UPQC(Unified Power Quality Conditioner)를 응용한 형태로 전압제어형 전압원 인버터와 전류제어형 전압원 인버터로 구성된다. 계통과 병렬로 연결된 전류제어형 전압원 인버터는 부하에서 발생하는 무효전력성분을 보상하고, 부하와 직렬로 연결되는 전압제어형 전압원 인버터는 부하전압의 크기를 조정하여 전력소비를 절감시킨다. 본 논문에서는 제안된 시스템의 유용성을 확인하기 위해 비선형 부하조건에서 시뮬레이션 및 실험을 수행하였다.

  • PDF

Optimization of Energy Consumption in Cellular Access Networks (셀룰러 망의 에너지 소모 최적화 기법)

  • Lee, Jung-Girl;Back, Ju-Hoon;Choi, Yong-Hoon
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.39B no.2
    • /
    • pp.53-60
    • /
    • 2014
  • The recent electric power shortage has led to the vigorous study for energy conservation in the many different fields. In this paper, cell zooming technology, which can reduce the energy loss at the base stations controlling the transmission power of the stations depending on the changing trffic density for reduce energy consumption that occurs when there is little or no trffic in the service area, is proposed and energy conservation is confirmed by comparing base stations' service scenario depending on traffic change.

A study on capacitive transformer (용량성배전변압기에 관한 연구)

  • Sung Won Rhee
    • 전기의세계
    • /
    • v.18 no.2
    • /
    • pp.7-14
    • /
    • 1969
  • From the first customer located right at the substation to the last customer at the end of the line, voltage must be held within close limits, so the voltage regulation is more important than the thermal limit. On a typical distribution system during the peak load period, the voltage drop may be serious enough to cause unsatisfactory operation of home appliances in the residential area, and present many problems to manufacturing industries, where the voltage must be maintained within close limits to insure smooth operation. Among all the factors contributing to voltage drop in the distribution system, the voltage drop in the distribution transformer may account for 30% of this figure. If we can eliminate this factor, the power companies can provide better quality electricity to more customers with the existing distribution facilities, thus saving on initial investment costs. Taking all these problems into consideration, the author undertook the design of a capacitive transformer which would give zero voltage drop at rated load and at 80% lagging power factor while incorporating overload features to withstand 400% overload for at least 100 seconds. The following are the results obtained through design, manufacture and test of an initial experimental transformer built with these specific purposes.

  • PDF

High frequency Linked Grid-Connected PV System for Residential Use (고주파링크 방식을 이용한 계통연계형 태양광발전시스템)

  • Jung, Y.S.;Yu, G.J.;Lee, S.H.
    • Proceedings of the KIEE Conference
    • /
    • 2001.04a
    • /
    • pp.467-469
    • /
    • 2001
  • An investigation into power conditioners that interface with photovoltaic array and utilities has been completed. The rating for this investigation is residential system(3-5kW) that interface with a 220V single phase utility connection. As the result of this investigation, a 3kW high frequency PWM IGBT inverter feeding a high frequency isolation transformer with a sinusoidal current wave was selected. The output of the transformer rectified with a diode bridge rectifier, four IGBT, used as 60Hz switched, reverse the polarity of the rectified current on every other half cycle of the utility voltage. Even though the high frequency link system used more power semiconductors, a net size, weight, and parts cost saving result compared to the other systems due to elimination of 60Hz transformer.

  • PDF

Harmonic Distortion Level of Special loads and Method of Harmonic Distortion Management (특수수용가의 고조파전압 왜형현황과 고조파 관리 방안)

  • Hwang, Chi-U;Seung, Ki-Cheul
    • Proceedings of the KIEE Conference
    • /
    • 1997.07c
    • /
    • pp.875-877
    • /
    • 1997
  • Due to the development of electric energy conversion technology and need for energy saving most of the electric machinery and equipments are using power semiconductor switching elements, On the contrary semiconductor switching device is more sensitive to the voltage instability and voltage distortion. In order to manage the voltage distortion following foundation should be settled down in advance. First, reasonable and objective technical guidelines should be established. Second, monitoring network for power quality should be operated. In this paper measurement results of the harmonic distortion of the special loads are given and method for harmonic pollution management is discussed.

  • PDF

Research on Development of a dynamic LED lighting system (동적 LED 조명 시스템의 개발에 대한 연구)

  • Choi, Jong-Dae;Kim, Hyo-In;Yun, Geun-Young
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2011.04a
    • /
    • pp.168-173
    • /
    • 2011
  • Recently, from a saving energy and environmental lighting sources point of view, using LED lighting have been increased rapidly. The colors of light was applied to the control of dimmers that is composed of red, green, blue, and white(RGBW) to improve the quality of visual environment. Moreover this study has been processed to develop adjustable dynamic LED lighting system on SPD and definitize the various spectral power distribution and color temperature of light through the control of the four dimmers. It is possible to combine up to $432^4$ kinds of light. Measurement of illuminance of range on working surface was as 7~l,831 lux. Application of visual environment for occupants can be expected according to control of lighting performance.

  • PDF